XLPE/PVC Insulated 3-5 Core Power Cable Copper Conductor
XLPE/PVC Insulated 3-5 Core Power Cable Copper Conductor image
Get Latest Price Request a quote
Quick Details
Product Details
1.Scope of Applications of 3 core power cable
This cable is used in electricity transmission and distribution system of operation frequency at rated voltage of 0.6/1kV,3.6/6kV,6/10kV,8.7/15kV,12/20kV,21/35kV.
2.Executive Standard of 3 core power cable
The product GB/T12706-2008 is manufactured by referring to the standard of IEC502,IEC332-3 etc.
3.Operational Performances of 3 core power cable
1. Operation temperature:Maximum ambient temperature 90°C
2.Short temperature:No more than 250°C
3.Bending radius:no less than 20 times of outer cable diameter for single core;
no less than 15 times of outer cable diameter for multiple cores.
4.Set-up temperature:Must be heated in advance when arrangement is lower than 0°C
5.Arrangement fall:not limited by level fall.
4.Technical data of armoured power cable
N-BV | PVC-insulated fire-resisting cable(wire) |
N-BV V | PVC-insulated and sheathed fire-resisting cable(wire) |
N-V V | PVC-insulated and sheathed fire-resisting power cable(wire) |
N-V V22 | PVC-insulated,steel tape armored,PVC-sheathed fire-resisting power cable |
N-VV32 | PVC-insulated,fine steel wire armored,PVC-sheathed fire-resisting power cable |
N-YJV | XLPE-insulated and PVC sheathed fire-resisting power cable |
N-YJV22 | XLPE insulated, steel tape armored, PVC sheathed fire-resisting power cable |
N-YJV32 | XLPE insulated, fine steel wire armored, PVC sheathed fire-resisting power cable |
N-YJY | XLPE insulated and PE (polyolefin) sheathed fire-resisting power cable |
N-YJY23 | XLPE insulated, steel tape armored, PE (polyolefin) sheathed fire-resisting power cable |
N-YJY33 | XLPE insulated, fine steel wire armored, PE (polyolefin) sheathed fire-resisting power cable |
N-KVV | PVC insulated and PVC sheathed fire-resisting control cable |
N-KVV22 | PVC insulated, steel tape armored, PVC sheathed fire-resisting control cable |
N-KVV32 | PVC insulated, fine steel wire armored, PVC sheathed fire-resisting control cable |
N-KVVP2-22 | PVC insulated, copper tape collectively screened, steel tape armored and PVC sheathed fire-resisting control cable |
N-KYY | PE insulated and PE sheathed fire-resisting control cable |
N-KYJY | XLPE insulated and PE (polyolefin) sheathed fire-resisting control cable |
N-KYJY23 | XLPE insulated, steel tape armored, PE (polyolefin) sheathed fire-resisting control cable |
N-RV | PVC insulated fire-resisting flexible cable |
XLPE Type | Name | Application | |
Cu | Al | ||
Conductor | Conductor | ||
YJV | YJLV | XLPE Insulated, PVC or PE Sheathed Power Cable | For lying indoor, channel and underground. Unable to bear external mechanical force, but bear the traction force during lay. |
YJV | YJLV | ||
YJV22 | YJLV22 | XLPE Insulated, Steel Tape Armored, PVC or PE Sheathed Power Cable | For laying indoor, tunnel, channel and underground. Able to bear external mechanical force, but unable to bear large pulling force. |
YJV23 | YJLV23 | ||
YJV32 | YJLV32 | XLPE Insulated, Fine Steel Wire Armored, PVC or PE Sheathed Power Cable | For lying in shave with large difference of level. Able to bear external mechanical force, and moderate pulling force. |
YJV33 | YJLV33 | ||
YJV42 | YJLV42 | XLPE Insulated, Thick Steel Wire Armored, PVC or PE Sheathed Power Cable | Able to bear positive pressure and pulling force |
We could produce most of the standards cables, such as ASTM, BS, CSA, DIN, GB and IEC Standards, etc.
ISO9001:2008, OHSAS, CCC, TUV Certifications.
People’s Cable Group Co., Ltd, a professional wires and cables manufacturer for 27 years in China. we mainly produce power cables, control cables, aerial overhead cables(ABC, AAC ACSR and AAAC cables) etc. Standards Supported: ASTM, BS, CSA, IEC, DIN and GB etc.
1. Factory: 160000 square meters, available for OEM;
2. Lead time: 5-7 working days after payment received;
3. Authentication: TUV, OHSAS, CCC, ISO9001:2008;
4. Guarantee: 20 years;
5. QC inspection: Strict inspection before delivery;
After-sales Service:
1. All our cables will be tested well in production and before delivery.
2. Please contact us if any problem, we will respond within 24 hours.
We are China XLPE/PVC Insulated 3-5 Core Power Cable Copper Conductor manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Cable Products
ASTM Standard Aluminum Alloy Electric Wire 600mcm 303.8sqmm AAAC Conductor
4X35mm2 4X95mm2 XLPE Armoured Copper Cable for Construction
Ce Approved Low Voltage 0.6/1 Kv LSZH Fire Proof Cable / Flame Resistant Cable
0.6/1kv XLPE Insulation 10mm Aluminium Concentric Cable
XLPE PE PVC Insulated Aluminum Cable Overhead Quadruplex 3*240+240sqmm Service Drop ABC Cable
Bulding Wire Aluminum Conductor Rated Temperature 75, 90oc Type Ser Cable
Popular Power Cable Products
11kv XLPE/PVC Insulated Power/Fire Resistant Cable
Type Shd-Gc, Mining Cable, Cu/Epr/CPE, 3/C, 5kv (ICEA S-75-381/NEMA WC-58)
High Voltage XLPE Insulation Overhead ABC Cable Aluminum Conductor ABC Aerial Bundled Cable
XLPE Insulated Duplex Service Drop - Aluminum Conductor Aerial Bundle Cable
Popular renmincable Products
35mm2 70mm2 0.6 1 Kv Power Cable with Armoured
1 Sq mm Electrical Wire Plastic Insulated Fire-Resistant Control Cable
4mm2 6mm2 PV1-F Xlpo XLPE Solar System Panel Photovoltaic PV Cable
BS 215 Part 2 ACSR Rabbit Conductor
Building Wire UL Strandard Thw Thhn Cable Flexible Cable with Ce Certificate
PVC Insulated Wire Underground Cable Price List Steel Wire Armoured Cable
Popular XLPE Cable Products
Competitive Price Aerial Bundled Conductor Cable
Power Cable 0.6/1kv Copper Conductor XLPE Insulation PVC Sheath for Underground
Control Power Cable XLPE/PVC Insulation Copper Braided Shield Electrical Wire
Sans 1418 Aerial Bundled Cable, Aerial Cable, ABC Wire
35kv Aluminium Plastic Insulation Power Cable
Tags: Cable, Power Cable, renmincable, XLPE Cable