UL 1 Core PVC Insulated Electric Wire Electrical Wire Cable 600V Wire
UL 1 Core PVC Insulated Electric Wire Electrical Wire Cable 600V Wire image
Get Latest Price Request a quote
Quick Details
Product Details
UL 1 Core PVC Insulated Electric Wire Electrical Wire Cable 600V Wire
Description:
– Model No. : AC10WE32
– Size : #18AWG 34/0.18mm 105°c / 1 core
– Tinned or bare stranded 9-28AWG copper or tinned copper
– PVC insulated
– Temperature: 105 °c ; Voltage: 600Vac
– Use the standard thickness, easy stripping and cutting easy
– with anti-acid. oil resistance. moisture. mildew and other characteristics
– Passes UL VW-1 & CSA FT1 vertical flame test
– OS-1 is available
1 |
Model |
AC10WE30 |
||
2 |
Standard |
UL/CSA : 105°c, 600 Vac, 750 Vdc, 30# ~ 2,000 kcMil |
||
3 |
Construction & Dimension |
|||
Item |
Specification |
|||
Conductor |
Size |
34/0.18±0.01mm |
||
Material |
Annealed Bare Copper |
|||
Insulation |
Material |
PVC |
||
Min. Average Thickness |
0.762mm |
|||
Min. Thickness at any point |
1.0mm |
|||
Diameter |
2.8±0.10mm |
|||
Identification |
Blue, Brown, Yellow, Green, White, Black, Red |
|||
Core Assembly |
Core Twist |
Single Core |
||
Filler |
NA |
|||
Assembly Pair |
NA |
|||
Taping |
Mylar Foil |
NA |
||
Shielded |
A1 – Mylar Foil |
NA |
||
Drain |
Material |
NA |
||
Construction |
NA |
|||
Jacket |
Material |
PVC |
||
Min Average Thickness |
0.90mm |
|||
Min. Thickness at any point |
0.67mm |
|||
Overall Diameter (Approx) |
8.5±0.20 |
|||
Color |
Any Color |
|||
4 |
Electrical & Physical Properties |
|||
Item |
Specification |
|||
Rating Voltage |
600V |
|||
Conductor Resistance |
6.64Ω/kft 20°c Max |
|||
In case of dispute, Conductor resistance shall be the referee method |
||||
Insulation Resistance |
0.010MΩ/Km 70°c Min |
|||
Dielectric Strength |
AC 2.0KV/5 min No Break |
|||
Insulation |
Unaged |
Tensile Strength |
10N/mm² |
|
Elongation |
150% Min |
|||
Aged |
Tensile Strength |
Min 10N Unaged±20%(85±2°cx240hrs) |
||
Elongation |
Min 150% Unaged±20%(85±2°cx240hrs) |
|||
Loss of mass Test |
2.0mg/cm² (max) |
|||
Jacket |
Unaged |
Tensile Strength |
10N/mm² |
|
Elongation |
150% Min |
|||
Aged |
Tensile Strength |
Min 10N Unaged±20%(85±2°cx240hrs) |
||
Elongation |
Min 150% Unaged±20%(85±2°cx240hrs) |
|||
Loss of mass Test |
2.0mg/cm² (max) |
|||
Deformation Test |
150mm, 70±2°c x 1hr≤50% |
|||
Cold Bend Test |
-15±2°c x 4hr No Crack |
|||
Heat Shock Test |
150±2°c x 1hr No Crack |
Electric Properties |
|
Item |
Specification |
Specified voltage and temperature & standard |
UL/CSA : 105°c, 600Vac, 750Vdc, ROHS / RECH |
Spark Test |
The insulation must be withstand 5KV high-tension current |
Insulation Potengial Strength |
2000V/Min(for water’s environment |
Minimum Insulation Resistance |
20°c, DC500V 15MΩ-KM Above |
Physical Properties |
|||
Based on standard of flammability material testing |
According for UL Subj.758 spec/According for CSA spec |
|
|
Before of aging test |
Insulation tensile strength test kgf/mm2 |
1500 psi above |
|
Insulation elongation test rate % |
100% above |
|
|
After of aging test |
Insulation tensile remnant rate % |
This amount must be above 70% after heat ageing (136°c,168hrs) |
|
Insulation elogates remnant rate % |
This amount must be above 65% after heat aging (136°c,168hrs) |
|
|
Heating Distortion Test |
The insulation face must be no cracked, high temperature at 120°c for 1 hour |
|
|
Thermo Shock Test |
The insulation face must be no cracked, high temperature at 120°c for 1 hour and bent, to withstand 1,000V for 1 Min |
|
|
Cold Bending Test |
The insulation face must be no cracked, cooled at -40°c for 3 hour and bent to withstand 1000V for 1 Min |
|
|
Oil Resistance |
Immersed in oil at 80°c for 4 hrs and bent to withstand 1000V for 1 Min |
|
Hot sale products
Exhibition:
Certificates
Packaging & Shipping
All cable For exporting are well packed and protected by wooden drum or Wood and Steel Drum.The packing material is depended on the weight and size of cable.The good information, manufacture information, and the client’s information is firmly printed on each size of drum.
After the well packed cable drums sent to Sea Port, they are loaded into 20 FT container or 40 FT container. All cable drum are firmly fixed by safety belt to make sure, no movement during the sea freight.
The size of the container is chosed according to weight of total loaded goods or as per the client’s requirement.
UL 1 Core PVC Insulated Electric Wire Electrical Wire Cable 600V Wire
Contact Us By Follow Information
Sales Manager: Leslie Shaw
Shandong New Luxing Cable Co.,Ltd
Phone No:+86 15053169342
Tel:+86-531-88698938 Fax:+86-531-88662923
Web:luxingcable.en. / luxingcable.en.
Factory Add:West Side, Southern Huaxing Road, Linyi Town, Dezhou city,Shandong Province,China
Office Add:Room D901, Binhe Business Center, Tiaoqian district, Jinan city, Shandong Province,China
We are China UL 1 Core PVC Insulated Electric Wire Electrical Wire Cable 600V Wire manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular 1 Core Electrical Cable Products
Popular 1 Core Electrical Wire Products
Popular Electrical Wire Products
2.5 mm Electrical Wire Copper Classic Yy Shipboard Outboard Control Cable
Rubber Sheathed Electrical Copper CCA Conductor Electric Welding Cable
Multi Cores Flex Cable Electric Control Cable Instrument Cable Signal Cable
Copper Rvs Twisted Flexible PVC Electric Wire
Ce Approved Copper Conductor PVC Insulated Electric Kabel for Equipment and Household
Popular luxingcable Products
TUV Approved Electrical DC Solar PV Cable 6mm for Photovoltaic System
PVC Insulation Yjv 5 Core Power Cable 4mm
Awm 2464 Cable 5core Copper Conductor Electric Control Power Cable Wire Factory Price
Cable Factory BVVB 2 Core 6mm2 Electrical Power Cable
Electrical Wire Factory Electrical Wire 4 Core 95mm Power Cable
Xv (U1000R2V) (XLPE/PVC) 0, 6/1 Kv From Luxing Cable Factory
Tags: 1 Core Electrical Cable, 1 Core Electrical Wire, Electrical Wire, luxingcable