U-Bolts 3/4

China 
                        U-Bolts 3/4 
                      manufacture and supplier

U-Bolts 3/4 image

Get Latest Price Request a quote

Quick Details

U-Bolts 3/4

Oei Power

IEC IEEE

Manual

Ist

Turn the Horizontal

Three

Single Ground

Three Pole

Horizontal Rotary Type

Grounding

Manual

Outdoor High-voltage

Three-column Disconnector

High-voltage

Kv

Kv

Kv

OEI Power

Wooden Case

IEC IEEE

China Nanyang

8535309000

Product Details


Diagram is not drawing to scale.
 

Material:          Coating:           Dimensions:     Thickness Dia:

Steel
Dip Galvanized, ASTM A- 153
Shown in the picture above (fig. 9)
3/4 in.

Center Break Isolator and double Break Isolator

 

These disconnectors are , no load switching devices
which physically isolate the lines. They are designed for
horizontal outdoor application and can also be designed
for vertical installation. For earthing and closing of
switchyard portions of the installation, the earthing
switches are provided on disconnector. If required.

The following documents were referred to during the preparation of this specification. In case of conflict, the provisions of this specification shall take precedence.
IEC 129:1975: Alternating Current Disconnectors (Isolators) and Earthing Switches
IEC 60694:2002: Common Specifications for High Voltage Switchgear and Controlgear
BS 729: Hot dip galvanized coating on iron and steel articles
IEC62271-102
Isolator (Disconnector) – a mechanical switching device which provides, in the open position, an isolating distance in accordance with Electrical Safety requirements.

SERVICE CONDITIONS
The isolator shall be suitable for continuous operation outdoors in tropical areas at altitudes of up to 2200m above sea level, humidities of up to 90%, average ambient temperature of +30ºC with a minimum of -1ºC and a maximum of +40ºC and heavy saline conditions along the coast.

4.2. DESIGN AND CONSTRUCTION
4.2.1 The Isolator, Solid Link shall be designed and constructed in accordance with IEC 129 and IEC 60694.
4.2.2 The isolating link shall be of the vertical opening, designed for single phase manual operation. It shall be easily removed and replaced by using a portable operating rod.
4.2.3 The isolating link shall incorporate double porcelain insulators to suit voltage requirements and mounted on hot dipped galvanised steel under base suitable for vertical mounting.
4.2.4 The isolating link shall be arranged so that each unit is mounted independently on an angle bracket. It shall be supplied complete with the angle bracket and accessories suitable for mounting on ‘U’ type steel channel. The drawings to be submitted shall indicate all the applicable mounting positions.
4.2.5 The isolator shall be designed such that in fully open position, it shall provide adequate electrical isolation between the contacts on each phase. It shall conform to the requirement as single point isolation for safety.
4.2.6 All steel parts shall be hot dip galvanized to BS 729. The minimum coating of galvanizing required is 80 microns.
4.2.7 The solid link shall be removable from the mounting by use of operating rod.
4.2.8 All current carrying parts of the isolator shall be made of high conductivity material.
4.2.9 The isolator shall be fitted with clamp connectors for Aluminium (ACSR) conductor of Aluminium (ACSR)conductor of up to 18.2mm diameter.

The rating of the complete isolator shall be as follows: –
Rated voltage
36 kV
Rated frequency
50 Hz
Rated lightning impulse withstand voltage
200 kV
Rated power frequency withstand voltage, dry
95 kV
Rated normal current
400 Amps
Rated short time withstand current for 3 sec, min.
18.0 kA
Minimum creepage distance of insulators
900 mm
 

 SOLID LINKS 11KV
 
 
 
 
 

N/O DETAIL   DATA
1 Description   Solid link assembly complete with link
rated at 200A and mounting bracket to PIESA 002. (See Figure 1  to Figure 12 below)
2 System conditions of service
 
 
 
a) nominal Voltage (Un) r.m.s
 
 
 
 
kV
 
 
 
 
11
b) maximum system voltage (Um) r.m.s KV 12
c) earthing   Effective & non effective
d) Frequency Hz 50
3 Site conditions of service
a) altitude
 
m
 
1400
b) Operating Ambient temperature °C 1 to 40
c) Humidity % 85
4 Rating    
a) Nominal voltage kV 11
b) Rated current Solid link  
A
 
200
 
Cut out base
 
A
 
200
5 Electrical components    
a) Insulator material specification   Porcelain
Dielectric strength    
Lightning  impulse withstand (1.2/50) kV 95
Power frequency wet withstand voltage
r.m.s
kV 28
6 Specific creepage distance mm/kV 25

 

 
 

7 General information to be provided
with bid:
Drawings and brochures showing outline and general arrangement
 
 
 
 
Yes/No
 
 
 
 
Yes
  b) Detailed drawings of all items
showing critical tolerances to be provided with bid
Yes/No Yes
8 Previous Type test report/certificate on
complete solid link assembly to be provided with bid
 
Yes/No
 
Yes
10 Routine tests (acceptance tests on
sample
Product) to be provided on delivery
Yes/No Yes
11 Applicable standard   PIESA 002
12 Other applicable standards   NRS 035
SABS IEC 602822
SABS IEC 60186
BS 137 part 2

 

 
 

TRILINKS
 
 
 
Lot 3(a) 11kV with interrupters
 
 
 

N/O DETAIL   DATA
1 TYPE   11kV pre-assembled gang
operated overhead line load break switch complete with expulsion interrupters
2 Mounting configuration   Horizontal
3 Mode of operation   Manually operated pole
mounted linking rod and handle with locking facilities
  a) nominal Voltage (Un) r.m.s kV 11
b) maximum voltage (Um) r.m.s KV 12
c) earthing   Effective & non effective
d) Frequency Hz 50
e) rated current Amp 400
f) Fault closing capacity kA 12.5
4 Site conditions of service
a) altitude
 
metres
 
1400
b) Operating Ambient temperature  
°C
 
1 to +40
c) Relative humidity % 85
5 Electrical components    
a) Insulator material specification   High Temperature Vulcanised
Silicon rubber
b) Cross arm and operating controls materials   Hot dip galvanized steel to
SAN760
Dielectric strength    
Lightning  impulse withstand (1.2/50) kV 95

 

 
 

  Power frequency wet withstand voltage r.m.s KV 28
  Short time current rating 1sec kA 12.5
6 creepage distance mm/kV 25
7 General information to be provided with bid:
Drawings and brochures showing
Outline and general arrangement
 
 
 
Yes/No
 
 
 
Yes
8 Previous Type test report/certificate on complete
assembly to be provided with bid
Yes/No Yes.
9 Routine tests (acceptance tests on sample
 
Product) to be provided on delivery.
Yes/No Yes
10 Applicable standards   IEC62271

 

 
 
FURTHER REQUIREMENTS:
 
Water shall not be able to accumulate on any part of the equipment nor shall any feature introduce moisture into any component.
The design shall incorporate all reasonable precautions and provisions for the safety of personnel concerned with the operation and maintenance of the same.
The current path shall be such that load current shall only flow through high conductive materials such as copper and its alloys. Load current shall not be permitted to flow through ferrous components, springs, or springloaded mechanisms.
All load current paths shall be so designed that the relevant parts of the switch are capable of carrying the specified rated current without exceeding the permitted temperature rise.
 
 
 
SUPPLIMENTARY NOTES
 
Suppliers should give sufficient information including drawings (which must be brief, clear and to the point) on how their switch designs addresses these requirements. Further, Suppliers may offer better alternatives that are of cost benefits to customer, It is therefore imperative that schedule "B" is completed by the tenderer. Any deviations/modifications/alternatives specification must be listed in schedule "C.
 
 

 

 
 
 
 
33kV with interrupters
 
 
 

N/O DETAIL   DATA
1 TYPE   33kV pre-assembled gang
operated overhead line load break switch complete with expulsion interrupters
2 Mounting configuration   Horizontal
3 Mode of operation   Manually operated pole
mounted linking rod and handle with locking facilities
  a) nominal Voltage (Un) r.m.s kV 33
b) maximum voltage (Um) r.m.s KV 36
c) earthing   Effective & non effective
d) Frequency Hz 50
e) rated current Amp 200
f) Fault closing capacity kA 12.5
4 Site conditions of service
a) altitude
 
metres
 
1400
b) Operating Ambient temperature  
°C
 
1 to +40
c) Relative humidity % 85
5 Electrical components    
a) Insulator material specification   High Temperature Vulcanised
Silicon rubber
b) Cross arm and operating controls materials   Hot dip galvanized steel to
SAN760
Dielectric strength    
Lightning  impulse withstand (1.2/50) kV 170
Power frequency wet withstand voltage r.m.s KV 70
  Short time current rating 1sec kA 12.5
6 creepage distance mm/kV 25
7 General information to be provided with bid:    

 

 
 

  Drawings and brochures showing
Outline and general arrangement
 
Yes/No
 
Yes
8 Previous Type test report/certificate on complete
assembly to be provided with bid
Yes/No Yes
9 Routine tests (acceptance tests on sample
 
Product) to be provided on delivery
Yes/No Yes
10 Applicable standards   IEC62271

 

 
 
FURTHER REQUIREMENTS:
 
Water shall not be able to accumulate on any part of the equipment nor shall any feature introduce moisture into any component.
The design shall incorporate all reasonable precautions and provisions for the safety of personnel concerned with the operation and maintenance of the same.
The current path shall be such that load current shall only flow through high conductive materials such as copper and its alloys. Load current shall not be permitted to flow through ferrous components, springs, or springloaded mechanisms.
All load current paths shall be so designed that the relevant parts of the switch are capable of carrying the specified rated current without exceeding the permitted temperature rise.
 
 
 
SUPPLIMENTARY NOTES
 
Suppliers should give sufficient information including drawings (which must be brief, clear and to the point) on how their switch designs addresses these requirements. Further, Suppliers may offer better alternatives that are of cost benefits to custoemr.
 
 
 

 

 
 
 
 
11kV without interrupters
 
 
 
 

N/O DETAIL   DATA
1 TYPE   11kV pre-assembled gang
operated overhead line switch without expulsion interrupters (nonload break switch)
2 Mounting configuration   Horizontal
3 Mode of operation   Manually operated pole
mounted linking rod and handle with locking facilities
  a) nominal Voltage (Un) r.m.s kV 11
b) maximum voltage (Um) r.m.s KV 12
c) earthing   Effective & non effective
d) Frequency Hz 50
e) rated current Amp 400
4 Site conditions of service
a) altitude
 
metres
 
1400
b) Operating Ambient temperature  
°C
 
1 to +40
c) Relative humidity % 85
5 Electrical components    
a) Insulator material specification   High Temperature Vulcanised
Silicon rubber
b) Cross arm and operating controls materials   Hot dip galvanized steel to
SAN760
Dielectric strength    
Lightning  impulse withstand (1.2/50) kV 95
Power frequency wet withstand voltage r.m.s KV 28
  Short time current rating 1sec kA 12.5
6 creepage distance mm/kV 25
7 General information to be provided with bid:    

 

 
 

  Drawing and brochures showing
Outline and general arrangement
 
Yes/No
 
Yes
8 Previous Type test report/certificate on complete
assembly to be provided with bid
Yes/No Yes
9 Routine tests (acceptance tests on sample
 
Product) to be provided on delivery
Yes/No Yes
10 Applicable standards   IEC62271

 

 
 
FURTHER REQUIREMENTS:
 
Water shall not be able to accumulate on any part of the equipment nor shall any feature introduce moisture into any component.
The design shall incorporate all reasonable precautions and provisions for the safety of personnel concerned with the operation and maintenance of the same.
The current path shall be such that load current shall only flow through high conductive materials such as copper and its alloys. Load current shall not be permitted to flow through ferrous components, springs, or springloaded mechanisms.
All load current paths shall be so designed that the relevant parts of the switch are capable of carrying the specified rated current without exceeding the permitted temperature rise.
 
 
 
SUPPLIMENTARY NOTES
 
Suppliers should give sufficient information including drawings (which must be brief, clear and to the point) on how their switch designs addresses these requirements. Further, Suppliers may offer better alternatives that are of cost benefits to
 

 

 
 
 
 
 
33kV without interrupters
 
 

N/O DETAIL   DATA
1 TYPE   33kV pre-assembled gang
operated overhead line switch without expulsion interrupters (nonload break switch)
2 Mounting configuration   Horizontal
3 Mode of operation   Manually operated pole
mounted linking rod and handle with locking facilities
  a) nominal Voltage (Un) r.m.s kV 33
b) maximum voltage (Um) r.m.s KV 36
c) earthing   Effective & non effective
d) Frequency Hz 50
e) rated current Amp 200
4 Site conditions of service
a) altitude
 
metres
 
1400
b) Operating Ambient temperature  
°C
 
1 to +40
c) Relative humidity % 85
5 Electrical components    
a) Insulator material specification   High Temperature Vulcanised
Silicon rubber
b) Cross arm and operating controls materials   Hot dip galvanized steel to
SAN760
Dielectric strength    
Lightning  impulse withstand (1.2/50) kV 170
Power frequency wet withstand voltage r.m.s KV 70
  Short time current rating 1sec kA 12.5
6 creepage distance mm/kV 25
7 General information to be provided with bid:    

 

 
 

  Drawing and brochures showing
Outline and general arrangement
 
Yes/No
 
Yes
8 Previous Type test report/certificate on complete
assembly to be provided with bid
Yes/No Yes
9 Routine tests (acceptance tests on sample
 
Product) to be provided on delivery
Yes/No Yes
10 Applicable standards   IEC62271

 
 
FURTHER REQUIREMENTS:
 
Water shall not be able to accumulate on any part of the equipment nor shall any feature introduce moisture into any component.
The design shall incorporate all reasonable precautions and provisions for the safety of personnel concerned with the operation and maintenance of the same.
The current path shall be such that load current shall only flow through high conductive materials such as copper and its alloys. Load current shall not be permitted to flow through ferrous components, springs, or springloaded mechanisms.
All load current paths shall be so designed that the relevant parts of the switch are capable of carrying the specified rated current without exceeding the permitted temperature rise.
 
 
 
SUPPLIMENTARY NOTES
 
Suppliers should give sufficient information including drawings (which must be brief, clear and to the point) on how their switch designs addresses these requirements. Further, Suppliers may offer better alternatives that are of cost benefits to.
 

View More  

Not exactly what you want?

Post Sourcing Request

Hot Searches

Switch Box
Time Switch
Level Switch
Industrial Switch
Manual Switch
Range Switch
View More 

We are China U-Bolts 3/4 manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular Disconnect Switch Products

Outdoor High Voltage Porcelain Isolated Switch Series

Hkgwf-36 High Voltage Disconnect Switch Manufacturer Quality Disconnector

Outdoor Three Phase High Voltage Disconnect Switch 33kv

Outdoor AC System High-Voltage 252kv 200A to 4000A Disconnector Switch

_DSC3526-1

11kv Silicon Isolator Insulator, Isolator Switch, Gang Insulator, Isolation Switch, Disconnect Switch

Popular Disconnector Products

High -Voltage Isolate Switch 15kv 600A

Gw9 -12/630 Series Hv Outdoor High Voltage Disconnect /Switch Isolator Disconnect Switch / Isolator Switch Isolator

110kv 1250A Double Earthed Disconnector / Isolator Switch

Load Break Switch 24kv 400A

China Factory Gw4 Series Outdoor AC Isolating Switch

Load Break Switch 36kv 600A

Popular Isolator Switch Products

Load Break Switch 36kv 600A

33kv Isolator Current 2000A with Earth Switch Isolator

Iacm Switch Disconnector 50A-24kv with Socket and Command

Load Break Switch 12kv

High -Voltage Isolate Switch 12kv 1000A

Surge Arrestor 11kv

Popular jgtrade1 Products

Yoke Plates Type L Lt Lz

Surge Arrester Yh10W-21

60kv Capacators

Fuselink, Cartridge 415V - 30 AMPS -Me30A

Stay Rod

Fuse Cutout, Drop out Fuses 24kv 300A

Tags: , , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION