600/1000V Multi Cores Copper Conductor PVC Insulated Power Cable
600/1000V Multi Cores Copper Conductor PVC Insulated Power Cable image
Get Latest Price Request a quote
Basic Info.
Product Description
Application:
With the characteristics of stable capability,advanced technology,broad material resources,low price, good flexible and easy to lay and maintain, the PVC Insulated and Sheathed Power Cable are suitable to be laid for distribution line with A.C.50HZ and rated voltage up to 6kV.
Property:
1.The long-time permissible working temperature of cable conductive core is not more than 70 °C.
2.During short circuit (max. permanent time is not more than 5 seconds), the max temperature of cable conductor is not more than 165°C.
3.The difference level of laying cable is not restricted.When laying the cable,ambient temperature is not lower than 0°C.
4.They have good chemical stability,and properties of acid resistance,alkali resistance,salt resistance,oil resistance,solvent resistance and flame resistance.rty
5.Light weight,good bending property and easy installation and maintenance.
Specification:
Standard:
IEC,BS,VDE,AS/NZS,ICEA,JIS and so on,designing and manufacturing special power cable according to the other standards required by the customer
1)600/1000V, Single Core, Circular Compacted Al or Cu/PVC/PVC Unarmoured or Armoured Power Cable
| Cross Section of Conductor | No. of Wires | Thickness of Insulation | Unarmoured | Armoured | ||||||||
| Thickness of Sheath | Overall Dia. | jpcable99.en. Weight | Thickness of Bedding | Thickness of Al Tape | Thickness of Sheath | Overall Dia. | jpcable99.en. Weight | |||||
| Al Conductor | Cu Conductor | Al Conductor | Cu Conductor | |||||||||
| mm2 | – | mm | mm | mm | kg/km | kg/km | mm | mm | mm | mm | kg/km | kg/km |
| 1.5 | 1 | 0.8 | 1.4 | 5.8 | – | 51 | – | – | – | – | – | – |
| 2.5 | 1 | 0.8 | 1.4 | 6.2 | – | 64 | – | – | – | – | – | – |
| 4 | 1 | 1 | 1.4 | 7.1 | – | 88 | – | – | – | – | – | – |
| 6 | 7 | 1 | 1.4 | 7.8 | 78 | 114 | – | – | – | – | – | – |
| 10 | 7 | 1 | 1.4 | 8.6 | 96 | 159 | 1 | 0.5 | 1.8 | 13.4 | 234 | 295 |
| 16 | 7 | 1 | 1.4 | 9.6 | 123 | 222 | 1 | 0.5 | 1.8 | 14.4 | 274 | 370 |
| 25 | 7 | 1.2 | 1.4 | 11.2 | 172 | 328 | 1 | 0.5 | 1.8 | 16 | 344 | 496 |
| 35 | 7 | 1.2 | 1.4 | 12.2 | 209 | 428 | 1 | 0.5 | 1.8 | 17 | 393 | 606 |
| 50 | 19 | 1.4 | 1.4 | 13.9 | 271 | 565 | 1 | 0.5 | 1.8 | 18.7 | 478 | 764 |
| 70 | 19 | 1.4 | 1.5 | 15.9 | 356 | 818 | 1 | 0.5 | 1.8 | 20.5 | 582 | 1020 |
| 95 | 19 | 1.6 | 1.5 | 18 | 471 | 1041 | 1 | 0.5 | 1.8 | 22.6 | 717 | 1291 |
| 120 | 37 | 1.6 | 1.6 | 19.6 | 563 | 1307 | 1 | 0.5 | 1.8 | 24 | 822 | 1545 |
| 150 | 37 | 1.8 | 1.6 | 21.3 | 684 | 1592 | 1 | 0.5 | 1.8 | 25.4 | 952 | 1857 |
| 185 | 37 | 2 | 1.7 | 23.9 | 840 | 1985 | 1 | 0.5 | 1.8 | 27.9 | 1136 | 2236 |
| 240 | 61 | 2.2 | 1.8 | 27 | 1071 | 2533 | 1 | 0.5 | 1.9 | 31 | 1404 | 2877 |
| 300 | 61 | 2.4 | 1.9 | 29.6 | 1317 | 3162 | 1.2 | 0.5 | 2.1 | 34.3 | 1722 | 3551 |
| 400 | 61 | 2.6 | 2 | 33.2 | 1666 | 4120 | 1.2 | 0.5 | 2.2 | 37.6 | 2114 | 4488 |
| 500 | 61 | 2.8 | 2.2 | 37.5 | 2089 | 5163 | 1.2 | 0.5 | 2.3 | 42.1 | 2592 | 5683 |
| 630 | 61 | 2.8 | 2.3 | 41.2 | 2581 | 6447 | 1.4 | 0.5 | 2.4 | 46.3 | 3184 | 7060 |
2)600/1000V, Multi Cores, Sectoral Compacted Al or Cu/PVC/PVC Unarmoured Power Cable
| Number of Cores | Cross-Section of Conductor | No. Of Wires | Thickness of Insulation | Thickness of Sheath | Overall Diameter | Approx. Net Weight | |
| Al Conductor | Cu Conductor | ||||||
| – | mm2 | – | mm | mm | mm | kg/km | kg/km |
| Three Cores | 3×35 | 16 | 1.2 | 1.8 | 21.9 | 601 | 1280 |
| 3×50 | 18 | 1.4 | 1.8 | 26.5 | 829 | 1732 | |
| 3×70 | 18 | 1.4 | 1.9 | 29.2 | 1067 | 2367 | |
| 3×95 | 36 | 1.6 | 2 | 32.9 | 1409 | 2317 | |
| 3×120 | 36 | 1.6 | 2.1 | 36.2 | 1705 | 3983 | |
| 3×150 | 36 | 1.8 | 2.2 | 38.8 | 2045 | 4872 | |
| 3×185 | 36 | 2 | 2.4 | 44.8 | 2596 | 6077 | |
| 3×240 | 60 | 2.2 | 2.6 | 51.5 | 3353 | 7953 | |
| 3×300 | 60 | 2.4 | 2.7 | 54.9 | 6069 | 9820 | |
| Four Cores with Reduced Neutral | 3×35+16 | 16-7 | 1.2-1 | 1.8 | 25.5 | 764 | 1107 |
| 3×50+25 | 18-16 | 1.4-1.2 | 1.9 | 28.7 | 982 | 1410 | |
| 3×70+35 | 18-16 | 1.4-1.2 | 2.0 | 32 | 1278 | 1733 | |
| 3×95+50 | 36-18 | 1.6-1.4 | 2.2 | 37.8 | 1711 | 2656 | |
| 3×120+70 | 36-18 | 1.6-1.4 | 2.3 | 40.5 | 2065 | 3137 | |
| 3×150+70 | 36-18 | 1.8-1.4 | 2.4 | 44.8 | 2480 | 3660 | |
| 3×185+95 | 36-36 | 2-1.6 | 2.6 | 49.7 | 3086 | 4345 | |
| 3×240+120 | 60-36 | 2.2-1.6 | 2.8 | 56 | 3894 | 5441 | |
| 3×300+150 | 60-36 | 1.4-1.8 | 2.9 | 60.3 | 4834 | 6494 | |
| Four Cores | 4×25 | 16 | 1.2 | 1.8 | 22.5 | 644 | 1286 |
| 4×35 | 16 | 1.2 | 1.8 | 24.6 | 799 | 1696 | |
| 4×50 | 18 | 1.4 | 1.8 | 28.6 | 1071 | 2275 | |
| 4×70 | 18 | 1.4 | 2 | 31.6 | 1387 | 3120 | |
| 4×95 | 36 | 1.6 | 2.1 | 35.9 | 1850 | 4262 | |
| 4×120 | 36 | 1.6 | 2.2 | 38.8 | 2209 | 5247 | |
| 4×150 | 36 | 1.8 | 2.3 | 43.1 | 2714 | 6483 | |
| 4×185 | 36 | 2 | 2.5 | 48.7 | 3403 | 8045 | |
| 4×240 | 60 | 2.2 | 2.7 | 53.6 | 4290 | 10422 | |
| 4×300 | 60 | 2.4 | 2.9 | 58.8 | 5302 | 12969 | |
3)600/1000V, Multi Cores, Circular Compacted Al or Cu/PVC/PVC Unarmoured Power Cable
| Number of Cores | Cross-Section of Conductor | No. Of Wires | Thickness of Insulation | Thickness of Sheath | Overall Diameter | Approx. Net Weight | ||
| Al Conductor | Cu Conductor | |||||||
| – | mm2 | – | mm | mm | mm | kg/km | kg/km | |
| Three Cores | 3×10 | 7 | 1 | 1.8 | 16.6 | 281 | 465 | |
| 3×16 | 7 | 1 | 1.8 | 18.7 | 387 | 679 | ||
| 3×25 | 7 | 1.2 | 1.8 | 22.2 | 536 | 996 | ||
| 3×35 | 7 | 1.2 | 1.8 | 24.4 | 665 | 1311 | ||
| 3×50 | 19 | 1.4 | 1.9 | 28.1 | 863 | 1729 | ||
| 3×70 | 19 | 1.4 | 2 | 32.3 | 1153 | 2480 | ||
| 3×95 | 19 | 1.6 | 2.1 | 37.1 | 1563 | 3301 | ||
| 3×120 | 37 | 1.6 | 2.3 | 40.4 | 1850 | 4040 | ||
| 3×150 | 37 | 1.8 | 2.4 | 43.9 | 2258 | 5000 | ||
| 3×185 | 37 | 2 | 2.5 | 49.2 | 2819 | 6151 | ||
| 3×240 | 61 | 2.2 | 2.8 | 55.9 | 3577 | 8040 | ||
| 3×300 | 61 | 2.4 | 3 | 62.1 | 4413 | 9955 | ||
| 3×400 | 61 | 2.6 | 3.2 | 69.3 | 5512 | 12705 | ||
| Four Cores | 4×10 | 7 | 1 | 1.8 | 18.1 | 343 | 589 | |
| 4×16 | 7 | 1 | 1.8 | 20.5 | 487 | 874 | ||
| 4×25 | 7 | 1.2 | 1.8 | 24.3 | 677 | 1291 | ||
| 4×35 | 7 | 1.2 | 1.8 | 26.8 | 821 | 1681 | ||
| 4×50 | 19 | 1.4 | 2 | 31.2 | 1118 | 2273 | ||
| 4×70 | 19 | 1.4 | 2.1 | 35.8 | 1494 | 3264 | ||
| 4×95 | 19 | 1.6 | 2.3 | 41.2 | 1993 | 4312 | ||
| 4×120 | 37 | 1.6 | 2.4 | 44.8 | 2370 | 5291 | ||
| 4×150 | 37 | 1.8 | 2.5 | 48.7 | 2959 | 6615 | ||
| 4×185 | 37 | 2 | 2.7 | 54.7 | 3601 | 8044 | ||
| 4×240 | 61 | 2.2 | 3 | 62.1 | 4596 | 10547 | ||
| 4×300 | 61 | 2.4 | 3.2 | 69.1 | 5614 | 13004 | ||
4)600/1000V, Multi Cores, Sectoral Compacted Al or Cu/PVC/PVC Armoured Power Cable
| Cross Section of Conductor | No. of Wires | Thickness of Insulation | Thickness of Inner Sheath | Thickness of Steel Tape | No./Dia. Of Steel Wires | Thickness of Sheath | Overall Diameter | Approx. Net Weight | ||||||
| STA | SWA | |||||||||||||
| STA | SWA | STA | SWA | STA | SWA | Al Conductor | Cu Conductor | Al Conductor | Cu Conductor | |||||
| mm2 | – | mm | mm | mm | No./mm | mm | mm | mm | mm | kg/km | kg/km | kg/km | kg/km | |
| Three Cores | ||||||||||||||
| 3×35 | 16 | 1.2 | 1 | 0.2 | 38/1.6 | 1.8 | 1.9 | 24.7 | 28.2 | 912 | 1591 | 1447 | 2126 | |
| 3×50 | 18 | 1.4 | 1 | 0.2 | 46/1.6 | 1.9 | 2 | 29.3 | 32.8 | 1202 | 2105 | 1842 | 2745 | |
| 3×70 | 18 | 1.4 | 1.2 | 0.2 | 41/2.0 | 2.0 | 2.2 | 32.5 | 37.1 | 1520 | 2820 | 2475 | 3775 | |
| 3×95 | 36 | 1.6 | 1.2 | 0.5 | 46/2.0 | 2.1 | 2.3 | 36.5 | 40.8 | 2241 | 4049 | 2989 | 4797 | |
| 3×120 | 36 | 1.6 | 1.2 | 0.5 | 50/2.0 | 2.2 | 2.4 | 39.8 | 44.1 | 2617 | 4895 | 3435 | 5713 | |
| 3×150 | 36 | 1.8 | 1.2 | 0.5 | 43/2.5 | 2.3 | 2.5 | 42.4 | 47.8 | 3019 | 5846 | 4258 | 7085 | |
| 3×185 | 36 | 2 | 1.4 | 0.5 | 50/2.5 | 2.5 | 2.7 | 48.8 | 54.2 | 3783 | 7264 | 5219 | 8700 | |
| 3×240 | 60 | 2.2 | 1.6 | 0.5 | 58/2.5 | 2.8 | 2.9 | 56 | 61.3 | 4790 | 9390 | 6444 | 11044 | |
| 3×300 | 60 | 2.4 | 1.6 | 0.5 | 61/2.5 | 2.9 | 3.1 | 59.3 | 64.7 | 5594 | 11345 | 7458 | 13209 | |
| Four Cores with Reduced Neutral | ||||||||||||||
| 3×35+16 | 16-7 | 1.2-1 | 1 | 0.2 | 43/1.6 | 1.9 | 2 | 28.5 | 31.3 | 1107 | 1528 | 1705 | 2469 | |
| 3×50+25 | 18-16 | 1.4-1.2 | 1.2 | 0.2 | 40/2.0 | 2.0 | 2.1 | 32.2 | 36.1 | 1410 | 2044 | 2326 | 3388 | |
| 3×70+35 | 18-16 | 1.4-1.2 | 1.2 | 0.2 | 44/2.0 | 2.0 | 2.2 | 35.2 | 39.3 | 1733 | 2801 | 2762 | 4285 | |
| 3×95+50 | 36-18 | 1.6-1.4 | 1.2 | 0.5 | 41/2.5 | 2.3 | 2.5 | 42.5 | 46.3 | 2656 | 3820 | 3816 | 5925 | |
| 3×120+70 | 36-18 | 1.6-1.4 | 1.4 | 0.5 | 45/2.5 | 2.4 | 2.6 | 45.6 | 49.4 | 3137 | 4777 | 4391 | 7103 | |
| 3×150+70 | 36-18 | 1.8-1.4 | 1.4 | 0.5 | 49/2.5 | 2.6 | 2.7 | 49.9 | 53.6 | 3660 | 5709 | 5043 | 8272 | |
| 3×185+95 | 36-36 | 2-1.6 | 1.4 | 0.5 | 55/2.5 | 2.6 | 2.9 | 54.5 | 58.5 | 3445 | 7171 | 5902 | 9987 | |
| 3×240+120 | 60-36 | 2.2-1.6 | 1.6 | 0.5 | 62/2.5 | 2.9 | 3.1 | 61.6 | 65.3 | 5441 | 9272 | 7174 | 12552 | |
| 3×300+150 | 60-36 | 1.4-1.8 | 1.6 | 0.5 | 67/2.5 | 3.8 | 3.2 | 65.9 | 69.6 | 6494 | 11546 | 8355 | 15067 | |
| Four Cores | ||||||||||||||
| 4×25 | 16 | 1.2 | 1 | 0.2 | 38/1.6 | 1.8 | 1.9 | 25.3 | 28 | 934 | 1576 | 1450 | 2092 | |
| 4×35 | 16 | 1.2 | 1 | 0.2 | 41/1.6 | 1.8 | 1.9 | 27.4 | 30.2 | 1120 | 2017 | 1681 | 2578 | |
| 4×50 | 18 | 1.4 | 1 | 0.2 | 39/2.0 | 2 | 2.1 | 31.6 | 35.6 | 1454 | 2658 | 2336 | 3540 | |
| 4×70 | 18 | 1.4 | 1.2 | 0.5 | 43/2.0 | 2.1 | 2.2 | 36.3 | 39 | 2183 | 3916 | 2840 | 4573 | |
| 4×95 | 36 | 1.6 | 1.2 | 0.5 | 50/2.0 | 2.3 | 2.4 | 40.6 | 44.1 | 2748 | 5160 | 3545 | 5957 | |
| 4×120 | 36 | 1.6 | 1.4 | 0.5 | 42/2.5 | 2.4 | 2.5 | 43.9 | 47.2 | 3237 | 6214 | 4334 | 7372 | |
| 4×150 | 36 | 1.8 | 1.4 | 0.5 | 48/2.5 | 2.5 | 2.6 | 48.3 | 52 | 3853 | 7622 | 5148 | 8917 | |
| 4×185 | 36 | 2 | 1.6 | 0.5 | 54/2.5 | 2.7 | 2.8 | 54.3 | 57.6 | 4756 | 9323 | 6132 | 10774 | |
| 4×240 | 60 | 2.2 | 1.6 | 0.5 | 59/2.5 | 2.9 | 3 | 59.2 | 62.9 | 5774 | 11906 | 7374 | 13506 | |
| 4×300 | 60 | 2.4 | 1.6 | 0.5 | 65/2.5 | 3 | 3.2 | 64.3 | 68.1 | 6922 | 14589 | 8624 | 16291 | |
5)600/1000V, Multi Cores, Circular Compacted Al or Cu/PVC/PVC Armoured Power Cable
| Cross Section of Conductor | No. of Wires | Thickness of Insulation | Thickness of Inner Sheath | Thickness of Steel Tape | No./Dia. Of Steel Wires | Thickness of Sheath | Overall Diameter | Approx. Net Weight | |||||
| STA | SWA | ||||||||||||
| STA | SWA | STA | SWA | STA | SWA | Al Conductor | Cu Conductor | Al Conductor | Cu Conductor | ||||
| mm2 | – | mm | mm | mm | No./mm | mm | mm | mm | mm | kg/km | kg/km | kg/km | kg/km |
| Three Cores | |||||||||||||
| 3×10 | 7 | 1 | 1 | 0.2 | 35/1.25 | 1.8 | 1.8 | 19.4 | 21.5 | 494 | 679 | 988 | 1172 |
| 3×16 | 7 | 1 | 1 | 0.2 | 32/1.6 | 1.8 | 1.8 | 21.5 | 24.3 | 604 | 895 | 1051 | 1343 |
| 3×25 | 7 | 1.2 | 1 | 0.2 | 38/1.6 | 1.8 | 1.8 | 25 | 27.9 | 791 | 1252 | 1329 | 1790 |
| 3×35 | 7 | 1.2 | 1 | 0.2 | 42/1.6 | 1.8 | 1.9 | 27.2 | 30.2 | 950 | 1595 | 1551 | 2196 |
| 3×50 | 19 | 1.4 | 1.1 | 0.2 | 39/2.0 | 2 | 2.1 | 31.3 | 35.2 | 1213 | 2079 | 2128 | 2994 |
| 3×70 | 19 | 1.4 | 1.2 | 0.5 | 45/2.0 | 2.1 | 2.2 | 35.6 | 40.1 | 1567 | 2894 | 2678 | 4005 |
| 3×95 | 19 | 1.6 | 1.3 | 0.5 | 42/2.5 | 2.3 | 2.4 | 42 | 46.2 | 2449 | 4188 | 3689 | 5428 |
| 3×120 | 37 | 1.6 | 1.3 | 0.5 | 45/2.5 | 2.4 | 2.5 | 45.3 | 49.6 | 2823 | 5014 | 4174 | 6364 |
| 3×150 | 37 | 1.8 | 1.4 | 0.5 | 49/2.5 | 2.5 | 2.7 | 48.9 | 53.2 | 3327 | 6069 | 4795 | 7537 |
| 3×185 | 37 | 2 | 1.5 | 0.5 | 56/2.5 | 2.7 | 2.8 | 54.5 | 58.7 | 4038 | 7371 | 5686 | 9019 |
| 3×240 | 61 | 2.2 | 1.6 | 0.5 | 63/2.5 | 2.9 | 3.1 | 61.4 | 65.2 | 4994 | 9457 | 6862 | 11325 |
| 3×300 | 61 | 2.4 | 1.7 | 0.5 | 70/2.5 | 3.2 | 3.3 | 67.9 | 71.7 | 6022 | 11564 | 8101 | 13643 |
| 3×400 | 61 | 2.6 | 1.9 | 0.5 | 62/3.15 | 3.4 | 3.6 | 75.4 | 80.5 | 7350 | 14543 | 10535 | 17728 |
| Four Cores | |||||||||||||
| 4×10 | 7 | 1 | 1 | 0.2 | 39/1.25 | 1.8 | 1.8 | 20.9 | 23 | 552 | 798 | 1073 | 1319 |
| 4×16 | 7 | 1 | 1 | 0.2 | 35/1.6 | 1.8 | 1.8 | 23.3 | 26.1 | 723 | 1110 | 1213 | 1601 |
| 4×25 | 7 | 1.2 | 1 | 0.2 | 42/1.6 | 1.8 | 1.9 | 27.2 | 30.2 | 959 | 1573 | 1559 | 2173 |
| 4×35 | 7 | 1.2 | 1 | 0.2 | 37/2.0 | 1.9 | 2 | 29.7 | 33.6 | 1140 | 2000 | 2006 | 2866 |
| 4×50 | 19 | 1.4 | 1.2 | 0.2 | 44/2.0 | 2.1 | 2.2 | 34.6 | 38.4 | 1524 | 2679 | 2541 | 3696 |
| 4×70 | 19 | 1.4 | 1.2 | 0.5 | 50/2.0 | 2.3 | 2.3 | 40.5 | 43.7 | 2338 | 4107 | 3187 | 4956 |
| 4×95 | 19 | 1.6 | 1.2 | 0.5 | 46/2.5 | 2.4 | 2.6 | 45.9 | 50.2 | 2955 | 5274 | 4325 | 6644 |
| 4×120 | 37 | 1.6 | 1.4 | 0.5 | 51/2.5 | 2.6 | 2.7 | 50 | 54.2 | 3466 | 6387 | 4568 | 7888 |
| 4×150 | 37 | 1.8 | 1.4 | 0.5 | 55/2.5 | 2.7 | 2.8 | 53.8 | 58.1 | 4144 | 7800 | 5772 | 9428 |
| 4×185 | 37 | 2 | 1.6 | 0.5 | 62/2.5 | 2.9 | 3 | 60.2 | 64.5 | 4987 | 9430 | 6822 | 11266 |
| 4×240 | 61 | 2.2 | 1.6 | 0.5 | 70/2.5 | 3.1 | 3.3 | 67.7 | 71.5 | 6161 | 12111 | 8233 | 14184 |
| 4×300 | 61 | 2.4 | 1.6 | 0.5 | 61/3.15 | 3.4 | 3.5 | 74.7 | 78.8 | 7346 | 14735 | 10305 | 17694 |
We are China 600/1000V Multi Cores Copper Conductor PVC Insulated Power Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular 600/1000V Multi Cores Copper Conductor PVC Insulated Power Cable Products
Popular Cable Products
Aluminum or Copper Conductor XLPE Insulated Medium Voltage Concentric Neutral Cables
All Aluminum Conductor Concentric-Lay-Stranded
0.6/1kv 185mm XLPE Insulation ABC Cable
Single Core XLPE Insulated Solar Cables 4mm Solar Cable TUV En50618 Standard Solar Cable
Copper Conductor XLPE Insulated PVC Sheathed Armored Electric Power Cable
Type 41 - Flexible Trailing Cable
Popular jpcable99 Products
33kv Aluminium Core XLPE Insulated Unarmoured Power Cable
High Quality XLPE Insulated Lsoh Sheathed Power Cable
High Quality LV Copper Wire XLPE Power Cable
Nyy Power and Control Cable for Fixed Installation HD 603 DIN VDE 0276 Bs 6346
High Efficiency ACSR Bare Conductor (BS 215- PART2)
Hot Sales 15kv Overhead ABC Cable
Popular PVC Cable Products
0.6/1kv 95mm2 XLPE Insulated Underground Power Electric Wire Cable
450/750V Copper Conductor PVC Insulated Electric Wire
Medium Voltage Single Core XLPE Insulated Aluminum Conductor Underground Power Cable
H05V2V2-F, Electric Wire, 300/500 V, Flexible Cu/PVC/PVC (HD 21.5)
12/20kv XLPE Insulated PVC Sheathed Power Cable for Power Transmission
0.6/1kv Low Voltage Copper Conductor XLPE Insulated