Lcz-35 50-1500A Indoor High Voltage Dry Current Transformer

China 
                Lcz-35 50-1500A Indoor High Voltage Dry Current Transformer
              manufacture and supplier

Lcz-35 50-1500A Indoor High Voltage Dry Current Transformer image

Get Latest Price Request a quote

Basic Info.

Model NO.
LCZ-35

Operation Condition
Outdoor

Usage
Protection

Winding Form
Single Layer & Tightly Wound Type

Insulating Medium
Insulating Paper

Installation
Extension Type

Magnetic Circuit Structure
Combined Type

Voltage Transformation Principle
Photoelectric Type

Defense
Secure

Transport Package
Material Flow

Specification
50-1500A

Trademark
CNKC

Origin
China

Production Capacity
5000pieces/Year

Packaging & Delivery

Package Size
42.00cm * 27.00cm * 56.00cm

Package Gross Weight
30.000kg

Product Description

Product Description

LCZ-35 current transformer is a semi-closed insulation casting product, suitable for power system with rated frequency of 50Hz or 60Hz and rated voltage of 35kV and below, as electric energy measurement, current measurement and relay protection. This product complies with IEC44-1 and GB1208 “Current Transformer”.

Model Description

Technical parameters and structure dimensions

1. The rated secondary current, accuracy class combination, rated output and dynamic and thermal stable current are shown in the table

2. Rated insulation level: 40.5/95/185 Kv
4. The partial discharge level of the product meets the requirements of the GB1208 “Current Transformer” standard.
5. Pollution level: the products in all working conditions meet the requirements of level II pollution.
6. Non-standard products can be customized according to users.

 

Product features and scope of use

This type of current transformer is of epoxy resin casting semi-enclosed structure. The primary winding and the secondary winding are first cast into one, and then the iron core is inserted into the casting body. The product has excellent insulating properties and moisture resistance. There are grounding bolts and nameplates and four mounting holes for installation on the bottom plate of the product.
normal use conditions:
Installation place: indoors.
Ambient temperature: the temperature is 40ºC; the temperature is -5ºC; the daily average temperature does not exceed 30ºC.
Atmospheric conditions: There is no serious pollution in the atmosphere.

Product Instructions:
1) LCZ-35(Q) The wiring of the LCZ-35 current transformer current transformer should follow the series principle: that is, the primary winding should be connected in series with the circuit under test, and the secondary winding should be connected in series with all instrument loads
2) Select the appropriate change according to the measured current, otherwise the error will increase. At the same time, one end of the secondary side must be grounded to prevent the high voltage on the primary side from entering the secondary low voltage side once the insulation is damaged, causing personal and equipment accidents
3) The secondary side is absolutely not allowed to open circuit, because once the circuit is open, the primary side current I1 will all become magnetizing current, causing φm and E2 to increase sharply, resulting in excessive saturation magnetization of the iron core, serious heat generation and even burning of the coil; , which increases the error. When the current transformer is working normally, the secondary side is similar to a short circuit. If it is suddenly opened, the excitation electromotive force will suddenly change from a small value to a large value, and the magnetic flux in the iron core will show a severely saturated flat top. Therefore, the secondary winding will induce a very high peak wave when the magnetic passes through zero, and its value can reach thousands or even tens of thousands of volts, which endangers the safety of the staff and the insulation performance of the instrument. In addition, the open circuit of the secondary side makes the voltage of the second ary side reach several hundreds of volts, which will cause an electric shock accident if touched. Therefore, the secondary side of the current transformer is equipped with a short-circuit switch to prevent the secondary side from being open. In the process of use, once the secondary side is open, the circuit load should be removed immediately, and then the power outage should be processed. It can be reused after everything is disposed of.
4) In order to meet the needs of measuring instruments, relay protection, circuit breaker failure judgment and fault filtering, etc., all circuits are installed in generators, transformers, outgoing lines, bus sectional circuit breakers, bus circuit breakers, bypass circuit breakers and other circuits. 2 to 8 current transformers with secondary windings.
5) The installation site of the protective current transformer should be set as far as possible to eliminate the non-protection zone of the main protection device. For example: if there are two sets of current transformers, and the location allows, they should be located on both sides of the circuit breaker, so that the circuit breaker is in the cross protection range
6) In order to prevent the busbar failure caused by the bushing flashover of the pillar-type current transformer, the current transformer is usually arranged on the outgoing line or the transformer side of the circuit breaker.
7) In order to reduce the damage caused by the internal fault of the generator, the current transformer used for the automatic adjustment of the excitation device should be arranged on the outgoing side of the stator winding of the generator. In order to facilitate analysis and find internal faults before the generator is integrated into the system, the current transformer used for measuring instruments should be installed on the neutral side of the generator.

Product details

Products real shot

A corner of the production workshop

Product packaging

Product application case

 

 
/* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1

We are China Lcz-35 50-1500A Indoor High Voltage Dry Current Transformer manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular cnkcele Products

L/LV 18-51mm 100-600kn Electric Power Link Fittings Stay Wire Adjustment Connecting Yoke Plate of Overhead Line

Ca/CS/Es/PS Series 1kv 15-22kn Exit Type Aluminium Alloy Fixing Hook Bracket of Overhead Cable

Kyn61 40.5kv 1250A 1600A 2000A Armoured Removable High Voltage Switchgear Complete Set

Zn7 1140V 400A Mine Explosion-Proof Low-Voltage AC Vacuum Circuit Breaker

Fsp 35/66/110/220kv Composite Insulator for High Voltage Transmission Line

Ws 18-32mm Socket Clevis Link Fitting Electric Power Fittings

Popular Lcz-35 50-1500A Indoor High Voltage Dry Current Transformer Products

Lcz-35 50-1500A Indoor High Voltage Dry Current Transformer

Popular Outdoor Oil Immersed High Voltage Transformer Products

Lxk-80/100/120 Aperture 10/35kv Indoor Hv Zero-Sequence Current Transformer Opening

Jdj2 35kv 35000/100V 0.2/6p 80-500va Outdoor Hv Oil-Immersed Insulation Voltage Transformer

Jls 3/6/10kv 5A Outdoor Oil-Immersed High-Voltage Power Metering Box Three-Phase Three-Wire Combined Transformer

Jdzx9-35kv 30/150/300va Switchgear Electric Energy Metering Cabinet Single-Phase Dry-Type Voltage Transformer

Jdjj2 35kv 35000/√ 3V 0.5/6p Outdoor High Voltage Oil Immersed Voltage Transformer

Jlszy3-20 20000/100V 5-200/5A Outdoor Dry Type High Voltage Power Combined Transformer

Popular Single-Phase Oil-Immersed Transformer Products

Jszwk-10kv 10000√ 3/100√ 3/100V Outdoor Anti-Resonance Three-Phase Dry-Type Voltage Transformer

Jdz10 3/6/10kv PT Voltage Transformer for Complete Set of Switchgear

Jlszw 10kv 5-1000A 10-80ka Outdoor Stainless Steel Combined Transformer Dry Inverted Power Metering Box

Jlszv 35kv 2.5-300A Outdoor Three-Phase Three-Wire High-Voltage Metering Box Dry-Type Wide-Load Combined Transformer

Jlszy-10kv 5-1000A 10va Outdoor Three-Phase Four-Wire Combined Transformer High Voltage Power Metering Box

Jls-35kv/100V 5-300A 30/50va 10/20va Outdoor Oil-Immersed Combination Transformer High Voltage Power Metering Box

Tags: , , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION