8.7/10kv Copper/Aluminium Conductor XLPE Cable with PVC Outer Sheath

China 
                        8.7/10kv Copper/Aluminium Conductor XLPE Cable with PVC Outer Sheath
                      manufacture and supplier

8.7/10kv Copper/Aluminium Conductor XLPE Cable with PVC Outer Sheath image

Get Latest Price Request a quote

Quick Details

8.7/10kv Copper/Aluminium Conductor XLPE Cable with PVC Outer Sheath

power cable

Huatong

ISO9001, CE, UL, CCC, RoHS

Cable

Round Wire

XLPE

PVC

Copper/Aluminium

Underground

Stranded

Insulated

1-4

1.5-400m²

100,000m²

30 Years

ISO,CCC,Ce

Huatong

Wooden Drum / Iron Drum

1/2/3/4 cores

China

854449210

Product Details

8.7/10KV  copper/aluminium conductor xlpe  cable with PVC outer sheath
    (1)Production capacity:5000km/month
    (2)MOQ:1km
    (3)Delivery:5~15 officail days.
    (4)Standards:IEC,ASTM,DIN,BS; or according to customers’ requirements.
    (5)Delivery length: on request.

 Specification
1. Conductors: copper or aluminum.
 2. Both armored and non-armored type power cables are available.
 3. Voltage rating: 0.6/1kV 3.6/6kV 6/10kV 8.7/15kV 26/35kV.
 4. PVC or XLPE sheathed.
 5. Number of cable cores: one core (Single core),two cores(Double cores),three cores,
      Four cores (Four Equal-section-area cores or three equal-section area cores and one smaller section area neutral core),
     Five cores (Five equal-area cores or three equal-section-area cores and two smaller section area neutral cores).
  6. Standards: IEC 60502.IEC, BS, DIN, ASTM, CSA, NFC, AS, GOST etc. Or other special characteristics as customers request.

Characteristics of Cable
 1.Max Long-time operating temperature of PVC insulated cable is 70°C,XLPE 90°C
 2.Installing temperature of cable should not be less than 0°C
 3.Max short-circuit temperature is:PVC not exceed 160°C,XLPE 250°C,Not more than5 Sec.
 4.Permitting bending radius cable: Not less than 10 D times (D:external diameter of cable)
 5.Perfect chemical stability, resistant against acids, alkali, grease and organic solvents, and flamer retardant.

Number of Cores & Nominal Cross-section Area

Number of Cores 1 2 3 3+1 4 3+2 4+1 5
Section Area (mm2) 4 – 500 2.5 – 500 2.5 – 300 4 – 300 2.5 – 300 2.5 -300 4 – 300 2.5 – 95

 

Installation:

1. The installation temperature should not over 20ºC, If the ambient temperature is lower than 0ºC, the cable should be preheated.
2. The bending radius of cable should not less than 8 times.
3. After installantion, the cable should with stand voltage test for 15min. 3.5kv D.C.
 

In air:
1.  As the single core cable laying in parallel, the distance between the cable’s center is 2 times (for cables which cross section area of conductor ≤185mm2) and
90mm (for cables which cross sectional area of conductor≥240mm2)
2. Ambient temperature: 30ºC
3. Max. temperature of conductor: 70ºC
4. Rating factors of current rating for ambient temperature:

Air temperature 20ºC 25ºC 35ºC 40ºC 45ºC
Rating factors 1.12 1.06 0.94 0.87 0.79

Direct in ground:
1.  When the single core cables are installed separately, the distance between the cable’s center is 2 times of the cable diameter.
2.  Ambient temperature: 25ºC.
3.  Max. temperature of conductor: 70ºC.
4.  Soil thermour resistivity: 1.0ºC. m/w.
5.  Depth: 0.7m
6.  Rating factors under different ambient temp.:

Air temperature 15ºC 20ºC 30ºC 35ºC
Rating factors 1.11 1.05 0.94 0.88

PVC Insulation Electric Cable

TYPE Description of Cable
 
Main Applications
 
CU core AL core
VV VLV Copper/Aluminium core,PVC insulated,PVC sheathed power cable Non-armoured PVC cable are suited for laying indoors,In cable trench,On cable racks and in pipes. Unable bear external pressures and tensions.
VY VLY Copper/Aluminium core,PVC insulated,PE sheathed power cable
VV22 VLV22 Copper/Aluminium core,PVC insulated,steel tape armored,PVC sheathed power cable Steel-tape armoured PVC cables are suited for vertical burial.Can bear moderate positive pressures,Unable bear tension forces.
VV23 VLV23 Copper/Aluminium core,PVC insulated,steel tape armored,PE sheathed power cable
VV32 VLV32 Copper/Aluminium core,PVC insulated,thin steel wire armored,PVC sheathed power cable Thin steel wire armoured PVC cables are used in case of great difference of levels or vertical installation and Can do vertical burial.Can bear moderate positive pressures and tension forces.
VV33 VLV33 Copper/Aluminium core,PVC insulated,thin steel wire armored,PE sheathed power cable
VV42 VLV42 Copper/Aluminium core,PVC insulated,thick steel wire armored,PVC sheathed power cable Thick steel wire armoured PVC cables are suited for vertical installation and can be laid water or sea-bottom.Can bear greater positive pressures and tension forces.
VV43 VLV43 Copper/Aluminium core,PVC insulated,thick steel wire armored,PE sheathed power cable

 
XLPE Insulated electric cable

Type Description Application
Cu Core Al Core
YJV
ZR-YJV
YJLV
ZR-YJLV
Cu(Al)Core, XLPE Insulated, PVC Sheathed Power Cable
Cu(Al)Core, XLPE Insulated, PVC Sheathed flame- retardant Power Cable
Can be laid in indoor, outdoor, tunnels, cable channels, reinforced concrete pipelines and loose soil. Cable should not bear outer mechanic force, but can bear a certain tractional force.
YJV22
ZR-YJV22
YJLV22
ZR-YJLV22
Cu(Al)Core, XLPE Insulated, Steel Tape Armored and PVC Sheathed Power Cable
Cu(Al)Core, XLPE Insulated, Steel Tape Armored and PVC Sheathed flame- retardant Power Cable
Laid underground. Cable can bear outer mechanic force, but should not bear large tractional force.
YJV32
ZR-YJV32
YJLV32
ZR-YJLV32
Cu(Al)Core, XLPE Insulated, Steel Wire Armored and PVC Sheathed Power Cable
Cu(Al)Core, XLPE Insulated, Steel Wire Armored and PVC Sheathed flame- retardant Power Cable
Laid in indoor, tunnels and mines. Cable can bear outer mechanic force and fairly large tractional force.
YJV42
ZR-YJV42
YJLV42
ZR-YJLV42
Cu(Al)Core, XLPE Insulated, Steel Wire Armored and PVC Sheathed Power Cable
Cu(Al)Core, XLPE Insulated, Steel Wire Armored and PVC Sheathed flame- retardant Power Cable
Can be laid in vertical section, indoor, tunnels and mines. Cable can bear outer mechanic force and very large tractional force.


Your best choice → Huatong Cable Inc. 
 (1),More than 30 years experience.
 (2) ,100,000m² factory,200 staffs,annual output 100,000 metic tons.
 (3),Sound Quality Control
    –Material inspection;
    –manufacturing inspection;
    — Finished products inspection;
    — Inspection before delivery.
    –Third party inspection.
    — Inspection of storage at port of departure.
 (4),ISO Certificated.
 (5) ,Plenty of material and lobor gurantee the delivery prompt and price competitive.
 (6),24/7 service

We are China 8.7/10kv Copper/Aluminium Conductor XLPE Cable with PVC Outer Sheath manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular 12/20kv Power Cable Products

Underground Cable XLPE Insulation 12/20kv Copper and Aluminum Power Cable Price

Bare/Aluminium Conductor Medium Voltage 12/20kv XLPE Insulated Cable

Popular huatongcable Products

Al/XLPE/PVC/Swa/PVC Mv Armored Cable

8000 Series Aluminum Alloy Concentric Cable

ASTM Standard Aluminum Conductor Core XLPE Insulation PVC Sheath Bundled Cable Power Cable

Transmission and Distribution Line Overhead AAC Conductor

Electrical Transmission Line ACSR Conductor Overhead Conductor

Gsw Stranded Galvanized Steel Zinc Coated Steel Wire

Popular XLPE Insulated Cable Products

0.6/1kv 4core 240sqmm Copper Conductor XLPE Insulated PVC Sheath

IEC Standard BS Standard 0.6/1kv Cu/XLPE/Swa/PVC 4X10+6mm2, 4X16+10mm2, 4X25+16mm2, 4X35+16mm2 Swa Power Cable

Low Voltage ASTM/NFC/BS Standard Electric Cable ABC Cable

25kv Sac Spaced Aerial Cable 1core 240mm2 185mm2

Subway XLPE Insulated PVC Sheathed Copper Electric Wire Power Cable

Medium Voltage XLPE Insulated Steel Wire Armoured Power Cable.

Popular XLPE Power Cable Products

25kv XLPE Power Cable

XLPE Insulated Steel Tape Armoured Copper Power Overhead Electrical/Electric Wire Cable

18/30kv One Phase Steel Wire Armoured Electrical Armoured Power Cable Copper Wire Screen Cable

Copper Conductor 4 Core 120mm2 XLPE Insulated Armoured Power Cable

High Voltage XLPE Stranded Conductor N2xsey 26/35kv 3X95mm2 Power Cable Three Core Screened Kema / CE

XLPE Power Cable 500mm2 Crosslinked Wire and Cable

Tags: , , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION