40mva 220kv 3phase 3winding Power Transformer with on Load Tap Changer

China 
                40mva 220kv 3phase 3winding Power Transformer with on Load Tap Changer
              manufacture and supplier

40mva 220kv 3phase 3winding Power Transformer with on Load Tap Changer image

Get Latest Price Request a quote

Basic Info.

Model NO.
40MVA

Cooling Method
Oil-immersed Type Transformer

Winding Type
Customized

Certification
ISO9001-2000, ISO9001, ISO9001-2000, ISO9001, CCC

Usage
Single-phase Transformer, Rectifier Transformer, Combined Transformer, Power Transformer, Distribution Transformer, Single-Phase Transformer, Rectifier Transformer, Combined Transformer, Power Transformer, Distribution Transformer, Three Phase

Frequency Characteristics
50Hz 60Hz

Shape of Core
Ring

Brand
Ville

Test Certification
CQC Transformer Test

Voltage Range Hv
220 +-2X2.5% 242+-2X2.5% Kv

Mv
69 115 121 Kv

LV
6.3/3.3/10.2/11/35/37/38.5kv/60kv

Rated Popower Definitionwer
40000kVA

Tap Changer
Mr or Hm China

Transport Package
Wooden Cases and Main Body Nude Packing

Specification
IEC Standard

Trademark
vilLE

Origin
China

HS Code
8504231200

Production Capacity
1set/6monthes

Product Description

220KV 3PHASE 3WINDING Power Transformer with on load tap changer

Technical parameters:

Voltage: 220+ – 2×2.5% 242+-2×2.5% 
Connection group: YNyn0d11
Winding combination: H–L
No-load current(%): 0.5
No-load loss(kW): 36
On-load loss(kW): 178
lmpedance(%): step-up HV-MV 22-14 HV-LV 12-14 MV-LV 7-9 
Step down:HV-MV 12-14 HV-LV 22-14 MV-LV 7-9
Weight of active part(kg): 3 28290
Transport weight(kg): 3 35000 (filling with nitrogen)
Transport dimension (L W H mm): 3300x2480x2950
Capacity: 40000kVA

Structure characteristic:

1,Iron core
1. 1The iron core adopts cold-rolled crystal-oriented silicon steel plate 30Z140 with high quality, low-loss, and no
time effect, sheared by Geroge line and with no burr. 1.2 Iron core adopts pulling board structure, the upper
and down yoke is clamped by board, to form the frame structure. The iron core adopts advanced lamination
process, which effectively controls the no-load loss and electro-magnetic noise.

2 Winding
2.1 Winding adopts mature structure, which ensure the reliability of transformer operation.
2.2 The insulation power field intensity between turns shall be controlled no greater than 1.6kV/mm.

3,Body
3.1 Body adopts mature insulation structure, and strictly guarantee the main axial insulation margin.
3.2 Body mostly adopt multi-coil whole assembly, processed in constant voltage and evaporation, which made
coil shrink evenly and with less rebounce, and enhance the electric strength and mechanical strength.

3.3 Adopt laminating wood board or thermal shaped insulation cardboard. Pressed tightly with pin, which ensure
the winding is constantly pressed tightly. 

4,leading wire
4.1 The layout of all leading wire is reasonable, which guarantees the enough electric distance and mechanical
strenth. 

4.2 All leading wire is cirlulized ,which guarantee the reliable wild or prize connection. 

5,Oil tank
5.1 Oil tank adopts structure of flat top, bell jar type, which add the mechanical strength of oil tank and also
make the appearance beautiful and graceful, site installation tend to be more convenient.

5.2 Pipeline with gas relay such as the oil tube and bushing hoist support on top of oil tank is with hoist
gradient, to facilitate the gas in transformer flow to gas relay.

5.3 Vacuum oiling is adopted, there is no leakage and permanent distortion in the following test. vacuum-
pumping :759mmHg load voltage test: bear 2 times the oil pressure of oil conservator oil surface for 24 hours.

5.4 The structure of transformer is convenient for disassembly and change of bushing and porcelain element.
5.5 The oil drip valve is set on the bottom of oil tank, sampling valve is set in the middle.
5.6 collective gas connecting tube is fixed on the bushing hoist support.
5.7 Transformer is of full-sealed structure, the upper and down oil tanks are required to welded fully. 

6,Oil conservation tank 
6.1 Adopt capsule type, finger type oil level indicator oil conservation tank. 
6.2 The structure is convenient for internal cleaning, the capacity can ensure no oil overflow in 40 ambient
temperature with full load, and oil shall be seen from oil level indicator before put into operation in -25.

6.3 Oil conservation tank is equipped with oil-sealed moisture absorber. 

7,Safety protection device:
7.1 Gas relay is fixed in transformer, the standard complies with ZBK41004-89Gas relay.
7.2 There is enough and reliable pressure release device, and matched with oil spray pipe, the direction of oil
spraying is downward. 

8,Oil temperature measuring device:
8.1 There is pipe support of mercury thermometer, which is  set on the top of oil tank.
8.2 There is temperature controller,  the accuracy of thermometer complies with the related standard. Quantity
and technical requirement shall as per tender document. 

9,Each component  of transformer shall be prefabricated once in manufacture factory, marked, to ensure the
smooth procedure of site assembly. Before Ex-factory, inner core shall be check, and clean the fifth in
transformer.

Technical parameters:

Cooling method        
Winding Connection  OLTC Position Voltage    
(kV) Current A      
(ONAN) Current A      
(ONAF)          
HV Star  1 207 529.9 892.5
    9 230 176.9 803.3
    17 253 433.6 730.2
LV auto 9 132 831 1400
Tertiary Delta  9 20 685.5 1155
7. Vector Group YN d11
8. Impedance Voltage in Percent at 75
Power MVA winding Rated voltage kV Impedance voltage %
40 HV/LV 230/132 18
9. No-load Current: 0.2%:
10. Sustained Short Circuit Current.
Winding Max. Sustained Short-circuit Current. Ka
HV 8.5
LV 10.4
TV 19
11. Max. Duration of Short-circuits in Seconds(s)
HV: 3s
LV: 3 s
TV: 3s
12.No load current % 0.3

Structure drawing:



Packing and Shipping 


 

Packaging Details: the accessories packed in plywood cases,the main body in nude.

Our Best Service For You

1. Pre sale service
a. make technical solution
b. send quotation, technical data sheet and drawing
c. prepare power transmission plan, testing plan,and shipment plan
2. In sale service
a. supervise the manufacturing schedule totally in accordance with the plan
b. send photos to customer during every manufacturing process(hold point)
c. inform the customer one week before testinng.
3. After sale service
a. installation and commissioning, training the workers
b. quick response within 12 hours any time
c. provide 12 months gurantee period normally.

Thanks for choosing VILLE as your reliable partner and
please trust both of us will create a brilliant future!

/* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1

We are China 40mva 220kv 3phase 3winding Power Transformer with on Load Tap Changer manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular 40mva 220kv 3phase 3winding Power Transformer with on Load Tap Changer Products

  • No related articles
  • Popular cnville Products

    on-Load Tap Changer for Transformer Load Break Switch Tap Changer

    Sfsz10-8000/110 8mva 110kv Three-Winding Load Tapping Power Transformer

    S11-M-80/10 80kVA 10kv Wond Core Type Hermetically Sealed Oil Immersed Transformer/Distribution Transformer

    Dh15-M-30/20 30kVA Single Phase Pole Mounted Distribution Transformer

    Lzzbj9-7.2 Current Transfomer for Mv Switchgear, Voltage Transformer, Measurement Transformer

    Lw36-40.5 High Voltage Sf6 Post Type Outdoor Circuit Breaker

    Popular Powertransformer Products

    180mva Power Transformer with on Load Tap Changer

    50mva 220kv Power Transformer with on Load Tap Changer

    63000kVA Power Transformer 220kv

    220kv Power Transformer with on Load Tap Changer

    90mva Power Transformers with on Load Tap Changer

    150mva 220kv Power Transformer with on Load Tap Changer

    Popular Transformer Products

    125kVA 10kv Oil Immersed Three Phase Amorphous Alloy Transformer/Distribution Transformer

    Epoxy Resin Insulation Dry Type Transformer

    Sf-50000/69/6.3 50mva 66kv Double-Winding Power Transformers with off-Circuit Tap Changer

    Hjsspz-16000/35 16mva 35kv Arc Furnace Transformer

    Low Noise Traction Oil-Immersed Transformer Genious Factory Power Grid with TUV

    S13 Series Low Voltage Oil-Immersed Transformer for Subway, Railway with CNAS Certificate

    Tags: , , ,

    FAST AND RELIABLE SERVICE FOR YOUR PROJECT

    Contact our trained experts today to find your perfect power solution.

    ASK A QUESTION