Two Cores Aluminum Conductor XLPE Insulated ABC Cable
Two Cores Aluminum Conductor XLPE Insulated ABC Cable image
Get Latest Price Request a quote
- Overview
- Product Description
- Company Profile
Basic Info.
Packaging & Delivery
Product Description
We produce the ABC Electric Cable used for overhead line(duplex, triplex, quadruplex) in IEC standard, ASTM, BS, NF C 33-209 standard.
LV ABC cable(Aerial Bundle cable) with AAAC conductor
Service Drop Cable(ABC CABLE) are mainly used for electric power transmission, Duplex, Triplex, Quadruplex.
Service Drop Cable(ABC CABLE) are mainly used for electric power transmission, rebuiding of urban and forest regions. They can improves safety and reliance of electrified wire netting.
2. Type of Service Drop Cable:
Service Drop Cable(ABC CABLE) covers mainly three types:
Duplex Service Drop
Triplex Service Drop
Quadruplex Service Drop
The cable can be produced whose construction is phase conductor with neutral bare conductor or phase conductor with insulated neutral conductor, etc. And we can still produce the cables according to the request of customers.
3. Detaild Introduction of Service Drop Cable
3.1 Duplex Service Drop
Applications
To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower at a conductor temperature of 75 maximum.
Construction
Concentic strand or cmpressed 1350-H19 conductor, polyethylene or cross linked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy nertral messenger.
3.2 Triplex Service Drop
Applications
To supply power from the ulility`s lines to the consumer`s weatherhead. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation.
Construction
Concentic strand or cmpressed 1350-H19 conductor, polyethylene or cross linked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy nertral messenger.
3.3 Quadruplex Service Drop
Applications
Used to supply 3 phase power, usually from a pole-mounted transformer to the use`s servic head where connection to the service entance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors.
Construction
Conductors are concentrically standed, compressed 1350-H19 aluminium. Insulated with either polyethylene or XLPE. Neutral messengers aer concentrically stranded 6210 AAAC, AAC or ACSR.
service drop | |
16 mm 2 * 2C | ( AL7/1.70+PE O. D. 7.10) + AL7/1.70 or + AL6/1.70+G1/1.70 |
16 mm 2 * 4C | 3*(AL7/1.70+PE O. D. 7.10) + AL7/1.70 or + AL6/1.70+G1/1.70 |
25 mm 2 * 2C | ( AL7/2.12+PE O. D. 8.90) + AL7/2.12 or + AL6/2.12+G1/2.12 |
25 mm 2 * 4C | 3*(AL7/2.12+PE O. D. 8.90) + AL7/2.12 or + AL6/2.12+G1/2.12 |
35 mm 2 * 2C | ( AL7/2.50+PE O. D. 10.0) + AL7/2.50 or + AL6/2.50+G1/2.50 |
35 mm 2 * 4C | 3*(AL7/2.50+PE O. D. 10.0) + AL7/2.50 or + AL6/2.50+G1/2.50 |
50 mm 2 * 2C | ( AL19/1.78+PE O. D. 11.7) + AL19/1.78 |
50 mm 2 * 4C | 3*(AL19/1.78+PE O. D. 11.7) + AL19/1.78 |
70 mm 2 * 2C | ( AL19/2.12+PE O. D. 13.5) + AL19/2.12 |
70 mm 2 * 4C | 3*(AL19/2.12+PE O. D. 13.5) + AL19/2.12 |
95 mm 2 * 2C | ( AL19/2.50+PE O. D. 15.8) + AL19/2.50 |
95 mm 2 * 4C | 3*(AL19/2.50+PE O. D. 15.8) + AL19/2.50 |
Workshop
Shipment
We are China Two Cores Aluminum Conductor XLPE Insulated ABC Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular ABC Cable Products
Service Entrance Cable Aerial Bundled ABC Cable
0.6/1kv 4 Core 95sqmm ABC Aerial Bundle Cable Overhead Cable
Overhead Service Drop ABC Cable
Appaloosa Quadruplex Aerial Bundled Cable Aluminum Conductor with XLPE Insulation
Overhead Aluminum Conductor 35mm2 XLPE Insulated ABC Cable / Aerial Bundle Ca
AAAC Conductor All Aluminium Alloy Conductor ASTM Standard 1/0
Popular Cable Products
Type 61 Mining Cable 1.1 3.3 6.6kv 11kv 3*150+3*1.2mm+Control Core Cu/ Epr/Pcp with Reinforced
0.6/1kv Quadruplex Service Drop ABC Cable for Power Transmission Line
16 mm 4 Core AAC/XLPE ABC Cable
Underground Armoured Electrical Power Cable for 0.6/1kv
Overhead Bare Aluminum Conductor Electrical Cable Steel Reinforced ACSR Conductor with ASTM Standard
PVC HDPE XLPE Insulation 95mm ABC AAC AAAC ACSR Power Cable
Popular jpcable99 Products
Hot Seller Low Voltage XLPE Insulated Power Cable
6/6 6/10kv Single Copper Core/XLPE Insulated /Unarmored/ Power Cable
12/20kv Medium Voltage XLPE/Swa/PVC Power Cable 1*50 1*70
Good Quality ACSR/Aw Bare Conductor
450/750V Copper Conductor PVC Insulated and Sheathed Control Cable
Aluminium Clad Stainless Steel Tube Opgw Fiber Optic Cable