Power and Signal Cable 0, 6/1kv, PVC Insulated and Sheathed Nyy Cable
Power and Signal Cable 0, 6/1kv, PVC Insulated and Sheathed Nyy Cable image
Get Latest Price Request a quote
Quick Details
Product Details
Medium voltage Single Core cable 6/10 kV, 12/20 kV, 18/30 kV, N2XS(F)2Y Cable
1. Main Application
Distribution and signal power cable for static outdoor application (with protection against direct UV-irradiation), in ground, in water, within facilities, in cable canals, in concrete, in conditions where heavier mechanical loads and specially tensile strains, are not expected. Used in electric power plants, transformer stations, industrial plants, metropolitan networks and in other electric plants, same as for connection of signalling devices in industry, traffic and similar.
2. Standards
HRN HD 603 S1
IEC 60502-1
DIN VDE 0276 part 603
cables with 6 and more conductors:
HRN HD 627 S1
DIN VDE 0276-627
3. Products Type
Power NYY-JZ, NYY-OZ
| Dimensions – number of cores x conductor cross-section | Construction | Construction of individual conductor | External diameter | Insulation thickness | Conductor resistance at 20 °C | Short circuit current 1s | Cu weight | Cable weight | Packing* |
| nominal | min-max. | nom. | max. | nom. | prib. | ||||
| N x mm² | n x mm | mm | mm | Ω/km | kA | kg/km | kg/km | ||
| 1 x 4 | RE | 1 x 2,25 | 9,0 – 11,0 | 1,0 | 4,61 | 0,46 | 38,4 | 110 | CUT |
| 1 x 6 | RE | 1 x 2,76 | 9,0 – 11,0 | 1,0 | 3,08 | 0,69 | 57,6 | 130 | CUT |
| 1 x 10 | RE | 1 x 3,56 | 10,0 – 12,0 | 1,0 | 1,83 | 1,15 | 96 | 180 | CUT |
| 1 x 16 | RE | 1 x 4,51 | 10,0 – 13,0 | 1,0 | 1,15 | 1,84 | 153,6 | 240 | CUT |
| 1 x 25 | RM | 7 x 2,13 | 12,0 – 15,0 | 1,2 | 0,727 | 2,87 | 240 | 350 | CUT |
| 1 x 35 | RM | 7 x 2,52 | 13,0 – 16,0 | 1,2 | 0,524 | 4,02 | 336 | 460 | CUT |
| 1 x 50 | RM | 19 x 1,83 | 14,0 – 17,0 | 1,4 | 0,387 | 5,75 | 480 | 600 | CUT |
| 1 x 70 | RM | 19 x 2,17 | 16,0 – 19,0 | 1,4 | 0,268 | 8,05 | 672 | 800 | CUT |
| 1 x 95 | RM | 19 x 2,52 | 18,0 – 21,0 | 1,6 | 0,193 | 10,90 | 912 | 1100 | CUT |
| 1 x 120 | RM | 37 x 2,03 | 19,0 – 22,0 | 1,6 | 0,153 | 13,80 | 1152 | 1350 | CUT |
| 1 x 150 | RM | 37 x 2,27 | 21,0 – 25,0 | 1,8 | 0,124 | 17,20 | 1440 | 1650 | CUT |
| 1 x 185 | RM | 37 x 2,52 | 23,0 – 27,0 | 2,0 | 0,0991 | 21,30 | 1776 | 2000 | CUT |
| 1 x 240 | RM | 61 x 2,24 | 26,0 – 30,0 | 2,2 | 0,0754 | 27,60 | 2304 | 2600 | CUT |
| 1 x 300 | RM | 61 x 2,50 | 28,0 – 32,0 | 2,4 | 0,0601 | 34,50 | 2880 | 3200 | CUT |
| 1 x 400 | RM | 61 x 2,89 | 32,0 – 37,0 | 2,6 | 0,047 | 41,20 | 3840 | 4100 | CUT |
| 1 x 500 | RM | 61 x 3,23 | 35,0 – 40,0 | 2,8 | 0,0366 | 51,50 | 4800 | 5200 | CUT |
| 1 x 630 | RM | 91 x 2,97 | 41,0 – 45,0 | 2,8 | 0,0283 | 64,00 | 6048 | 6650 | CUT |
| 2 x 1,5 | RE | 1 x 1,38 | 11,0 – 13,0 | 0,8 | 12,1 | 0,173 | 28,8 | 190 | CUT |
| 2 x 2,5 | RE | 1 x 1,78 | 12,0 – 14,0 | 0,8 | 7,41 | 0,288 | 48 | 230 | CUT |
| 2 x 4 | RE | 1 x 2,25 | 13,0 – 15,0 | 1,0 | 4,61 | 0,46 | 76,8 | 310 | CUT |
| 2 x 6 | RE | 1 x 2,76 | 14,0 – 16,0 | 1,0 | 3,08 | 0,69 | 115,2 | 380 | CUT |
| 2 x 10 | RE | 1 x 3,56 | 16,0 – 18,0 | 1,0 | 1,83 | 1,15 | 192 | 510 | CUT |
| 2 x 16 | RE | 1 x 4,51 | 18,0 – 20,0 | 1,0 | 1,15 | 1,84 | 307,2 | 705 | CUT |
| 2 x 25 | RM | 7 x 2,13 | 22,2 | 1,2 | 0,727 | 2,87 | 480 | 1010 | CUT |
| 2 x 35 | RM | 7 x 2,52 | 24,4 | 1,2 | 0,524 | 4,02 | 672 | 1285 | CUT |
| 3 x 1,5 | RE | 1 x 1,38 | 11,0 – 14,0 | 0,8 | 12,1 | 0,17 | 43,2 | 190 | CUT |
| 3 x 2,5 | RE | 1 x 1,78 | 12,0 – 15,0 | 0,8 | 7,41 | 0,29 | 72 | 240 | CUT |
| 3 x 4 | RE | 1 x 2,25 | 14,0 – 17,0 | 1,0 | 4,61 | 0,46 | 115,2 | 330 | CUT |
| 3 x 6 | RE | 1 x 2,76 | 15,0 – 18,0 | 1,0 | 3,08 | 0,69 | 172,8 | 420 | CUT |
| 3 x 10 | RE | 1 x 3,56 | 17,0 – 20,0 | 1,0 | 1,83 | 1,15 | 288 | 580 | CUT |
| 3 x 10 | RM | 7 x 1,35 | 17,0 – 20,0 | 1,0 | 1,83 | 1,15 | 288 | 580 | CUT |
| 3 x 16 | RE | 1 x 4,51 | 18,0 – 21,0 | 1,0 | 1,15 | 1,84 | 460,8 | 810 | CUT |
| 3 x 16 | RM | 7 x 1,70 | 18,0 – 21,0 | 1,0 | 1,15 | 1,84 | 460,8 | 810 | CUT |
| 3 x 25 | RM | 7 x 2,13 | 24,0 – 27,0 | 1,2 | 0,727 | 2,87 | 720 | 1300 | CUT |
| 3 x 35 | SM | 7 x 2,52 | 22,0 – 25,0 | 1,2 | 0,524 | 4,02 | 1008 | 1400 | CUT |
| 3 x 50 | SM | 19 x 1,83 | 25,0 – 29,0 | 1,4 | 0,387 | 5,75 | 1440 | 1800 | CUT |
| 3 x 70 | SM | 19 x 2,17 | 29,0 – 34,0 | 1,4 | 0,268 | 8,05 | 2016 | 2400 | CUT |
| 3 x 95 | SM | 19 x 2,52 | 33,0 – 37,0 | 1,6 | 0,193 | 10,90 | 2736 | 3300 | CUT |
| 3 x 120 | SM | 37 x 2,03 | 35,0 – 40,0 | 1,6 | 0,153 | 13,80 | 3456 | 4000 | CUT |
| 3 x 150 | SM | 37 x 2,27 | 39,0 – 44,0 | 1,8 | 0,124 | 17,20 | 4320 | 4900 | CUT |
| 3 x 185 | SM | 37 x 2,52 | 45,0 – 50,0 | 2,0 | 0,0991 | 21,30 | 5328 | 6500 | CUT |
| 3 x 240 | SM | 61 x 2,24 | 50,0 – 55,0 | 2,2 | 0,0754 | 27,60 | 6912 | 8300 | CUT |
| 3 x 25 + 16 | RM/RE | 7 x 2,13 | 25,0 – 31,0 | 1,2 | 0,727 | 2,87 | 873,6 | 1500 | CUT |
| 3 x 35 + 16 | SM/RE | 7 x 2,52 | 25,0 – 32,0 | 1,2 | 0,524 | 4,02 | 1161,6 | 1700 | CUT |
| 3 x 50 + 25 | SM/RM | 19 x 1,83 | 28,0 – 35,0 | 1,4 | 0,387 | 5,75 | 1680 | 2300 | CUT |
| 3 x 70 + 35 | SM/SM | 19 x 2,17 | 31,0 – 38,0 | 1,4 | 0,268 | 8,05 | 2352 | 2800 | CUT |
| 3 x 95 + 50 | SM/SM | 19 x 2,52 | 36,0 – 43,0 | 1,6 | 0,193 | 10,90 | 3216 | 3800 | CUT |
| 3 x 120 + 70 | SM/RM | 37 x 2,03 | 37,0 – 45,0 | 1,6 | 0,153 | 13,80 | 4128 | 4700 | CUT |
| 3 x 150 + 70 | SM/SM | 37 x 2,27 | 42,0 – 50,0 | 1,8 | 0,124 | 17,20 | 4992 | 5600 | CUT |
| 3 x 185 + 95 | SM/SM | 37 x 2,52 | 44,0 – 52,0 | 2,0 | 0,0991 | 21,30 | 6240 | 7400 | CUT |
| 3 x 240 + 120 | SM/SM | 61 x 2,24 | 46,0 – 54,0 | 2,0 | 0,0754 | 27,60 | 8064 | 9600 | CUT |
| 3 x 300 + 150 | SM/SM | 61 x 2,50 | 63,0 – 71,0 | 2,0 | 0,0601 | 34,50 | 10080 | 11200 | CUT |
| 4 x 4 | RE | 1 x 2,25 | 15,0 – 19,0 | 1,0 | 4,61 | 0,46 | 153,6 | 400 | CUT |
| 4 x 6 | RE | 1 x 2,76 | 16,0 – 20,0 | 1,0 | 3,08 | 0,69 | 230,4 | 510 | CUT |
| 4 x 10 | RE | 1 x 3,56 | 18,0 – 22,0 | 1,0 | 1,83 | 1,15 | 384 | 720 | CUT |
| 4 x 10 | RM | 7 x 1,35 | 18,0 – 22,0 | 1,0 | 1,83 | 1,15 | 384 | 720 | CUT |
| 4 x 16 | RE | 1 x 4,51 | 21,0 – 25,0 | 1,0 | 1,15 | 1,84 | 614,4 | 1050 | CUT |
| 4 x 16 | RM | 7 x 1,70 | 21,0 – 25,0 | 1,0 | 1,15 | 1,84 | 614,4 | 1050 | CUT |
| 4 x 25 | RM | 7 x 2,13 | 25,0 – 32,0 | 1,2 | 0,727 | 2,87 | 960 | 1600 | CUT |
| 4 x 35 | SM | 7 x 2,52 | 27,0 – 34,0 | 1,2 | 0,524 | 4,02 | 1344 | 1750 | CUT |
| 4 x 50 | SM | 19 x 1,83 | 29,0 – 36,0 | 1,4 | 0,387 | 5,75 | 1920 | 2300 | CUT |
| 4 x 70 | SM | 19 x 2,17 | 33,0 – 40,0 | 1,4 | 0,268 | 8,05 | 2688 | 3100 | CUT |
| 4 x 95 | SM | 19 x 2,52 | 38,0 – 45,0 | 1,6 | 0,193 | 10,90 | 3648 | 4200 | CUT |
| 4 x 120 | SM | 37 x 2,03 | 41,0 – 49,0 | 1,6 | 0,153 | 13,80 | 4608 | 5200 | CUT |
| 4 x 150 | SM | 37 x 2,27 | 46,0 – 54,0 | 1,8 | 0,124 | 17,20 | 5760 | 6400 | CUT |
| 4 x 185 | SM | 37 x 2,52 | 51,0 – 59,0 | 2,0 | 0,0991 | 21,30 | 7104 | 8050 | CUT |
| 4 x 240 | SM | 61 x 2,24 | 57,0 – 65,0 | 2,2 | 0,0754 | 27,60 | 9216 | 11000 | CUT |
| 4 x 300 | SM | 61 x 2,50 | 63,9 | 2,4 | 0,0601 | 11520 | 13245 | CUT | |
| 5 x 1,5 | RE | 1 x 1,38 | 13,0 – 16,0 | 0,8 | 12,1 | 0,17 | 72 | 270 | CUT |
| 5 x 2,5 | RE | 1 x 1,78 | 14,0 – 17,0 | 0,8 | 7,41 | 0,29 | 120 | 350 | CUT |
| 5 x 4 | RE | 1 x 2,25 | 15,0 – 18,0 | 1,0 | 4,61 | 0,46 | 192 | 480 | CUT |
| 5 x 6 | RE | 1 x 2,76 | 18,0 – 21,0 | 1,0 | 3,08 | 0,69 | 288 | 610 | CUT |
| 5 x 10 | RE | 1 x 3,56 | 19,0 – 22,0 | 1,0 | 1,83 | 1,15 | 480 | 880 | CUT |
| 5 x 10 | RM | 7 x 1,35 | 19,0 – 22,0 | 1,0 | 1,83 | 1,15 | 480 | 880 | CUT |
| 5 x 16 | RE | 1 x 4,51 | 22,0 – 25,0 | 1,0 | 1,15 | 1,84 | 768 | 1250 | CUT |
| 5 x 16 | RM | 7 x 1,70 | 22,0 – 25,0 | 1,0 | 1,15 | 1,84 | 768 | 1250 | CUT |
| 5 x 25 | RM | 7 x 2,13 | 27,0 – 33,0 | 1,2 | 0,727 | 2,87 | 1200 | 1950 | CUT |
| 5 x 35 | RM | 7 x 2,52 | 33,0 – 40,0 | 1,2 | 0,524 | 4,02 | 1680 | 2400 | CUT |
| 5 x 50 | RM | 19 x 1,83 | 39,0 – 45,0 | 1,2 | 0,387 | 5,75 | 2400 | 3500 | CUT |
| 5 x 70 | RM | 19 x 2,17 | 41,0 – 47,0 | 1,4 | 0,268 | 8,05 | 3360 | 4450 | CUT |
| 5 x 95 | RM | 19 x 2,52 | 46,0 – 52,0 | 1,4 | 0,193 | 10,90 | 4560 | 6134 | CUT |
| 5 x 120 | RM | 37 x 2,03 | 51,0 – 57,0 | 1,6 | 0,153 | 13,80 | 5760 | 7483 | CUT |
Signal NYY-JZ, NYY-OZ
| Dimensions – number of cores x conductor cross-section | Construction | Construction of individual conductor | External diameter | Insulation thickness | Conductor resistance at 20 °C | Short circuit current 1s | Cu weight | Cable weight | Packing* |
| nominal | min-maks. | nominal | max. | nominal | prib.. | ||||
| N x mm² | n x mm | mm | mm | Ω/km | kA | kg/km | kg/km | ||
| 7 x 1,5 | RE | 1 x 1,38 | 14,1-17 | 0,8 | 12,1 | 0,17 | 100,8 | 300 | CUT |
| 10 x 1,5 | RE | 1 x 1,38 | 17,2-21 | 0,8 | 12,1 | 0,17 | 144 | 360 | CUT |
| 12 x 1,5 | RE | 1 x 1,38 | 17,7-22 | 0,8 | 12,1 | 0,17 | 172,8 | 400 | CUT |
| 14 x 1,5 | RE | 1 x 1,38 | 18,5-23 | 0,8 | 12,1 | 0,17 | 201,6 | 450 | CUT |
| 16 x 1,5 | RE | 1 x 1,38 | 19,4-24 | 0,8 | 12,1 | 0,17 | 230,4 | 500 | CUT |
| 19 x 1,5 | RE | 1 x 1,38 | 20,3-25 | 0,8 | 12,1 | 0,17 | 273,6 | 560 | CUT |
| 21 x 1,5 | RE | 1 x 1,38 | 20,9-25 | 0,8 | 12,1 | 0,17 | 302,4 | 620 | CUT |
| 24 x 1,5 | RE | 1 x 1,38 | 22,9-28 | 0,8 | 12,1 | 0,46 | 345,6 | 700 | CUT |
| 30 x 1,5 | RE | 1 x 1,38 | 24,3-29 | 0,8 | 12,1 | 0,46 | 432 | 810 | CUT |
| 40 x 1,5 | RE | 1 x 1,38 | 27,1-33 | 0,8 | 12,1 | 0,46 | 576 | 1050 | CUT |
| 52 x 1,5 | RE | 1 x 1,38 | 32 | 0,8 | 12,1 | 0,17 | 748,8 | 1400 | CUT |
| 61 x 1,5 | RE | 1 x 1,38 | 34 | 0,8 | 12,1 | 878,4 | 1650 | CUT | |
| 7 x 2,5 | RE | 1 x 1,78 | 15,9-18 | 0,8 | 7,41 | 0,29 | 168 | 420 | CUT |
| 10 x 2,5 | RE | 1 x 1,78 | 19,6-22 | 0,8 | 7,41 | 0,29 | 240 | 500 | CUT |
| 12 x 2,5 | RE | 1 x 1,78 | 20,2-23 | 0,8 | 7,41 | 0,29 | 288 | 560 | CUT |
| 14 x 2,5 | RE | 1 x 1,78 | 21-24 | 0,8 | 7,41 | 0,29 | 336 | 630 | CUT |
| 16 x 2,5 | RE | 1 x 1,78 | 22-25 | 0,8 | 7,41 | 0,29 | 384 | 710 | CUT |
| 19 x 2,5 | RE | 1 x 1,78 | 23-26 | 0,8 | 7,41 | 0,29 | 456 | 830 | CUT |
| 21 x 2,5 | RE | 1 x 1,78 | 24,1-27 | 0,8 | 7,41 | 0,29 | 504 | 910 | CUT |
| 24 x 2,5 | RE | 1 x 1,78 | 26,9-30 | 0,8 | 7,41 | 0,69 | 576 | 1050 | CUT |
| 30 x 2,5 | RE | 1 x 1,78 | 28-32 | 0,8 | 7,41 | 0,69 | 720 | 1250 | CUT |
| 40 x 2,5 | RE | 1 x 1,78 | 31-36 | 0,8 | 7,41 | 0,69 | 960 | 1650 | CUT |
| 52 x 2,5 | RE | 1 x 1,78 | 35-36,2 | 0,8 | 7,41 | 0,29 | 1248 | 2150 | CUT |
| 7 x 4 | RE | 1 x 2,25 | 18-21 | 1,0 | 4,61 | 0,46 | 268,8 | 630 | CUT |
| 10 x 4 | RE | 1 x 2,25 | 22 | 1,0 | 4,61 | 0,46 | 384 | 830 | CUT |
| 12 x 4 | RE | 1 x 2,25 | 22-25 | 1,0 | 4,61 | 0,46 | 460,8 | 965 | CUT |
| 14 x 4 | RE | 1 x 2,25 | 25 | 1,0 | 4,61 | 0,46 | 537,6 | 1000 | CUT |
| 16 x 4 | RE | 1 x 2,25 | 26 | 1,0 | 4,61 | 0,46 | 614,4 | 1245 | CUT |
| 19 x 4 | RE | 1 x 2,25 | 27 | 1,0 | 4,61 | 0,46 | 729,6 | 1420 | CUT |
| 7 x 6 | RE | 1 x 2,76 | 20-23 | 1,0 | 3,08 | 0,69 | 403,2 | 840 | CUT |
| 10 x 6 | RE | 1 x 2,76 | 24 | 1,0 | 3,08 | 0,69 | 576 | 1065 | CUT |
| 12 x 6 | RE | 1 x 2,76 | 25 | 1,0 | 3,08 | 0,69 | 691,2 | 1235 | CUT |
| 14 x 6 | RE | 1 x 2,76 | 26 | 1,0 | 3,08 | 0,69 | 806,4 | 1405 | CUT |
| 16 x 6 | RE | 1 x 2,76 | 28 | 1,0 | 3,08 | 0,69 | 921,6 | 1580 | CUT |
| 19 x 6 | RE | 1 x 2,76 | 29 | 1,0 | 3,08 | 0,69 | 1094,4 | 1810 | CUT |
| 7 x 10 | RE | 1 x 3,56 | 23 | 1,0 | 1,83 | 1,15 | 672 | 1150 | CUT |
*) Packing: CUT = cable in different lengths on drum or reel, possible cutting at required length
4. Technical data
| Temperature range: | |
| during installation: | -5 °C up to +50 °C |
| fixed installed: | -30 °C up to +70 °C |
| at short circuit of max. 5 s: | up to 160 °C |
| Nominal voltage: | Uο/U = 0,6/1 kV |
| Test voltage: | 4 kV |
| Max. operating voltage in three-phase systems: | 1,2 kV |
| Maximal tensile strength: | 50 N/mm² |
| Behaviour in fire: | IEC 60332-1 |
| Minimal inner bending radius: | |
| single core: | 15D |
| multi core: | 12D |
5. Construction
| Conductor: | Cu, class 1 or 2 acc. to HRN HD 383 / IEC 60228 / DIN VDE 0295 | |
| class 1: | solid, round(RE) or sector (SE) | |
| class 2: | multi wire stranded, round (RM) or sector (SM), multi wire exceeding 50 mm² are compacted | |
| Insulation: | PVC compound DIV-4 acc. to HRN HD 603.1 | |
| Filler: | extruded elastomer or plastomer compound or wrapped thermoplastic tapes | |
| Sheath: | PVC compound DMV-5 acc. to HRN HD 603.1 | |
| sheath colour: | black | |
| Core colour marking: | HRN HD 308 S2 / VDE 0293-308 | |
6. Factory
Henan Hongda Cable Co., Ltd. located in No. 3, Changping Road, ZhanDian District, Jiaozuo, Wuzhi. Our factroy established in March of 2004. Our owns registered capital of RMB Fifty-one million six hundred and eighty thousand. Hongda Cable
covers an area of 100,000 square meters, including 50,000 square meters of building area. We have more than 120 staff members and professional workers. our fixed assets of 90,000,000. We can provide more than 100 varieties, tens of thousands of specifications of wire and cable, with 10000 km annual production capacity
Henan Hongda Cable Co. Ltd. is the original Zhengzhou Hongda Cable Co. Ltd. established enterprise expansion. The company is committed to system R&D, design, manufacturing, marketing and service of cable products,We mainly aim at managing cross-linking XLPE insulated power cables, PVC insulated power cables, plastic insulated control cables, insulated overhead cables, and stranded aluminum and ACSR. At present, the cables’ biggest cross area is 800 square meters with a maximum electric power of 35KV. The company has more than 300 (sets) domestic and oversea-leading production and testing equipment
7. Packing and Transportation
We provide you with the best product packaging design services, thereby allowing you to save more shipping charges
8. Certificate
9. FAQ
Q: Are you the factory or the trading company?
A: We are the factory.
Q: How long is your guarantee Period?
A: We uaually offer 1 year guarantee for our general products.
Q: How can I get the samples?
A: We can make the sample order. And usually we will charge for it.
But the samples fee will be return to you when you make the bulk order.
Q: Where is your factory? How can we visit your factory?
A: Our factory located in Zhengzhou city, Henan Province. You could reach here by train and by air.
We can pick you up in the airport and the railway station.
Q; What is your MOQ?
A: It`s base on the cable type or wire type.
Frank Hu
We are China Power and Signal Cable 0, 6/1kv, PVC Insulated and Sheathed Nyy Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Cable Products
UL3122 Heat Resistant Silicone Rubber Fiberglass Wire Cable
High Voltage Service Drop Wire ABC Electric Power Cable for South Africa
Yjv 35mm Power Cable XLPE Cable Insulate Power Cable
XLPE/ PVC Insulated Electrical/ Electric Wire Cable, Copper/Aluminium Power Cable.
Overhead Aluminium Bare Stranded Conductor AAC Conductor (ASTM/BS/EC Standard)
(2.5mmsq /4.0mmsq /6.0mmsq/10.0mmsq) PV Solar Power Cable UL and TUV Approved Solar PV Cable
Popular Nyy Products
IEC 60227-4, DIN VDE Nvv, Nyy Power Cable
Cables BT de distribution 4X120mm2 Cu Cuivre Type NYY PVC Insulated 0.6/1kV
Cables BT de distribution 4X50mm2 Cu Cuivre Type NYY PVC Insulated 0.6/1kV
(N) Ym (ST) -J Cable with Shield Drain Wire
0.6/1kv Multicore Nyy Electric Cable
Nyy Power and Control Cable for Fixed Installation HD 603 DIN VDE 0276 Bs 6346
Popular Nyy Cable Products
Low Voltage 0.6/1kv Nyy Electrical Cable
Nyy Cable Low Voltage PVC Insulation Copper Cable
25mm Copper/Aluminum Conductor PVC Insulated and Sheathed Electrical Nyy/Nayy Power Cable 0.6/1kv
0.6/1kv Nyy-J/O Copper Core PVC Insulated Electric Power Cable
Copper XLPE Insulated Flame Retardant Armored Power Cable
Popular zzhongdacable Products
ASTM Standard 600V AWG Size 80mm2 100mm2 125mm2 PVC Electrical Copper Wire Thw Tw
Yellow Green Stranded Copper 70mm2 Electric Earthing Cable
IEC 60502-1 N2xby Power Cable 0.6/1 Kv Cu/XLPE/PVC/ATA/PVC
3/0-3/0-1/0 Hollins Triplex Aluminum Conductor Direct Burial 600V Urd Cable
Twin with Earth 2.5mm Electro Cables Australian Standard AS/NZS 5000.2 Flat TPS Cable
Tags: Cable, Nyy, Nyy Cable, zzhongdacable