Product Details

Center Break Isolator and double Break Isolator

 

These disconnectors are , no load switching devices
which physically isolate the lines. They are designed for
horizontal outdoor application and can also be designed
for vertical installation. For earthing and closing of
switchyard portions of the installation, the earthing
switches are provided on disconnector. If required.

The following documents were referred to during the preparation of this specification. In case of conflict, the provisions of this specification shall take precedence.
IEC 129:1975: Alternating Current Disconnectors (Isolators) and Earthing Switches
IEC 60694:2002: Common Specifications for High Voltage Switchgear and Controlgear
BS 729: Hot dip galvanized coating on iron and steel articles
IEC62271-102
Isolator (Disconnector) – a mechanical switching device which provides, in the open position, an isolating distance in accordance with Electrical Safety requirements.

SERVICE CONDITIONS
The isolator shall be suitable for continuous operation outdoors in tropical areas at altitudes of up to 2200m above sea level, humidities of up to 90%, average ambient temperature of +30ºC with a minimum of -1ºC and a maximum of +40ºC and heavy saline conditions along the coast.

4.2. DESIGN AND CONSTRUCTION
4.2.1 The Isolator, Solid Link shall be designed and constructed in accordance with IEC 129 and IEC 60694.
4.2.2 The isolating link shall be of the vertical opening, designed for single phase manual operation. It shall be easily removed and replaced by using a portable operating rod.
4.2.3 The isolating link shall incorporate double porcelain insulators to suit voltage requirements and mounted on hot dipped galvanised steel under base suitable for vertical mounting.
4.2.4 The isolating link shall be arranged so that each unit is mounted independently on an angle bracket. It shall be supplied complete with the angle bracket and accessories suitable for mounting on ‘U’ type steel channel. The drawings to be submitted shall indicate all the applicable mounting positions.
4.2.5 The isolator shall be designed such that in fully open position, it shall provide adequate electrical isolation between the contacts on each phase. It shall conform to the requirement as single point isolation for safety.
4.2.6 All steel parts shall be hot dip galvanized to BS 729. The minimum coating of galvanizing required is 80 microns.
4.2.7 The solid link shall be removable from the mounting by use of operating rod.
4.2.8 All current carrying parts of the isolator shall be made of high conductivity material.
4.2.9 The isolator shall be fitted with clamp connectors for Aluminium (ACSR) conductor of Aluminium (ACSR)conductor of up to 18.2mm diameter.

The rating of the complete isolator shall be as follows: –
Rated voltage
36 kV
Rated frequency
50 Hz
Rated lightning impulse withstand voltage
200 kV
Rated power frequency withstand voltage, dry
95 kV
Rated normal current
400 Amps
Rated short time withstand current for 3 sec, min.
18.0 kA
Minimum creepage distance of insulators
900 mm
 

We are China 120sqmm Bimetallic Cable Lugs for Hv Side of Transformer manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular Disconnector Switch Products

Hgw9 Series 12kv Hv Outdoor High Voltage Disconnect Switch

Flexible Steel Cable

Factory Price High Voltage AC 12kv Outdoor Disconnect Switch

Gsy High Voltage Electroscope

Outdoor Pole Mount Type Gas Insulated Load Break Switch

11kv 630A Outdoor Air Break Switch

Popular jgtrade1 Products

34.5/0.433kv, 315kVA Pole Mounted Distribution Transformer

Yh10W-6, 6kv 10ka Surge Arrester

54-1 Strain Insulator Porcelain Brown

18g PU Glovesnylon Black 6-11

55-4 Ceramic Insulator

Terminal Connectors Bolted Type, Type SL, Group a

Popular Rotary Switch Products

PVC Grounding Wire Barrel

Suspension Clamp

Gw High Voltage Isolation Disconnecting Outdoor Type Disconnector Switch

Electroscope

12kv Load Isolators

Top Selling High Power Electrical Product Fuse Cutout 24kv

Popular Switch Disconnector Products

Clamp, Hot Line

Pg Series

33kv 800A Load Isolators

Cutouts Fuses 34.5kv

High-Voltage Disconnector Switch 27kv

OEM Accept High Voltage Outdoor Disconnect Switch Disconnector

Tags: , , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION