120kv High Voltage Line Silicon Housing Lightning Diverter with External Gap
120kv High Voltage Line Silicon Housing Lightning Diverter with External Gap image
Get Latest Price Request a quote
Quick Details
Product Details
120kV Line Type Surge Diverters with External Gap
0.28kV~500kV Surge Arresters’ Characteristics:
1. The Core column applied winding structure, Polymer Housed core pillar molded on the core column, with almost no internal air gap, and outstanding sealing performance Simple in structure, small in size and light in weight.
2. Polymer Housed with silicone rubber, explosion-proof ZnO varistor as the core component is large
in flow capacity.
3. International standard IEC 60099-4 and ANSI 62.22, and with high reliability. With fully insulated tops, the product can be applied to the complete cabinet installation, which can reduce the designing size of cabinet.
4. Products with detachment device can provide signals for quitting operation when failure occurs,
avoiding arrester explosion, and it is maintenance-free.
5. Polymer housed products with a six CTI level, creepage distance meets the requirements of IV level in heavy pollution areas.
Technical Parameters:
Type | Nominal System Voltage | Rated Voltage | Minimum Reference Voltage under 1 mA DC | Residual voltages at steep impulse current | Residual voltages at lightning impulse | 1.2/50 Impulse Discharge Voltage kV< =(+) | Power Frequency Withstand Voltage | 4/10 μ S High Current (KA) | 2mS current /A | ||
5kA | 10kA | 5kA | 10kA | ||||||||
YH10CX-90/260 | 110 | 90 | 130 | 292 | 260 | 525 | 185 | 100 | 600 | ||
YH10CX-96/280 | 110 | 96 | 140 | 314 | 280 | 525 | 185 | 100 | 600 | ||
YH10CX-102/296 | 110 | 102 | 148 | 332 | 296 | 525 | 185 | 100 | 600 | ||
YH10CX-120/320 | 132 | 120 | 170 | 365 | 320 | 535 | 210 | 100 | 850 |
Working condition:
Environment temperature: -40–+40 degree | |||||||
altitude:<1000m | |||||||
48HZ<Rated frequency<62HZ | |||||||
Power frequency voltage should not be more than continuous running voltage | |||||||
Max wind speed should be less than 35m/s | |||||||
Earthquake intensity should be less than 7 degree | |||||||
If used in contamination area, should be noted in advance. |
Line discharge level from 1 to 5,
We are China 120kv High Voltage Line Silicon Housing Lightning Diverter with External Gap manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular hzyddq Products
Surge Arrester Lower Voltage Arrester Lightning
Power Transmission Line Equipment Polymer Lightning Surge Arrestor 18kv
Outdoor Polymeric Housed Metal Oxide Arresters Surge Protector for 132kv
Distribution Equipment 132kv High Voltage Metal-Oxide Polymeric Ceramic Surge Arrester
Top Selling High Power Electrical Product Fuse Cutout 24kv
Popular Lightning Arrester Products
33kv 10ka High Quality Silicone Housed Gapless Surge Diverters
5kv Gapped Lightning Arrester Surge Arrester
High-Voltage Disconnector Switch 60kv
Fuselink, Cartridge 415V - 30 AMPS -Me30A
84kv Metal Oxide Lightning Arrester for Overvoltage Protection
18kv High Voltage Electrical Lightning Arrester for Transmission Line
Popular Surge Arrester Products
0.25kv~765kv Silicon Rubber (Ceramic) Housed Metal Oxide Gapless Surge Arrester with Kema Type Test
24kv Station Class Composite ZnO Lightning Arrester Surge Diverter
36kv Yh10cx High Voltage Equipment Metal Silicone Polymer Arrester
21kv High Voltage Electrical Surge Arrester for Transmission Line
Moa/Metal Oxide Lightning Arrester /Metal Oxide Surge Arrester
Popular Surge Arresters Products
Rated Voltage 110kv Mcov 86kv Porcelain Ceramic Housed Lightning Arrestor
Station Class Ceramic Housed Gapless ZnO Arresters
Medium Voltage 18kv 10ka Composite Zinc Oxide Surge Arrester
21kv 10ka Polymer Housed Surge Arrester
Polymer Housed Metal Oxide Surge Arrester Without Gaps
Medium Voltage Polymeric Housed Lightning Protection Protector
Tags: hzyddq, Lightning Arrester, Surge Arrester, Surge Arresters