Aluminum Alloy AAAC Conductor AAAC 100mm2
Aluminum Alloy AAAC Conductor AAAC 100mm2 image
Get Latest Price Request a quote
Quick Details
Product Details
1. Application
AAAC Conductor is used as bare overhead conductor for primary and secondary distribution. Designed utilizing a high-strength aluminum-alloy to achieve a high strength-to-weight ratio; affords good sag characteristics.
1). AAAC conductors are extensively used for overhead distribution and transmission lines adjacent to ocean coastlines where there can be a problem of corrosion in the steel of an ACSR construction.
2). The aluminum alloy conductors are used in replace of single-layer ACSR conductors to reduce power loss in overhead distribution and transmission lines, when replacing the aluminum conductor steel reinforced, the AAAC can save 5-8% of the construction cost.
3). AAAC referred to have higher strength but lower conductivity than pure aluminum being lighter, alloy conductors can sometimes be used to advantage in replace of the more conventional ACSR.2. Standard
2. Standard
ASTM B399, BS EN 50183, BS 3234, DIN 48201, IEC 61089, and ect.
3. Specification
AAAC Conductor according to ASTM B399
| Code Name | Area | Size & Stranding of ACSR with Equal Diameter | No. & Diameter of wires | Overall Diameter | Weight | Nominal Breaking Load | ||
| Nominal | Actual | |||||||
| MCM | mm2 | AWG or MCM | Al/Steel | mm | mm | kg/km | kN | |
| Akron | 30.58 | 15.48 | 6 | 6/1 | 7/1.68 | 5.04 | 42.7 | 4.92 |
| Alton | 48.69 | 24.71 | 4 | 6/1 | 7/2.12 | 6.35 | 68.0 | 7.84 |
| Ames | 77.47 | 39.22 | 2 | 6/1 | 7/2.67 | 8.02 | 108 | 12.45 |
| Azusa | 123.3 | 62.38 | 1/0 | 6/1 | 7/3.37 | 10.11 | 172 | 18.97 |
| Anaheim | 155.4 | 78.65 | 2/0 | 6/1 | 7/3.78 | 11.35 | 217 | 23.93 |
| Amherst | 195.7 | 99.22 | 3/0 | 6/1 | 7/4.25 | 12.75 | 273 | 30.18 |
| Alliance | 246.9 | 125.1 | 4/0 | 6/1 | 7/4.77 | 14.31 | 345 | 38.05 |
| Butte | 312.8 | 158.6 | 266.8 | 26/7 | 19/3.26 | 16.30 | 437 | 48.76 |
| Canton | 394.5 | 199.9 | 336.4 | 26/7 | 19/3.66 | 18.30 | 551 | 58.91 |
| Cairo | 465.4 | 235.8 | 397.5 | 26/7 | 19/3.98 | 19.88 | 650 | 69.48 |
| Darien | 559.5 | 283.5 | 477.0 | 26/7 | 19/4.36 | 21.79 | 781 | 83.52 |
| Elgin | 652.4 | 330.6 | 556.5 | 26/7 | 19/4.71 | 23.54 | 911 | 97.42 |
| Flint | 740.8 | 375.3 | 636.0 | 26/7 | 37/3.59 | 25.16 | 1035 | 108.21 |
| Greely | 927.2 | 469.8 | 795.0 | 26/7 | 37/4.02 | 28.14 | 1295 | 135.47 |
AAAC Conductor according to DIN 48201
| Code number | Calculated area | Number of wires | Diameter of wire | Overall diameter of conductor | Linear mass | Rated tensile strength | Max. DC resistance at 20ºC |
| mm2 | mm2 | mm | mm | kg/km | daN | Ω/km | |
| 16 | 15.89 | 7 | 1.70 | 5.1 | 43 | 444 | 2.0910 |
| 25 | 24.25 | 7 | 2.10 | 6.3 | 66 | 677 | 1.3703 |
| 35 | 34.36 | 7 | 2.50 | 7.5 | 94 | 960 | 0.9669 |
| 50 | 49.48 | 7 | 3.00 | 9.0 | 135 | 1382 | 0.6714 |
| 50 | 48.35 | 19 | 1.80 | 9.0 | 133 | 1350 | 0.6905 |
| 70 | 65.81 | 19 | 2.10 | 10.5 | 181 | 1838 | 0.5073 |
| 95 | 93.27 | 19 | 2.50 | 12.5 | 256 | 2605 | 0.3579 |
| 120 | 116.99 | 19 | 2.80 | 14.0 | 322 | 3268 | 0.2854 |
| 150 | 147.11 | 37 | 2.25 | 15.8 | 406 | 4109 | 0.2274 |
| 185 | 181.62 | 37 | 2.50 | 17.5 | 500 | 5073 | 0.1842 |
| 240 | 242.54 | 61 | 2.25 | 20.3 | 670 | 6774 | 0.1383 |
| 300 | 299.43 | 61 | 2.50 | 22.5 | 827 | 8363 | 0.1120 |
| 400 | 400.14 | 61 | 2.89 | 26.0 | 1104 | 11176 | 0.0838 |
| 500 | 499.63 | 61 | 3.23 | 29.1 | 1379 | 13960 | 0.06709 |
| 625 | 626.20 | 91 | 2.96 | 32.6 | 1732 | 17490 | 0.0540 |
| 800 | 802.09 | 91 | 3.35 | 36.9 | 2218 | 22402 | 0.0418 |
| 1000 | 999.71 | 91 | 3.74 | 41.1 | 2767 | 27922 | 0.0335 |
AAAC Conductor according to EN50183
| Code Name | Calculated Cross Section |
No..Dia.of Wires | Overall Diameter | Weight | Rated Strength |
| mm² | No./mm | mm | kg/km | kN | |
| Box | 18.8 | 7/1.85 | 5.55 | 51.4 | 5.55 |
| Acacia | 23.8 | 7/2.08 | 6.24 | 64.9 | 7.02 |
| Almond | 30.1 | 7/2.34 | 7.02 | 82.2 | 8.88 |
| Cedar | 35.5 | 7/2.54 | 7.62 | 96.8 | 10.46 |
| Deodar | 42.2 | 7/2.77 | 8.31 | 115.2 | 12.44 |
| Fir | 47.8 | 7/2.95 | 8.85 | 130.6 | 14.11 |
| Hazel | 59.9 | 7/3.30 | 9.90 | 163.4 | 17.66 |
| Pine | 71.6 | 7/3.61 | 10.8 | 195.6 | 21.14 |
| Holly | 84.1 | 7/3.91 | 11.7 | 229.5 | 24.79 |
| Willow | 89.7 | 7/4.04 | 12.1 | 245,0 | 26.47 |
| Oak | 118.9 | 7/4.65 | 14.0 | 324.5 | 35.07 |
| Mulberry | 150.9 | 19/3.18 | 15.9 | 414.3 | 44.52 |
| Ash | 180.7 | 19/3.48 | 17.4 | 496.1 | 53.31 |
| Elm | 211.0 | 19/3.76 | 18.8 | 579.2 | 62.24 |
| Poplar | 239.4 | 37/2.87 | 20.1 | 659.4 | 70.61 |
| Sycamore | 303.2 | 37/3.23 | 22.6 | 835.2 | 89.40 |
| Upas | 362.1 | 37/3.53 | 24.7 | 997.5 | 106.82 |
| Yew | 479.0 | 37/4.06 | 28.4 | 1319.6 | 141.31 |
| Totara | 498.1 | 37/4.14 | 29.0 | 1372.1 | 146.93 |
| Rubus | 586.9 | 61/3.50 | 31.5 | 1622.0 | 173.13 |
| Sorbus | 659.4 | 61/3.71 | 33.4 | 1822.5 | 194.53 |
| Araucaria | 821.1 | 61/4.14 | 37.3 | 2269.4 | 242.24 |
| Redwood | 996.2 | 61/4.56 | 41.0 | 2753.2 | 293.88 |
AAAC Conductor according to IEC61089
| Code Number | A2 Conductor | A3 Conductor | Max.D.C. Resistance of Conductor at 20ºC | ||||||||
| Number of Wires | Diameter of Wires | Diameter of Conductor | Approx. Weight | Rated Strength | Number of Wires | Diameter of Wires | Diameter of Conductor | Approx. Weight | Rated Strength | ||
| mm² | – | mm | mm | kg/km | daN | – | mm | mm | kg/km | daN | Ω/km |
| 16 | 7 | 1.83 | 5.49 | 50.4 | 5.43 | 7 | 1.84 | 5.52 | 50.8 | 6.04 | 1.7896 |
| 25 | 7 | 2.29 | 6.87 | 78.7 | 8.49 | 7 | 2.30 | 6.9 | 79.5 | 9.44 | 1.1453 |
| 40 | 7 | 2.89 | 8.67 | 125.9 | 13.58 | 7 | 2.91 | 8.73 | 127.1 | 15.1 | 0.7158 |
| 63 | 7 | 3.63 | 10.8 | 198.3 | 21.39 | 7 | 3.65 | 10.95 | 200.2 | 23.06 | 0.4545 |
| 100 | 19 | 2.78 | 13.9 | 316.3 | 33.95 | 19 | 2.79 | 13.95 | 319.3 | 37.76 | 0.2877 |
| 125 | 19 | 3.10 | 15.5 | 395.4 | 42.44 | 19 | 3.12 | 15.6 | 399.2 | 47.20 | 0.2302 |
| 160 | 19 | 3.51 | 17.55 | 506.1 | 54.32 | 19 | 3.53 | 17.65 | 511.0 | 58.56 | 0.1798 |
| 200 | 19 | 3.93 | 19.65 | 623.7 | 67.91 | 19 | 3.95 | 19.75 | 638.7 | 73.20 | 0.1439 |
| 250 | 19 | 4.39 | 21.95 | 790.8 | 84.68 | 19 | 4.41 | 22.05 | 798.4 | 91.50 | 0.1151 |
| 315 | 37 | 3.53 | 24.71 | 998.9 | 106.95 | 37 | 3.55 | 24.85 | 1008.4 | 115.29 | 0.0916 |
| 400 | 37 | 3.98 | 27.86 | 1268.4 | 135.81 | 37 | 4.0 | 28 | 1280.5 | 146.4o | 0.0721 |
| 450 | 37 | 4.22 | 29.54 | 1426.9 | 152.79 | 37 | 4.24 | 29.68 | 1440.5 | 164.70 | 0.0641 |
| 500 | 37 | 4.45 | 31.15 | 1585.5 | 169.76 | 37 | 4.47 | 31.29 | 1600.6 | 183.oo | 0.0577 |
| 560 | 61 | 3.67 | 33.03 | 1778.4 | 190.14 | 61 | 3.69 | 33.21 | 1795.3 | 204.95 | 0.0516 |
| 630 | 61 | 3.89 | 35.01 | 2000.7 | 213.90 | 61 | 3.91 | 35.19 | 2019.8 | 230.58 | 0.0458 |
| 710 | 61 | 4.13 | 37.17 | 2254.8 | 241.07 | 61 | 4.15 | 37.35 | 2276.2 | 259.86 | 0.0407 |
| 800 | 61 | 4.38 | 39.42 | 2540.6 | 271.62 | 61 | 4.4 | 39.6 | 2564.8 | 282.80 | 0.0361 |
| 900 | 91 | 3.81 | 41.91 | 2861.1 | 305.58 | 91 | 3.83 | 42.13 | 2888.3 | 329.40 | 0.0321 |
| 1000 | 91 | 4.01 | 44.11 | 3179.0 | 339.53 | 91 | 4.03 | 44.33 | 3209.3 | 366.00 | 0.0289 |
| 1120 | 91 | 4.25 | 46.75 | 3560.5 | 380.27 | 91 | 4.27 | 46.97 | 3594.4 | 409.92 | 0 0258 |
| 1250 | 91 | 4.49 | 49.39 | 3973.7 | 424.41 | – | – | – | – | ||
4. Package
Packaged by standard wooden drum, steel-wooden drum, and steel drum.
We are China Aluminum Alloy AAAC Conductor AAAC 100mm2 manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular AAAC 100mm2 Products
Aluminum Alloy Wasp Conductor AAAC 100mm2
BS Standard Oak 100mm2 AAAC All Aluminum Alloy Conductor
Popular yifangcable Products
120sqmm 150mm2 Yjv PVC XLPE Power Cable Customized Wholesale
AS/NZS 1429 19/33 (36KV) Cable
Electronical Wire, Soild Core PVC Sheath PVC Insulation 3*2.5mm2
Heavy Duty 7/8 4/8 Galvanized Steel Wire-Guy Wire
33kv Aluminum Conductor Underground Power Cable. Single Core or Three Core
Popular Products
BS Standard Oak 100mm2 AAAC All Aluminum Alloy Conductor
Aluminum Alloy Wasp Conductor AAAC 100mm2
Popular Products
Single Core Copper Cable / LV Power Cable 1kv Power Cable 16 mm2
Price of PVC Insulated Building Electric Wire 4mm 15mm 16mm 25mm
Na2xy 0.6/1 Kv Aluminum Conductor, XLPE Insulated, PVC Sheath
Yjv Yjlv 0.6/1kv Copper/Aluminum Core XLPE Insulated Steel Wire Armoured (SWA) Power Cable
XLPE Insulated Medium Voltage Concentric Neutral Cables
Tags: AAAC 100mm2, yifangcable