Power Distribution Aerial Isolated ABC Cable
Power Distribution Aerial Isolated ABC Cable image
Get Latest Price Request a quote
Quick Details
Product Details
Aluminium Conductors. Polythylene or Crosslinked Polyethylene Insulation.
ABC Cables Applications:
Used to supply 3 phase power, usually from a pole-mounted transformer, to the user’s service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for crosslinked polyethylene (XLP) insulated conductors.
ABC Cables Construction:
Conductors are concentrically stranded, compressed 1350-H19 aluminum. Insulated with either polyethylene or XLP crosslinked polyethylene. Neutral messengers are concentrically stranded 6201, AAC, or ACSR.One conductor is manufactured with an extruded ridge for phase identification.
ABC Cables Standards:
1.B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
2.B-231 Aluminum conductors, Concentric-Lay-Stranded.
3.B-232 Aluminum Conductors, Concentric- Lay-Stranded, Coated Steel Reinforced (ACSR).
4.B-399 Concentric-Lay-Stranded, 6201-T81 Aluminum Alloy Conductors.
5.B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
6.Quadruplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474.
ABC Cables Using Properties
1.Rated Voltage:0.6/1kV
2.Cable installation temperature not less than -20°C
3.Max. temperature of cable at short circuit(The max. duration does not exceed 5 minutes)
For XLPE insulation is 250°C.
For HDPE insulation is 150 °C.
4.The Max. bending radius of cable shall not be less than 20Dmm(D overall diameter of cable)
Type of ABC Cable
1.Duplex Service Drop:To supply 120 volt aerial service for temporary service at construction sites,outdoor or street lighting . For service at 600 volts or lower at a conductor temperature of 75 maximum.
2.Triplex Service Drop: To supply power from the ulility`s lines to the consumer`s weatherhead. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation .
3.Quadruplex Service Drop: Used to supply 3 phase power , usually from a pole-mounted transformer to the use`s servic head where connection to the service entance cable is made . To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors.
ASTM B-230, B-231 and ICEA S-66-524
UL Standard 854 for type USE
Federal Specification JC-30B NEC
|
Code Name |
Phase Conductor |
Neutral |
Single Phase Conductor(in) |
Outside diameter(in) |
Weight Per 1000ft (lbls) |
Ampacity |
|||||
|
Size AWG |
Strand |
Insulation Thickness (mls) |
Size AWG |
Strand |
Insulation Thickness (mls) |
Direct Burial |
In Duct |
||||
|
Tulsa |
4 |
7/w |
60 |
4 |
7/w |
60 |
.345 |
.833 |
258 |
119 |
85 |
|
Dyke |
2 |
7/w |
60 |
4 |
7/w |
60 |
.403 |
.938 |
346 |
153 |
115 |
|
Wittenberg |
2 |
7/w |
60 |
2 |
7/w |
60 |
.403 |
.973 |
375 |
153 |
115 |
|
Notre Dame |
1/0 |
19/w |
80 |
2 |
7/w |
60 |
.522 |
1.188 |
541 |
198 |
150 |
|
Purdue |
1/0 |
19/w |
80 |
1/0 |
19/w |
80 |
.522 |
1.260 |
596 |
198 |
150 |
|
Syracuse |
2/0 |
19/w |
80 |
1/0 |
19/w |
80 |
.566 |
1.316 |
664 |
225 |
170 |
|
Lafayette |
2/0 |
19/w |
80 |
2/0 |
19/w |
80 |
.566 |
1.367 |
720 |
225 |
170 |
|
Swarthmore |
3/0 |
19/w |
80 |
1/0 |
19/w |
80 |
.616 |
1.430 |
805 |
250 |
195 |
|
Davidson |
3/0 |
19/w |
80 |
3/0 |
19/w |
80 |
.616 |
1.487 |
874 |
250 |
195 |
|
Wake Forest |
4/0 |
19/w |
80 |
2/0 |
19/w |
80 |
.672 |
1.560 |
979 |
290 |
225 |
|
Earlham |
4/0 |
19/w |
80 |
4/0 |
19/w |
80 |
.672 |
1.623 |
1066 |
290 |
225 |
|
Slippery Rock |
350 |
37/w |
95 |
4/0 |
19/w |
80 |
.851 |
1.945 |
1544 |
385 |
305 |
|
Wofford |
500 |
37/w |
95 |
350 |
37/w |
95 |
.851 |
2.348 |
2174 |
467 |
420 |
|
Windham |
750 |
61/w |
110 |
500 |
37/w |
95 |
.979 |
2.850 |
2542 |
615 |
492 |
We are China Power Distribution Aerial Isolated ABC Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular ABC Cable Products
0.6/1kv Overhead Insulated Cable-ABC Cable (Quadruplex Service Drop)
600V Secondary Distribution Urd Cable
LV 0.6/1kv Aaluminium Conductor Steel Reinforced XLPE Insulated ABC Cable
Free Samples, AS/NZS 3599.2, Hv ABC Cable, Al/XLPE+AAAC Aerial Bundled Cable
Multicore ABC Cable Amka 2X16 Low Voltage LV Aluminum XLPE Overhead
Popular huatongcable Products
Bare ACSR Conductor 400mm2 for Power Distribution
ASTM Overhead Aluminium Conductor Steel Supported Acss for Transmission Line
800mcm Stranded Copper Thw/Tw Wire Electric Cable
ANSI Disc Insulation Type Suspension Porcelain Insulator for High Voltage
Wholesale Price for Bare Conductor AAC/AAAC/ACSR Conductor
IEC Standard China Cable Aacsr AAAC ACSR for Overhead Line
Popular Powe Cable Products
ABC Cable Aerial Bunched/Bundled Cable
ASTM Standard Urd Cable PE/XLPE Insulation
Multi Cores Aluminum Cores PVC Insulated Power Cable
0.6/1kv 3 Cores Aluminum /PVC Insulated Power Cable
Power Distribution Aluminium Urd Cable
ASTM Standard Bare Aluminum Alloy Cable 350mcm AAAC Conductor
Popular Urd Cable Products
UL 1072 Standard Medium Voltage Urd 35kv 345mil Trxlp (100% Insulation) Urd Cable
ASTM Standard 600V XLPE Insulated Urd Cable
10kv 15kv 20kv 35kv XLPE/Swa/PVC Cable Single Aluminum Cable Trxlpe Insulation 2/0 Copper Cable
8AWG-1000 Kcmil Underground Distribution Cws Shield 25kv Aluminum 35kv Urd Cable
Tags: ABC Cable, huatongcable, Powe Cable, Urd Cable