XLPE 3 Phase Armoured Aluminum Solidal Power Cable
XLPE 3 Phase Armoured Aluminum Solidal Power Cable image
Get Latest Price Request a quote
Quick Details
Product Details
Standard:
IEC60502,and BS6346, VDE, AS/NZS, UL,etc or as customer’s request.
The Rated Voltage(kv):
1st class 0.6/1 1.8/3 3.6/6 6/10 8.7/15 12/20 18/30 21/35
2nd class 1/1 3/3 6/6 8.7/10 12/15 18/20 – 26/35
Application:
Power cable are most suitable for direct burial or for installation on trays or ducts, Where there is
a risk of mechanical damage, armoured cables should be used.
| TYPE | NAME | Main Application | |
| CU core | AL core | ||
| YJV/YJY | YJLV/YJLY | XLPE insulated,PVC/PE sheathed power cable | For laying indoor ,tunnel,canal and underground. Unable to bear external mechanical forces, but bear the traction force during laid |
| YJV22/YJV23 | YJLV22/YJLV23 | XLPE insulated,steel tape armored, PVC/PE sheathed power cable |
For laying indoor ,tunnel,canal and underground. Able to bear external mechanical forces, but unable to bear large pulling force |
| YJV32/YJV33 | YJLV32/YJLV33 | XLPE insulated,thin steel wire armored, PVC/PE sheathed power cable |
For laying in shaft,water underground will large difference of level. Able to bear external mechanical forces and moderate pulling force |
| YJV42/YJV43 | YJLV42/YJLV43 | XLPE insulated,thick steel wire armored, PVC/PE sheathed power cable |
For laying in water and seabed. Able to bear positive pressure and pulling force |
| Nominal Cross Section |
Diameter of Conductor (Approx.) |
Nominal Insulation thickness |
Nominal Inner Covering thickness |
Nominal Alum Wire dia. |
Nominal Sheath thickness |
Overall Diameter (Approx.) |
| mm² | mm | mm | mm | mm | mm | mm |
| 1×4 | 2.3 | 0.7 | 1 | 0.8 | 1.8 | 10.9 |
| 1×6 | 2.8 | 0.7 | 1 | 0.8 | 1.8 | 11.4 |
| 1×10 | 3.6 | 0.7 | 1 | 0.8 | 1.8 | 12.2 |
| 1×16 | 4.5 | 0.7 | 1 | 0.8 | 1.8 | 13.1 |
| 1×25 | 5.6 | 0.9 | 1 | 0.8 | 1.8 | 14.6 |
| 1×35 | 6.7 | 0.9 | 1 | 1.25 | 1.8 | 16.6 |
| 1×50 | 8 | 1 | 1 | 1.25 | 1.8 | 18.1 |
| 1×70 | 9.4 | 1.1 | 1 | 1.25 | 1.8 | 19.7 |
| 1×95 | 11 | 1.1 | 1 | 1.6 | 1.8 | 22 |
| 1×120 | 12.4 | 1.2 | 1 | 1.6 | 1.8 | 23.6 |
| 1×150 | 13.8 | 1.4 | 1 | 1.6 | 1.8 | 25.4 |
| 1×185 | 15.3 | 1.6 | 1 | 1.6 | 1.8 | 27.4 |
| 1×240 | 17.5 | 1.7 | 1 | 1.6 | 1.9 | 29.9 |
| 1×300 | 19.5 | 1.8 | 1 | 2 | 2 | 33.1 |
| 1×400 | 22.6 | 2 | 1.2 | 2 | 2.2 | 37.3 |
| 1×500 | 25.2 | 2.2 | 1.2 | 2 | 2.3 | 40.5 |
| Nominal Cross Section |
Diameter of Conductor (Approx.) |
Nominal Insulation thickness |
Nominal Inner Covering thickness |
Nominal Steel Wire dia. |
Nominal Sheath thickness |
Overall Diameter (Approx.) |
| mm² | mm | mm | mm | mm | mm | mm |
| 2×1.5 | 1.4 | 0.7 | 1 | 0.8 | 1.8 | 12.8 |
| 2×2.5 | 1.8 | 0.7 | 1 | 0.8 | 1.8 | 13.6 |
| 2×4 | 2.3 | 0.7 | 1 | 0.8 | 1.8 | 14.6 |
| 2×6 | 2.8 | 0.7 | 1 | 1.25 | 1.8 | 16.5 |
| 2×10 | 3.6 | 0.7 | 1 | 1.25 | 1.8 | 18.1 |
| 2×16 | 4.5 | 0.7 | 1 | 1.25 | 1.8 | 19.9 |
| 2×25 | 5.6 | 0.9 | 1 | 1.6 | 1.8 | 23.6 |
| 2×35 | 6.7 | 0.9 | 1 | 1.6 | 1.8 | 25.8 |
| 2×50 | 8 | 1 | 1 | 1.6 | 1.9 | 29 |
| 2×70 | 9.4 | 1.1 | 1 | 2 | 2 .3 | 3.2 |
| 2×95 | 11 | 1.1 | 1.2 | 2.1 | 3 | 7.1 |
| 2×120 | 12.4 | 1.2 | 1.2 | 2 | 2.3 | 40.5 |
| 2×150 | 13.8 | 1.4 | 1.2 | 2.5 | 2.4 | 45.4 |
| 2×185 | 15.3 | 1.6 | 1.4 | 2.5 | 20.6 | 49.9 |
| 2×240 | 17.5 | 1.7 | 1.4 | 2.5 | 20.7 | 55.1 |
| 2×300 | 19.5 | 1.8 | 1.6 | 2.5 | 20.9 | 60.2 |
| 2×400 | 22.6 | 2 | 1.6 | 2.5 | 30.1 | 67.7 |
| Nominal Cross Section |
Diameter of Conductor (Approx.) |
Nominal Insulation thickness |
Nominal Inner Covering thickness |
Nominal Steel Wire dia. |
Nominal Sheath thickness |
Overall Diameter (Approx.) |
| mm² | mm | mm | mm | mm | mm | mm |
| 3×1.5 | 1.4 | 0.7 | 1 | 0.8 | 1.8 | 13.2 |
| 3×2.5 | 1.8 | 0.7 | 1 | 0.8 | 1.8 | 14.1 |
| 3×4 | 2.3 | 0.7 | 1 | 0.8 | 1.8 | 15.2 |
| 3×6 | 2.8 | 0.7 | 1 | 1.25 | 1.8 | 17.1 |
| 3×10 | 3.6 | 0.7 | 1 | 1.25 | 1.8 | 18.9 |
| 3×16 | 4.5 | 0.7 | 1 | 1.25 | 1.8 | 20.8 |
| 3×25 | 5.6 | 0.9 | 1 | 1.6 | 1.8 | 24.7 |
| 3×35 | 6.7 | 0.9 | 1 | 1.6 | 1.8 | 27.2 |
| 3×50 | 8 | 1 | 1 | 1.6 | 1.9 | 30.6 |
| 3×70 | 9.4 | 1.1 | 1 | 2 | 2.1 | 35.2 |
| 3×95 | 11 | 1.1 | 1.2 | 2 | 2.2 | 39.3 |
| 3×120 | 12.4 | 1.2 | 1.2 | 2 | 2.3 | 43 |
| 3×150 | 13.8 | 1.4 | 1.4 | 2.5 | 2.5 | 48.6 |
| 3×185 | 15.3 | 1.6 | 1.4 | 2.5 | 2.7 | 53 |
| 3×240 | 17.5 | 1.7 | 1.4 | 2.5 | 2.8 | 58.5 |
| 3×300 | 19.5 | 1.8 | 1.6 | 2.5 | 3 | 64 |
| 3×400 | 22.6 | 2 | 1.6 | 3.15 | 3.3 | 73.5 |
| Nominal Cross Section |
Diameter of Conductor (Approx.) |
Nominal Insulation thickness |
Nominal Inner Covering thickness |
Nominal Steel Wire dia. |
Nominal Sheath thickness |
Overall Diameter (Approx.) |
||
| mm² | mm | mm | mm | mm | mm | mm | mm | mm |
| 3x 16/10 | 4.5 | 3.6 | 0.7 | 0.7 | 1 | 1.6 | 1.8 | 22.7 |
| 3x 25/16 | 5.6 | 4.5 | 0.9 | 0.7 | 1 | 1.6 | 1.8 | 26.5 |
| 3x 35/16 | 6.7 | 4.5 | 0.9 | 0.7 | 1 | 1.6 | 1.9 | 29 |
| 3x 50/25 | 8 | 5.6 | 1 | 0.9 | 1 | 1.6 | 2.1 | 33 |
| 3x 70/35 | 9.4 | 6.7 | 1.1 | 0.9 | 1.2 | 2 | 2.2 | 38 |
| 3x 95/50 | 11 | 8 | 1.1 | 1 | 1.2 | 2 | 2.3 | 42.4 |
| 3×120/70 | 12.4 | 9.4 | 1.2 | 1.1 | 1.2 | 2 | 2.5 | 48 |
| 3×150/70 | 13.8 | 9.4 | 1.4 | 1.1 | 1.4 | 2.5 | 2.7 | 52 |
| 3×185/95 | 15.3 | 11 | 1.6 | 1.1 | 1.4 | 2.5 | 2.8 | 57.2 |
| 3×240/120 | 17.5 | 12.4 | 1.7 | 1.2 | 1.6 | 2.5 | 3.1 | 64 |
| 3×300/150 | 19.5 | 13.8 | 1.8 | 1.4 | 1.6 | 2.5 | 3.2 | 69.8 |
| Nominal Cross Section |
Diameter of Conductor (Approx.) |
Nominal Insulation thickness |
Nominal Inner Covering thickness |
Nominal Steel Wire dia. |
Nominal Sheath thickness |
Overall Diameter (Approx.) |
| mm² | mm | mm | mm | mm | mm | mm |
| 4×1.5 | 1.4 | 0.7 | 1 | 0.8 | 1.8 | 14 |
| 4×2.5 | 1.8 | 0.7 | 1 | 0.8 | 1.8 | 14.9 |
| 4×4 | 2.3 | 0.7 | 1 | 1.25 | 1.8 | 17 |
| 4×6 | 2.8 | 0.7 | 1 | 1.25 | 1.8 | 18.2 |
| 4×10 | 3.6 | 0.7 | 1 | 1.25 | 1.8 | 20.2 |
| 4×16 | 4.5 | 0.7 | 1 | 1.6 | 1.8 | 23 |
| 4×25 | 5.6 | 0.9 | 1 | 1.6 | 1.8 | 26.7 |
| 4×35 | 6.7 | 0.9 | 1 | 1.6 | 1.9 | 29.5 |
| 4×50 | 8 | 1 | 1 | 2 | 2.1 | 34.2 |
| 4×70 | 9.4 | 1.1 | 1.2 | 2 | 2.2 | 38.8 |
| 4×95 | 11 | 1.1 | 1.2 | 2 | 2.3 | 42.9 |
| 4×120 | 12.4 | 1.2 | 1.4 | 2.5 | 2.5 | 48.6 |
| 4×150 | 13.8 | 1.4 | 1.4 | 2.5 | 2.7 | 53.2 |
| 4×185 | 15.3 | 1.6 | 1.4 | 2.5 | 2.8 | 58.1 |
| 4×240 | 17.5 | 1.7 | 1.6 | 2.5 | 3.1 | 64.8 |
| 4×300 | 19.5 | 1.8 | 1.6 | 2.5 | 3.2 | 70.4 |
| 4×400 | 22.6 | 2 | 1.8 | 3.15 | 3.6 | 81.3 |
Packaging
Packing Details : Packing in wooden drum, iron-wooden drum or as customer’s requirement.
Delivery Details : 15-25 days after place an order.
About Us
People’s Cable Group Co., Ltd. Was founded in 2007, with good transport facilities which adjacent to the 310 national highway-Lian Huo highway. Our company had 2 factories(Zhitian factory and Zhulin factory), occupies total area of more than 300,000 square meters, with building area 230,000 square meters. The real capital assets more than 10 million USD, with 630 staff members, 65 of which are professional and technical experts.
Our mainly products as follow:
1–pvc insulated electric wire whatever copper conductor,aluminum conductor, CCA(copper clad aluminum), CCS(copper clad steel).
2–pvc and xlpe insulated power cable with or without armor upto 35kv.
3–rubber cable like welding cable, mine cable, EPR cable and so on.
4–aerial bundled cable(ABC cable) up to 10kv.
5–bare conductor like AAC, AAAC, ACSR, ACAR, ACSR/AW, aluminum clad steel wire, galvanized steel wire, PC steel wire and so on.
Customer Vist
We have a professional sales team with each of them has engaged in this job for 3-10 years, so that we can provide the comprehensive and professional technology for you.
With the perfect quality and after sales service, till now we have exported to more than 80 countries, welcome to visit us and establish win-win business relationship!
Certification
As top rank of the cable supplier in China, we have obtained CCC, ISO9001, ISO14001, OHSAS certificates, passed the SGS and BV test, and our brand "RMJT" be given China famous brand.
FAQ:
I didn’t find the cable which I need in this page?
If you didn’t find the species of cables you need, please contact us directly, we will reply you quickly.
Are you a trading company or manufacture?
RMJT is a professional manufacturer in Henan, China.
What is the MOQ?
Mostly we sell from stock for normal items, you can buy any quantity unless its customed-made.
Can you offer me a free sample?
Yes, after price confirmation, you can require for samples to check our quality.sample is free but the freight charge should be paid.
How long get the sample?
After you pay the freight charge and send us confirmed files, the samples will be ready for delivery in 3-7 days. The samples will be sent to you via express and arrive in 3~5 days
How is your package?
Normally packed with coils and cartons, and wooden/steel wooden drums, other ways can be done according you.
How is the payment?
T/T, L/C is accepted.
What is the lead time for mass production?
Honestly, it depends on the order quantity and the season you place the order.The best record we keep is delivering 10 kilometers cable within a week. Generally speaking, we suggest that you start inquiry two months before the date you would like to get the products at your country.
We are China XLPE 3 Phase Armoured Aluminum Solidal Power Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Electric Cable Products
10kv, 35kv XLPE Insulated Cable, Power Cable
Single Core, 3 Cores, 4 Cores Copper or Aluminium Power Cable, XLPE/PVC Insulated Power Cable.
ISO Ce Approved High Voltage 1 Core 3 Core XLPE 66kv Underground Power Cable Per Meter Price
0.6/1kv Power Aluminum Conductor XLPE Insulated Overhead Aerial Bundle ABC Cable
Thermal Insulation Mineral Compound Insulated Fireproof Cable. Copper Conductor Power Cable.
Popular renmincable Products
4 Core 4mm2 10mm2 95mm2 PVC Insulated Power Cable 0.6/1kv
450/750V Single Core Copper Conductor Building Wire/BV Wire/Ho5V-U Cable
XLPE Insulated PVC Sheathed Single Core Copper Power Cable 95mm2
AAAC 120mm Standards Aluminum Alloy Conductor Steel Reinforced Overhead Electric Powe Wire
ABC Cable Size16sqmm/25sqmm/50sqmm/70sqmm/95sqmm
Twisted Pair Flexible Cable 450-750V Rvs 2 Core PVC Insulated Copper Core Electric Wire
Popular Swa Armoured Cable Products
18/30kv Medium Voltage Single Core Copper XLPE Power Cable
Swa Steel Wire Armoured PVC Sheathed Widely Used Power Cable
Price 3 Phase Armoured XLPE Insulated 4 Core Aluminum Copper Cable
0.6/1kv Copper Core PVC Insulated Swa Armoured Cable 1-Cykydy
BS5467 XLPE Swa Steel Wire Armoured Cable Wiring 25mm Outdoor Power Cable
Kema TUV Certificate Underground Swa Armoured PVC Power Cable
Popular XLPE Insulated Cable Products
Low Voltage PVC/XLPE Insulated Aluminum/Copper Conductor 4*120mm2 ABC Cable
Underground XLPE Insulated Copper Aluminum Conductor Armored Power Cable
XLPE Armoured Power Cable/PVC Power Cable
6kv 185mm2 XLPE Insulated Steel Wire Armored Underground Power Cable
Tags: Electric Cable, renmincable, Swa Armoured Cable, XLPE Insulated Cable