IEC Standard Low Voltage Steel Tape Armoured Cable
IEC Standard Low Voltage Steel Tape Armoured Cable image
Get Latest Price Request a quote
Quick Details
Product Details
IEC standard low voltage Steel tape armoured cable
1.Applications
These cables are used for electricity supply in low voltage installation system, They are suitable for installation in indoors and outdoors,
in cable ducts, under ground, in power and switching stations, local energy distributions, industrial plants,
where there is no risk of mechanical damage.
2.Construction
1)Conductors
The conductors shall be either of Class 1 or Class 2 of plain or metal-coated annealed copper or of plain aluminium or aluminium alloy,
or of Class 5 of plain or metal-coated copper in accordance with IEC 60228.
2)Insulation
XLPE material and thickness shall be as per IEC 60502 or BS 5467 rated for 90C continuous operation.
3)Colour Code
Colour Code (1)
1 Core | Red or Black |
2 Cores | Red, Black |
3 Cores | Red, Yellow, Blue |
4 Cores | Red, Yellow, Blue, Black |
5 Cores | Red, Yellow, Blue, Black, Green |
Above 5 Cores | Black Cores with White numerals |
Colour Code (2)
1 Core | Brown or Blue |
2 Cores | Brown, Blue |
3 Cores | Brown, Black, Grey |
4 Cores | Blue, Brown, Black, Grey |
5 Cores | Green/Yellow, Blue, Brown, Black, Grey |
Above 5 Cores | Black Cores with White numerals |
Other colours can be manufactured upon request.
4)Assembly / Inner Covering
The inner coverings may be extruded or lapped. For cables with circular cores, except cables with more than five cores,
a lapped inner covering shall be permitted only if the interstices between the cores are substantially filled.
A suitable binder is permitted before application of an extruded inner covering.
The material is compatible with the insulating material,
The materials used for inner coverings and fillers shall be suitable for the operating temperature of the cable and compatible with
the insulating material.For halogen free cables, the inner covering and fillers shall also be halogen free compound.
5)Armour
Aluminum/galvanized steel/steel wires applied helically over the Inner Covering as per IEC 60502-1,
or double aluminum/steel tapes and copper/tinned copper wire can also be manufactured upon request.
6)Outer Sheath
Outer sheath shall be of extruded PVC Type ST1/ST2 as per IEC 60502-1, Polyethylene type ST3/ST7,
Halogen free compound ST8, Polychloroprene, chlorosulfonated polyethylene or similar polymers, type SE1 are also available on request.
7)Fire Performance of Cable Sheaths
Cables can be supplied with special flame retardant PVC outer sheath to comply with the flame test requirements of IEC 60332-3-22,
IEC 60332-3-23 and IEC 60332-3-24, Halogen Free material comply to IEC60754-1/2 and IEC 60684-2.
3.Cable Parameters
1)Single core low voltage cables (unarmoured)
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation Thickness | Nominal Sheath Thickness | Overall Diameter (Approx.) |
mm^2 | mm | mm | mm | mm |
1×1.5 | 1.4 | 0.7 | 1.4 | 5.6 |
1×2.5 | 1.8 | 0.7 | 1.4 | 6.0 |
1×4 | 2.3 | 0.7 | 1.4 | 6.5 |
1×6 | 2.8 | 0.7 | 1.4 | 7.0 |
1×10 | 3.6 | 0.7 | 1.4 | 7.8 |
1×16 | 4.5 | 0.7 | 1.4 | 8.7 |
1×25 | 5.6 | 0.9 | 1.4 | 10.2 |
1×35 | 6.7 | 0.9 | 1.4 | 11.3 |
1×50 | 8.0 | 1 | 1.4 | 12.8 |
1×70 | 9.4 | 1.1 | 1.4 | 14.4 |
1×95 | 11.0 | 1.1 | 1.5 | 16.1 |
1×120 | 12.4 | 1.2 | 1.5 | 17.8 |
1×150 | 13.8 | 1.4 | 1.6 | 19.8 |
1×185 | 15.3 | 1.6 | 1.6 | 21.8 |
1×240 | 17.5 | 1.7 | 1.7 | 24.4 |
1×300 | 19.5 | 1.8 | 1.8 | 26.7 |
1×400 | 22.6 | 2 | 1.9 | 30.5 |
1×500 | 25.2 | 2.2 | 2.0 | 33.7 |
1×630 | 28.3 | 2.4 | 2.2 | 37.4 |
1×800 | 31.9 | 2.6 | 2.3 | 41.7 |
1×1000 | 35.7 | 2.8 | 2.4 | 46.2 |
2)Two cores low voltage cables (unarmoured)
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation Thickness | Nominal Sheath Thickness | Overall Diameter (Approx.) |
mm^2 | mm | mm | mm | mm |
2×1.5 | 1.4 | 0.7 | 1.8 | 9.2 |
2×2.5 | 1.8 | 0.7 | 1.8 | 10.0 |
2×4 | 2.3 | 0.7 | 1.8 | 11.0 |
2×6 | 2.8 | 0.7 | 1.8 | 12.0 |
2×10 | 3.6 | 0.7 | 1.8 | 13.6 |
2×16 | 4.5 | 0.7 | 1.8 | 15.4 |
2×25 | 5.6 | 0.9 | 1.8 | 18.4 |
2×35 | 6.7 | 0.9 | 1.8 | 20.6 |
2×50 | 8.0 | 1 | 1.8 | 23.6 |
2×70 | 9.4 | 1.1 | 1.8 | 26.8 |
2×95 | 11.0 | 1.1 | 1.9 | 30.2 |
2×120 | 12.4 | 1.2 | 2.0 | 33.7 |
2×150 | 13.8 | 1.4 | 2.2 | 37.5 |
2×185 | 15.3 | 1.6 | 2.3 | 41.6 |
2×240 | 17.5 | 1.7 | 2.5 | 46.7 |
2×300 | 19.5 | 1.8 | 2.6 | 51.4 |
2×400 | 22.6 | 2 | 2.9 | 58.9 |
3)Three cores low voltage cables (unarmoured)
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation Thickness | Nominal Sheath Thickness | Overall Diameter (Approx.) |
mm^2 | mm | mm | mm | mm |
3×1.5 | 1.4 | 0.7 | 1.8 | 9.6 |
3×2.5 | 1.8 | 0.7 | 1.8 | 10.5 |
3×4 | 2.3 | 0.7 | 1.8 | 11.6 |
3×6 | 2.8 | 0.7 | 1.8 | 12.6 |
3×10 | 3.6 | 0.7 | 1.8 | 14.4 |
3×16 | 4.5 | 0.7 | 1.8 | 16.3 |
3×25 | 5.6 | 0.9 | 1.8 | 19.5 |
3×35 | 6.7 | 0.9 | 1.8 | 21.9 |
3×50 | 8.0 | 1 | 1.8 | 25.1 |
3×70 | 9.4 | 1.1 | 1.9 | 28.7 |
3×95 | 11.0 | 1.1 | 2.0 | 32.4 |
3×120 | 12.4 | 1.2 | 2.1 | 36.1 |
3×150 | 13.8 | 1.4 | 2.3 | 40.3 |
3×185 | 15.3 | 1.6 | 2.4 | 44.6 |
3×240 | 17.5 | 1.7 | 2.6 | 50.2 |
3×300 | 19.5 | 1.8 | 2.7 | 55.2 |
3×400 | 22.6 | 2 | 3.0 | 63.3 |
4)Three cores+1 low voltage cables (unarmoured)
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation Thickness | Nominal Sheath Thickness | Overall Diameter (Approx.) | ||
mm^2 | (3)mm | (1)mm | (3)mm | (1)mm | mm | mm |
3x 16/10 | 4.5 | 3.6 | 0.7 | 0.7 | 1.8 | 17.5 |
3x 25/16 | 5.6 | 4.5 | 0.9 | 0.7 | 1.8 | 21.2 |
3x 35/16 | 6.7 | 4.5 | 0.9 | 0.7 | 1.8 | 23.8 |
3x 50/25 | 8 | 5.6 | 1 | 0.9 | 1.8 | 27.5 |
3x 70/35 | 9.4 | 6.7 | 1.1 | 0.9 | 2.0 | 31.7 |
3x 95/50 | 11 | 8 | 1.1 | 1 | 2.1 | 35.8 |
3×120/70 | 12.4 | 9.4 | 1.2 | 1.1 | 2.3 | 39.9 |
3×150/70 | 13.8 | 9.4 | 1.4 | 1.1 | 2.4 | 44.6 |
3×185/95 | 15.3 | 11 | 1.6 | 1.1 | 2.6 | 49.5 |
3×240/120 | 17.5 | 12.4 | 1.7 | 1.2 | 2.8 | 55.7 |
3×300/150 | 19.5 | 13.8 | 1.8 | 1.4 | 3.0 | 61.4 |
3×400/185 | 22.6 | 15.3 | 2 | 1.6 | 3.2 | 70.4 |
5)Four cores low voltage cables (unarmoured)
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation Thickness | Nominal Sheath Thickness | Overall Diameter (Approx.) |
mm^2 | mm | mm | mm | mm |
4×1.5 | 1.4 | 0.7 | 1.8 | 10.4 |
4×2.5 | 1.8 | 0.7 | 1.8 | 11.3 |
4×4 | 2.3 | 0.7 | 1.8 | 12.5 |
4×6 | 2.8 | 0.7 | 1.8 | 13.7 |
4×10 | 3.6 | 0.7 | 1.8 | 15.7 |
4×16 | 4.5 | 0.7 | 1.8 | 17.8 |
4×25 | 5.6 | 0.9 | 1.8 | 21.5 |
4×35 | 6.7 | 0.9 | 1.8 | 24.1 |
4×50 | 8.0 | 1 | 1.8 | 27.8 |
4×70 | 9.4 | 1.1 | 2.0 | 32.0 |
4×95 | 11.0 | 1.1 | 2.1 | 36.1 |
4×120 | 12.4 | 1.2 | 2.3 | 40.2 |
4×150 | 13.8 | 1.4 | 2.4 | 44.9 |
4×185 | 15.3 | 1.6 | 2.6 | 49.8 |
4×240 | 17.5 | 1.7 | 2.8 | 56.0 |
4×300 | 19.5 | 1.8 | 3.0 | 61.7 |
4×400 | 22.6 | 2 | 3.2 | 70.7 |
6)Multi-cores low voltage cables(unarmoured)
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation Thickness | Nominal Sheath Thickness | Overall Diameter (Approx.) |
mm^2 | mm | mm | mm | mm |
5×1.5 | 1.4 | 0.7 | 1.8 | 11.2 |
7×1.5 | 1.4 | 0.7 | 1.8 | 12.0 |
10×1.5 | 1.4 | 0.7 | 1.8 | 14.8 |
12×1.5 | 1.4 | 0.7 | 1.8 | 15.2 |
14×1.5 | 1.4 | 0.7 | 1.8 | 16.0 |
19×1.5 | 1.4 | 0.7 | 1.8 | 17.6 |
21×1.5 | 1.4 | 0.7 | 1.8 | 18.4 |
24×1.5 | 1.4 | 0.7 | 1.8 | 20.4 |
30×1.5 | 1.4 | 0.7 | 1.8 | 21.6 |
40×1.5 | 1.4 | 0.7 | 1.8 | 26.0 |
48×1.5 | 1.4 | 0.7 | 1.8 | 26.4 |
61×1.5 | 1.4 | 0.7 | 1.9 | 29.0 |
5×2.5 | 1.8 | 0.7 | 1.8 | 12.2 |
7×2.5 | 1.8 | 0.7 | 1.8 | 13.2 |
10×2.5 | 1.8 | 0.7 | 1.8 | 16.4 |
12×2.5 | 1.8 | 0.7 | 1.8 | 16.9 |
14×2.5 | 1.8 | 0.7 | 1.8 | 17.7 |
19×2.5 | 1.8 | 0.7 | 1.8 | 19.6 |
21×2.5 | 1.8 | 0.7 | 1.8 | 20.6 |
24×2.5 | 1.8 | 0.7 | 1.8 | 22.8 |
30×2.5 | 1.8 | 0.7 | 1.8 | 24.1 |
40×2.5 | 1.8 | 0.7 | 1.9 | 29.4 |
48×2.5 | 1.8 | 0.7 | 1.9 | 29.9 |
61×2.5 | 1.8 | 0.7 | 2.0 | 32.8 |
7)Single core low voltage cables ( aluminum wire armoured)
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation thickness | Nominal Inner Covering thickness | Nominal Alum Wire dia. | Nominal Sheath thickness | Overall Diameter (Approx.) |
mm^2 | mm | mm | mm | mm | mm | mm |
1×4 | 2.3 | 0.7 | 1.0 | 0.8 | 1.8 | 10.9 |
1×6 | 2.8 | 0.7 | 1.0 | 0.8 | 1.8 | 11.4 |
1×10 | 3.6 | 0.7 | 1.0 | 0.8 | 1.8 | 12.2 |
1×16 | 4.5 | 0.7 | 1.0 | 0.8 | 1.8 | 13.1 |
1×25 | 5.6 | 0.9 | 1.0 | 0.8 | 1.8 | 14.6 |
1×35 | 6.7 | 0.9 | 1.0 | 1.25 | 1.8 | 16.6 |
1×50 | 8.0 | 1 | 1.0 | 1.25 | 1.8 | 18.1 |
1×70 | 9.4 | 1.1 | 1.0 | 1.25 | 1.8 | 19.7 |
1×95 | 11.0 | 1.1 | 1.0 | 1.6 | 1.8 | 22.0 |
1×120 | 12.4 | 1.2 | 1.0 | 1.6 | 1.8 | 23.6 |
1×150 | 13.8 | 1.4 | 1.0 | 1.6 | 1.8 | 25.4 |
1×185 | 15.3 | 1.6 | 1.0 | 1.6 | 1.8 | 27.4 |
1×240 | 17.5 | 1.7 | 1.0 | 1.6 | 1.9 | 29.9 |
1×300 | 19.5 | 1.8 | 1.0 | 2.0 | 2.0 | 33.1 |
1×400 | 22.6 | 2 | 1.2 | 2.0 | 2.2 | 37.3 |
1×500 | 25.2 | 2.2 | 1.2 | 2.0 | 2.3 | 40. |
8)Two cores low voltage cables (Galvanized steel wire armoured)
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation thickness | Nominal Inner Covering thickness | Nominal Steel Wire dia. | Nominal Sheath thickness | Overall Diameter (Approx.) |
mm^2 | mm | mm | mm | mm | mm | mm |
2×1.5 | 1.4 | 0.7 | 1.0 | 0.8 | 1.8 | 12.8 |
2×2.5 | 1.8 | 0.7 | 1.0 | 0.8 | 1.8 | 13.6 |
2×4 | 2.3 | 0.7 | 1.0 | 0.8 | 1.8 | 14.6 |
2×6 | 2.8 | 0.7 | 1.0 | 1.25 | 1.8 | 16.5 |
2×10 | 3.6 | 0.7 | 1.0 | 1.25 | 1.8 | 18.1 |
2×16 | 4.5 | 0.7 | 1.0 | 1.25 | 1.8 | 19.9 |
2×25 | 5.6 | 0.9 | 1.0 | 1.6 | 1.8 | 23.6 |
2×35 | 6.7 | 0.9 | 1.0 | 1.6 | 1.8 | 25.8 |
2×50 | 8.0 | 1 | 1.0 | 1.6 | 1.9 | 29.0 |
2×70 | 9.4 | 1.1 | 1.0 | 2.0 | 2.0 | 33.2 |
2×95 | 11.0 | 1.1 | 1.2 | 2.0 | 2.1 | 37.1 |
2×120 | 12.4 | 1.2 | 1.2 | 2.0 | 2.3 | 40.5 |
2×150 | 13.8 | 1.4 | 1.2 | 2.5 | 2.4 | 45.4 |
2×185 | 15.3 | 1.6 | 1.4 | 2.5 | 2.6 | 49.9 |
2×240 | 17.5 | 1.7 | 1.4 | 2.5 | 2.7 | 55.1 |
2×300 | 19.5 | 1.8 | 1.6 | 2.5 | 2.9 | 60.2 |
2×400 | 22.6 | 2 | 1.6 | 2.5 | 3.1 | 67.7 |
9)Three cores low voltage cables (Galvanized steel wire armoured)
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation thickness | Nominal Inner Covering thickness | Nominal Steel Wire dia. | Nominal Sheath thickness | Overall Diameter (Approx.) |
mm^2 | mm | mm | mm | mm | mm | mm |
3×1.5 | 1.4 | 0.7 | 1.0 | 0.8 | 1.8 | 13.2 |
3×2.5 | 1.8 | 0.7 | 1.0 | 0.8 | 1.8 | 14.1 |
3×4 | 2.3 | 0.7 | 1.0 | 0.8 | 1.8 | 15.2 |
3×6 | 2.8 | 0.7 | 1.0 | 1.25 | 1.8 | 17.1 |
3×10 | 3.6 | 0.7 | 1.0 | 1.25 | 1.8 | 18.9 |
3×16 | 4.5 | 0.7 | 1.0 | 1.25 | 1.8 | 20.8 |
3×25 | 5.6 | 0.9 | 1.0 | 1.6 | 1.8 | 24.7 |
3×35 | 6.7 | 0.9 | 1.0 | 1.6 | 1.8 | 27.2 |
3×50 | 8.0 | 1 | 1.0 | 1.6 | 1.9 | 30.6 |
3×70 | 9.4 | 1.1 | 1.0 | 2.0 | 2.1 | 35.2 |
3×95 | 11.0 | 1.1 | 1.2 | 2.0 | 2.2 | 39.3 |
3×120 | 12.4 | 1.2 | 1.2 | 2.0 | 2.3 | 43.0 |
3×150 | 13.8 | 1.4 | 1.4 | 2.5 | 2.5 | 48.6 |
3×185 | 15.3 | 1.6 | 1.4 | 2.5 | 2.7 | 53.0 |
3×240 | 17.5 | 1.7 | 1.4 | 2.5 | 2.8 | 58.5 |
3×300 | 19.5 | 1.8 | 1.6 | 2.5 | 3.0 | 64.0 |
3×400 | 22.6 | 2 | 1.6 | 3.15 | 3.3 | 73.5 |
10)Three cores+1 low voltage cables (Galvanized steel wire armoured)
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation thickness | Nominal Inner Covering thickness | Nominal Steel Wire dia. | Nominal Sheath thickness | Overall Diameter (Approx.) | ||
mm^2 | (3) mm | (1) mm | (3) mm | (1) mm | mm | mm | mm | mm |
3x 16/10 | 4.5 | 3.6 | 0.7 | 0.7 | 1 | 1.6 | 1.8 | 22.7 |
3x 25/16 | 5.6 | 4.5 | 0.9 | 0.7 | 1 | 1.6 | 1.8 | 26.5 |
3x 35/16 | 6.7 | 4.5 | 0.9 | 0.7 | 1 | 1.6 | 1.9 | 29 |
3x 50/25 | 8.0 | 5.6 | 1 | 0.9 | 1 | 1.6 | 2.1 | 33 |
3x 70/35 | 9.4 | 6.7 | 1.1 | 0.9 | 1.2 | 2 | 2.2 | 38 |
3x 95/50 | 11.0 | 8.0 | 1.1 | 1 | 1.2 | 2 | 2.3 | 42.4 |
3×120/70 | 12.4 | 9.4 | 1.2 | 1.1 | 1.2 | 2 | 2.5 | 48.0 |
3×150/70 | 13.8 | 9.4 | 1.4 | 1.1 | 1.4 | 2.5 | 2.7 | 52 |
3×185/95 | 15.3 | 11.0 | 1.6 | 1.1 | 1.4 | 2.5 | 2.8 | 57.2 |
3×240/120 | 17.5 | 12.4 | 1.7 | 1.2 | 1.6 | 2.5 | 3.1 | 64 |
3×300/150 | 19.5 | 13.8 | 1.8 | 1.4 | 1.6 | 2.5 | 3.2 | 69.8 |
3×400/185 | 22.6 | 15.3 | 2 | 1.6 | 1.6 | 3.15 | 3.6 | 78.6 |
11)Four cores low voltage cables (Galvanized steel wire armoured)
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation thickness | Nominal Inner Covering thickness | Nominal Steel Wire dia. | Nominal Sheath thickness | Overall Diameter (Approx.) |
mm^2 | mm | mm | mm | mm | mm | mm |
4×1.5 | 1.4 | 0.7 | 1.0 | 0.8 | 1.8 | 14.0 |
4×2.5 | 1.8 | 0.7 | 1.0 | 0.8 | 1.8 | 14.9 |
4×4 | 2.3 | 0.7 | 1.0 | 1.25 | 1.8 | 17.0 |
4×6 | 2.8 | 0.7 | 1.0 | 1.25 | 1.8 | 18.2 |
4×10 | 3.6 | 0.7 | 1.0 | 1.25 | 1.8 | 20.2 |
4×16 | 4.5 | 0.7 | 1.0 | 1.6 | 1.8 | 23.0 |
4×25 | 5.6 | 0.9 | 1.0 | 1.6 | 1.8 | 26.7 |
4×35 | 6.7 | 0.9 | 1.0 | 1.6 | 1.9 | 29.5 |
4×50 | 8.0 | 1 | 1.0 | 2.0 | 2.1 | 34.2 |
4×70 | 9.4 | 1.1 | 1.2 | 2.0 | 2.2 | 38.8 |
4×95 | 11.0 | 1.1 | 1.2 | 2.0 | 2.3 | 42.9 |
4×120 | 12.4 | 1.2 | 1.4 | 2.5 | 2.5 | 48.6 |
4×150 | 13.8 | 1.4 | 1.4 | 2.5 | 2.7 | 53.2 |
4×185 | 15.3 | 1.6 | 1.4 | 2.5 | 2.8 | 58.1 |
4×240 | 17.5 | 1.7 | 1.6 | 2.5 | 3.1 | 64.8 |
4×300 | 19.5 | 1.8 | 1.6 | 2.5 | 3.2 | 70.4 |
4×400 | 22.6 | 2 | 1.8 | 3.15 | 3.6 | 81.3 |
We are China IEC Standard Low Voltage Steel Tape Armoured Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Armoured Cable Products
11kv 22kv 33kv High Quality XLPE Insulated Cable Wire Electrical Copper
4 Core 95 Sqmm XLPE Insulated U1000 Rvfv Cable Sta Armoured Cable
Aluminum Conductor PVC Insulated PVC Sheathed Electrical Cable
Voltage 6.35/11 (12) Kv Single Core Armoured Copper Conductors Cable
1kv XLPE Cable, Armoured Cable Sta Cable with Ce Certificate.
Popular Electric Cables Products
Twin Twisted Cable PVC Insulated Rvs 2*1.5mm2 Electrical Wire Roll
CCC (IEC) Standard Copper Core PVC Insulation Flexible Twisted Cable Rvs
Low Voltage XLPE/PE Insulated Duplex Aluminium Cable
Low Voltage with Insulated Aerial Bundled Electric Cables
PVC Electrical Electric Power Stringing Zr-BV/BVV//Bvr/RV/Rvv Copper Cable Wire
12/20kv XLPE Insulated Power Cables 3 Cores Mv Cable Medium Voltage Cable Electric Cables
Popular luxingcable Products
Aluminum Alloy Conductor Cables Power Cable Yjlhv62
Aluminium Conductor Steel Reinforced ACSR Cable
Vc4V-K Cable Flexible Copper Conductor Copper Wire Screen Cable
Improved Properties Bare AAAC Aluminum Electrical Wire Power Cable Conductor
Popular Steel Tape Armoured Cable Products
Mv Cable Cu/Al XLPE Insulated Shielded Underground Power Cable
11kv XLPE Armoured Single Core 500mm2 IEC60502-2
0.6/1kv 4 Core PVC/XLPE Insulated Sta Steel Tape Armoured Underground Aluminum Power Cable 50mm2
33kv Single Core S/C 630mm2 Cable IEC60502-2
15kv Yjv32 Copper Conductor XLPE Insulated Power Cable
Mv Cable Cu/Al XLPE Insulated Shielded Underground Power Cable
Tags: Armoured Cable, Electric Cables, luxingcable, Steel Tape Armoured Cable