600/1000V ABC Aerial Bundled Cables to IEC 60502 & Tnb Specification (AL/PE)
600/1000V ABC Aerial Bundled Cables to IEC 60502 & Tnb Specification (AL/PE) image
Get Latest Price Request a quote
Quick Details
Product Details
600/1000V ABC Aerial Bundled Cables to IEC 60502 & TNB Specification (AL/PE)
Application
The aerial bundled cables designed for overhead distribution lines have an insulated neutral messenger made of AAAC, which the insulation aluminium phase conductors are helically wound over it. Can be used for fixed installation as overhead power lines up to 1000 V incl.
Standard
- TNB Specification
- IEC 60502
Construction
| Phase Conductor | H68 condition aluminium conductor, round stranded compressed. |
|---|---|
| Neutral or Messenger Conductor | Alloy aluminium conductor, round stranded compressed. |
| Street Lighting Conductor | H68 condition aluminium conductor, round stranded compressed. |
| Insulation | PE. |
| Assembly | The cable consists of insulated phase and street lighting aluminium conductors, shall be held firmly onto the insulated neutral messenger aluminium alloy conductor in a right hand (Z) lay. |
Dimensions
| Number of cores x nominal cross section | min. breaking load of conductor strand | Current rating in the air | Outer diameter | Total weight |
|---|---|---|---|---|
| mm^2 | kN | A | mm | kg/km |
| 1×16+1x 25 RM | 6.4 | 61 | 15.3 | 160 |
| 3×16+1x 25 RM | 6.4 | 61 | 19.0 | 290 |
| 3×25+1x 25 RM | 6.4 | 84 | 23.2 | 400 |
| 3×35+1x 25 RM | 6.4 | 104 | 25.6 | 500 |
| 3×50+1x 35 RM | 8.9 | 129 | 30.0 | 680 |
| 3×70+1x 50 RM | 12.1 | 167 | 34.9 | 920 |
| 3×95+1x 70 RM | 18.0 | 209 | 40.6 | 1270 |
| 3×120+1x 70 RM | 18.0 | 246 | 44.1 | 1510 |
| 3×150+1x 95 RM | 24.2 | 283 | 49.2 | 1870 |
| 3×185+1×120 RM | 30.8 | 332 | 54.9 | 2340 |
| 3×25+1×25+1×16 RM | 6.4 | 84 | 23.2 | 470 |
| 3×35+1×25+1×16 RM | 6.4 | 104 | 25.6 | 560 |
| 3×50+1×35+1×16 RM | 8.9 | 129 | 30.0 | 740 |
| 3×70+1×50+1×16 RM | 12.1 | 167 | 34.9 | 980 |
| 3×95+1×70+1×16 RM | 18.0 | 209 | 40.6 | 1330 |
| 3×120+1×70+1×16 RM | 18.0 | 246 | 44.1 | 1580 |
| 3×150+1×95+1×16 RM | 24.2 | 283 | 49.2 | 1940 |
| 3×185+1×120+1×16 RM | 30.8 | 332 | 54.9 | 2410 |
We are China 600/1000V ABC Aerial Bundled Cables to IEC 60502 & Tnb Specification (AL/PE) manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular ABC Cable Products
ABC Cable Aerial Bundled Conductor Alluminum Cable 25mm2
Aerial Bundled Conductor ABC Overhead Cable
Overhead Insulated Wire Cable Aluminum Core Service Drop
NFC 33-209 ABC Aerial Bundled Cables for Overhead Power Lines
Triplex ABC Cable 0.6/1kv (2X95+95mm2)
Outdoor ISO Service Drop Cable PE/PVC/XLPE Insulated Aluminum Condcutor Triplex Service Drop Cable
Popular Aerial Bundled Cables Products
600/1000V ABC Aerial Bundled Cables to BS 7870-5 (AL/XLPE)
600/1000V ABC Aerial Bundled Cables to AS/NZS 3560.1 (AL/XLPE)
NFC 33-209 ABC Aerial Bundled Cables for Overhead Power Lines
600/1000V ABC Aerial Bundled Cables to HD 626 S1 (AL/XLPE)
ABC XLPE Insulated, Aerial Bundled Cables
NFC 33-209 ABC Aerial Bundled Cables for Overhead Power Lines
Popular Cables to IEC 60502 Al/PE Products
Popular yifangcable Products
33kv 3c 185mm2 240mm2 300mm2 Al Conductor XLPE Insulated Power Cable
High Voltage and Medium Voltage Rubber Cable
Price of PVC Insulated Building Electric Wire 4mm 15mm 16mm 25mm
H05vvh6-F/ H07vvh6-F PVC Flat Elevator Cable
Tags: ABC Cable, Aerial Bundled Cables, Cables to IEC 60502 Al/PE, yifangcable