0.6/1kv Cu/XLPE/PVC/Sta/PVC Cable

China 
                        0.6/1kv Cu/XLPE/PVC/Sta/PVC Cable
                      manufacture and supplier

0.6/1kv Cu/XLPE/PVC/Sta/PVC Cable image

Get Latest Price Request a quote

Quick Details

0.6/1kv Cu/XLPE/PVC/Sta/PVC Cable

CU/XLPE/PVC/STA/PVC Cable

Luxing Cables

Low Voltage Cables

ISO, CCC, CE, RoHS

Bare Copper Wire

Round Wire

PVC

XLPE

DC & AC

Low and Medium Voltage Cable

Construction, Underground, Industrial, Power Station

1.5-800mm2

Steel Tape Armoured,Steel Wire Armoured

IEC, BS, VDE, GB/T

CHANG QING TENG

Wooden Drum, Steel Wooden Drum, Steel Iron Drum

0.6/1kv

Dezhou, Shandong

8544492100

Product Details

0.6/1kv CU/XLPE/PVC/STA/PVC Cable

1.Applications

These cables are used for electricity supply in low voltage installation system, They are suitable for installation in indoors and outdoors,
in cable ducts, under ground, in power and switching stations, local energy distributions, industrial plants,
where there is no risk of mechanical damage.

2.Construction

1)Conductors

The conductors shall be either of Class 1 or Class 2 of plain or metal-coated annealed copper or of plain aluminium or aluminium alloy, 

or of Class 5 of plain or metal-coated copper in accordance with IEC 60228.

2)Insulation

XLPE material and thickness shall be as per IEC 60502 or BS 5467 rated for 90C continuous operation.

3)Colour Code

Colour Code (1)

1 Core Red or Black
2 Cores Red, Black
3 Cores Red, Yellow, Blue
4 Cores Red, Yellow, Blue, Black
5 Cores Red, Yellow, Blue, Black, Green
Above 5 Cores Black Cores with White numerals

Colour Code (2)

1 Core Brown or Blue
2 Cores Brown, Blue
3 Cores Brown, Black, Grey
4 Cores Blue, Brown, Black, Grey
5 Cores Green/Yellow, Blue, Brown, Black, Grey
Above 5 Cores Black Cores with White numerals

Other colours can be manufactured upon request.

4)Assembly / Inner Covering

The inner coverings may be extruded or lapped. For cables with circular cores, except cables with more than five cores,
a lapped inner covering shall be permitted only if the interstices between the cores are substantially filled.
A suitable binder is permitted before application of an extruded inner covering.
The material is compatible with the insulating material,
The materials used for inner coverings and fillers shall be suitable for the operating temperature of the cable and compatible with
the insulating material.For halogen free cables, the inner covering and fillers shall also be halogen free compound.

5)Armour

Aluminum/galvanized steel/steel wires applied helically over the Inner Covering as per IEC 60502-1,
or double aluminum/steel tapes and copper/tinned copper wire can also be manufactured upon request.

6)Outer Sheath

Outer sheath shall be of extruded PVC Type ST1/ST2 as per IEC 60502-1, Polyethylene type ST3/ST7,
Halogen free compound ST8, Polychloroprene, chlorosulfonated polyethylene or similar polymers, type SE1 are also available on request.

7)Fire Performance of Cable Sheaths

Cables can be supplied with special flame retardant PVC outer sheath to comply with the flame test requirements of IEC 60332-3-22,
IEC 60332-3-23 and IEC 60332-3-24, Halogen Free material comply to IEC60754-1/2 and IEC 60684-2.

3.Cable Parameters

1)Single core low voltage cables (unarmoured)

Nominal Cross Section Diameter of Conductor (Approx.) Nominal Insulation Thickness Nominal Sheath Thickness Overall Diameter (Approx.)
mm^2 mm mm mm mm
1×1.5 1.4 0.7 1.4 5.6
1×2.5 1.8 0.7 1.4 6.0
1×4 2.3 0.7 1.4 6.5
1×6 2.8 0.7 1.4 7.0
1×10 3.6 0.7 1.4 7.8
1×16 4.5 0.7 1.4 8.7
1×25 5.6 0.9 1.4 10.2
1×35 6.7 0.9 1.4 11.3
1×50 8.0 1 1.4 12.8
1×70 9.4 1.1 1.4 14.4
1×95 11.0 1.1 1.5 16.1
1×120 12.4 1.2 1.5 17.8
1×150 13.8 1.4 1.6 19.8
1×185 15.3 1.6 1.6 21.8
1×240 17.5 1.7 1.7 24.4
1×300 19.5 1.8 1.8 26.7
1×400 22.6 2 1.9 30.5
1×500 25.2 2.2 2.0 33.7
1×630 28.3 2.4 2.2 37.4
1×800 31.9 2.6 2.3 41.7
1×1000 35.7 2.8 2.4 46.2

2)Two cores low voltage cables (unarmoured)

Nominal Cross Section Diameter of Conductor (Approx.) Nominal Insulation Thickness Nominal Sheath Thickness Overall Diameter (Approx.)
mm^2 mm mm mm mm
2×1.5 1.4 0.7 1.8 9.2
2×2.5 1.8 0.7 1.8 10.0
2×4 2.3 0.7 1.8 11.0
2×6 2.8 0.7 1.8 12.0
2×10 3.6 0.7 1.8 13.6
2×16 4.5 0.7 1.8 15.4
2×25 5.6 0.9 1.8 18.4
2×35 6.7 0.9 1.8 20.6
2×50 8.0 1 1.8 23.6
2×70 9.4 1.1 1.8 26.8
2×95 11.0 1.1 1.9 30.2
2×120 12.4 1.2 2.0 33.7
2×150 13.8 1.4 2.2 37.5
2×185 15.3 1.6 2.3 41.6
2×240 17.5 1.7 2.5 46.7
2×300 19.5 1.8 2.6 51.4
2×400 22.6 2 2.9 58.9

3)Three cores low voltage cables (unarmoured)

Nominal Cross Section Diameter of Conductor (Approx.) Nominal Insulation Thickness Nominal Sheath Thickness Overall Diameter (Approx.)
mm^2 mm mm mm mm
3×1.5 1.4 0.7 1.8 9.6
3×2.5 1.8 0.7 1.8 10.5
3×4 2.3 0.7 1.8 11.6
3×6 2.8 0.7 1.8 12.6
3×10 3.6 0.7 1.8 14.4
3×16 4.5 0.7 1.8 16.3
3×25 5.6 0.9 1.8 19.5
3×35 6.7 0.9 1.8 21.9
3×50 8.0 1 1.8 25.1
3×70 9.4 1.1 1.9 28.7
3×95 11.0 1.1 2.0 32.4
3×120 12.4 1.2 2.1 36.1
3×150 13.8 1.4 2.3 40.3
3×185 15.3 1.6 2.4 44.6
3×240 17.5 1.7 2.6 50.2
3×300 19.5 1.8 2.7 55.2
3×400 22.6 2 3.0 63.3

4)Three cores+1 low voltage cables (unarmoured)

Nominal Cross Section Diameter of Conductor (Approx.) Nominal Insulation Thickness Nominal Sheath Thickness Overall Diameter (Approx.)
mm^2 (3)mm (1)mm (3)mm (1)mm mm mm
3x 16/10 4.5 3.6 0.7 0.7 1.8 17.5
3x 25/16 5.6 4.5 0.9 0.7 1.8 21.2
3x 35/16 6.7 4.5 0.9 0.7 1.8 23.8
3x 50/25 8 5.6 1 0.9 1.8 27.5
3x 70/35 9.4 6.7 1.1 0.9 2.0 31.7
3x 95/50 11 8 1.1 1 2.1 35.8
3×120/70 12.4 9.4 1.2 1.1 2.3 39.9
3×150/70 13.8 9.4 1.4 1.1 2.4 44.6
3×185/95 15.3 11 1.6 1.1 2.6 49.5
3×240/120 17.5 12.4 1.7 1.2 2.8 55.7
3×300/150 19.5 13.8 1.8 1.4 3.0 61.4
3×400/185 22.6 15.3 2 1.6 3.2 70.4

5)Four cores low voltage cables (unarmoured)

Nominal Cross Section Diameter of Conductor (Approx.) Nominal Insulation Thickness Nominal Sheath Thickness Overall Diameter (Approx.)
mm^2 mm mm mm mm
4×1.5 1.4 0.7 1.8 10.4
4×2.5 1.8 0.7 1.8 11.3
4×4 2.3 0.7 1.8 12.5
4×6 2.8 0.7 1.8 13.7
4×10 3.6 0.7 1.8 15.7
4×16 4.5 0.7 1.8 17.8
4×25 5.6 0.9 1.8 21.5
4×35 6.7 0.9 1.8 24.1
4×50 8.0 1 1.8 27.8
4×70 9.4 1.1 2.0 32.0
4×95 11.0 1.1 2.1 36.1
4×120 12.4 1.2 2.3 40.2
4×150 13.8 1.4 2.4 44.9
4×185 15.3 1.6 2.6 49.8
4×240 17.5 1.7 2.8 56.0
4×300 19.5 1.8 3.0 61.7
4×400 22.6 2 3.2 70.7

6)Multi-cores low voltage cables(unarmoured)

Nominal Cross Section Diameter of Conductor (Approx.) Nominal Insulation Thickness Nominal Sheath Thickness Overall Diameter (Approx.)
mm^2 mm mm mm mm
5×1.5 1.4 0.7 1.8 11.2
7×1.5 1.4 0.7 1.8 12.0
10×1.5 1.4 0.7 1.8 14.8
12×1.5 1.4 0.7 1.8 15.2
14×1.5 1.4 0.7 1.8 16.0
19×1.5 1.4 0.7 1.8 17.6
21×1.5 1.4 0.7 1.8 18.4
24×1.5 1.4 0.7 1.8 20.4
30×1.5 1.4 0.7 1.8 21.6
40×1.5 1.4 0.7 1.8 26.0
48×1.5 1.4 0.7 1.8 26.4
61×1.5 1.4 0.7 1.9 29.0
5×2.5 1.8 0.7 1.8 12.2
7×2.5 1.8 0.7 1.8 13.2
10×2.5 1.8 0.7 1.8 16.4
12×2.5 1.8 0.7 1.8 16.9
14×2.5 1.8 0.7 1.8 17.7
19×2.5 1.8 0.7 1.8 19.6
21×2.5 1.8 0.7 1.8 20.6
24×2.5 1.8 0.7 1.8 22.8
30×2.5 1.8 0.7 1.8 24.1
40×2.5 1.8 0.7 1.9 29.4
48×2.5 1.8 0.7 1.9 29.9
61×2.5 1.8 0.7 2.0 32.8

7)Single core low voltage cables ( aluminum wire armoured)

Nominal Cross Section Diameter of Conductor (Approx.) Nominal Insulation thickness Nominal Inner Covering thickness Nominal Alum Wire dia. Nominal Sheath thickness Overall Diameter (Approx.)
mm^2 mm mm mm mm mm mm
1×4 2.3 0.7 1.0 0.8 1.8 10.9
1×6 2.8 0.7 1.0 0.8 1.8 11.4
1×10 3.6 0.7 1.0 0.8 1.8 12.2
1×16 4.5 0.7 1.0 0.8 1.8 13.1
1×25 5.6 0.9 1.0 0.8 1.8 14.6
1×35 6.7 0.9 1.0 1.25 1.8 16.6
1×50 8.0 1 1.0 1.25 1.8 18.1
1×70 9.4 1.1 1.0 1.25 1.8 19.7
1×95 11.0 1.1 1.0 1.6 1.8 22.0
1×120 12.4 1.2 1.0 1.6 1.8 23.6
1×150 13.8 1.4 1.0 1.6 1.8 25.4
1×185 15.3 1.6 1.0 1.6 1.8 27.4
1×240 17.5 1.7 1.0 1.6 1.9 29.9
1×300 19.5 1.8 1.0 2.0 2.0 33.1
1×400 22.6 2 1.2 2.0 2.2 37.3
1×500 25.2 2.2 1.2 2.0 2.3 40.

8)Two cores low voltage cables (Galvanized steel wire armoured)

Nominal Cross Section Diameter of Conductor (Approx.) Nominal Insulation thickness Nominal Inner Covering thickness Nominal Steel Wire dia. Nominal Sheath thickness Overall Diameter (Approx.)
mm^2 mm mm mm mm mm mm
2×1.5 1.4 0.7 1.0 0.8 1.8 12.8
2×2.5 1.8 0.7 1.0 0.8 1.8 13.6
2×4 2.3 0.7 1.0 0.8 1.8 14.6
2×6 2.8 0.7 1.0 1.25 1.8 16.5
2×10 3.6 0.7 1.0 1.25 1.8 18.1
2×16 4.5 0.7 1.0 1.25 1.8 19.9
2×25 5.6 0.9 1.0 1.6 1.8 23.6
2×35 6.7 0.9 1.0 1.6 1.8 25.8
2×50 8.0 1 1.0 1.6 1.9 29.0
2×70 9.4 1.1 1.0 2.0 2.0 33.2
2×95 11.0 1.1 1.2 2.0 2.1 37.1
2×120 12.4 1.2 1.2 2.0 2.3 40.5
2×150 13.8 1.4 1.2 2.5 2.4 45.4
2×185 15.3 1.6 1.4 2.5 2.6 49.9
2×240 17.5 1.7 1.4 2.5 2.7 55.1
2×300 19.5 1.8 1.6 2.5 2.9 60.2
2×400 22.6 2 1.6 2.5 3.1 67.7

9)Three cores low voltage cables (Galvanized steel wire armoured)

Nominal Cross Section Diameter of Conductor (Approx.) Nominal Insulation thickness Nominal Inner Covering thickness Nominal Steel Wire dia. Nominal Sheath thickness Overall Diameter (Approx.)
mm^2 mm mm mm mm mm mm
3×1.5 1.4 0.7 1.0 0.8 1.8 13.2
3×2.5 1.8 0.7 1.0 0.8 1.8 14.1
3×4 2.3 0.7 1.0 0.8 1.8 15.2
3×6 2.8 0.7 1.0 1.25 1.8 17.1
3×10 3.6 0.7 1.0 1.25 1.8 18.9
3×16 4.5 0.7 1.0 1.25 1.8 20.8
3×25 5.6 0.9 1.0 1.6 1.8 24.7
3×35 6.7 0.9 1.0 1.6 1.8 27.2
3×50 8.0 1 1.0 1.6 1.9 30.6
3×70 9.4 1.1 1.0 2.0 2.1 35.2
3×95 11.0 1.1 1.2 2.0 2.2 39.3
3×120 12.4 1.2 1.2 2.0 2.3 43.0
3×150 13.8 1.4 1.4 2.5 2.5 48.6
3×185 15.3 1.6 1.4 2.5 2.7 53.0
3×240 17.5 1.7 1.4 2.5 2.8 58.5
3×300 19.5 1.8 1.6 2.5 3.0 64.0
3×400 22.6 2 1.6 3.15 3.3 73.5

10)Three cores+1 low voltage cables (Galvanized steel wire armoured)

Nominal Cross Section Diameter of Conductor (Approx.) Nominal Insulation thickness Nominal Inner Covering thickness Nominal Steel Wire dia. Nominal Sheath thickness Overall Diameter (Approx.)
mm^2 (3) mm (1) mm (3) mm (1) mm mm mm mm mm
3x 16/10 4.5 3.6 0.7 0.7 1 1.6 1.8 22.7
3x 25/16 5.6 4.5 0.9 0.7 1 1.6 1.8 26.5
3x 35/16 6.7 4.5 0.9 0.7 1 1.6 1.9 29
3x 50/25 8.0 5.6 1 0.9 1 1.6 2.1 33
3x 70/35 9.4 6.7 1.1 0.9 1.2 2 2.2 38
3x 95/50 11.0 8.0 1.1 1 1.2 2 2.3 42.4
3×120/70 12.4 9.4 1.2 1.1 1.2 2 2.5 48.0
3×150/70 13.8 9.4 1.4 1.1 1.4 2.5 2.7 52
3×185/95 15.3 11.0 1.6 1.1 1.4 2.5 2.8 57.2
3×240/120 17.5 12.4 1.7 1.2 1.6 2.5 3.1 64
3×300/150 19.5 13.8 1.8 1.4 1.6 2.5 3.2 69.8
3×400/185 22.6 15.3 2 1.6 1.6 3.15 3.6 78.6

11)Four cores low voltage cables (Galvanized steel wire armoured)

Nominal Cross Section Diameter of Conductor (Approx.) Nominal Insulation thickness Nominal Inner Covering thickness Nominal Steel Wire dia. Nominal Sheath thickness Overall Diameter (Approx.)
mm^2 mm mm mm mm mm mm
4×1.5 1.4 0.7 1.0 0.8 1.8 14.0
4×2.5 1.8 0.7 1.0 0.8 1.8 14.9
4×4 2.3 0.7 1.0 1.25 1.8 17.0
4×6 2.8 0.7 1.0 1.25 1.8 18.2
4×10 3.6 0.7 1.0 1.25 1.8 20.2
4×16 4.5 0.7 1.0 1.6 1.8 23.0
4×25 5.6 0.9 1.0 1.6 1.8 26.7
4×35 6.7 0.9 1.0 1.6 1.9 29.5
4×50 8.0 1 1.0 2.0 2.1 34.2
4×70 9.4 1.1 1.2 2.0 2.2 38.8
4×95 11.0 1.1 1.2 2.0 2.3 42.9
4×120 12.4 1.2 1.4 2.5 2.5 48.6
4×150 13.8 1.4 1.4 2.5 2.7 53.2
4×185 15.3 1.6 1.4 2.5 2.8 58.1
4×240 17.5 1.7 1.6 2.5 3.1 64.8
4×300 19.5 1.8 1.6 2.5 3.2 70.4
4×400 22.6 2 1.8 3.15 3.6 81.3

We are China 0.6/1kv Cu/XLPE/PVC/Sta/PVC Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular Armoured Cable Products

Low Voltage Copper/Aluminum Conductor XLPE/PVC Insulated Sta/Swa Armoured Electric Power Cable 0.6/1kv

Low Volatge PVC Insulated Cable

Copper XLPE PVC Low Voltage Power Cable 0.6 / 1 Kv

LV Underground 18/36kv Single Core Copper, 300mm2 DIN VDE 0276-620

Flexible Cable Silicone Rubber Insulated Heat Fire Resisting Cable

Copper Conductor PVC Insulted Steel Tape Armoured PVC Sheathed Electrical Cable VV22

Popular Cu/XLPE/PVC/Sta/PVC Cable Products

  • No related articles
  • Popular luxingcable Products

    Good Price Low Voltage ABC Aluminum Conductor XLPE Insulated Family Cable

    Manufactures Direct Supply Low Voltage Armoured Power Cable with PVC Insulation

    1 Core Flexible Cable H07V-K

    2018 Trending Products 0.6/1kv Underground Cable Wire Electrical with Low Price

    3X2.5mm Power Cable/Power Cable 3X2.5/3X1.5mm2 Power Cable

    4mm PVC Insulated Copper Wire Cable 25 Sq mm Copper Core PVC Insulated Coated Electrical Wire

    Popular Steel Tape Armoured Cable Products

    33kv Single Core 500sqmm Copper Conductor Armoured Power Cable

    11kv Al XLPE Armoured S/C 240sqmm

    High Quality Steel Tape Armoured Cable/Sta Cable

    0.6/1kv 4 Core PVC/XLPE Insulated Sta Steel Tape Armoured Underground Aluminum Power Cable 50mm2

    600/1000V Aluminum 3 Core 25mm Galvanized Steel Tape Armoured Cable

    Steel Tape Armoured Power Cable (STA Cable)

    Tags: , , ,

    FAST AND RELIABLE SERVICE FOR YOUR PROJECT

    Contact our trained experts today to find your perfect power solution.

    ASK A QUESTION