Clamp, Hot Line

China 
                        Clamp, Hot Line
                      manufacture and supplier

Clamp, Hot Line image

Get Latest Price Request a quote

Quick Details

Clamp, Hot Line

CH

Oei Power

IEC IEEE

Manual

Ist

Turn the Horizontal

Three

Single Ground

Three Pole

Horizontal Rotary Type

Grounding

Manual

Outdoor High-voltage

Three-column Disconnector

High-voltage

OEI Power

Wooden Case

IEC IEEE

China Nanyang

8535309000

Product Details

Center Break Isolator and double Break Isolator
 

3 Catalog and manufacturer reference code   Specify code and attach technical catalog of the model proposed by the manufacturer
4 Connector name   Removable connector for esribo
5 Manufacturing raw material   Outer casing: Aluminum alloy, bimetallic Inner wedge: Aluminum alloy
6 Rules   ANSI C119-4, ASTM 153
7 Quality certificate   ISO 9001
8 DN-DS certificate   Attach acceptance certificate and 
homologation 
9 Raw material of the body   Specify
10 Galvanized   Hot dip
  characteristics    
11 Main range AWG 2/0 -2
12 Connection diameter 
maximum derivation 
  1 (13/32)
13 Minimum derivation connection diameter   4 (3/16)
14 DN-DS certificate   Attach acceptance certificate and 
homologation 
15 Identification mark   Each connector must be marked on the body with the manufacturer’s symbol, catalog number, application conductor ranges and number of die to be occupied with the hydraulic tool for its 
installation 
16 Packing   The connectors must be in a package that indicates on the outside the range of application and prevent external agents from damaging it and causing premature oxidation.

 

These disconnectors are , no load switching devices
which physically isolate the lines. They are designed for
horizontal outdoor application and can also be designed
for vertical installation. For earthing and closing of
switchyard portions of the installation, the earthing
switches are provided on disconnector. If required.

The following documents were referred to during the preparation of this specification. In case of conflict, the provisions of this specification shall take precedence.
IEC 129:1975: Alternating Current Disconnectors (Isolators) and Earthing Switches
IEC 60694:2002: Common Specifications for High Voltage Switchgear and Controlgear
BS 729: Hot dip galvanized coating on iron and steel articles
IEC62271-102
Isolator (Disconnector) – a mechanical switching device which provides, in the open position, an isolating distance in accordance with Electrical Safety requirements.

SERVICE CONDITIONS
The isolator shall be suitable for continuous operation outdoors in tropical areas at altitudes of up to 2200m above sea level, humidities of up to 90%, average ambient temperature of +30ºC with a minimum of -1ºC and a maximum of +40ºC and heavy saline conditions along the coast.

4.2. DESIGN AND CONSTRUCTION
4.2.1 The Isolator, Solid Link shall be designed and constructed in accordance with IEC 129 and IEC 60694.
4.2.2 The isolating link shall be of the vertical opening, designed for single phase manual operation. It shall be easily removed and replaced by using a portable operating rod.
4.2.3 The isolating link shall incorporate double porcelain insulators to suit voltage requirements and mounted on hot dipped galvanised steel under base suitable for vertical mounting.
4.2.4 The isolating link shall be arranged so that each unit is mounted independently on an angle bracket. It shall be supplied complete with the angle bracket and accessories suitable for mounting on ‘U’ type steel channel. The drawings to be submitted shall indicate all the applicable mounting positions.
4.2.5 The isolator shall be designed such that in fully open position, it shall provide adequate electrical isolation between the contacts on each phase. It shall conform to the requirement as single point isolation for safety.
4.2.6 All steel parts shall be hot dip galvanized to BS 729. The minimum coating of galvanizing required is 80 microns.
4.2.7 The solid link shall be removable from the mounting by use of operating rod.
4.2.8 All current carrying parts of the isolator shall be made of high conductivity material.
4.2.9 The isolator shall be fitted with clamp connectors for Aluminium (ACSR) conductor of Aluminium (ACSR)conductor of up to 18.2mm diameter.

The rating of the complete isolator shall be as follows: –
Rated voltage
36 kV
Rated frequency
50 Hz
Rated lightning impulse withstand voltage
200 kV
Rated power frequency withstand voltage, dry
95 kV
Rated normal current
400 Amps
Rated short time withstand current for 3 sec, min.
18.0 kA
Minimum creepage distance of insulators
900 mm
 

We are China Clamp, Hot Line manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular Disconnector Switch Products

Isolator, Gang Operated

Outdoor Single Pole Fused Recloser by-Pass Switches 11kv

Railway Solid-Core Porcelain Station Glass Insulator

33kv Isolator Current 2000A with Earth Switch Isolator

Strain Clamps for ACSR/as Conductor Hydraulic Compression Type

Pg Series

Popular jgtrade1 Products

Polymeric Expulsion Fuses 27kv 100A

Cable Clamp

Support Type Tubular Bus-Bar Flexible Fittings Type Mgsz

11kv Load Isolators

High Voltage Toughened Glass Disc Insulators

36kv 400A Load Isolators

Popular Rotary Switch Products

Terminal Connectors Bolted Type, Type SL, Group B

Fuse Holder for 200A

24kv 3 Phase Outdoor Switch Disconnector

12kv Load Isolators

Lug, 2 Hole 4/0

High and Low Voltage Electroscope

Popular Switch Disconnector Products

Type “ -” Earthwire to Earthwire

Electrical Accessory Polymer Ceramic Fusible Cutout Fuse with ISO9001

Air Break Swich Isolator Disconnector Switch 11kv

Ydf-021 Price of 33kv High Voltage Porcelain Fuse Cutout Switch

Insulator LV Bobbin 76 X 65

Load Break Disconnect Switch IEC Standard Gw17

Tags: , , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION