12kv High Voltage Drop out Fuses

China 
                        12kv High Voltage Drop out Fuses
                      manufacture and supplier

12kv High Voltage Drop out Fuses image

Get Latest Price Request a quote

Quick Details

12kv High Voltage Drop out Fuses

DTF-12KV

IEC IEEE

Fuse Link

T K

Circle

High Voltage

Distribution

High

OEIpower

Cartons Pallets Wooden Case

IEC IEEE

China Nanyang

85351000

Product Details

 The Fuse Cutout type OEI was developed to operate in overhead distribution systems rated at 11
kV to 38 kV grounded systems with 100 or 200 A nominal currents.
Especially designed to protect transformers, capacitors, cables or lines.
It is robust construction, made of rigorously tested material, will interrupt all faults under the
most severe conditions, maintaining mechanical and electric characteristics.
The inserts, hardware and structural bolts and nuts are made from heavy galvanized steel.
The Fuse Cutout type OEI can be applied on all three-phase system rated at or below the maximum
operational rating of the cutout.
 

Performance Characteristic
Applied standard IEEE C37.42-2009
Catalog number  
Nominal system voltage kV 33
Rated Frequency Hz 50
Rated m aximum(design) voltage 38
Rated Continuous current A-RMS 100
Rated Interrupting current asymmetrical/symmetrical A-RMS 8000/5000
BIL 1.2×50 µs kV-peak 150
Minimum critical impulse flashover voltage(CFO)KV peak 165
Dry withstand voltage kV-RMS 70
Wet withstand voltage kV-RMS 60
Creepage distance to group Min.mm 650
Minimum creepage factor of insulator (Creepage Distance/arcing distance) 2.3
HIGH VOLTAGE EXPULSION TYPE FUSE LINKS
 
                                           TABLE OF CONTENTS
 
ITEM                                                                                                                           TITLE                                              PAGE
 
PART 1 GENERAL
 
1.01                                                                                                                             SCOPE                                                    E13 1
 
1.02                                                                                                                             STANDARDS                                                E13 1
 
1.03                                                                                                                             SERVICE CONDITIONS                                           E13 2
 
1.04                                                                                                                             SYSTEM CONDITIONS                                     E13 2
 
1.05                                                                                                                             TESTING                                                       E13 2
 
1.06                                                                                                                             SPARES                                                         E13 3
 
1.07                                                                                                                             PACKING AND SHIPMENT                                    E13 3
 
1.08                                                                                                                             SUBMITTALS                                               E13 3
 
PART 2 PRODUCTS
 
2.01                                                                                                                             DESIGN                                                         E13 4
 
A.                                                                                                                    Standardization of Fuse Links                        E13 4
B.                                                                                                                    Rating of Fuse Links                                      E13 4
C.                                                                                                                    Characteristics of Fuse Links                                 E13 4
 
2.02                                                                                                                             MATERIALS                                                        E13 4
 
A.                                                                                                                    Current Carrying Parts of Fuse Links                                  E13 4
B.                                                                                                                    Fuse Link Button                                     E13 5
C.                                                                                                                    Length of Fuse Links                                      E13 5
D.                                                                                                                    Pull on Fuse Links                                          E13 5
E.                                                                                                                     Identification                                                  E13 5
 
TECHNICAL DATA SCHEDULE                                                                                           E13 6

 

PART 1           GENERAL
 
1.01       SCOPE
 
This Specification covers the design, manufacturing, testing, supply, delivery and performance requirements of HV Expulsion Type Fuse Links for use by the Electricity Company of Ghana Limited.
 
1.02     STANDARDS
 
The fuse links shall comply with the latest editions of and amendments to, the standards/specifications listed below:
 
IEC                                                   –      International Electrotechnical Commission
 
IEC 60282                                 –      High Voltage Fuses Part 2: Expulsion and similar fuses
 
ANSI                                                      American National Standards Institute
 
IEEE C37.41                             –      Design for High Voltage Fuses, Distribution Enclosed Single Pole Air Switches.  Fuse Disconnecting Switches and Accessories.
 
ANSI C37.42                             –      American National Standard Specifications for Distribution Cutouts and Fuse Links.
 
NEMA                                                    National Electrical Manufacturers Association
 
NEMA SG2                               –      High Voltage Fuses

 

 
 
1.03     SERVICE CONDITIONS
 
As in Specification H0C
 
 
1.04     SYSTEM CONDITIONS
 
As in Specification H0C
 
 
1.05     TESTING
 
Type Tests
 
A.        The Supplier shall confirm on the attached schedule that the following tests have been performed according to ANSI C37.42.
 
1.         Melting Current Tests; Table 6
 
2.         Temperature Rise Tests
 
3.         Time/Current Characteristic Tests
 
B.        Type/Design Tests may (at the Purchaser’s discretion) be dispensed with if the Supplier/Contractor furnishes evidence to the Purchaser’s satisfaction that the relevant tests have already been performed on identical equipment.  In this case the Supplier shall provide documentary proof in the form of Certified Test Certificates that the assembled equipment and its component parts been successfully typetested by an independent testing authority in accordance with the relevant clauses of referenced Standards.  Test Certificates as evidence of successful completion of type tests shall be submitted as part of the Bid.
 
C.        Inspection
 

 

The Purchaser reserves the right to witness the manufacturing process, any type tests specifically performed on the materials to be supplied to Customer  and any routine tests required in the manufacture and supply of such equipment.  The Supplier shall provide free access to the Purchaser to any site where such manufacturing process, or  tests, either type or routine tests are taking place.  The Supplier shall bear the in plant costs of such witness.  The Supplier shall provide the Purchaser of a schedule of manufacture and tests at least two weeks before the events are to occur.
 
 
1.06     SPARES
 
(NOT APPLICABLE)
 
 
1.07     PACKING AND SHIPMENT
 
As in Specification H0C
        
 
1.08     SUBMITTALS
 
As in Specification H0C

 

PART 2           PRODUCTS
 
2.01     DESIGN
 
A.        Standardization of Fuse Links (Mechanical/Interchangeable).
 
High voltage expulsion fuses shall be suitable for use on the Expulsion fusegears described in the associated specifications H16 and H34.
 
B.        Rating of Fuse Links
 
The preferred rating of fuse links shall be 3A, 5A, 8A, 16A, 25A, 40A, 63A and 100A at 11kV and 1A, 2A, 3A, 5A, 8A, 16A, 20A and 31.5A at 33kV.  The rated current of the fuse link is the maximum current which it will carry continuously without deterioration and undue heating.  Supplier shall state on the attached schedule the maximum temperature in oC attained by the fuse link after continuous operation at maximum rating.
 
C.        Performance Characteristics of Fuse Links
 
1.         The fuse links are required to give protection against short circuits.  They shall be so rated and shall have such blowing characteristics as to be suitable for selective operations with the fuse links at present in use on the system namely Type K i.e. fast, fuse links to NEMA SG2 and ANSI C37.42 1981.
 
2.         The Supplier shall present to the Purchaser timecurrent characteristics of all the distribution fuselinks on offer.  The performance characteristics of the fuselinks shall include:
 
(a)        Meltingtimecurrent characteristics
(b)        Total clearingtimecurrent
 
The timecurrent characteristics shall be presented as curves.
 
The Supplier shall state the minimum and maximum melting currents required to melt the fuse links at the three appropriate time points used in Table 6 {meltingcurrents for TypeK (fast) fuse links) of ANSI C37.42 1981
 
 
2.02       MATERIALS
 
A.        Current carrying Parts of Fuse Links
 
All current carrying parts of the fuse links shall be nonferrous material; the main requirements being resistance to atmospheric corrosion.  Tin is not acceptable as a possible element.
 

 

Supplier shall state composition of:
 
1.         Fuse Element
 
2.         Fuse Link
 
B.        Fuse Link Button
 
The diameter of the button head cap on fuse links shall be 19.1mm.  Removable type button heads are preferred for use with 11kV fusegear.
 
C.        Length of Fuse Links
 
The minimum overall length of fuse links rated 1 to 100 amperes shall be:
 
:           510mm for 11kV units per ANSI C.37.42
 
:           762mm for 33kV units per ANSI C.37.42
 
D.        Pull on Fuse Links (Tensile Withstand Strength)
 
The expulsion fusegear shall operate satisfactorily while exerting a pull of 44.5N on the fuse link per ANSI C.37.42, 3.2.3.4 1981.
 
E.         Identification
 
Each fuse link must have stamped on it:
 
1.         Manufacturers name or identifying mark
 
2.         Continuous current rating
 
3.         Type designation, K or T
 
 
 
 
 
 
 
 
 
 
 
 

 

We are China 12kv High Voltage Drop out Fuses manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular Drop out Fuses Products

Polymer Fuse Cutout, Drop out Fuses 12 Kv 200A

Polymer Fuse Cutout, Drop out Fuses 18kv 200A

Supports for Tubular Bus-Bar Type Mggb

Polymer Fuse Cutout, Drop out Fuses 18 Kv 100A

Polymer Fuse Cutout 36kv 200A

Polymer Fuse Cutout, Drop out Fuses 12 Kv 100A

Popular Fuse Cutout Products

RW12-15/100A-200A 15kv Outdoor High Voltage Porcelain Drop-out Fuse with High Quality

Jbll-50 (70)

24kv 100A 200A Drop out Fuse Cutout

36kv Outdoor Expulsion Drop-out Type Loadbreak Fuse Cutout

18kv Outdoor High Voltage Polymer Fuse Cutout

Polymer Fuse Cutout, Drop out Fuses 27 Kv 100A

Popular High Voltage Fuse Products

Cutout Fuse 300A

French Standard High Voltage Fuses Vvpa Type Xrnp

PP Clear/Anti-Fog

Polyester Glove Nitrie Coated, Smooth Finish. (red)

Deflectors Folder (towers)

24kv Expulsion Fuse Element

Popular jgtrade1 Products

Dead End/Anchoring Clamp25-70sqmm

Best Price24kv 100A Ceramic Types Drop out Fuses Cutout/Cut out Fuse

36kv Expulsion Fuse Element

Hy5ws-7.6/30 Zinc-Oxide Arrester

Nlz-2 Deadend Clamp

Isolator Rocking 33kv C/W Int Head & Per

Tags: , , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION