11kv Sz11 Type on-Load Tap Changing Distribution Transformer

11kv Sz11 Type on-Load Tap Changing Transformer

Silverstone Electric

OD

Power Frequency

Power Transformer

ISO9001-2000, UL, ISO9001, CCC

Separated Winding Transformer

Oil-immersed Type Transformer

Core-type Transformer

Three

Power, Instrument, Lighting, Rectifier

High

Silverstone Electric

Pallet / Wooden Case / Container

Refer to Drawings

China

8504329000

Product Details

Features of 10kV & 35kV oil-immersed distribution transformer
1. The features of the product structure are:
Core of transformer are made by the high quality cold-rolled grain-oriented silicon steel sheet with laser notch, cutting by the
imported world first class cut-into-length production line to ensure less shear burrs, high precision lamination, also inclined by
45° full-seam construction, making the silicon steel sheet rolling direction same as the magnetic flux direction, it can reducing
the load loss, load current and noise level.
1.2 HV winding is made with polyvinyl acetal wire enamel wire, layer type, double-sided glue dots paper are used as the layer
insulation between layers, it will stick together after dry, so that the HV winding to solidify to a solid after dry. HV winding
ampere-turns arranged by our specific technology, it will reduce axial strength during short circuit happen.
1.3 Corrugated tank structure used in the transformer design. The imported corrugated tank production line can produce the
corrugated sheet and welding seam automatically, the weld the tank rim and bottom on the welding desk, it will be
performed the leakage test after welding process finished one tank by one tank, and a finally leakage test for whole
transformer to ensure the quality of sealing.
1.4 The oil will be filling in the transformer under vacuum condition, strictly and advanced technology greatly improved the
insulation strength of transformer.
1.5 Lastest invention technology are used on designing of transformer bushing, no pressure pin and plate on the outside, it
avoids oil leakage, steel rust and etc, the structure is reasonable and contour artistic.
1.6 Oil level gauge with magnetic plate structure, it can fully isolation the oil tank and air, can ensure the quality of
transformer oil not to effect by ultraviolet radiation.
1.7 Bar-type No Circuit Tap Changer used on the transformer design, it is easy to be operated. It can be automatically and
quickly switched, and have obviously feeling during switched by hand. Effectively solve the problems of switch as other
tap-changer. Client can also add a lock to prevent the non-normal random switching according their requirement.
2. Dyn11:
The comparison of the Dyn11 and Yyn0 vector group:Both Dyn11 and Yyn0 vector group distribution transformers are
three-phase three-column type, only the insulation requirements of high-voltage winding of Dyn11 transformer, insulation
strength slightly higher than Yyn0, others are all similar. However, still big difference between those two types of transformers.
2.1 Three-column core transformer, the third harmonic flux only can circulate through the tank wall and other parts. Thus,
walls and other components will be heated cause by the stray loss. Dyn11 will much better than Yyn0 in this issue.
2.2 Zero sequence impedance of Dyn11 is much smaller than Yyn0, it is conducive to shut off load in LV side when fault
grounding happened.
2.3 Dyn11 transformer can be running even the neutral current is equal or more than 75% of phase current. Therefore, the
ability to withstand unbalanced load, Dyn11 is greater than Yyn0.
2.4 When one phase fuses in HV side of Dyn11 transformer, the other two-phase load can still run, but Yyn0 can not. So
Dyn11 vector group, the neutral potential displacement of LV side will not be affected by the unbalanced load.
2.5 Whether single-phase short circuit in LV side, or three-phase short circuit, the current is no change with the neutral
grounding type of Dyn11 transformer.
2.6 Single-phase short circuit current of Dyn11 transformer is approximately equal to three-phase short-circuits current,
which is beneficial to fuses choosing. Zero sequence impedance of Yyn0 transformer is greater than the positive and
negative sequence impedance, so the single-phase short-circuit current is less than three-phase short-circuit current, it
will take some difficult in fuses choosing.

Technical Specification

Type Rated capacity Rated Voltage (KV) Connecting Symbol No-load Loss (KW) Load Loss (KW) No-load Current (%) Short-circuit Impedance %
H.V (KV) Tapping Range of M.V L.V (KV)
SZ11-200/10 200 6
6.3
10
10.5
11
±4*2.5% 0.4 Dyn11 0.38 1.96 1.5 4
SZ11-250/10 250 0.45 2.47 1.4
SZ11-315/10 315 0.54 4.10 1.4
SZ11-400/10 400 0.64 4.96 1.3
SZ11-500/10 500 0.77 5.90 1.2
SZ11-630/10 630 0.96 7.27 1.1 4.5
SZ11-800/10 800 1.12 8.89 1.0
SZ11-1000/10 1000 1.36 10.43 1.0
SZ11-1250/10 1250 1.56 12.40 0.9
SZ11-1600/10 1600 1.92 14.79 0.8

 

Type Rated Capacity Weigt (KG) Overall Dimension (MM) Track Spacing
(MM)
Oil Total L M H
SZ11-200/10 200 250 1140 1700 850 1520 550*550
SZ11-250/10 250 280 1280 1740 880 1560 550*550
SZ11-315/10 315 310 1450 1780 920 1600 660*660
SZ11-400/10 400 340 1650 1810 960 1650 660*660
SZ11-500/10 500 390 2010 1910 1100 1800 660*660
SZ11-630/10 630 620 2940 2190 1140 2050 820*820
SZ11-800/10 800 650 3050 2250 1180 2060 820*820
SZ11-1000/10 1000 690 3210 2280 1220 2080 820*820
SZ11-1250/10 1250 800 3740 2400 1370 2180 820*820
SZ11-1600/10 1600 1000 5150 2520 1500 2150 820*820

We are China 11kv Sz11 Type on-Load Tap Changing Distribution Transformer manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular Amorphous Transformer Products

11kv Single Phase Overhead Conventional Pole Mounted Distribution Transformer

Step Voltage Regulator 11kv Voltage Stabilizer

10kv 11-33kv Sc (H) 11-30~500kVA Distribution Transformers

Type Sc (B) 10-50~3150kVA Distribution Transformer 11kv 33kv

Dry-Type 11kv 33kv Transformer Dimensions with Protection Enclosure

630~2500kVA 11kv 12kv 15kv Dry Transformers

Popular Oil Transformet Products

11kv Dry Type Power Distribution Transformer

Manufacture 11-24kv Dry-Type Power Transformer

Compact Type Three Phase Pad Mounted Distribution Transformer

Rectifier Special Transformer 11kv 33kv

230kv Level Oil-Immersed Power Transformer

69kv 66kv Oil-Immersed Power Transformer IEC Standard

Popular Power Transformer Products

Oil Immersed Distribution Transformer 11kv IEC Standard

Traction Transformer 132kv 126kv Tap Changing Oltc IEC Standard

11kv 12kv 15kv 30~1000kVA Distribution Transformers

Prefabricated Substation Transformer Enclosure 6.6kv

230kv 132kv Oil-Immersed Power Transformer IEC Standard

11kv D11 Single Phase Oil Immersed Transformer

Popular silverstone-electric Products

Station Post IEC Class Porcelain Insulator/33kv Line Post Insulator

11kv Sczb10-250~2500kVA on-Load Tap-Changing Distribution Transformer

Single Core Cold Shrinkable Outdoor Termination Kit

One Time Use Lock Seal Plastic Padlock Security Seals Lock with Metal

Expulsion Fuse Cutout / Dropout Fuse 27kv

Insulating Sleeve Polyolefin Heat Shrink Tubing

Tags: , , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION