Indoor and Outdoor 10kv Heat Shrinkable Cable Termination Kit
Indoor and Outdoor 10kv Heat Shrinkable Cable Termination Kit image
Get Latest Price Request a quote
- Overview
- Product Description
- Detailed Photos
- Product Parameters
- Recommended Product
- Company Profile
- Packaging & Shipping
- FAQ
Basic Info.
Packaging & Delivery
Product Description
Heat-shrinkable cable terminals
It commonly known as heat-shrinkable cable heads, are widely used on the terminals of cross-linked cables or oil-immersed cables with voltage levels of 35KV and below. Compared with the traditional cable accessories, the intermediate connection of the cable has the characteristics of small size, light weight, safety and reliability, and convenient installation.
0.6/1KV-Heat Shrinkable Cable Accessories
| Name | Item No. | Suit cables’ sectional area (sqmm) | Name | Item No. | Suit cables’ sectional area (sqmm) |
| 0.6/1kV Single Core Heat Shrinkable Termination Kits | VSZ-1/1.0 | 10~16 | 0.6/1kV Single Core Heat Shrinkable Joint | VSJ-1/1.0 | 10~16 |
| VSZ-1/1.1 | 25~50 | VSJ-1/1.1 | 25~50 | ||
| VSZ-1/1.2 | 70~120 | VSJ-1/1.2 | 70~120 | ||
| VSZ-1/1.3 | 150~240 | VSJ-1/1.3 | 150~240 | ||
| VSZ-1/1.4 | 300~400 | VSJ-1/1.4 | 300~400 | ||
| 0.6/1kV 2-cores Heat Shrinkable Termination Kits | VSZ-1/2.0 | 10~16 | 0.6/1kV 2-cores Heat Shrinkable Joint | VSJ-1/2.0 | 10~16 |
| VSZ-1/2.1 | 25~50 | VSJ-1/2.1 | 25~50 | ||
| VSZ-1/2.2 | 70~120 | VSJ-1/2.2 | 70~120 | ||
| VSZ-1/2.3 | 150~240 | VSJ-1/2.3 | 150~240 | ||
| VSZ-1/2.4 | 300~400 | VSJ-1/2.4 | 300~400 | ||
| 0.6/1kV 3-cores Heat Shrinkable Termination Kits | VSZ-1/3.0 | 10~16 | 0.6/1kV 3-cores Heat Shrinkable Joint | VSJ-1/3.0 | 10~16 |
| VSZ-1/3.1 | 25~50 | VSJ-1/3.1 | 25~50 | ||
| VSZ-1/3.2 | 70~120 | VSJ-1/3.2 | 70~120 | ||
| VSZ-1/3.3 | 150~240 | VSJ-1/3.3 | 150~240 | ||
| VSZ-1/3.4 | 300~400 | VSJ-1/3.4 | 300~400 | ||
| 0.6/1kV 4-cores Heat Shrinkable Termination Kits | VSZ-1/4.0 | 10~16 | 0.6/1kV 4-cores Heat Shrinkable Joint | VSJ-1/4.0 | 10~16 |
| VSZ-1/4.1 | 25~50 | VSJ-1/4.1 | 25~50 | ||
| VSZ-1/4.2 | 70~120 | VSJ-1/4.2 | 70~120 | ||
| VSZ-1/4.3 | 150~240 | VSJ-1/4.3 | 150~240 | ||
| VSZ-1/4.4 | 300~400 | VSJ-1/4.4 | 300~400 | ||
| 0.6/1kV 5-cores Heat Shrinkable Termination Kits | VSZ-1/5.0 | 10~16 | 0.6/1kV 5-cores Heat Shrinkable Joint | VSJ-1/5.0 | 10~16 |
| VSZ-1/5.1 | 25~50 | VSJ-1/5.1 | 25~50 | ||
| VSZ-1/5.2 | 70~120 | VSJ-1/5.2 | 70~120 | ||
| VSZ-1/5.3 | 150~240 | VSJ-1/5.3 | 150~240 | ||
| VSZ-1/5.4 | 300~400 | VSJ-1/5.4 | 300~400 | ||
| Test Project | Test Method | Test Result/Conclusion | |||
| 1min Power Frequency Voltage (wet state) | 4kV, No breakdown no flashover | No flashover and breakdown of the combined sample under 4kV, 1min wet state | |||
| Heating Cycles Voltage Test | Conductor heating to 90-95 ºC, each cycle for 8h, including heating 5h, cooling 3h, a total of three cycles | Complete three load cycle tests as required by the standard | |||
| 4H Power Frequency Voltage Test | 2.4kV, No breakdown no flashover | No flashover and breakdown of combined specimens | |||
8.7/15KV-Heat Shrinkable Cable Accessories
| Name | Item No. | Suit cables’ sectional area (sqmm) | Name | Item No. | Suit cables’ sectional area (sqmm) |
| 8.7/15kV Single Core Heat Shrinkable Indoor Termination Kits | VRSN-10/1.1 | 25~50 | 8.7/15kV 3-cores Heat Shrinkable Indoor Termination Kits | VRSN-10/3.1 | 25~50 |
| VRSN-10/1.2 | 70~120 | VRSN-10/3.2 | 70~120 | ||
| VRSN-10/1.3 | 150~240 | VRSN-10/3.3 | 150~240 | ||
| VRSN-10/1.4 | 300~400 | VRSN-10/3.4 | 300~400 | ||
| VRSN-10/1.5 | 500~630 | VRSN-10/3.5 | 500~630 | ||
| 8.7/15kV Single Core Heat Shrinkable Outdoor Termination Kits | VRSW-10/1.1 | 25~50 | 8.7/15kV 3-cores Heat Shrinkable Outdoor Termination Kits | VRSW-10/3.1 | 25~50 |
| VRSW-10/1.2 | 70~120 | VRSW-10/3.2 | 70~120 | ||
| VRSW-10/1.3 | 150~240 | VRSW-10/3.3 | 150~240 | ||
| VRSW-10/1.4 | 300~400 | VRSW-10/3.4 | 300~400 | ||
| VRSW-10/1.5 | 500~630 | VRSW-10/3.5 | 500~630 | ||
| 8.7/15kV Single Core Heat Shrinkable Joint | VRSJ-10/1.1 | 25~50 | 8.7/15kV 3-cores Heat Shrinkable Joint | VRSJ-10/3.1 | 25~50 |
| VRSJ-10/1.2 | 70~120 | VRSJ-10/3.2 | 70~120 | ||
| VRSJ-10/1.3 | 150~240 | VRSJ-10/3.3 | 150~240 | ||
| VRSJ-10/1.4 | 300~400 | VRSJ-10/3.4 | 300~400 | ||
| VRSJ-10/1.5 | 500~630 | VRSJ-10/3.5 | 500~630 | ||
| Test Project | Standard Requirements | Test Result/Conclusion | |||
| 1min Power Frequency Voltage (wet state) | 45kV, No breakdown no flashover | No flashover and breakdown of the combined sample under 45kV, 1min wet state | |||
| Partial discharge test 13kV devolution power not more than 20PC | 13kV≤20PC | A, B, C three-phase discharge capacity is 2PC under 13kV | |||
| Heating Cycles Voltage Test | Conductor heating to 90-95 ºC, each cycle for 8h, including heating 5h, cooling 3h, a total of three cycles | Complete three load cycle tests as required by the standard | |||
| Impulse Voltage Test | 105kV positive and negative polarity 10 times each, no flashover and breakdown of the combined specimen | 105kV positive and negative polarity 10 times each, no flashover and breakdown | |||
| Negative Polarity DC Voltage Test | 52kV, No breakdown no flashover | 52kV, 15min, No flashover and breakdown of combined specimens | |||
| 4H Power Frequency Voltage Test | 35kV, No breakdown no flashover | 35kV, 4h, No flashover and breakdown of combined specimens | |||
12/20KV 18/20KV-Heat Shrinkable Cable Accessories
| Name | Spec. (Single Core) | Spec. (3-cores) | Suit cables’ sectional area (sqmm) | ||||
| 12/20kV | 18/20kV | ||||||
| 12/20kV Single Core / 3-cores Heat Shrinkable Indoor Termination Kits | VRSN-20/1.1 | VRSN-20/3.1 | 35~70 | —— | |||
| VRSN-20/1.2 | VRSN-20/3.2 | 95~185 | 35~70 | ||||
| VRSN-20/1.3 | VRSN-20/3.3 | 240~400 | 95~185 | ||||
| VRSN-20/1.4 | VRSN-20/3.4 | 500~630 | 240~400 | ||||
| 12/20kV Single Core / 3-cores Heat Shrinkable Outdoor Termination Kits | VRSW-20/1.1 | VRSW-20/3.1 | 35~70 | —— | |||
| VRSW-20/1.2 | VRSW-20/3.2 | 95~185 | 35~70 | ||||
| VRSW-20/1.3 | VRSW-20/3.3 | 240~400 | 95~185 | ||||
| VRSW-20/1.4 | VRSW-20/3.4 | 500~630 | 240~400 | ||||
| 12/20kV Single Core / 3-cores Heat Shrinkable Joint | VRSJ-20/1.1 | VRSJ-20/3.1 | 35~70 | —— | |||
| VRSJ-20/1.2 | VRSJ-20/3.2 | 95~185 | 35~70 | ||||
| VRSJ-20/1.3 | VRSJ-20/3.3 | 240~400 | 95~185 | ||||
| VRSJ-20/1.4 | VRSJ-20/3.4 | 500~630 | 240~400 | ||||
| Test Project | Standard Requirements | Test Result/Conclusion | |||||
| 1min Power Frequency Voltage (wet state) | 54kV, No breakdown no flashover | No flashover and breakdown of the combined sample under 54kV, 1min wet state | |||||
| Partial discharge test 13kV devolution power not more than 20PC | 20kV≤20PC | A, B, C three-phase discharge capacity is 1pc under 20kV | |||||
| Heating Cycles Voltage Test | Conductor heating to 90-95 ºC, each cycle for 8h, including heating 5h, cooling 3h, a total of three cycles | Complete three load cycle tests as required by the standard | |||||
| Impulse Voltage Test | 125kV positive and negative polarity 10 times each, no flashover and breakdown of the combined specimen | 125kV positive and negative polarity 10 times each, no flashover and breakdown | |||||
| Negative Polarity DC Voltage Test | 156kV, No breakdown no flashover | 156kV, 15min, No flashover and breakdown of combined specimens | |||||
| 4H Power Frequency Voltage Test | 104kV, No breakdown no flashover | 104kV, 4h, No flashover and breakdown of combined specimens | |||||
26/35KV-Heat Shrinkable Cable Accessories
| Name | Item No. | Suit cables’ sectional area (sqmm) | Name | Item No. | Suit cables’ sectional area (sqmm) | |
| 26/35kV Single Core Heat Shrinkable Indoor Termination Kits | VRLN-35/1.1 | 50~95 | 26/35kV 3-cores Heat Shrinkable Indoor Termination Kits | VRLN-35/3.1 | 50~95 | |
| VRLN-35/1.2 | 120~185 | VRLN-35/3.2 | 120~185 | |||
| VRLN-35/1.3 | 240~400 | VRLN-35/3.3 | 240~400 | |||
| VRLN-35/1.4 | 500~630 | VRLN-35/3.4 | 500~630 | |||
| 26/35kV Single Core Heat Shrinkable Outdoor Termination Kits | VRLW-35/1.1 | 50~95 | 26/35kV 3-cores Heat Shrinkable Outdoor Termination Kits | VRLW-35/3.1 | 50~95 | |
| VRLW-35/1.2 | 120~185 | VRLW-35/3.2 | 120~185 | |||
| VRLW-35/1.3 | 240~400 | VRLW-35/3.3 | 240~400 | |||
| VRLW-35/1.4 | 500~630 | VRLW-35/3.4 | 500~630 | |||
| 26/35kV Single Core Heat Shrinkable Joint | VRLJ-35/1.1 | 50~95 | 26/35kV 3-cores Heat Shrinkable Joint | VRLJ-35/3.1 | 50~95 | |
| VRLJ-35/1.2 | 120~185 | VRLJ-35/3.2 | 120~185 | |||
| VRLJ-35/1.3 | 240~400 | VRLJ-35/3.3 | 240~400 | |||
| VRLJ-35/1.4 | 500~630 | VRLJ-35/3.4 | 500~630 | |||
| Test Project | Standard Requirements | Test Result/Conclusion | ||||
| 1min Power Frequency Voltage (wet state) | 105kV, No breakdown no flashover | No flashover and breakdown of the combined sample under 105kV, 1min wet state | ||||
| Partial discharge test 13kV devolution power not more than 10PC | 39kV≤10PC | A, B, C three-phase discharge capacity is 4pc under 39kV | ||||
| Heating Cycles Voltage Test | Conductor heating to 90-95 ºC, each cycle for 8h, including heating 5h, cooling 3h, a total of three cycles | Complete three load cycle tests as required by the standard | ||||
| Impulse Voltage Test | 250kV positive and negative polarity 10 times each, no flashover and breakdown of the combined specimen | 250kV positive and negative polarity 10 times each, no flashover and breakdown | ||||
| Negative Polarity DC Voltage Test | 156kV, No breakdown no flashover | 156kV, 15min, No flashover and breakdown of combined specimens | ||||
| 4H Power Frequency Voltage Test | 104kV, No breakdown no flashover | 104kV, 4h, No flashover and breakdown of combined specimens | ||||
View more products,you can click photos…
66~500kV High Voltage Cable Accessories 1~35kV Cold Shrink Cable Accessories Grounding Box
Customized Silicone Rubber Protector Heat Shrinkable Tubing Explosion Proof Box
/* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1
We are China Indoor and Outdoor 10kv Heat Shrinkable Cable Termination Kit manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Heat Shrink Joint Products
20kv Cable Termination Heat Shrinkable Straight Through Joint
High Standard Heat Shrinkable 3-Core Cable Straight Joint Kit
Hot Sale Cable Accessories 1kv 1~5 Cores Heat Shrink Joint Kit
Factory Direct Supply 10kv Heat Shrinkable Cable Termination Kit
Professional Manufacturer Heat Shrinkagle XLPE Cable Jointing Kits
20kv 3 Core Heat Shrinkable Accessories Outdoor Cable Joints
Popular Heat Shrink Joint Kit Products
Professional Manufacturer Heat Shrink Termination Kit High Voltage Heat Shrinkable Joint Kit
Cable Accessories Heat Shrinkable Termination Kits Straight Through Cable Joints
Heat Shrinkable Termination Kits Straight Through Cable Joints
Indoor and Outdoor Intermediate Joint Termination and Joint Kits
Durable Low Voltage XLPE Cable Joint Termination Kits
Black / Red / Grey Heat Shrinkable Straight Through Cable Joints
Popular Indoor and Outdoor 10kv Heat Shrinkable Cable Termination Kit Products
Popular jiuweielectric Products
XLPE Cable Accessories Easy Installation Silicone Rubber Cold Shrink Tubing
Wrap Around Cable Repair Sleeves Heat Shrinkable Cable Repair Sleeve
Factory Direct Supply 10kv Heat Shrinkable Cable Termination Kit
Hv/Mv/LV Cable Accessories 3cores Terminal Kit Heat Shrink Termination Kit
Busbar Insulation Heat Shrink Sleeve Cable Wire Protection Polyolefin Heat Shrink Tubing
Wholesale Black Dual Wall Heat Shrink Tube Custom Heat Shrink Tube with Glue
Tags: Heat Shrink Joint, Heat Shrink Joint Kit, Indoor and Outdoor 10kv Heat Shrinkable Cable Termination Kit, jiuweielectric