100kVA 20kv 0.4kv Earthing Transformer Grounding Transformers
100kVA 20kv 0.4kv Earthing Transformer Grounding Transformers image
Get Latest Price Request a quote
Basic Info.
Product Description
Grounding Transformers are designed to provide an artificial, neutral point for ungrounded three phase power systems.
During the line-to-ground faults, grounding transformers provide an easy path to ground faults, thus limit the fault currents and transient over-voltages.
Grounding transformers normally carry short-circuit ground current until the circuit breaker clears the fault. Therefore, they have short time ratings.
The kVA rating of a earthing transformer depends on the normal line-to-neutral voltage and the fault current value for a specified time, such as seconds to minutes.
| Voltage | Up to 22kV |
| Operating Voltage | 20kV |
| Standard | IEC 60076-6 or Equivalent |
| Rated Neutral current | |
| Power rating | 100kVA |
| Voltage Rating HV/LV | 20/0.4kV |
| Cooling methods | ONAN |
| Frequency | 50 Hz |
| Installation | Outdoor |
| Zero sequence impedance | 19 Ohm |
| No phase | 3 |
| Voltage regulation range (No of Taps) | 5 |
| Temperature rise for the windings | As per IEC standard |
| Winding material | Copper |
| Insulation level | According to the rated voltage (IEC70076-3) |
| Impedance Voltage | 5.5 % |
| Ambient temperature | -40 to +40 °C, other temperatures on request |
| Vector group | ZNyn11 |
| Voltage regulation Range (No.of Taps) | 5 |
| Bushing | porcelain |
| Creepage | 31mm/kV |
| Breather | Silica gel |
Please take a brief moment and use the “Check List” below to gather the following (13) basic pieces of Grounding Transformer information:
- Winding configuration; either Zig Zag or Two Winding.
- Voltage(s) and BIL; The line-to-line value of the system to which the grounding transformer is to be connected. If a two winding grounding transformer is required, the secondary voltage must be provided as well.
- Continuous neutral current.
- System available neutral fault current and duration; example 500 amps for 10 seconds, 4000 amps for 2 seconds.
- Zero Sequence impedance percentage.
- Per phase impedance in Ohms.
- Per phase resistance in Ohms.
- X/R ratio; typically a value > 4.0.
- Special application conditions; i.e. 2000 MASL, etc.
- Enclosure construction or NEMA designation preference; i.e. high security compartmentalized padmounted, standard ventilated or substation design, special paint color, etc.
- Terminal connectivity preference; i.e. dead front, live front, conventional terminals, etc.
- Winding material; CU if not specified.
- Transformer temperature rise; 150° C if not specified.
Sales team:
Our advantages:
Quality Assurance
–From the very beginning, VILLE ensures quality in every step to achieve the best quality.
Experience Sharing
–With more than 30 years’ experience in power industry, VILLE brings you an optimized solution.
Global Service
–Wherever you are, VILLE global network will support and provide you with value.
Quick Response
–In response to your needs without delay, VILLE knows the value of your time.
Thanks for choosing VILLE as your reliable partner and
please trust both of us will create a brilliant future!
/* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1
We are China 100kVA 20kv 0.4kv Earthing Transformer Grounding Transformers manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular 100kVA 20kv 0.4kv Earthing Transformer Grounding Transformers Products
Popular cnville Products
Xhxy01 5 Strand Billet Continuous Casting Machine CCM
High Quality Oil Drain Nitrogen Filling Fire-Extinguishing Device for Transformer
Lw3-12 I. II Sf6 Hv Outdoor Circuit Breaker 12kv
Popular Earthing Transformer Products
200kVA 33/0.4kv Grounding Earthing Transformer Auxiliary Transformer
2mva 10kv Wond Core Type Hermetically Sealed Oil Immersed Transformer Earthing Transformer
160kVA Earthing Transformer Customized 30kv 0.4kv