33kv XLPE Insulated Unarmoured Electric Cable, Power Cable
33kv XLPE Insulated Unarmoured Electric Cable, Power Cable image
Get Latest Price Request a quote
Quick Details
Product Details
Application:
Media Voltage XLPE Insulated power cable is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable.
Prpperty:
1.The highest allowed operating temperature of conductor for long-term working is 90 degrees.
2.In short circuit (Max long term is no more than 5 seconds). The highest temperature for conductor is no more than 250 degrees.
3.The cable is laid without horizontal drop limit. The environment temperature should be no lower than 0 when lay. Otherwise it should be preheated.
4.Excellent electrical performance, resistance to chemical corrosion.
5.They can stand advisable traction when laid.They can stand traction from Outside.Left low smoke halogen-free after burned.Retard the burning of the cable.
Specification:
IEC60502,designing and manufacturing special power cable according to the other standards required by the customers.
1)3.6/6(7.2)kV,3.6/6.6(7.2)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable
Normal Cross Section of Conductor | Normal Diameter of Conductor | Normal Thickness of Insulation | Normal Thickness of Copper Tape |
Normal Thickness of Outer Sheath | Approx. Overall Dia. |
Approx. Net Weight | Max. D.C. Resistance of Conductor at 20ºC | ||
Al Conductor | Cu Conductor | Al Conductor | Cu Conductor | ||||||
mm2 | mm | mm | mm | mm | mm | kg/m | kg/m | Ω/km | Ω/km |
25 | 6.0 | 2.5 | 0.12 | 1.5 | 17.6 | 0.34 | 0.49 | 1.2000 | 0.7270 |
35 | 7.0 | 2.5 | 0.12 | 1.5 | 18.5 | 0.39 | 0.60 | 0.8680 | 0.5240 |
50 | 8.3 | 2.5 | 0.12 | 1.6 | 20.0 | 0.46 | 0.74 | 0.6410 | 0.3870 |
70 | 9.7 | 2.5 | 0.12 | 1.6 | 21.5 | 0.55 | 0.96 | 0.4430 | 0.2680 |
95 | 11.3 | 2.5 | 0.12 | 1.7 | 23.3 | 0.66 | 1.23 | 0.3200 | 0.1930 |
120 | 13 | 2.5 | 0.12 | 1.7 | 24.8 | 0.77 | 1.48 | 0.2530 | 0.1530 |
150 | 14.6 | 2.5 | 0.12 | 1.8 | 26.4 | 0.87 | 1.77 | 0.2060 | 0.1240 |
185 | 15.9 | 2.5 | 0.12 | 1.8 | 28.1 | 1.01 | 2.13 | 0.1640 | 0.0991 |
240 | 18.3 | 2.6 | 0.12 | 1.9 | 30.9 | 1.23 | 2.71 | 0.1250 | 0.0754 |
300 | 20.4 | 2.8 | 0.12 | 2.0 | 33.6 | 1.48 | 3.32 | 0.1000 | 0.0601 |
400 | 23.2 | 3.0 | 0.12 | 2.1 | 37.0 | 1.81 | 4.16 | 0.0778 | 0.0470 |
500 | 26.4 | 3.2 | 0.12 | 2.2 | 41.1 | 2.24 | 5.27 | 0.0605 | 0.0366 |
630 | 30.1 | 3.2 | 0.12 | 2.3 | 45.0 | 2.73 | 6.62 | 0.0469 | 0.0283 |
2)6/10(12)kV,6.35/11(12)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable
Normal Cross Section of Conductor | Normal Diameter of Conductor | Normal Thickness of Insulation | Normal Thickness of Copper Tape |
Normal Thickness of Outer Sheath | Approx. Overall Dia. |
Approx. Net Weight | Max. D.C. Resistance of Conductor at 20ºC | |||
Al Conductor | Cu Conductor | Al Conductor | Cu Conductor | |||||||
mm2 | mm | mm | mm | mm | mm | kg/m | kg/m | Ω/km | Ω/km | |
25 | 6.0 | 3.4 | 0.12 | 1.5 | 19.4 | 0.40 | 0.55 | 1.2000 | 0.7270 | |
35 | 6.9 | 3.4 | 0.12 | 1.6 | 20.5 | 0.45 | 0.66 | 0.8680 | 0.5240 | |
50 | 8.2 | 3.4 | 0.12 | 1.6 | 21.8 | 0.52 | 0.80 | 0.6410 | 0.3870 | |
70 | 9.7 | 3.4 | 0.12 | 1.7 | 23.5 | 0.62 | 1.03 | 0.4430 | 0.2680 | |
95 | 11.3 | 3.4 | 0.12 | 1.7 | 25.1 | 0.73 | 1.30 | 0.3200 | 0.1930 | |
120 | 12.8 | 3.4 | 0.12 | 1.8 | 26.8 | 0.85 | 1.56 | 0.2530 | 0.1530 | |
150 | 14.2 | 3.4 | 0.12 | 1.8 | 28.2 | 0.95 | 1.85 | 0.2060 | 0.1240 | |
185 | 15.9 | 3.4 | 0.12 | 1.9 | 30.1 | 1.10 | 2.22 | 0.1640 | 0.0991 | |
240 | 18.3 | 3.4 | 0.12 | 2.0 | 32.7 | 1.33 | 2.80 | 0.1250 | 0.0754 | |
300 | 20.4 | 3.4 | 0.12 | 2.0 | 34.8 | 1.54 | 3.39 | 0.1000 | 0.0601 | |
400 | 23.2 | 3.4 | 0.12 | 2.2 | 38.0 | 1.87 | 4.22 | 0.0778 | 0.0470 | |
500 | 26.4 | 3.4 | 0.12 | 2.2 | 41.5 | 2.26 | 5.29 | 0.0605 | 0.0366 | |
630 | 30.1 | 3.4 | 0.12 | 2.4 | 45.6 | 2.78 | 6.67 | 0.0469 | 0.0283 |
3)8.7/10(15)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable
Normal Cross Section of Conductor | Normal Diameter of Conductor | Normal Thickness of Insulation | Normal Thickness of Copper Tape |
Normal Thickness of Outer Sheath | Approx. Overall Dia. |
Approx. Net Weight | Max. D.C. Resistance of Conductor at 20ºC | |||
Al Conductor | Cu Conductor | Al Conductor | Cu Conductor | |||||||
mm2 | mm | mm | mm | mm | mm | kg/m | kg/m | Ω/km | Ω/km | |
25 | 6.0 | 4.5 | 0.12 | 1.6 | 21.8 | 0.48 | 0.63 | 1.2000 | 0.7270 | |
35 | 6.9 | 4.5 | 0.12 | 1.7 | 22.9 | 0.54 | 0.75 | 0.8680 | 0.5240 | |
50 | 8.2 | 4.5 | 0.12 | 1.7 | 24.2 | 0.61 | 0.89 | 0.6410 | 0.3870 | |
70 | 9.7 | 4.5 | 0.12 | 1.8 | 25.9 | 0.72 | 1.13 | 0.4430 | 0.2680 | |
95 | 11.3 | 4.5 | 0.12 | 1.8 | 27.5 | 0.84 | 1.40 | 0.3200 | 0.1930 | |
120 | 12.8 | 4.5 | 0.12 | 1.9 | 29.2 | 0.96 | 1.67 | 0.2530 | 0.1530 | |
150 | 14.2 | 4.5 | 0.12 | 1.9 | 30.6 | 1.06 | 1.96 | 0.2060 | 0.1240 | |
185 | 15.9 | 4.5 | 0.12 | 2.0 | 32.5 | 1.22 | 2.34 | 0.1640 | 0.0991 | |
240 | 18.3 | 4.5 | 0.12 | 2.1 | 35.1 | 1.46 | 2.93 | 0.1250 | 0.0754 | |
300 | 20.4 | 4.5 | 0.12 | 2.1 | 37.2 | 1.68 | 3.52 | 0.1000 | 0.0601 | |
400 | 23.2 | 4.5 | 0.12 | 2.2 | 40.2 | 2.00 | 4.35 | 0.0778 | 0.0470 | |
500 | 26.4 | 4.5 | 0.12 | 2.3 | 43.9 | 2.43 | 5.45 | 0.0605 | 0.0366 | |
630 | 30.1 | 4.5 | 0.12 | 2.4 | 47.8 | 2.93 | 6.83 | 0.0469 | 0.0283 |
4)12/20(24)kV, 12.7/22(24)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable
Normal Cross Section of Conductor | Normal Diameter of Conductor | Normal Thickness of Insulation | Normal Thickness of Copper Tape |
Normal Thickness of Outer Sheath | Approx. Overall Dia. |
Approx. Net Weight | Max. D.C. Resistance of Conductor at 20ºC | ||
Al Conductor | Cu Conductor | Al Conductor | Cu Conductor | ||||||
mm2 | mm | mm | mm | mm | mm | kg/m | kg/m | Ω/km | Ω/km |
25 | |||||||||
35 | 6.9 | 5.5 | 0.12 | 1.7 | 24.9 | 0.62 | 0.83 | 0.8680 | 0.5240 |
50 | 8.2 | 5.5 | 0.12 | 1.8 | 26.4 | 0.70 | 0.98 | 0.6410 | 0.3870 |
70 | 9.7 | 5.5 | 0.12 | 1.8 | 27.9 | 0.80 | 1.21 | 0.4430 | 0.2680 |
95 | 11.3 | 5.5 | 0.12 | 1.9 | 29.7 | 0.94 | 1.50 | 0.3200 | 0.1930 |
120 | 12.8 | 5.5 | 0.12 | 1.9 | 31.2 | 1.05 | 1.77 | 0.2530 | 0.1530 |
150 | 14.2 | 5.5 | 0.12 | 2.0 | 32.8 | 1.17 | 2.07 | 0.2060 | 0.1240 |
185 | 15.9 | 5.5 | 0.12 | 2.0 | 34.5 | 1.33 | 2.45 | 0.1640 | 0.0991 |
240 | 18.3 | 5.5 | 0.12 | 2.1 | 37.1 | 1.57 | 3.04 | 0.1250 | 0.0754 |
300 | 20.4 | 5.5 | 0.12 | 2.2 | 39.4 | 1.81 | 3.66 | 0.1000 | 0.0601 |
400 | 23.2 | 5.5 | 0.12 | 2.3 | 42.4 | 2.14 | 4.49 | 0.0778 | 0.0470 |
500 | 26.4 | 5.5 | 0.12 | 2.4 | 46.1 | 2.58 | 5.61 | 0.0605 | 0.0366 |
630 | 30.1 | 5.5 | 0.12 | 2.4 | 49.8 | 3.10 | 6.99 | 0.0469 | 0.0283 |
5)18/30(36)kV,19/33(36)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable
Normal Cross Section of Conductor | Normal Diameter of Conductor | Normal Thickness of Insulation | Normal Thickness of Copper Tape |
Normal Thickness of Outer Sheath | Approx. Overall Dia. |
Approx. Net Weight | Max. D.C. Resistance of Conductor at 20ºC | |||
Al Conductor | Cu Conductor | Al Conductor | Cu Conductor | |||||||
mm2 | mm | mm | mm | mm | mm | kg/m | kg/m | Ω/km | Ω/km | |
25 | ||||||||||
35 | ||||||||||
50 | 8.2 | 8.0 | 0.12 | 2.0 | 31.8 | 0.95 | 1.23 | 0.6410 | 0.3870 | |
70 | 9.7 | 8.0 | 0.12 | 2.0 | 33.3 | 1.07 | 1.47 | 0.4430 | 0.2680 | |
95 | 11.3 | 8.0 | 0.12 | 2.1 | 35.1 | 1.21 | 1.78 | 0.3200 | 0.1930 | |
120 | 12.8 | 8.0 | 0.12 | 2.1 | 36.6 | 1.34 | 2.05 | 0.2530 | 0.1530 | |
150 | 14.2 | 8.0 | 0.12 | 2.2 | 38.2 | 1.47 | 2.37 | 0.2060 | 0.1240 | |
185 | 15.9 | 8.0 | 0.12 | 2.2 | 39.9 | 1.64 | 2.76 | 0.1640 | 0.0991 | |
240 | 18.3 | 8.0 | 0.12 | 2.3 | 42.5 | 1.90 | 3.37 | 0.1250 | 0.0754 | |
300 | 20.4 | 8.0 | 0.12 | 2.4 | 44.8 | 2.16 | 4.01 | 0.1000 | 0.0601 | |
400 | 23.2 | 8.0 | 0.12 | 2.4 | 47.6 | 2.52 | 4.87 | 0.0778 | 0.0470 | |
500 | 26.4 | 8.0 | 0.12 | 2.5 | 51.3 | 2.98 | 6.01 | 0.0605 | 0.0366 | |
630 | 30.1 | 8.0 | 0.12 | 2.6 | 55.2 | 3.54 | 7.43 | 0.0469 | 0.0283 |
6)3.6/6(7.2)kV,3.6/6.6(7.2)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable
Normal Cross Section of Conductor | Normal Diameter of Conductor | Normal Thickness of Insulation | Normal Thickness of Copper Tape |
Normal Thickness of Outer Sheath | Approx. Overall Dia. |
Approx. Net Weight | Max. D.C. Resistance of Conductor at 20ºC | ||||
Al Conductor | Cu Conductor | Al Conductor | Cu Conductor | ||||||||
mm2 | mm | mm | mm | mm | mm | kg/m | kg/m | Ω/km | Ω/km | ||
25 | 6.0 | 2.5 | 0.1 | 2.0 | 34.6 | 1.13 | 1.58 | 1.2000 | 0.7270 | ||
35 | 6.9 | 2.5 | 0.1 | 2.1 | 36.8 | 1.29 | 1.92 | 0.8680 | 0.5240 | ||
50 | 8.2 | 2.5 | 0.1 | 2.2 | 39.8 | 1.51 | 2.36 | 0.6410 | 0.3870 | ||
70 | 9.7 | 2.5 | 0.1 | 2.3 | 43.2 | 1.81 | 3.04 | 0.4430 | 0.2680 | ||
95 | 11.3 | 2.5 | 0.1 | 2.4 | 46.9 | 2.17 | 3.87 | 0.3200 | 0.1930 | ||
120 | 12.8 | 2.5 | 0.1 | 2.4 | 50.1 | 2.53 | 4.69 | 0.2530 | 0.1530 | ||
150 | 14.2 | 2.5 | 0.1 | 2.5 | 53.3 | 2.90 | 5.60 | 0.2060 | 0.1240 | ||
185 | 15.9 | 2.5 | 0.1 | 2.6 | 57.2 | 3.40 | 6.77 | 0.1640 | 0.0991 | ||
240 | 18.3 | 2.6 | 0.1 | 2.8 | 63.2 | 4.12 | 8.55 | 0.1250 | 0.0754 | ||
300 | 20.4 | 2.8 | 0.1 | 3.0 | 69.0 | 4.89 | 10.46 | 0.1000 | 0.0601 | ||
400 | 23.2 | 3.0 | 0.1 | 3.4 | 76.7 | 6.10 | 13.18 | 0.0778 | 0.0470 | ||
500 | 26.4 | 3.2 | 0.1 | 3.6 | 85.7 | 8.10 | 16.55 | 0.0605 | 0.0366 |
7)6/10(12)kV,6.35/11(12)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable
Normal Cross Section of Conductor | Normal Diameter of Conductor | Normal Thickness of Insulation | Normal Thickness of Copper Tape |
Normal Thickness of Outer Sheath | Approx. Overall Dia. |
Approx. Net Weight | Max. D.C. Resistance of Conductor at 20ºC | |||
Al Conductor | Cu Conductor | Al Conductor | Cu Conductor | |||||||
mm2 | mm | mm | mm | mm | mm | kg/m | kg/m | Ω/km | Ω/km | |
25 | 6.0 | 3.4 | 0.1 | 2.1 | 38.7 | 1.30 | 1.75 | 1.2000 | 0.7270 | |
35 | 6.9 | 3.4 | 0.1 | 2.2 | 40.9 | 1.47 | 2.22 | 0.8680 | 0.5240 | |
50 | 8.2 | 3.4 | 0.1 | 2.3 | 43.9 | 1.70 | 2.50 | 0.6410 | 0.3870 | |
70 | 9.7 | 3.4 | 0.1 | 2.4 | 47.3 | 2.02 | 3.25 | 0.4430 | 0.2680 | |
95 | 11.3 | 3.4 | 0.1 | 2.5 | 51.0 | 2.42 | 4.12 | 0.3200 | 0.1930 | |
120 | 12.8 | 3.4 | 0.1 | 2.6 | 54.4 | 2.79 | 4.95 | 0.2530 | 0.1530 | |
150 | 14.2 | 3.4 | 0.1 | 2.7 | 57.6 | 3.17 | 5.87 | 0.2060 | 0.1240 | |
185 | 15.9 | 3.4 | 0.1 | 2.8 | 61.5 | 3.69 | 7.06 | 0.1640 | 0.0991 | |
240 | 18.3 | 3.4 | 0.1 | 2.9 | 66.9 | 4.38 | 8.82 | 0.1250 | 0.0754 | |
300 | 20.4 | 3.4 | 0.1 | 3.1 | 71.8 | 5.11 | 10.68 | 0.1000 | 0.0601 | |
400 | 23.2 | 3.4 | 0.1 | 3.3 | 78.3 | 6.24 | 13.32 | 0.0778 | 0.0470 | |
500 | 26.4 | 3.4 | 0.1 | 3.5 | 86.4 | 7.63 | 16.50 | 0.0605 | 0.0366 |
8)8.7/10(15)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable
Normal Cross Section of Conductor | Normal Diameter of Conductor | Normal Thickness of Insulation | Normal Thickness of Copper Tape |
Normal Thickness of Outer Sheath | Approx. Overall Dia. |
Approx. Net Weight | Max. D.C. Resistance of Conductor at 20ºC | ||||
Al Conductor | Cu Conductor | Al Conductor | Cu Conductor | ||||||||
mm2 | mm | mm | mm | mm | mm | kg/m | kg/m | Ω/km | Ω/km | ||
25 | 6.0 | 4.5 | 0.1 | 2.3 | 43.9 | 1.57 | 2.02 | 0.9270 | 0.7270 | ||
35 | 6.9 | 4.5 | 0.1 | 2.4 | 46.0 | 1.75 | 2.38 | 0.6680 | 0.5240 | ||
50 | 8.2 | 4.5 | 0.1 | 2.4 | 48.8 | 2.00 | 2.85 | 0.4936 | 0.3870 | ||
70 | 9.7 | 4.5 | 0.1 | 2.5 | 52.3 | 2.34 | 3.57 | 0.3420 | 0.2680 | ||
95 | 11.3 | 4.5 | 0.1 | 2.6 | 55.9 | 2.75 | 4.45 | 0.2464 | 0.1930 | ||
120 | 12.8 | 4.5 | 0.1 | 2.7 | 59.4 | 3.16 | 5.32 | 0.1955 | 0.1530 | ||
150 | 14.2 | 4.5 | 0.1 | 2.8 | 62.6 | 3.57 | 6.27 | 0.1587 | 0.1240 | ||
185 | 15.9 | 4.5 | 0.1 | 2.9 | 66.4 | 4.07 | 7.45 | 0.1271 | 0.0991 | ||
240 | 18.3 | 4.5 | 0.1 | 3.1 | 72.0 | 4.82 | 9.25 | 0.0976 | 0.0754 | ||
300 | 20.4 | 4.5 | 0.1 | 3.3 | 77.0 | 5.71 | 11.28 | 0.0778 | 0.0601 | ||
400 | 23.2 | 4.5 | 0.1 | 3.4 | 83.2 | 6.78 | 13.86 | 0.0615 | 0.0470 | ||
500 | 26.4 | 4.5 | 0.1 | 3.5 | 91.1 | 8.20 | 17.32 | 0.0487 | 0.0366 |
9)12/20(24)kV, 12.7/22(24)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable
Normal Cross Section of Conductor | Normal Diameter of Conductor | Normal Thickness of Insulation | Normal Thickness of Copper Tape |
Normal Thickness of Outer Sheath | Approx. Overall Dia. |
Approx. Net Weight | Max. D.C. Resistance of Conductor at 20ºC | ||||
Al Conductor | Cu Conductor | Al Conductor | Cu Conductor | ||||||||
mm2 | mm | mm | mm2 | mm | mm | kg/m | kg/m | Ω/km | Ω/km | ||
25 | – | ||||||||||
35 | 6.9 | 5.5 | 0.1 | 2.4 | 50.3 | 2.00 | 2.63 | 0.8680 | 0.6680 | ||
50 | 8.2 | 5.5 | 0.1 | 2.5 | 53.3 | 2.26 | 3.11 | 0.6410 | 0.4936 | ||
70 | 9.7 | 5.5 | 0.1 | 2.6 | 56.8 | 2.62 | 3.85 | 0.4430 | 0.3420 | ||
95 | 11.3 | 5.5 | 0.1 | 2.8 | 60.6 | 3.07 | 4.77 | 0.3200 | 0.2464 | ||
120 | 12.8 | 5.5 | 0.1 | 2.9 | 64.1 | 3.49 | 5.65 | 0.2530 | 0.1955 | ||
150 | 14.2 | 5.5 | 0.1 | 3.0 | 67.3 | 3.91 | 6.61 | 0.2060 | 0.1587 | ||
185 | 15.9 | 5.5 | 0.1 | 3.1 | 71.2 | 4.44 | 7.81 | 0.1640 | 0.1271 | ||
240 | 18.3 | 5.5 | 0.1 | 3.3 | 76.8 | 5.21 | 9.64 | 0.1250 | 0.0976 | ||
300 | 20.4 | 5.5 | 0.1 | 3.3 | 81.3 | 6.10 | 11.66 | 0.1000 | 0.0778 | ||
400 | 23.2 | 5.5 | 0.1 | 3.5 | 87.7 | 7.20 | 14.28 | 0.0778 | 0.0615 | ||
500 | 26.4 | 5.5 | 0.1 | 3.8 | 96.0 | 9.15 | 17.80 | 0.0605 | 0.0487 |
10)18/30(36)kV,19/33(36)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable
Normal Cross Section of Conductor | Normal Diameter of Conductor | Normal Thickness of Insulation | Normal Thickness of Copper Tape |
Normal Thickness of Outer Sheath | Approx. Overall Dia. |
Approx. Net Weight | Max. D.C. Resistance of Conductor at 20ºC | ||
Al Conductor | Cu Conductor | Al Conductor | Cu Conductor | ||||||
mm2 | mm | mm | mm | mm | mm | kg/m | kg/m | Ω/km | Ω/km |
25 | |||||||||
35 | |||||||||
50 | 8.2 | 8.0 | 0.1 | 2.9 | 64.9 | 3.02 | 3.87 | 0.6410 | 0.4936 |
70 | 9.7 | 8.0 | 0.1 | 3.0 | 68.4 | 3.42 | 4.65 | 0.4430 | 0.3420 |
95 | 11.3 | 8.0 | 0.1 | 3.1 | 72.0 | 3.89 | 5.59 | 0.3200 | 0.2464 |
120 | 12.8 | 8.0 | 0.1 | 3.3 | 75.7 | 4.39 | 6.54 | 0.2530 | 0.1955 |
150 | 14.2 | 8.0 | 0.1 | 3.3 | 78.7 | 4.85 | 7.55 | 0.2060 | 0.1587 |
185 | 15.9 | 8.0 | 0.1 | 3.4 | 82.6 | 5.42 | 8.79 | 0.1640 | 0.1271 |
240 | 18.3 | 8.0 | 0.1 | 3.5 | 88.0 | 6.22 | 10.66 | 0.1250 | 0.0976 |
300 | 20.4 | 8.0 | 0.1 | 3.7 | 92.9 | 7.20 | 12.77 | 0.1000 | 0.0778 |
400 | 23.2 | 8.0 | 0.1 | 3.9 | 99.3 | 8.38 | 15.46 | 0.0778 | 0.0615 |
500 | 26.4 | 8.0 | 0.1 | 4.2 | 107.6 | 10.15 | 18.85 | 0.0605 | 0.0487 |
Workshop:
Shipment:
Customer:
Certification:
FAQ:
1. How many years has Henan Jiapu Cable Group been in production?
Founded in October 1998 by Mr. Gu, our facility has three separate manufacturing workshops within its 100,000-sq.-ft. building. In 2012, we operates in a new 666,000 sq. foot state-of-the-art facility in Xiaodian Industry Park.,Xinxiang, Henan ,China
2. What kinds of products does Jiapu Cable manufacture?
1)Bare Conductor ,such as AAC,AAAC,ACSR,ACAR,AACSR,ACSR/AW and so on;
2)Aerial Bundled Cable (1kV-35kV ),such as Duplex,Triplex,Quadruplex Drop Wires and so on;
3)PVC Insulated (Flexible ) Wire ;
4) PVC Insulated and Sheathed (Armoured) Power Cable;
5)Low, Medium, High Voltage (1kV-220kV) XLPE Insulated (Armoured) Power Cable;
6)Welding Cable, Control Cable, Concentric Cable, Rubber Sheathed Cable and so on;
3. What kind of certifications do you have?
SABS, CE, ISO9001-2000, SGS
4.Which markets do you involve mainly in?
Our products have been exported mainly to Africa, Middle East, South-east Asia, South America,Central America,North America, Europe ,Australia, etc.
5. Which standards do you comply with when you produce the electrical wires and cables ?
We are able to produce electrical wires and cables based on GB, JB, IEC, BS, DIN, ASTM, JIS, NF, AS/NZS, CSA, etc. Meanwhile, we can design and manufacture the cables according to the samples and technical specification the customer supply.
6. What is the min.order quantity ?
It depends on the type and size of electrical wires and cables. For some small electrical wires, 100 meters can be accepted .But for the power cables with medium or high voltage, that should comply with the property of installed equipments. Anyhow,we will try our best to solve the problem and meet with the requirement If you have special request.
7. What is the production capacity per week or per month ?
For the bare conductor, we can finish 3000 tons within one month. For power cables, that depends on the type and size. The total output value per month is approx. USD3,000,000.00 for insulated aluminum cables and that is approx. USD8,000,000.00 for insulated copper cables.
8. Do you supply the customers with installation service in foreign country ?
We don’t have professional installation teams in foreign country.But if that is necessary, we will recommend our partners to cooperate with you.
We are China 33kv XLPE Insulated Unarmoured Electric Cable, Power Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Cable Products
BS Standard Tiger Aluminum Electric Wire Steel Reinforced ACSR Conductor
450/750V PVC Insulated Power Cable Used as Connecting Cables
Cable Manufacturer/Low Voltage Cable/ Armored Cable/ Control Cable/Flexible Cable
Low Voltage Unarmored Yjv Cable 0.6/1kv
Popular Electric Cable Products
Cables BT de distribution 4X25mm2 Cu Cuivre Type NYY PVC Insulated 0.6/1kV
Overhead ACSR / AAAC Conductor Aerial Bundle XLPE Insulated ABC Cable
ASTM Electrical Wire Insulated Wire Cable 4/0AWG 3/0AWG 12AWG 1/0AWG 2/0AWG
H07V-K 1cx2.5mm2 Single Core PVC Air-Conditioner Flexible Building Wire Manufacturer
AAC Conductor All Aluminium Conductor BS En50182
25mm2 IEC Standard Electric Cable Bare Stranded Conductor ACSR Conductor
Popular jpcable99 Products
High Performance Quaduplex Service Drop Wire
4mm2 Buliding Wire with Factory Price
Aluminum Conductor/ Cover Line Wire with ASTM Standard "Fig"
Buliding Wire Cables with Factory Price
8.7/10kv Copper Conductor XLPE Power Cable
Popular Power Cable Products
XLPE Insulated Armored Power Cable (YJV/YJV22/YJV32)
Yjv Power Cable XLPE Insulated PVC Jacket Copper Cable
1-35kv Aluminum Core XLPE Insulated PVC Sheathed Unarmoured Power Cable
LV PVC Power Cable Copper or Aluminum Conductor Armoured Underground Power Cable
Medium Voltage N2xsy / Na2xsy XLPE Insulation PVC Sheath Power Cable
Tags: Cable, Electric Cable, jpcable99, Power Cable