1~35kv Outdoor Heat Shrinkable Cable Straight Joint Kits
1~35kv Outdoor Heat Shrinkable Cable Straight Joint Kits image
Get Latest Price Request a quote
- Overview
- Product Description
- Detailed Photos
- Product Parameters
- Recommended Product
- Company Profile
- Packaging & Shipping
- FAQ
Basic Info.
Packaging & Delivery
Product Description
Heat-shrinkable cable terminals
It commonly known as heat-shrinkable cable heads, are widely used on the terminals of cross-linked cables or oil-immersed cables with voltage levels of 35KV and below. Compared with the traditional cable accessories, the intermediate connection of the cable has the characteristics of small size, light weight, safety and reliability, and convenient installation.
0.6/1KV-Heat Shrinkable Cable Accessories
| Name | Item No. | Suit cables’ sectional area (sqmm) | Name | Item No. | Suit cables’ sectional area (sqmm) |
| 0.6/1kV Single Core Heat Shrinkable Termination Kits | VSZ-1/1.0 | 10~16 | 0.6/1kV Single Core Heat Shrinkable Joint | VSJ-1/1.0 | 10~16 |
| VSZ-1/1.1 | 25~50 | VSJ-1/1.1 | 25~50 | ||
| VSZ-1/1.2 | 70~120 | VSJ-1/1.2 | 70~120 | ||
| VSZ-1/1.3 | 150~240 | VSJ-1/1.3 | 150~240 | ||
| VSZ-1/1.4 | 300~400 | VSJ-1/1.4 | 300~400 | ||
| 0.6/1kV 2-cores Heat Shrinkable Termination Kits | VSZ-1/2.0 | 10~16 | 0.6/1kV 2-cores Heat Shrinkable Joint | VSJ-1/2.0 | 10~16 |
| VSZ-1/2.1 | 25~50 | VSJ-1/2.1 | 25~50 | ||
| VSZ-1/2.2 | 70~120 | VSJ-1/2.2 | 70~120 | ||
| VSZ-1/2.3 | 150~240 | VSJ-1/2.3 | 150~240 | ||
| VSZ-1/2.4 | 300~400 | VSJ-1/2.4 | 300~400 | ||
| 0.6/1kV 3-cores Heat Shrinkable Termination Kits | VSZ-1/3.0 | 10~16 | 0.6/1kV 3-cores Heat Shrinkable Joint | VSJ-1/3.0 | 10~16 |
| VSZ-1/3.1 | 25~50 | VSJ-1/3.1 | 25~50 | ||
| VSZ-1/3.2 | 70~120 | VSJ-1/3.2 | 70~120 | ||
| VSZ-1/3.3 | 150~240 | VSJ-1/3.3 | 150~240 | ||
| VSZ-1/3.4 | 300~400 | VSJ-1/3.4 | 300~400 | ||
| 0.6/1kV 4-cores Heat Shrinkable Termination Kits | VSZ-1/4.0 | 10~16 | 0.6/1kV 4-cores Heat Shrinkable Joint | VSJ-1/4.0 | 10~16 |
| VSZ-1/4.1 | 25~50 | VSJ-1/4.1 | 25~50 | ||
| VSZ-1/4.2 | 70~120 | VSJ-1/4.2 | 70~120 | ||
| VSZ-1/4.3 | 150~240 | VSJ-1/4.3 | 150~240 | ||
| VSZ-1/4.4 | 300~400 | VSJ-1/4.4 | 300~400 | ||
| 0.6/1kV 5-cores Heat Shrinkable Termination Kits | VSZ-1/5.0 | 10~16 | 0.6/1kV 5-cores Heat Shrinkable Joint | VSJ-1/5.0 | 10~16 |
| VSZ-1/5.1 | 25~50 | VSJ-1/5.1 | 25~50 | ||
| VSZ-1/5.2 | 70~120 | VSJ-1/5.2 | 70~120 | ||
| VSZ-1/5.3 | 150~240 | VSJ-1/5.3 | 150~240 | ||
| VSZ-1/5.4 | 300~400 | VSJ-1/5.4 | 300~400 | ||
| Test Project | Test Method | Test Result/Conclusion | |||
| 1min Power Frequency Voltage (wet state) | 4kV, No breakdown no flashover | No flashover and breakdown of the combined sample under 4kV, 1min wet state | |||
| Heating Cycles Voltage Test | Conductor heating to 90-95 ºC, each cycle for 8h, including heating 5h, cooling 3h, a total of three cycles | Complete three load cycle tests as required by the standard | |||
| 4H Power Frequency Voltage Test | 2.4kV, No breakdown no flashover | No flashover and breakdown of combined specimens | |||
8.7/15KV-Heat Shrinkable Cable Accessories
| Name | Item No. | Suit cables’ sectional area (sqmm) | Name | Item No. | Suit cables’ sectional area (sqmm) |
| 8.7/15kV Single Core Heat Shrinkable Indoor Termination Kits | VRSN-10/1.1 | 25~50 | 8.7/15kV 3-cores Heat Shrinkable Indoor Termination Kits | VRSN-10/3.1 | 25~50 |
| VRSN-10/1.2 | 70~120 | VRSN-10/3.2 | 70~120 | ||
| VRSN-10/1.3 | 150~240 | VRSN-10/3.3 | 150~240 | ||
| VRSN-10/1.4 | 300~400 | VRSN-10/3.4 | 300~400 | ||
| VRSN-10/1.5 | 500~630 | VRSN-10/3.5 | 500~630 | ||
| 8.7/15kV Single Core Heat Shrinkable Outdoor Termination Kits | VRSW-10/1.1 | 25~50 | 8.7/15kV 3-cores Heat Shrinkable Outdoor Termination Kits | VRSW-10/3.1 | 25~50 |
| VRSW-10/1.2 | 70~120 | VRSW-10/3.2 | 70~120 | ||
| VRSW-10/1.3 | 150~240 | VRSW-10/3.3 | 150~240 | ||
| VRSW-10/1.4 | 300~400 | VRSW-10/3.4 | 300~400 | ||
| VRSW-10/1.5 | 500~630 | VRSW-10/3.5 | 500~630 | ||
| 8.7/15kV Single Core Heat Shrinkable Joint | VRSJ-10/1.1 | 25~50 | 8.7/15kV 3-cores Heat Shrinkable Joint | VRSJ-10/3.1 | 25~50 |
| VRSJ-10/1.2 | 70~120 | VRSJ-10/3.2 | 70~120 | ||
| VRSJ-10/1.3 | 150~240 | VRSJ-10/3.3 | 150~240 | ||
| VRSJ-10/1.4 | 300~400 | VRSJ-10/3.4 | 300~400 | ||
| VRSJ-10/1.5 | 500~630 | VRSJ-10/3.5 | 500~630 | ||
| Test Project | Standard Requirements | Test Result/Conclusion | |||
| 1min Power Frequency Voltage (wet state) | 45kV, No breakdown no flashover | No flashover and breakdown of the combined sample under 45kV, 1min wet state | |||
| Partial discharge test 13kV devolution power not more than 20PC | 13kV≤20PC | A, B, C three-phase discharge capacity is 2PC under 13kV | |||
| Heating Cycles Voltage Test | Conductor heating to 90-95 ºC, each cycle for 8h, including heating 5h, cooling 3h, a total of three cycles | Complete three load cycle tests as required by the standard | |||
| Impulse Voltage Test | 105kV positive and negative polarity 10 times each, no flashover and breakdown of the combined specimen | 105kV positive and negative polarity 10 times each, no flashover and breakdown | |||
| Negative Polarity DC Voltage Test | 52kV, No breakdown no flashover | 52kV, 15min, No flashover and breakdown of combined specimens | |||
| 4H Power Frequency Voltage Test | 35kV, No breakdown no flashover | 35kV, 4h, No flashover and breakdown of combined specimens | |||
12/20KV 18/20KV-Heat Shrinkable Cable Accessories
| Name | Spec. (Single Core) | Spec. (3-cores) | Suit cables’ sectional area (sqmm) | ||||
| 12/20kV | 18/20kV | ||||||
| 12/20kV Single Core / 3-cores Heat Shrinkable Indoor Termination Kits | VRSN-20/1.1 | VRSN-20/3.1 | 35~70 | —— | |||
| VRSN-20/1.2 | VRSN-20/3.2 | 95~185 | 35~70 | ||||
| VRSN-20/1.3 | VRSN-20/3.3 | 240~400 | 95~185 | ||||
| VRSN-20/1.4 | VRSN-20/3.4 | 500~630 | 240~400 | ||||
| 12/20kV Single Core / 3-cores Heat Shrinkable Outdoor Termination Kits | VRSW-20/1.1 | VRSW-20/3.1 | 35~70 | —— | |||
| VRSW-20/1.2 | VRSW-20/3.2 | 95~185 | 35~70 | ||||
| VRSW-20/1.3 | VRSW-20/3.3 | 240~400 | 95~185 | ||||
| VRSW-20/1.4 | VRSW-20/3.4 | 500~630 | 240~400 | ||||
| 12/20kV Single Core / 3-cores Heat Shrinkable Joint | VRSJ-20/1.1 | VRSJ-20/3.1 | 35~70 | —— | |||
| VRSJ-20/1.2 | VRSJ-20/3.2 | 95~185 | 35~70 | ||||
| VRSJ-20/1.3 | VRSJ-20/3.3 | 240~400 | 95~185 | ||||
| VRSJ-20/1.4 | VRSJ-20/3.4 | 500~630 | 240~400 | ||||
| Test Project | Standard Requirements | Test Result/Conclusion | |||||
| 1min Power Frequency Voltage (wet state) | 54kV, No breakdown no flashover | No flashover and breakdown of the combined sample under 54kV, 1min wet state | |||||
| Partial discharge test 13kV devolution power not more than 20PC | 20kV≤20PC | A, B, C three-phase discharge capacity is 1pc under 20kV | |||||
| Heating Cycles Voltage Test | Conductor heating to 90-95 ºC, each cycle for 8h, including heating 5h, cooling 3h, a total of three cycles | Complete three load cycle tests as required by the standard | |||||
| Impulse Voltage Test | 125kV positive and negative polarity 10 times each, no flashover and breakdown of the combined specimen | 125kV positive and negative polarity 10 times each, no flashover and breakdown | |||||
| Negative Polarity DC Voltage Test | 156kV, No breakdown no flashover | 156kV, 15min, No flashover and breakdown of combined specimens | |||||
| 4H Power Frequency Voltage Test | 104kV, No breakdown no flashover | 104kV, 4h, No flashover and breakdown of combined specimens | |||||
26/35KV-Heat Shrinkable Cable Accessories
| Name | Item No. | Suit cables’ sectional area (sqmm) | Name | Item No. | Suit cables’ sectional area (sqmm) | |
| 26/35kV Single Core Heat Shrinkable Indoor Termination Kits | VRLN-35/1.1 | 50~95 | 26/35kV 3-cores Heat Shrinkable Indoor Termination Kits | VRLN-35/3.1 | 50~95 | |
| VRLN-35/1.2 | 120~185 | VRLN-35/3.2 | 120~185 | |||
| VRLN-35/1.3 | 240~400 | VRLN-35/3.3 | 240~400 | |||
| VRLN-35/1.4 | 500~630 | VRLN-35/3.4 | 500~630 | |||
| 26/35kV Single Core Heat Shrinkable Outdoor Termination Kits | VRLW-35/1.1 | 50~95 | 26/35kV 3-cores Heat Shrinkable Outdoor Termination Kits | VRLW-35/3.1 | 50~95 | |
| VRLW-35/1.2 | 120~185 | VRLW-35/3.2 | 120~185 | |||
| VRLW-35/1.3 | 240~400 | VRLW-35/3.3 | 240~400 | |||
| VRLW-35/1.4 | 500~630 | VRLW-35/3.4 | 500~630 | |||
| 26/35kV Single Core Heat Shrinkable Joint | VRLJ-35/1.1 | 50~95 | 26/35kV 3-cores Heat Shrinkable Joint | VRLJ-35/3.1 | 50~95 | |
| VRLJ-35/1.2 | 120~185 | VRLJ-35/3.2 | 120~185 | |||
| VRLJ-35/1.3 | 240~400 | VRLJ-35/3.3 | 240~400 | |||
| VRLJ-35/1.4 | 500~630 | VRLJ-35/3.4 | 500~630 | |||
| Test Project | Standard Requirements | Test Result/Conclusion | ||||
| 1min Power Frequency Voltage (wet state) | 105kV, No breakdown no flashover | No flashover and breakdown of the combined sample under 105kV, 1min wet state | ||||
| Partial discharge test 13kV devolution power not more than 10PC | 39kV≤10PC | A, B, C three-phase discharge capacity is 4pc under 39kV | ||||
| Heating Cycles Voltage Test | Conductor heating to 90-95 ºC, each cycle for 8h, including heating 5h, cooling 3h, a total of three cycles | Complete three load cycle tests as required by the standard | ||||
| Impulse Voltage Test | 250kV positive and negative polarity 10 times each, no flashover and breakdown of the combined specimen | 250kV positive and negative polarity 10 times each, no flashover and breakdown | ||||
| Negative Polarity DC Voltage Test | 156kV, No breakdown no flashover | 156kV, 15min, No flashover and breakdown of combined specimens | ||||
| 4H Power Frequency Voltage Test | 104kV, No breakdown no flashover | 104kV, 4h, No flashover and breakdown of combined specimens | ||||
View more products,you can click photos…
66~500kV High Voltage Cable Accessories 1~35kV Cold Shrink Cable Accessories Grounding Box
Customized Silicone Rubber Protector Heat Shrinkable Tubing Explosion Proof Box
/* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1
We are China 1~35kv Outdoor Heat Shrinkable Cable Straight Joint Kits manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular 1~35kv Outdoor Heat Shrinkable Cable Straight Joint Kits Products
Popular Heat Shrink Joint Products
20kv 3 Core Heat Shrinkable Accessories Outdoor Cable Joints
Factory Supply 1kv 4 Cores Heat Shrinkable Cable Termination Kit
Indoor and Outdoor 10kv Heat Shrinkable Cable Termination Kit
Heat Shrinkable Cable Termination Straight Through Joints Accessories
Hot Sale Cable Accessories 1kv 1~5 Cores Heat Shrink Joint Kit
20kv Cable Termination Heat Shrinkable Straight Through Joint
Popular Heat Shrink Joint Kit Products
10/15kv Indoor and Outdoor Silicone Rubber Joints
Indoor and Outdoor Silicone Rubber Cold Shrink Cable Joint Kits
Professional Manufacturer Heat Shrinkagle XLPE Cable Jointing Kits
Cold Shrink Cable Termination and Intermediate Joint
10-35kv Cold Shrink Straight Joints Cable Accessories
High Quality 35kv 3core Indoor Termination Kit Factory Direct Supply Heat Shrink Joint Kit
Popular jiuweielectric Products
Cable Accessory Vtt-15/600 Tee Cable Connector Factory Supply Cable Connectors
Various Specs Heat Shrink End Cap with Adhesive Coating
Vfsm-3 φ 20/6-55 Heat Shrinkable End Caps Sealing Caps
9V Supply Cable Insulation Flexible High Rate Electric Cold Shrinkable Tube
Heat Shrink Insulation Cable Repair Tape
10kv Cable Straight Joint Kits Heat Shrinkable Cable Termination Kits
Tags: 1~35kv Outdoor Heat Shrinkable Cable Straight Joint Kits, Heat Shrink Joint, Heat Shrink Joint Kit, jiuweielectric
