0.6/1kv Yjv22 XLPE Armoured Power Cable

China 
                        0.6/1kv Yjv22 XLPE Armoured Power Cable
                      manufacture and supplier

0.6/1kv Yjv22 XLPE Armoured Power Cable image

Get Latest Price Request a quote

Quick Details

0.6/1kv Yjv22 XLPE Armoured Power Cable

YJV22 Xlpe Power Cable

Luxing Cables

Low Voltage Cables

ISO, CCC, CE, RoHS

Bare Copper Wire

Round Wire

PVC

XLPE

DC & AC

Low and Medium Voltage Cable

Construction, Underground, Industrial, Power Station

1.5-800mm2

Steel Tape Armoured,Steel Wire Armoured

IEC, BS, VDE, GB/T

CHANG QING TENG

Wooden Drum, Steel Wooden Drum, Steel Iron Drum

0.6/1kv

Dezhou, Shandong

8544492100

Product Details

0.6/1KV YJV22 Xlpe Armoured Power Cable

1.Applications

These cables are used for electricity supply in low voltage installation system, They are suitable for installation in indoors and outdoors,
in cable ducts, under ground, in power and switching stations, local energy distributions, industrial plants,
where there is no risk of mechanical damage.

2.Construction

1)Conductors

The conductors shall be either of Class 1 or Class 2 of plain or metal-coated annealed copper or of plain aluminium or aluminium alloy, 

or of Class 5 of plain or metal-coated copper in accordance with IEC 60228.

2)Insulation

XLPE material and thickness shall be as per IEC 60502 or BS 5467 rated for 90C continuous operation.

3)Colour Code

Colour Code (1)

1 Core Red or Black
2 Cores Red, Black
3 Cores Red, Yellow, Blue
4 Cores Red, Yellow, Blue, Black
5 Cores Red, Yellow, Blue, Black, Green
Above 5 Cores Black Cores with White numerals

Colour Code (2)

1 Core Brown or Blue
2 Cores Brown, Blue
3 Cores Brown, Black, Grey
4 Cores Blue, Brown, Black, Grey
5 Cores Green/Yellow, Blue, Brown, Black, Grey
Above 5 Cores Black Cores with White numerals

Other colours can be manufactured upon request.

4)Assembly / Inner Covering

The inner coverings may be extruded or lapped. For cables with circular cores, except cables with more than five cores,
a lapped inner covering shall be permitted only if the interstices between the cores are substantially filled.
A suitable binder is permitted before application of an extruded inner covering.
The material is compatible with the insulating material,
The materials used for inner coverings and fillers shall be suitable for the operating temperature of the cable and compatible with
the insulating material.For halogen free cables, the inner covering and fillers shall also be halogen free compound.

5)Armour

Aluminum/galvanized steel/steel wires applied helically over the Inner Covering as per IEC 60502-1,
or double aluminum/steel tapes and copper/tinned copper wire can also be manufactured upon request.

6)Outer Sheath

Outer sheath shall be of extruded PVC Type ST1/ST2 as per IEC 60502-1, Polyethylene type ST3/ST7,
Halogen free compound ST8, Polychloroprene, chlorosulfonated polyethylene or similar polymers, type SE1 are also available on request.

7)Fire Performance of Cable Sheaths

Cables can be supplied with special flame retardant PVC outer sheath to comply with the flame test requirements of IEC 60332-3-22,
IEC 60332-3-23 and IEC 60332-3-24, Halogen Free material comply to IEC60754-1/2 and IEC 60684-2.

3.Cable Parameters

1)Single core low voltage cables (unarmoured)

Nominal Cross Section Diameter of Conductor (Approx.) Nominal Insulation Thickness Nominal Sheath Thickness Overall Diameter (Approx.)
mm^2 mm mm mm mm
1×1.5 1.4 0.7 1.4 5.6
1×2.5 1.8 0.7 1.4 6.0
1×4 2.3 0.7 1.4 6.5
1×6 2.8 0.7 1.4 7.0
1×10 3.6 0.7 1.4 7.8
1×16 4.5 0.7 1.4 8.7
1×25 5.6 0.9 1.4 10.2
1×35 6.7 0.9 1.4 11.3
1×50 8.0 1 1.4 12.8
1×70 9.4 1.1 1.4 14.4
1×95 11.0 1.1 1.5 16.1
1×120 12.4 1.2 1.5 17.8
1×150 13.8 1.4 1.6 19.8
1×185 15.3 1.6 1.6 21.8
1×240 17.5 1.7 1.7 24.4
1×300 19.5 1.8 1.8 26.7
1×400 22.6 2 1.9 30.5
1×500 25.2 2.2 2.0 33.7
1×630 28.3 2.4 2.2 37.4
1×800 31.9 2.6 2.3 41.7
1×1000 35.7 2.8 2.4 46.2

2)Two cores low voltage cables (unarmoured)

Nominal Cross Section Diameter of Conductor (Approx.) Nominal Insulation Thickness Nominal Sheath Thickness Overall Diameter (Approx.)
mm^2 mm mm mm mm
2×1.5 1.4 0.7 1.8 9.2
2×2.5 1.8 0.7 1.8 10.0
2×4 2.3 0.7 1.8 11.0
2×6 2.8 0.7 1.8 12.0
2×10 3.6 0.7 1.8 13.6
2×16 4.5 0.7 1.8 15.4
2×25 5.6 0.9 1.8 18.4
2×35 6.7 0.9 1.8 20.6
2×50 8.0 1 1.8 23.6
2×70 9.4 1.1 1.8 26.8
2×95 11.0 1.1 1.9 30.2
2×120 12.4 1.2 2.0 33.7
2×150 13.8 1.4 2.2 37.5
2×185 15.3 1.6 2.3 41.6
2×240 17.5 1.7 2.5 46.7
2×300 19.5 1.8 2.6 51.4
2×400 22.6 2 2.9 58.9

3)Three cores low voltage cables (unarmoured)

Nominal Cross Section Diameter of Conductor (Approx.) Nominal Insulation Thickness Nominal Sheath Thickness Overall Diameter (Approx.)
mm^2 mm mm mm mm
3×1.5 1.4 0.7 1.8 9.6
3×2.5 1.8 0.7 1.8 10.5
3×4 2.3 0.7 1.8 11.6
3×6 2.8 0.7 1.8 12.6
3×10 3.6 0.7 1.8 14.4
3×16 4.5 0.7 1.8 16.3
3×25 5.6 0.9 1.8 19.5
3×35 6.7 0.9 1.8 21.9
3×50 8.0 1 1.8 25.1
3×70 9.4 1.1 1.9 28.7
3×95 11.0 1.1 2.0 32.4
3×120 12.4 1.2 2.1 36.1
3×150 13.8 1.4 2.3 40.3
3×185 15.3 1.6 2.4 44.6
3×240 17.5 1.7 2.6 50.2
3×300 19.5 1.8 2.7 55.2
3×400 22.6 2 3.0 63.3

4)Three cores+1 low voltage cables (unarmoured)

Nominal Cross Section Diameter of Conductor (Approx.) Nominal Insulation Thickness Nominal Sheath Thickness Overall Diameter (Approx.)
mm^2 (3)mm (1)mm (3)mm (1)mm mm mm
3x 16/10 4.5 3.6 0.7 0.7 1.8 17.5
3x 25/16 5.6 4.5 0.9 0.7 1.8 21.2
3x 35/16 6.7 4.5 0.9 0.7 1.8 23.8
3x 50/25 8 5.6 1 0.9 1.8 27.5
3x 70/35 9.4 6.7 1.1 0.9 2.0 31.7
3x 95/50 11 8 1.1 1 2.1 35.8
3×120/70 12.4 9.4 1.2 1.1 2.3 39.9
3×150/70 13.8 9.4 1.4 1.1 2.4 44.6
3×185/95 15.3 11 1.6 1.1 2.6 49.5
3×240/120 17.5 12.4 1.7 1.2 2.8 55.7
3×300/150 19.5 13.8 1.8 1.4 3.0 61.4
3×400/185 22.6 15.3 2 1.6 3.2 70.4

5)Four cores low voltage cables (unarmoured)

Nominal Cross Section Diameter of Conductor (Approx.) Nominal Insulation Thickness Nominal Sheath Thickness Overall Diameter (Approx.)
mm^2 mm mm mm mm
4×1.5 1.4 0.7 1.8 10.4
4×2.5 1.8 0.7 1.8 11.3
4×4 2.3 0.7 1.8 12.5
4×6 2.8 0.7 1.8 13.7
4×10 3.6 0.7 1.8 15.7
4×16 4.5 0.7 1.8 17.8
4×25 5.6 0.9 1.8 21.5
4×35 6.7 0.9 1.8 24.1
4×50 8.0 1 1.8 27.8
4×70 9.4 1.1 2.0 32.0
4×95 11.0 1.1 2.1 36.1
4×120 12.4 1.2 2.3 40.2
4×150 13.8 1.4 2.4 44.9
4×185 15.3 1.6 2.6 49.8
4×240 17.5 1.7 2.8 56.0
4×300 19.5 1.8 3.0 61.7
4×400 22.6 2 3.2 70.7

6)Multi-cores low voltage cables(unarmoured)

Nominal Cross Section Diameter of Conductor (Approx.) Nominal Insulation Thickness Nominal Sheath Thickness Overall Diameter (Approx.)
mm^2 mm mm mm mm
5×1.5 1.4 0.7 1.8 11.2
7×1.5 1.4 0.7 1.8 12.0
10×1.5 1.4 0.7 1.8 14.8
12×1.5 1.4 0.7 1.8 15.2
14×1.5 1.4 0.7 1.8 16.0
19×1.5 1.4 0.7 1.8 17.6
21×1.5 1.4 0.7 1.8 18.4
24×1.5 1.4 0.7 1.8 20.4
30×1.5 1.4 0.7 1.8 21.6
40×1.5 1.4 0.7 1.8 26.0
48×1.5 1.4 0.7 1.8 26.4
61×1.5 1.4 0.7 1.9 29.0
5×2.5 1.8 0.7 1.8 12.2
7×2.5 1.8 0.7 1.8 13.2
10×2.5 1.8 0.7 1.8 16.4
12×2.5 1.8 0.7 1.8 16.9
14×2.5 1.8 0.7 1.8 17.7
19×2.5 1.8 0.7 1.8 19.6
21×2.5 1.8 0.7 1.8 20.6
24×2.5 1.8 0.7 1.8 22.8
30×2.5 1.8 0.7 1.8 24.1
40×2.5 1.8 0.7 1.9 29.4
48×2.5 1.8 0.7 1.9 29.9
61×2.5 1.8 0.7 2.0 32.8

7)Single core low voltage cables ( aluminum wire armoured)

Nominal Cross Section Diameter of Conductor (Approx.) Nominal Insulation thickness Nominal Inner Covering thickness Nominal Alum Wire dia. Nominal Sheath thickness Overall Diameter (Approx.)
mm^2 mm mm mm mm mm mm
1×4 2.3 0.7 1.0 0.8 1.8 10.9
1×6 2.8 0.7 1.0 0.8 1.8 11.4
1×10 3.6 0.7 1.0 0.8 1.8 12.2
1×16 4.5 0.7 1.0 0.8 1.8 13.1
1×25 5.6 0.9 1.0 0.8 1.8 14.6
1×35 6.7 0.9 1.0 1.25 1.8 16.6
1×50 8.0 1 1.0 1.25 1.8 18.1
1×70 9.4 1.1 1.0 1.25 1.8 19.7
1×95 11.0 1.1 1.0 1.6 1.8 22.0
1×120 12.4 1.2 1.0 1.6 1.8 23.6
1×150 13.8 1.4 1.0 1.6 1.8 25.4
1×185 15.3 1.6 1.0 1.6 1.8 27.4
1×240 17.5 1.7 1.0 1.6 1.9 29.9
1×300 19.5 1.8 1.0 2.0 2.0 33.1
1×400 22.6 2 1.2 2.0 2.2 37.3
1×500 25.2 2.2 1.2 2.0 2.3 40.

8)Two cores low voltage cables (Galvanized steel wire armoured)

Nominal Cross Section Diameter of Conductor (Approx.) Nominal Insulation thickness Nominal Inner Covering thickness Nominal Steel Wire dia. Nominal Sheath thickness Overall Diameter (Approx.)
mm^2 mm mm mm mm mm mm
2×1.5 1.4 0.7 1.0 0.8 1.8 12.8
2×2.5 1.8 0.7 1.0 0.8 1.8 13.6
2×4 2.3 0.7 1.0 0.8 1.8 14.6
2×6 2.8 0.7 1.0 1.25 1.8 16.5
2×10 3.6 0.7 1.0 1.25 1.8 18.1
2×16 4.5 0.7 1.0 1.25 1.8 19.9
2×25 5.6 0.9 1.0 1.6 1.8 23.6
2×35 6.7 0.9 1.0 1.6 1.8 25.8
2×50 8.0 1 1.0 1.6 1.9 29.0
2×70 9.4 1.1 1.0 2.0 2.0 33.2
2×95 11.0 1.1 1.2 2.0 2.1 37.1
2×120 12.4 1.2 1.2 2.0 2.3 40.5
2×150 13.8 1.4 1.2 2.5 2.4 45.4
2×185 15.3 1.6 1.4 2.5 2.6 49.9
2×240 17.5 1.7 1.4 2.5 2.7 55.1
2×300 19.5 1.8 1.6 2.5 2.9 60.2
2×400 22.6 2 1.6 2.5 3.1 67.7

9)Three cores low voltage cables (Galvanized steel wire armoured)

Nominal Cross Section Diameter of Conductor (Approx.) Nominal Insulation thickness Nominal Inner Covering thickness Nominal Steel Wire dia. Nominal Sheath thickness Overall Diameter (Approx.)
mm^2 mm mm mm mm mm mm
3×1.5 1.4 0.7 1.0 0.8 1.8 13.2
3×2.5 1.8 0.7 1.0 0.8 1.8 14.1
3×4 2.3 0.7 1.0 0.8 1.8 15.2
3×6 2.8 0.7 1.0 1.25 1.8 17.1
3×10 3.6 0.7 1.0 1.25 1.8 18.9
3×16 4.5 0.7 1.0 1.25 1.8 20.8
3×25 5.6 0.9 1.0 1.6 1.8 24.7
3×35 6.7 0.9 1.0 1.6 1.8 27.2
3×50 8.0 1 1.0 1.6 1.9 30.6
3×70 9.4 1.1 1.0 2.0 2.1 35.2
3×95 11.0 1.1 1.2 2.0 2.2 39.3
3×120 12.4 1.2 1.2 2.0 2.3 43.0
3×150 13.8 1.4 1.4 2.5 2.5 48.6
3×185 15.3 1.6 1.4 2.5 2.7 53.0
3×240 17.5 1.7 1.4 2.5 2.8 58.5
3×300 19.5 1.8 1.6 2.5 3.0 64.0
3×400 22.6 2 1.6 3.15 3.3 73.5

10)Three cores+1 low voltage cables (Galvanized steel wire armoured)

Nominal Cross Section Diameter of Conductor (Approx.) Nominal Insulation thickness Nominal Inner Covering thickness Nominal Steel Wire dia. Nominal Sheath thickness Overall Diameter (Approx.)
mm^2 (3) mm (1) mm (3) mm (1) mm mm mm mm mm
3x 16/10 4.5 3.6 0.7 0.7 1 1.6 1.8 22.7
3x 25/16 5.6 4.5 0.9 0.7 1 1.6 1.8 26.5
3x 35/16 6.7 4.5 0.9 0.7 1 1.6 1.9 29
3x 50/25 8.0 5.6 1 0.9 1 1.6 2.1 33
3x 70/35 9.4 6.7 1.1 0.9 1.2 2 2.2 38
3x 95/50 11.0 8.0 1.1 1 1.2 2 2.3 42.4
3×120/70 12.4 9.4 1.2 1.1 1.2 2 2.5 48.0
3×150/70 13.8 9.4 1.4 1.1 1.4 2.5 2.7 52
3×185/95 15.3 11.0 1.6 1.1 1.4 2.5 2.8 57.2
3×240/120 17.5 12.4 1.7 1.2 1.6 2.5 3.1 64
3×300/150 19.5 13.8 1.8 1.4 1.6 2.5 3.2 69.8
3×400/185 22.6 15.3 2 1.6 1.6 3.15 3.6 78.6

11)Four cores low voltage cables (Galvanized steel wire armoured)

Nominal Cross Section Diameter of Conductor (Approx.) Nominal Insulation thickness Nominal Inner Covering thickness Nominal Steel Wire dia. Nominal Sheath thickness Overall Diameter (Approx.)
mm^2 mm mm mm mm mm mm
4×1.5 1.4 0.7 1.0 0.8 1.8 14.0
4×2.5 1.8 0.7 1.0 0.8 1.8 14.9
4×4 2.3 0.7 1.0 1.25 1.8 17.0
4×6 2.8 0.7 1.0 1.25 1.8 18.2
4×10 3.6 0.7 1.0 1.25 1.8 20.2
4×16 4.5 0.7 1.0 1.6 1.8 23.0
4×25 5.6 0.9 1.0 1.6 1.8 26.7
4×35 6.7 0.9 1.0 1.6 1.9 29.5
4×50 8.0 1 1.0 2.0 2.1 34.2
4×70 9.4 1.1 1.2 2.0 2.2 38.8
4×95 11.0 1.1 1.2 2.0 2.3 42.9
4×120 12.4 1.2 1.4 2.5 2.5 48.6
4×150 13.8 1.4 1.4 2.5 2.7 53.2
4×185 15.3 1.6 1.4 2.5 2.8 58.1
4×240 17.5 1.7 1.6 2.5 3.1 64.8
4×300 19.5 1.8 1.6 2.5 3.2 70.4
4×400 22.6 2 1.8 3.15 3.6 81.3

We are China 0.6/1kv Yjv22 XLPE Armoured Power Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular Armoured Cable Products

33kV MV Armour Cable 3 Core 150 mm XLPE Copper Cable

600/1000V Aluminum 3 Core 25mm Galvanized Steel Tape Armoured Cable

0.6/1kv Cu/XLPE/Swa/PVC Power Cable 4 Core 240mm

Copper Conductor XLPE Insulation Power Armoured Cable with O. 6/1kv

3.6/6kv 6/10kv 12/20kv 18/30kv 26/35kv Single/ Three Cores Cu/Al Swa/Sta Medium Voltage Power Cable

Single Core XLPE Insulated Cable with PE Sheath 18/30kv

Popular luxingcable Products

Control Cables - Cy, Sy and Yy Control Cables

Vc4V-K Cable Flexible Copper Conductor Copper Wire Screen Cable

2 Core 4mm PVC Cable/4 Core 10mm PVC Cable/2 Core 16mm PVC Cable

10mm 16mm Electrical Wire Cable House Wiring

China Supplier 120mm Low Voltage Power Cable

0.6/1kv PVC 1/2/3/4/5 Core Insulated PVC Sheathed Low Voltage Cable Waterproof Electrical Cable

Popular Steel Tape Armoured Cable Products

MV Cable Cu/Al XLPE Insulated Shielded Underground Power Cable

0.6/1kv Cu/XLPE/PVC/Sta/PVC Cable

VV22 Vlv22 Steel Tape Armoured Cu/PVC/Swa/PVC Power Cable

33kv Single Core S/C 630mm2 Cable IEC60502-2

3.6/6kv Mv 3 Core 3c120mm2 XLPE Swa Galvanized Steel Wire Armoured Power Cable 3 Core 70mm2 11kv XLPE Swa Armoured Cable

11kv XLPE Armoured Single Core 500mm2 IEC60502-2

Popular Yjv22 XLPE Power Cable Products

  • No related articles
  • Tags: , , ,

    FAST AND RELIABLE SERVICE FOR YOUR PROJECT

    Contact our trained experts today to find your perfect power solution.

    ASK A QUESTION