XLPE Insulation Copper Tape Insulation Three Cores Power Cable
XLPE Insulation Copper Tape Insulation Three Cores Power Cable image
Get Latest Price Request a quote
Quick Details
Product Details
Power Cable
Standards
Products can be manufactured according to GB standard, IEC standard, ASTM standard, BS standard and DIN and other standard and customers` specific requirements.
Specification
1. Conductors: Copper or aluminum.
2. Both armored and non-armored type power cables are available.
3. Voltage rating: 0.6/1kV 3.6/6kV 6/10kV 8.7/15kV 26/35kV.
4. PVC or XLPE sheathed.
5. Number of cable cores: One core (Single core), two cores(Double cores), three cores, four cores (Four Equal-section-area cores or three equal-section area cores and one smaller section area neutral core), five cores (Five equal-area cores or three equal-section-area cores and two smaller section area neutral cores).
Characteristics of Cable
1. Max Long-time operating temperature of PVC insulated cable is 70° C, XLPE 90° C
2. Installing temperature of cable should not be less than 0° C
3. Max short-circuit temperature is: PVC not exceed 160° C, XLPE 250° C, Not more than5 Sec.
4. Permitting bending radius cable: Not less than 10 D times (D: External diameter of cable)
5. Perfect chemical stability, resistant against acids, alkali, grease and organic solvents, and flamer retardant.
Number of Cores & Nominal Cross-section Area
Installation:
1. The installation temperature should not over 20º C, If the ambient temperature is lower than 0º C, the cable should be preheated.
2. The bending radius of cable should not less than 8 times.
3. After installantion, the cable should with stand voltage test for 15min. 35kv D. C.
In air:
1. As the single core cable laying in parallel, the distance between the cable’s center is 2 times (for cables which cross section area of conductor ≤ 185mm2) and
90mm (for cables which cross sectional area of conductor≥ 240mm2)
2. Ambient temperature: 30º C
3. Max. Temperature of conductor: 70º C
4. Rating factors of current rating for ambient temperature:
Direct in ground:
1. When the single core cables are installed separately, the distance between the cable’s center is 2 times of the cable diameter.
2. Ambient temperature: 25º C.
3. Max. Temperature of conductor: 70º C.
4. Soil thermour resistivity: 1.0º C. M/w.
5. Depth: 0.7m
6. Rating factors under different ambient temp.:
PVC Insulation Electric Cable
XLPE Insulated electric cable
We are China XLPE Insulation Copper Tape Insulation Three Cores Power Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular 35kv Power Cable Products
35kv XLPE Insulated Power Cable
15kv Mv Medium Voltage 2/0AWG Copper Armoured with UL1072
35kv Swa XLPE Cable Aluminum Conductor
NEMA Wc 74 / Iceass-93-639 35kv 500mcm Power Cabe
1~35kv Medium Voltage 11kv, 24kv, 33kv, 36kv XLPE Cable
Popular huatongcable Products
ACSR, DIN Standard, 95/15mm2 ACSR Conductor
Overhead Triplex Service Drop Pisa Aerial Bundled Cable for Transmission Line
33kv Hv Underground XLPE Insualted Copper Power Cables
6.35/11 Kv Cabo Xhiav 3 X 95 Power Cable
66kv XLPE Insulated 1c 630mm2 Power Cable
Popular Mv Power Cable Products
Medium Voltage Cable 3*240mm2 Swa as Per IEC60502 with Wooden Drums
2022 1*120mm2 2*150mm2 3*185mm2 3*150+1*70mm2 CE Certified Copper Core XLPE Insulated Power Cables
1-35kv XLPE Insulation Mv Power Cable
1~35kv Medium Voltage 6kv 6.6kv 10kv 11kv 12kv 15kv 20kv 24kv 33kv 35kv 36kv XLPE Power Cable
12kv 1 Core or 3 Core Al/XLPE/PVC/Swa/PE (PVC) Underground Cables
Popular Three Cores Power Cable Products
Three Cores with Stranded Alumininum Conductors XLPE Insulated Power Cable
Tags: 35kv Power Cable, huatongcable, Mv Power Cable, Three Cores Power Cable