0.6/1kv Overhead XLPE Insulated ABC Cable for Power Transmission
0.6/1kv Overhead XLPE Insulated ABC Cable for Power Transmission image
Get Latest Price Request a quote
Quick Details
Product Details
1.Application
(1)Duplex Service Drop
Application:To supply 120 volt aerial service for temporary service at construction sites,outdoor or street lighting . For service at 600 volts or lower at a conductor temperature of 75°C maximum.
(2)Triplex Service Drop
Application: To supply power from the utility’s lines to the consumer’s weatherhead. For service at 600 volt or less (phase to phase) at a conductor temperature of 75°C maximum for polyethylene insulation 90°C maximum for crosslinked insulation.
(3)Quadruplex Service Drop.
Used to supply 3 phase power, usually from a polemounted transformer, to the user’s service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperatures not to exceed 75°C for polyethylene insulation 90°C maximum for crosslinked polyethylene(XLPE) insulated conductors.
2.Construction
Conductors are concentrically stranded ,compressed 1350-H19aluminum,insulated with either polyethylene(PE) or crosslinked polyethylene(XLPE).The neutral messengers are concentrically stranded AAC, ACSR, or 6201 aluminum alloy.
3.Standard:
ASTM B-230,B-231,B-232 and B-399
IEC S-76-474
4.Specification
Code name | Phase conductor | Bare neutral messenger | Weight per 1000 ft(lbs) |
Rating(Amps) | ||||||
Size AWG |
Strand |
Insulation thickness (mls) |
Size AWG |
Strand |
Breaking strength (lbs) |
XLP |
POLY |
XLP |
POLY |
|
AAC NEUTRAL-MESSNGER | ||||||||||
Clydesdale | 4 | Solid | 45 | 4 | 7 | 881 | 208 | 201.8 | 100 | 80 |
Pinto | 4 | 7/w | 45 | 4 | 7 | 881 | 223 | 207.9 | 100 | 80 |
Mustang | 2 | 7/w | 45 | 2 | 7 | 1,350 | 333 | 312.6 | 135 | 105 |
Criollo | 1/0 | 19/w | 60 | 1/0 | 7 | 1,990 | 529 | 504.5 | 180 | 140 |
Percheron | 2/0 | 19/w | 60 | 2/0 | 7 | 2,510 | 649 | 620.5 | 205 | 160 |
Hanoverian | 3/0 | 19/w | 60 | 3/0 | 19 | 3,310 | 799 | 765.6 | 235 | 185 |
Oldenburg | 4/0 | 19/w | 60 | 4/0 | 19 | 4,020 | 986 | 946.7 | 275 | 210 |
Lippizaner | 336.4 | 19/w | 80 | 336.4 | 19 | 6,146 | 1,546 | 1,519.2 | 370 | 280 |
ACSR NEUTRAL-MESSNGER | ||||||||||
Morochuca | 6 | Solid | 45 | 6 | 6/1 | 1,190 | 152 | 147.4 | 75 | 60 |
Chola | 6 | 7/w | 45 | 6 | 6/1 | 1,190 | 162 | 151.7 | 75 | 60 |
Morgan | 4 | Solid | 45 | 4 | 6/1 | 1,860 | 226 | 220 | 100 | 80 |
Hackney | 4 | 7/w | 45 | 4 | 6/1 | 1,860 | 241 | 226.1 | 100 | 80 |
Palomino | 2 | 7/w | 45 | 2 | 6/1 | 2,850 | 362 | 342.6 | 135 | 105 |
Costena | 1/0 | 19/w | 60 | 1/0 | 6/1 | 4,380 | 575 | 550.6 | 180 | 140 |
Grullo | 2/0 | 19/w | 60 | 2/0 | 6/1 | 5,310 | 707 | 678.7 | 205 | 160 |
Suffolk | 3/0 | 19/w | 60 | 3/0 | 6/1 | 6,620 | 872 | 838.9 | 235 | 185 |
Appaloosa | 4/0 | 19/w | 60 | 4/0 | 6/1 | 8,350 | 1079 | 1039.2 | 275 | 210 |
Bronco | 336.4 | 19/w | 80 | 336.4 | 18/1 | 8,580 | 1613 | 1568.2 | 370 | 280 |
Gelding | 336.4 | 19/w | 80 | 4/0 | 6/1 | 8,350 | 1548 | 1494.3 | 370 | 280 |
6201 ALLOY NEUTRAL-MESSENGER | ||||||||||
Bay | 6 | Solid | 45 | 6 | 7 | 1,110 | 145 | 140.0 | 75 | 60 |
French Coach | 6 | 7/w | 45 | 6 | 7 | 1,110 | 155 | 144.3 | 75 | 60 |
German Coach | 4 | Solid | 45 | 4 | 7 | 1,760 | 214 | 208.3 | 100 | 80 |
Arabian | 4 | 7/w | 45 | 4 | 7 | 1,760 | 229 | 214.4 | 100 | 80 |
Belgian | 2 | 7/w | 45 | 2 | 7 | 2,800 | 344 | 323.1 | 135 | 105 |
Shetland | 1/0 | 19/w | 60 | 1/0 | 7 | 4,460 | 546 | 521.1 | 180 | 140 |
Thoroughbred | 2/0 | 19/w | 60 | 2/0 | 7 | 5,390 | 670 | 641.5 | 205 | 160 |
Trotter | 3/0 | 19/w | 60 | 3/0 | 7 | 6,790 | 825 | 791.8 | 235 | 185 |
Walking | 4/0 | 19/w | 60 | 4/0 | 7 | 8,560 | 1019 | 979.7 | 275 | 210 |
5.About US
People’s Cable Group Co., Ltd. was founded in 2007, located in Zhengzhou Gongyi economic development zone. Our company has 2 factories (Zhitian factory and Zhulin factory), occupies total area of more than 300,000 square meters, with building area 230,000 square meters. The real capital assets more than USD 10 million , with total 500 staff members, 65 of which are professional and technical experts.
6.Certificate
As first rank of the cable supplier in China, we have obtained CCC, ISO9001, ISO14001, OHSAS certificates, passed the SGS and BV test, and our brand "RMJT" be given China famous brand.
7.Customer Visit
We have a professional sales team with each of them has engaged in this job for 3-10 years, so that we can provide the comprehensive and professional technology for you. With the perfect quality and after sales service, till now we have exported to more than 80 countries, welcome to visit us and establish win-win relationship!
8. FAQ
(1)When can I get the price?
We usually quote within 6 hours after we get your inquiry. If you are very urgent to get the price, please call us or tell us in your e-mail so that we will regard your inquiry priority.
(2)How can I get a sample to check your quality?
After price confirmation, you can require for samples to check our quality. Sample is free, but the freight charge should be paid.
(3)How long can I expect to get the sample?
After you pay the freight charge and send us confirmed files, the samples will be ready for delivery in 3-7 days. The samples will be sent to you via express and arrive in 3-5 days. You can use your own express account or prepay us if you do not have an account.
(4)What about the lead time for mass production?
Honestly, it depends on the order quantity and the season you place the order. The best record we keep is delivering 10 kilometers cable within a week. Generally speaking, we suggest that you start inquiry two months before the date you would like to get the products at your country?
9. Contact us
We are China 0.6/1kv Overhead XLPE Insulated ABC Cable for Power Transmission manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Aerial Bundle Cable Products
0.6/1kv Quadruplex ABC Aerial Bundle Cable for Overhead Transmission Line
Overhead Aerial Bundle (AL/XLPE) Insulated ABC Cable-AS/NZS 3560.1 Standard
Al/XLPE 0.6/1kv Overhead ABC Cable
Aluminum Conductors Steel Reinforced Aluminum Covered Line Wire ABC
Aerial Bundle Cable ABC Cable Size Type Overhead
Popular Aerial Bundled Cable Products
Low Voltage Aerial Bundled Cable for Transmission Line ABC Cable
Aluminium Conductor ABC Electric Cable
Free Samples, AS/NZS 3599.2, Hv ABC Cable, Al/XLPE+AAAC Aerial Bundled Cable
0.6/1 Kv LV Aerial Bundled Cable 3 Core Phase 50mm2 AAC 50mm2 Bare AAAC Messenger
4 Cores 50mm2 70mm2 95mm2 Aerial Bundled ABC Cable
Popular renmincable Products
Aluminium Insulated Overhead Triplex Service Drop ABC Cable Manufacturer
Yjv Insulated Underground Electrical Wire Power Cable
0.6/1kv 4X150mm2 Copper Conductor XLPE Insulated Electrical Power Cable
35kv XLPE Insulated Waterproof Power Cable
Yjlv22 XLPE Insulated Steel Tap Armored Power Cable Al Power Cable
ASTM Standard AAC Conductor XLPE Insulated Overhead Aerial Bundle ABC Cable
Popular XLPE Insulated Cable Products
XLPE Insulated Aerial Bundle NFC 33-209 ABC Cabl
3X35/16mm2 N2xseyfgby 6/10 (12) Kv High Voltage Copper XLPE Insulated Cable
33kv 3 Core Power Cable with Aluminum Conductor
XLPE /PVC (Cross-linked polyethylene) Insulated/ Insulation Electric Power Cable
Copper PVC Insulation PVC Jacket Shielded Electrical Wire Cable
XLPE Insulated PVC Sheathed Steel Tape Armoured Copper Electrical Cables
Tags: Aerial Bundle Cable, Aerial Bundled Cable, renmincable, XLPE Insulated Cable