Yjv Yjv22 Yjv32 VV VV22 VV32 PVC/XLPE/Armoured Cable with Low Voltage

China 
                        Yjv Yjv22 Yjv32 VV VV22 VV32 PVC/XLPE/Armoured Cable with Low Voltage
                      manufacture and supplier

Yjv Yjv22 Yjv32 VV VV22 VV32 PVC/XLPE/Armoured Cable with Low Voltage image

Get Latest Price Request a quote

Quick Details

Yjv Yjv22 Yjv32 VV VV22 VV32 PVC/XLPE/Armoured Cable with Low Voltage

low voltage cable

Chang Qing Teng

VV, Yjv…

ISO, CCC, CE, RoHS, UL, VDE

Bare Copper Wire

Round Wire

PVC

PVC

DC & AC

Low and Medium Voltage Cable

Construction, Underground, Industrial, Power Station, Telecommunication

Low Voltage Cable/ PVC Cable/ XLPE Cable/ Armoured

Single/2/3/4/5/6/7/8/10/16 Core…

3.5/4/6/10/16/25/35/50/70/95/120/150/185/240/300/4

IEC 60502-1, BS 7870-6, BS 6622, BS 7835, GB 5023-

Stranded/Solid/Flexible Copper/Aluminum Conductor

XLPE/PVC/PE/PUR

Electric, House Wire, Building Wire…

Copper Wire Screen(Cws), Aluminium Wire Screen(Aws

Steel Tape Armoured (Sta) or Steel Wire Armoured (

Luxing

Non-Fumigation Wooden Drum, Iron-Wooden Drum.

350x160x270,800x350x550,1000x500x600,1200x500x900.

Shandong

8544492100

Product Details

YJV YJV22 YJV32 VV VV22 VV32 PVC/XLPE/Armoured Cable with Low Voltage 

1.Applications
-These cables are used for electricity supply in low voltage installation system.
-They are suitable for installation in indoors and outdoors,in cable ducts, underground, in power and switching stations,
local energy distributions, industrial plants, where there is no risk of mechanical damage.

2.Construction

Conductors
The conductors shall be either of Class 1 or Class 2 of plain  accordance with IEC 60228.

Insulation
PVC Insulation material and thickness shall be as per IEC 60502-1, PVC material shall be Type A as per IEC 60502-1.

Assembly / Inner Covering
The inner coverings may be extruded or lapped. 
Armour
Aluminum/galvanized steel/steel wires applied helically over the Inner Covering as per IEC 60502-1,

 
Outer Sheath
Outer sheath shall be of extruded PVC  as per IEC 60502-1, Polyethylene, Halogen free compound.
Polychloroprene, chlorosulfonated polyethylene or similar polymers.
Fire Performance of Cable Sheaths
Cables can be supplied with special flame retardant PVC outer sheath to comply with the flame test requirements of IEC 60332-3-22,
IEC 60332-3-23 and IEC 60332-3-24, Halogen Free material comply to IEC60754-1/2 and IEC 60684-2.

3.Parameters

Single core(unarmoured)
Nominal Cross Section Diameter of Conductor (Approx.) Nominal Insulation Thickness Nominal Sheath Thickness Overall Diameter (Approx.)
mm^2 mm mm mm mm
1×4 2.3 1 1.4 7.1
1×6 2.8 1 1.4 7.6
1×10 3.6 1 1.4 8.4
1×16 4.5 1 1.4 9.3
1×25 5.6 1.2 1.4 10.8
1×35 6.7 1.2 1.4 11.9
1×50 8 1.4 1.4 13.6
1×70 9.4 1.4 1.4 15.1
1×95 11 1.6 1.5 17.2
1×120 12.4 1.6 1.5 18.7
1×150 13.8 1.8 1.6 20.6
1×185 15.3 2 1.7 22.7
1×240 17.5 2.2 1.8 25.4
1×300 19.5 2.4 1.9 28.0
1×400 22.6 2.6 2.0 31.7
1×500 25.2 2.8 2.1 35.0
1×630 28.3 2.8 2.2 38.3

 

Two cores(unarmoured)
Nominal Cross Section Diameter of Conductor (Approx.) Nominal Insulation Thickness Nominal Sheath Thickness Overall Diameter (Approx.)
mm^2 mm mm mm mm
2×1.5 1.4 0.8 1.8 9.6
2×2.5 1.8 0.8 1.8 10.4
2×4 2.3 1 1.8 12.2
2×6 2.8 1 1.8 13.2
2×10 3.6 1 1.8 14.8
2×16 4.5 1 1.8 16.6
2×25 5.6 1.2 1.8 19.6
2×35 6.7 1.2 1.8 21.8
2×50 8 1.4 1.8 25.2
2×70 9.4 1.4 1.9 28.1
2×95 11 1.6 2.0 32.4
2×120 12.4 1.6 2.1 35.4
2×150 13.8 1.8 2.2 39.2
2×185 15.3 2 2.4 43.3
2×240 17.5 2.2 2.5 48.9
2×300 19.5 2.4 2.7 54.0
2×400 22.6 2.6 2.9 61.5

 

Three cores(unarmoured)
Nominal Cross Section Diameter of Conductor (Approx.) Nominal Insulation Thickness Nominal Sheath Thickness Overall Diameter (Approx.)
mm^2 mm mm mm mm
3×1.5 1.4 0.8 1.8 10.1
3×2.5 1.8 0.8 1.8 10.9
3×4 2.3 1 1.8 12.9
3×6 2.8 1 1.8 13.9
3×10 3.6 1 1.8 15.7
3×16 4.5 1 1.8 17.6
3×25 5.6 1.2 1.8 20.8
3×35 6.7 1.2 1.8 23.2
3×50 8 1.4 1.8 26.9
3×70 9.4 1.4 1.9 30.1
3×95 11 1.6 2.1 34.7
3×120 12.4 1.6 2.2 38.0
3×150 13.8 1.8 2.3 42.1
3×185 15.3 2 2.5 46.5
3×240 17.5 2.2 2.7 52.5
3×300 19.5 2.4 2.8 58.0
3×400 22.6 2.6 3.1 66.1

 

Three cores+1(unarmoured)
Nominal Cross Section Diameter of Conductor (Approx.) Nominal Insulation Thickness Nominal Sheath Thickness Overall Diameter (Approx.)
mm^2 (3)mm (1)mm (3)mm (1)mm mm mm
3x 16/10 4.5 3.6 1 1 1.8 19.0
3x 25/16 5.6 4.5 1.2 1 1.8 22.6
3x 35/16 6.7 4.5 1.2 1 1.8 25.3
3x 50/25 8.0 5.6 1.4 1.2 1.9 29.6
3x 70/35 9.4 6.7 1.4 1.2 2.0 33.2
3x 95/50 11.0 8.0 1.6 1.4 2.2 38.4
3×120/70 12.4 9.4 1.6 1.4 2.3 42.0
3×150/70 13.8 9.4 1.8 1.4 2.5 46.6
3×185/95 15.3 11.0 2 1.6 2.6 51.6
3×240/120 17.5 12.4 2.2 1.6 2.9 58.3
3×300/150 19.5 13.8 2.4 1.8 3.1 64.5
3×400/185 22.6 15.3 2.6 2 3.3 73

 

Four cores(unarmored)
Nominal Cross Section Diameter of Conductor (Approx.) Nominal Insulation Thickness Nominal Sheath Thickness Overall Diameter (Approx.)
mm^2 mm mm mm mm
4×1.5 1.4 0.8 1.8 10.8
4×2.5 1.8 0.8 1.8 11.8
4×4 2.3 1 1.8 14.0
4×6 2.8 1 1.8 15.2
4×10 3.6 1 1.8 17.1
4×16 4.5 1 1.8 19.3
4×25 5.6 1.2 1.8 22.9
4×35 6.7 1.2 1.8 25.6
4×50 8 1.4 1.9 29.9
4×70 9.4 1.4 2.0 33.5
4×95 11 1.6 2.2 38.7
4×120 12.4 1.6 2.3 42.3
4×150 13.8 1.8 2.5 46.9
4×185 15.3 2 2.6 51.9
4×240 17.5 2.2 2.9 58.6
4×300 19.5 2.4 3.1 64.8
4×400 22.6 2.6 3.3 73.8

 

Multi-cores(unarmoured)
Nominal Cross Section Diameter of Conductor (Approx.) Nominal Insulation Thickness Nominal Sheath Thickness Overall Diameter (Approx.)
mm^2 mm mm mm mm
5×1.5 1.4 0.8 1.8 11.7
7×1.5 1.4 0.8 1.8 12.6
10×1.5 1.4 0.8 1.8 15.6
12×1.5 1.4 0.8 1.8 16.1
14×1.5 1.4 0.8 1.8 16.8
19×1.5 1.4 0.8 1.8 18.6
21×1.5 1.4 0.8 1.8 19.5
24×1.5 1.4 0.8 1.8 21.6
30×1.5 1.4 0.8 1.8 22.8
40×1.5 1.4 0.8 1.8 27.7
48×1.5 1.4 0.8 1.9 28.2
61×1.5 1.4 0.8 1.9 30.9
5×2.5 1.8 0.8 1.8 12.8
7×2.5 1.8 0.8 1.8 13.8
10×2.5 1.8 0.8 1.8 17.2
12×2.5 1.8 0.8 1.8 17.7
14×2.5 1.8 0.8 1.8 18.6
19×2.5 1.8 0.8 1.8 20.6
21×2.5 1.8 0.8 1.8 21.6
24×2.5 1.8 0.8 1.8 24.0
30×2.5 1.8 0.8 1.8 25.4
40×2.5 1.8 0.8 2.0 31.1
48×2.5 1.8 0.8 2.0 31.7
61×2.5 1.8 0.8 2.1 34.7

4.Contact us

If you need low voltage cable, medium voltage cable, control cable, rubber cable,
ABC cable, ACSR, underground cable, armoured cable, XLPE cable, PVC cable,

 

We are China Yjv Yjv22 Yjv32 VV VV22 VV32 PVC/XLPE/Armoured Cable with Low Voltage manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular Low Voltage Cable Products

Steel Wire Armoured Cable Cu/Al Conductor XLPE/PVC Insulation PVC Sheath

0.6/1kv XLPE/PVC Electrical Cable, Electric Cable, Power Cable

0.6/1kv Copper Conductor XLPE Insulated Sta/Swa Armoured Underground Low Voltage Power Cable 185mm 4 Core

600/1000V 4 Core 35mm2 Armoured Aluminum Cable

ABC Overhead Cable (Aerial Bundled Conductor)

Power Cable Low Voltage (LV) PVC/XLPE Insulated Armoured

Popular luxingcable Products

4 Core 95mm 120mm 0.6 /1kv Copper XLPE Armoured Underground Power Cable

0.6/1kv XLPE Insulated Cables According to IEC 60502-1

Cable Wire Electrical 1mm 1.5mm 2.5mm 4mm 6mm 10mm 16mm 25mm

Aluminum Conductor PVC Insulted Steel Tape Armoured PVC Sheathed Electrical Cable Vlv22

3X2.5mm Power Cable/Power Cable 3X2.5/3X1.5mm2 Power Cable

Copper Conductor PVC Insulated Steel Tape Armoured Control Cable

Popular PVC Cable Products

Cu/PVC/PVC, Control Cable, 0.6/1 Kv (IEC 60502-1)

Low Voltage 1kv Duplex ABC Cable, Electrical Power Cable

PVC Insulated Shield Copper Electric Wire Control Cable

PVC Insulated Flexible Household Electrical Cable Silicone PTFE Electric Wire for Building and Equipment

PVC Electrical Wire Cable for ASTM/IEC

Control Cable PVC Insulated PVC Sheathed 450/750V

Popular XLPE Cable Products

0.6/1kv PVC Saw Cable 4core 16sqmm

IEC60502 0.6/1kv 120mm2 150mm2 300mm2 Stranded Copper Wires Conductor Aluminum Conductor XLPE Insulation PVC Outer Sheath for Infrastruction

Medium Voltage Copper XLPE Insulated PVC Sheated Power Cable

LV XLPE Power Cable, Low Voltage XLPE Insulated PVC Sheathed Power Cable

Primary Ud Cable, 25 Kv, Al/Tr-XLPE/Neutral/PVC (AEIC CS 8/ICEA S-94-649)

19/33kV XLPE CU 1 Core 120mm2 Aluminum Wire Armoured IEC 60502-2 Power Cable

Tags: , , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION