0.6/1kv CU/XLPE/PVC/STA/PVC Cable
1.Applications
These cables are used for electricity supply in low voltage installation system, They are suitable for installation in indoors and outdoors,
in cable ducts, under ground, in power and switching stations, local energy distributions, industrial plants,
where there is no risk of mechanical damage.
2.Construction
1)Conductors
The conductors shall be either of Class 1 or Class 2 of plain or metal-coated annealed copper or of plain aluminium or aluminium alloy,
or of Class 5 of plain or metal-coated copper in accordance with IEC 60228.
2)Insulation
XLPE material and thickness shall be as per IEC 60502 or BS 5467 rated for 90C continuous operation.
3)Colour Code
Colour Code (1)
1 Core | Red or Black |
2 Cores | Red, Black |
3 Cores | Red, Yellow, Blue |
4 Cores | Red, Yellow, Blue, Black |
5 Cores | Red, Yellow, Blue, Black, Green |
Above 5 Cores | Black Cores with White numerals |
Colour Code (2)
1 Core | Brown or Blue |
2 Cores | Brown, Blue |
3 Cores | Brown, Black, Grey |
4 Cores | Blue, Brown, Black, Grey |
5 Cores | Green/Yellow, Blue, Brown, Black, Grey |
Above 5 Cores | Black Cores with White numerals |
Other colours can be manufactured upon request.
4)Assembly / Inner Covering
The inner coverings may be extruded or lapped. For cables with circular cores, except cables with more than five cores,
a lapped inner covering shall be permitted only if the interstices between the cores are substantially filled.
A suitable binder is permitted before application of an extruded inner covering.
The material is compatible with the insulating material,
The materials used for inner coverings and fillers shall be suitable for the operating temperature of the cable and compatible with
the insulating material.For halogen free cables, the inner covering and fillers shall also be halogen free compound.
5)Armour
Aluminum/galvanized steel/steel wires applied helically over the Inner Covering as per IEC 60502-1,
or double aluminum/steel tapes and copper/tinned copper wire can also be manufactured upon request.
6)Outer Sheath
Outer sheath shall be of extruded PVC Type ST1/ST2 as per IEC 60502-1, Polyethylene type ST3/ST7,
Halogen free compound ST8, Polychloroprene, chlorosulfonated polyethylene or similar polymers, type SE1 are also available on request.
7)Fire Performance of Cable Sheaths
Cables can be supplied with special flame retardant PVC outer sheath to comply with the flame test requirements of IEC 60332-3-22,
IEC 60332-3-23 and IEC 60332-3-24, Halogen Free material comply to IEC60754-1/2 and IEC 60684-2.
3.Cable Parameters
1)Single core low voltage cables (unarmoured)
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation Thickness | Nominal Sheath Thickness | Overall Diameter (Approx.) |
mm^2 | mm | mm | mm | mm |
1×1.5 | 1.4 | 0.7 | 1.4 | 5.6 |
1×2.5 | 1.8 | 0.7 | 1.4 | 6.0 |
1×4 | 2.3 | 0.7 | 1.4 | 6.5 |
1×6 | 2.8 | 0.7 | 1.4 | 7.0 |
1×10 | 3.6 | 0.7 | 1.4 | 7.8 |
1×16 | 4.5 | 0.7 | 1.4 | 8.7 |
1×25 | 5.6 | 0.9 | 1.4 | 10.2 |
1×35 | 6.7 | 0.9 | 1.4 | 11.3 |
1×50 | 8.0 | 1 | 1.4 | 12.8 |
1×70 | 9.4 | 1.1 | 1.4 | 14.4 |
1×95 | 11.0 | 1.1 | 1.5 | 16.1 |
1×120 | 12.4 | 1.2 | 1.5 | 17.8 |
1×150 | 13.8 | 1.4 | 1.6 | 19.8 |
1×185 | 15.3 | 1.6 | 1.6 | 21.8 |
1×240 | 17.5 | 1.7 | 1.7 | 24.4 |
1×300 | 19.5 | 1.8 | 1.8 | 26.7 |
1×400 | 22.6 | 2 | 1.9 | 30.5 |
1×500 | 25.2 | 2.2 | 2.0 | 33.7 |
1×630 | 28.3 | 2.4 | 2.2 | 37.4 |
1×800 | 31.9 | 2.6 | 2.3 | 41.7 |
1×1000 | 35.7 | 2.8 | 2.4 | 46.2 |
2)Two cores low voltage cables (unarmoured)
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation Thickness | Nominal Sheath Thickness | Overall Diameter (Approx.) |
mm^2 | mm | mm | mm | mm |
2×1.5 | 1.4 | 0.7 | 1.8 | 9.2 |
2×2.5 | 1.8 | 0.7 | 1.8 | 10.0 |
2×4 | 2.3 | 0.7 | 1.8 | 11.0 |
2×6 | 2.8 | 0.7 | 1.8 | 12.0 |
2×10 | 3.6 | 0.7 | 1.8 | 13.6 |
2×16 | 4.5 | 0.7 | 1.8 | 15.4 |
2×25 | 5.6 | 0.9 | 1.8 | 18.4 |
2×35 | 6.7 | 0.9 | 1.8 | 20.6 |
2×50 | 8.0 | 1 | 1.8 | 23.6 |
2×70 | 9.4 | 1.1 | 1.8 | 26.8 |
2×95 | 11.0 | 1.1 | 1.9 | 30.2 |
2×120 | 12.4 | 1.2 | 2.0 | 33.7 |
2×150 | 13.8 | 1.4 | 2.2 | 37.5 |
2×185 | 15.3 | 1.6 | 2.3 | 41.6 |
2×240 | 17.5 | 1.7 | 2.5 | 46.7 |
2×300 | 19.5 | 1.8 | 2.6 | 51.4 |
2×400 | 22.6 | 2 | 2.9 | 58.9 |
3)Three cores low voltage cables (unarmoured)
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation Thickness | Nominal Sheath Thickness | Overall Diameter (Approx.) |
mm^2 | mm | mm | mm | mm |
3×1.5 | 1.4 | 0.7 | 1.8 | 9.6 |
3×2.5 | 1.8 | 0.7 | 1.8 | 10.5 |
3×4 | 2.3 | 0.7 | 1.8 | 11.6 |
3×6 | 2.8 | 0.7 | 1.8 | 12.6 |
3×10 | 3.6 | 0.7 | 1.8 | 14.4 |
3×16 | 4.5 | 0.7 | 1.8 | 16.3 |
3×25 | 5.6 | 0.9 | 1.8 | 19.5 |
3×35 | 6.7 | 0.9 | 1.8 | 21.9 |
3×50 | 8.0 | 1 | 1.8 | 25.1 |
3×70 | 9.4 | 1.1 | 1.9 | 28.7 |
3×95 | 11.0 | 1.1 | 2.0 | 32.4 |
3×120 | 12.4 | 1.2 | 2.1 | 36.1 |
3×150 | 13.8 | 1.4 | 2.3 | 40.3 |
3×185 | 15.3 | 1.6 | 2.4 | 44.6 |
3×240 | 17.5 | 1.7 | 2.6 | 50.2 |
3×300 | 19.5 | 1.8 | 2.7 | 55.2 |
3×400 | 22.6 | 2 | 3.0 | 63.3 |
4)Three cores+1 low voltage cables (unarmoured)
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation Thickness | Nominal Sheath Thickness | Overall Diameter (Approx.) | ||
mm^2 | (3)mm | (1)mm | (3)mm | (1)mm | mm | mm |
3x 16/10 | 4.5 | 3.6 | 0.7 | 0.7 | 1.8 | 17.5 |
3x 25/16 | 5.6 | 4.5 | 0.9 | 0.7 | 1.8 | 21.2 |
3x 35/16 | 6.7 | 4.5 | 0.9 | 0.7 | 1.8 | 23.8 |
3x 50/25 | 8 | 5.6 | 1 | 0.9 | 1.8 | 27.5 |
3x 70/35 | 9.4 | 6.7 | 1.1 | 0.9 | 2.0 | 31.7 |
3x 95/50 | 11 | 8 | 1.1 | 1 | 2.1 | 35.8 |
3×120/70 | 12.4 | 9.4 | 1.2 | 1.1 | 2.3 | 39.9 |
3×150/70 | 13.8 | 9.4 | 1.4 | 1.1 | 2.4 | 44.6 |
3×185/95 | 15.3 | 11 | 1.6 | 1.1 | 2.6 | 49.5 |
3×240/120 | 17.5 | 12.4 | 1.7 | 1.2 | 2.8 | 55.7 |
3×300/150 | 19.5 | 13.8 | 1.8 | 1.4 | 3.0 | 61.4 |
3×400/185 | 22.6 | 15.3 | 2 | 1.6 | 3.2 | 70.4 |
5)Four cores low voltage cables (unarmoured)
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation Thickness | Nominal Sheath Thickness | Overall Diameter (Approx.) |
mm^2 | mm | mm | mm | mm |
4×1.5 | 1.4 | 0.7 | 1.8 | 10.4 |
4×2.5 | 1.8 | 0.7 | 1.8 | 11.3 |
4×4 | 2.3 | 0.7 | 1.8 | 12.5 |
4×6 | 2.8 | 0.7 | 1.8 | 13.7 |
4×10 | 3.6 | 0.7 | 1.8 | 15.7 |
4×16 | 4.5 | 0.7 | 1.8 | 17.8 |
4×25 | 5.6 | 0.9 | 1.8 | 21.5 |
4×35 | 6.7 | 0.9 | 1.8 | 24.1 |
4×50 | 8.0 | 1 | 1.8 | 27.8 |
4×70 | 9.4 | 1.1 | 2.0 | 32.0 |
4×95 | 11.0 | 1.1 | 2.1 | 36.1 |
4×120 | 12.4 | 1.2 | 2.3 | 40.2 |
4×150 | 13.8 | 1.4 | 2.4 | 44.9 |
4×185 | 15.3 | 1.6 | 2.6 | 49.8 |
4×240 | 17.5 | 1.7 | 2.8 | 56.0 |
4×300 | 19.5 | 1.8 | 3.0 | 61.7 |
4×400 | 22.6 | 2 | 3.2 | 70.7 |
6)Multi-cores low voltage cables(unarmoured)
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation Thickness | Nominal Sheath Thickness | Overall Diameter (Approx.) |
mm^2 | mm | mm | mm | mm |
5×1.5 | 1.4 | 0.7 | 1.8 | 11.2 |
7×1.5 | 1.4 | 0.7 | 1.8 | 12.0 |
10×1.5 | 1.4 | 0.7 | 1.8 | 14.8 |
12×1.5 | 1.4 | 0.7 | 1.8 | 15.2 |
14×1.5 | 1.4 | 0.7 | 1.8 | 16.0 |
19×1.5 | 1.4 | 0.7 | 1.8 | 17.6 |
21×1.5 | 1.4 | 0.7 | 1.8 | 18.4 |
24×1.5 | 1.4 | 0.7 | 1.8 | 20.4 |
30×1.5 | 1.4 | 0.7 | 1.8 | 21.6 |
40×1.5 | 1.4 | 0.7 | 1.8 | 26.0 |
48×1.5 | 1.4 | 0.7 | 1.8 | 26.4 |
61×1.5 | 1.4 | 0.7 | 1.9 | 29.0 |
5×2.5 | 1.8 | 0.7 | 1.8 | 12.2 |
7×2.5 | 1.8 | 0.7 | 1.8 | 13.2 |
10×2.5 | 1.8 | 0.7 | 1.8 | 16.4 |
12×2.5 | 1.8 | 0.7 | 1.8 | 16.9 |
14×2.5 | 1.8 | 0.7 | 1.8 | 17.7 |
19×2.5 | 1.8 | 0.7 | 1.8 | 19.6 |
21×2.5 | 1.8 | 0.7 | 1.8 | 20.6 |
24×2.5 | 1.8 | 0.7 | 1.8 | 22.8 |
30×2.5 | 1.8 | 0.7 | 1.8 | 24.1 |
40×2.5 | 1.8 | 0.7 | 1.9 | 29.4 |
48×2.5 | 1.8 | 0.7 | 1.9 | 29.9 |
61×2.5 | 1.8 | 0.7 | 2.0 | 32.8 |
7)Single core low voltage cables ( aluminum wire armoured)
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation thickness | Nominal Inner Covering thickness | Nominal Alum Wire dia. | Nominal Sheath thickness | Overall Diameter (Approx.) |
mm^2 | mm | mm | mm | mm | mm | mm |
1×4 | 2.3 | 0.7 | 1.0 | 0.8 | 1.8 | 10.9 |
1×6 | 2.8 | 0.7 | 1.0 | 0.8 | 1.8 | 11.4 |
1×10 | 3.6 | 0.7 | 1.0 | 0.8 | 1.8 | 12.2 |
1×16 | 4.5 | 0.7 | 1.0 | 0.8 | 1.8 | 13.1 |
1×25 | 5.6 | 0.9 | 1.0 | 0.8 | 1.8 | 14.6 |
1×35 | 6.7 | 0.9 | 1.0 | 1.25 | 1.8 | 16.6 |
1×50 | 8.0 | 1 | 1.0 | 1.25 | 1.8 | 18.1 |
1×70 | 9.4 | 1.1 | 1.0 | 1.25 | 1.8 | 19.7 |
1×95 | 11.0 | 1.1 | 1.0 | 1.6 | 1.8 | 22.0 |
1×120 | 12.4 | 1.2 | 1.0 | 1.6 | 1.8 | 23.6 |
1×150 | 13.8 | 1.4 | 1.0 | 1.6 | 1.8 | 25.4 |
1×185 | 15.3 | 1.6 | 1.0 | 1.6 | 1.8 | 27.4 |
1×240 | 17.5 | 1.7 | 1.0 | 1.6 | 1.9 | 29.9 |
1×300 | 19.5 | 1.8 | 1.0 | 2.0 | 2.0 | 33.1 |
1×400 | 22.6 | 2 | 1.2 | 2.0 | 2.2 | 37.3 |
1×500 | 25.2 | 2.2 | 1.2 | 2.0 | 2.3 | 40. |
8)Two cores low voltage cables (Galvanized steel wire armoured)
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation thickness | Nominal Inner Covering thickness | Nominal Steel Wire dia. | Nominal Sheath thickness | Overall Diameter (Approx.) |
mm^2 | mm | mm | mm | mm | mm | mm |
2×1.5 | 1.4 | 0.7 | 1.0 | 0.8 | 1.8 | 12.8 |
2×2.5 | 1.8 | 0.7 | 1.0 | 0.8 | 1.8 | 13.6 |
2×4 | 2.3 | 0.7 | 1.0 | 0.8 | 1.8 | 14.6 |
2×6 | 2.8 | 0.7 | 1.0 | 1.25 | 1.8 | 16.5 |
2×10 | 3.6 | 0.7 | 1.0 | 1.25 | 1.8 | 18.1 |
2×16 | 4.5 | 0.7 | 1.0 | 1.25 | 1.8 | 19.9 |
2×25 | 5.6 | 0.9 | 1.0 | 1.6 | 1.8 | 23.6 |
2×35 | 6.7 | 0.9 | 1.0 | 1.6 | 1.8 | 25.8 |
2×50 | 8.0 | 1 | 1.0 | 1.6 | 1.9 | 29.0 |
2×70 | 9.4 | 1.1 | 1.0 | 2.0 | 2.0 | 33.2 |
2×95 | 11.0 | 1.1 | 1.2 | 2.0 | 2.1 | 37.1 |
2×120 | 12.4 | 1.2 | 1.2 | 2.0 | 2.3 | 40.5 |
2×150 | 13.8 | 1.4 | 1.2 | 2.5 | 2.4 | 45.4 |
2×185 | 15.3 | 1.6 | 1.4 | 2.5 | 2.6 | 49.9 |
2×240 | 17.5 | 1.7 | 1.4 | 2.5 | 2.7 | 55.1 |
2×300 | 19.5 | 1.8 | 1.6 | 2.5 | 2.9 | 60.2 |
2×400 | 22.6 | 2 | 1.6 | 2.5 | 3.1 | 67.7 |
9)Three cores low voltage cables (Galvanized steel wire armoured)
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation thickness | Nominal Inner Covering thickness | Nominal Steel Wire dia. | Nominal Sheath thickness | Overall Diameter (Approx.) |
mm^2 | mm | mm | mm | mm | mm | mm |
3×1.5 | 1.4 | 0.7 | 1.0 | 0.8 | 1.8 | 13.2 |
3×2.5 | 1.8 | 0.7 | 1.0 | 0.8 | 1.8 | 14.1 |
3×4 | 2.3 | 0.7 | 1.0 | 0.8 | 1.8 | 15.2 |
3×6 | 2.8 | 0.7 | 1.0 | 1.25 | 1.8 | 17.1 |
3×10 | 3.6 | 0.7 | 1.0 | 1.25 | 1.8 | 18.9 |
3×16 | 4.5 | 0.7 | 1.0 | 1.25 | 1.8 | 20.8 |
3×25 | 5.6 | 0.9 | 1.0 | 1.6 | 1.8 | 24.7 |
3×35 | 6.7 | 0.9 | 1.0 | 1.6 | 1.8 | 27.2 |
3×50 | 8.0 | 1 | 1.0 | 1.6 | 1.9 | 30.6 |
3×70 | 9.4 | 1.1 | 1.0 | 2.0 | 2.1 | 35.2 |
3×95 | 11.0 | 1.1 | 1.2 | 2.0 | 2.2 | 39.3 |
3×120 | 12.4 | 1.2 | 1.2 | 2.0 | 2.3 | 43.0 |
3×150 | 13.8 | 1.4 | 1.4 | 2.5 | 2.5 | 48.6 |
3×185 | 15.3 | 1.6 | 1.4 | 2.5 | 2.7 | 53.0 |
3×240 | 17.5 | 1.7 | 1.4 | 2.5 | 2.8 | 58.5 |
3×300 | 19.5 | 1.8 | 1.6 | 2.5 | 3.0 | 64.0 |
3×400 | 22.6 | 2 | 1.6 | 3.15 | 3.3 | 73.5 |
10)Three cores+1 low voltage cables (Galvanized steel wire armoured)
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation thickness | Nominal Inner Covering thickness | Nominal Steel Wire dia. | Nominal Sheath thickness | Overall Diameter (Approx.) | ||
mm^2 | (3) mm | (1) mm | (3) mm | (1) mm | mm | mm | mm | mm |
3x 16/10 | 4.5 | 3.6 | 0.7 | 0.7 | 1 | 1.6 | 1.8 | 22.7 |
3x 25/16 | 5.6 | 4.5 | 0.9 | 0.7 | 1 | 1.6 | 1.8 | 26.5 |
3x 35/16 | 6.7 | 4.5 | 0.9 | 0.7 | 1 | 1.6 | 1.9 | 29 |
3x 50/25 | 8.0 | 5.6 | 1 | 0.9 | 1 | 1.6 | 2.1 | 33 |
3x 70/35 | 9.4 | 6.7 | 1.1 | 0.9 | 1.2 | 2 | 2.2 | 38 |
3x 95/50 | 11.0 | 8.0 | 1.1 | 1 | 1.2 | 2 | 2.3 | 42.4 |
3×120/70 | 12.4 | 9.4 | 1.2 | 1.1 | 1.2 | 2 | 2.5 | 48.0 |
3×150/70 | 13.8 | 9.4 | 1.4 | 1.1 | 1.4 | 2.5 | 2.7 | 52 |
3×185/95 | 15.3 | 11.0 | 1.6 | 1.1 | 1.4 | 2.5 | 2.8 | 57.2 |
3×240/120 | 17.5 | 12.4 | 1.7 | 1.2 | 1.6 | 2.5 | 3.1 | 64 |
3×300/150 | 19.5 | 13.8 | 1.8 | 1.4 | 1.6 | 2.5 | 3.2 | 69.8 |
3×400/185 | 22.6 | 15.3 | 2 | 1.6 | 1.6 | 3.15 | 3.6 | 78.6 |
11)Four cores low voltage cables (Galvanized steel wire armoured)
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation thickness | Nominal Inner Covering thickness | Nominal Steel Wire dia. | Nominal Sheath thickness | Overall Diameter (Approx.) |
mm^2 | mm | mm | mm | mm | mm | mm |
4×1.5 | 1.4 | 0.7 | 1.0 | 0.8 | 1.8 | 14.0 |
4×2.5 | 1.8 | 0.7 | 1.0 | 0.8 | 1.8 | 14.9 |
4×4 | 2.3 | 0.7 | 1.0 | 1.25 | 1.8 | 17.0 |
4×6 | 2.8 | 0.7 | 1.0 | 1.25 | 1.8 | 18.2 |
4×10 | 3.6 | 0.7 | 1.0 | 1.25 | 1.8 | 20.2 |
4×16 | 4.5 | 0.7 | 1.0 | 1.6 | 1.8 | 23.0 |
4×25 | 5.6 | 0.9 | 1.0 | 1.6 | 1.8 | 26.7 |
4×35 | 6.7 | 0.9 | 1.0 | 1.6 | 1.9 | 29.5 |
4×50 | 8.0 | 1 | 1.0 | 2.0 | 2.1 | 34.2 |
4×70 | 9.4 | 1.1 | 1.2 | 2.0 | 2.2 | 38.8 |
4×95 | 11.0 | 1.1 | 1.2 | 2.0 | 2.3 | 42.9 |
4×120 | 12.4 | 1.2 | 1.4 | 2.5 | 2.5 | 48.6 |
4×150 | 13.8 | 1.4 | 1.4 | 2.5 | 2.7 | 53.2 |
4×185 | 15.3 | 1.6 | 1.4 | 2.5 | 2.8 | 58.1 |
4×240 | 17.5 | 1.7 | 1.6 | 2.5 | 3.1 | 64.8 |
4×300 | 19.5 | 1.8 | 1.6 | 2.5 | 3.2 | 70.4 |
4×400 | 22.6 | 2 | 1.8 | 3.15 | 3.6 | 81.3 |
We are China 0.6/1kv Cu/XLPE/PVC/Sta/PVC Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Armoured Cable Products
Low Volatge PVC Insulated Cable
Copper XLPE PVC Low Voltage Power Cable 0.6 / 1 Kv
LV Underground 18/36kv Single Core Copper, 300mm2 DIN VDE 0276-620
Flexible Cable Silicone Rubber Insulated Heat Fire Resisting Cable
Copper Conductor PVC Insulted Steel Tape Armoured PVC Sheathed Electrical Cable VV22
Popular Cu/XLPE/PVC/Sta/PVC Cable Products
Popular luxingcable Products
Good Price Low Voltage ABC Aluminum Conductor XLPE Insulated Family Cable
Manufactures Direct Supply Low Voltage Armoured Power Cable with PVC Insulation
2018 Trending Products 0.6/1kv Underground Cable Wire Electrical with Low Price
3X2.5mm Power Cable/Power Cable 3X2.5/3X1.5mm2 Power Cable
4mm PVC Insulated Copper Wire Cable 25 Sq mm Copper Core PVC Insulated Coated Electrical Wire
Popular Steel Tape Armoured Cable Products
33kv Single Core 500sqmm Copper Conductor Armoured Power Cable
11kv Al XLPE Armoured S/C 240sqmm
High Quality Steel Tape Armoured Cable/Sta Cable
0.6/1kv 4 Core PVC/XLPE Insulated Sta Steel Tape Armoured Underground Aluminum Power Cable 50mm2
600/1000V Aluminum 3 Core 25mm Galvanized Steel Tape Armoured Cable
Steel Tape Armoured Power Cable (STA Cable)
Tags: Armoured Cable, Cu/XLPE/PVC/Sta/PVC Cable, luxingcable, Steel Tape Armoured Cable