AAC AAAC Aluminum Bare Conductor for Overhead Transmission
AAC AAAC Aluminum Bare Conductor for Overhead Transmission image
Get Latest Price Request a quote
Quick Details
Product Details
Simple structure / Easy installation and maintenance / Low circuit cost / Large transmission capacity / Good conductive performance / Sufficient mechanical strength / High tensile strength
ACSR Cable Advantage:
1. Convenient for laying across special geographical conditions such as rivers and valleys
2.The tower distance can be enlarged
ACSR Cable Application:
Widely used in overhead power transmission lines of various voltage levels
AAAC Cable Applications
AAAC Aluminum Alloy Conductor is Used as bare overhead conductor for primary and secondary distribution. Designed utilizing a high-strength aluminum alloy to achieve a high strength-to-weight ratio; affords better sag characteristics. Aluminum alloy gives higher resistance to corrosion than ACSR.
Standard
BS EN50183,IEC 61089, ASTM B399,BS 3242, DIN 48204,GB/T1179-2008
Specification
Physical contents of aluminum alloy :-
1. Resistivity – 0.0326 Ohms mm2/m at 20°C
2. Density – 2.70 kgm/dm3 at 20°C
3. Coefficient of Linear Expansion – 23 x 10-6 / °C
4. Constant Mass Temperature Coefficient (a) – 0.00360/ °C
5. Material – Heat treated Al. Mg. Si. Alloy
– Approximately 0.5% Mg & 0.5% Si
ASTM B399
| Code Name | Area | Size & Stranding of ACSR with Equal Diameter | No. & Diameter of wires | Overall Diameter | Weight | Nominal Breaking Load | ||
| Nominal | Actual | |||||||
| MCM | mm2 | AWG or MCM | Al/Steel | mm | mm | kg/km | kN | |
| Akron | 30.58 | 15.48 | 6 | 6/1 | 7/1.68 | 5.04 | 42.7 | 4.92 |
| Alton | 48.69 | 24.71 | 4 | 6/1 | 7/2.12 | 6.35 | 68.0 | 7.84 |
| Ames | 77.47 | 39.22 | 2 | 6/1 | 7/2.67 | 8.02 | 108 | 12.45 |
| Azusa | 123.3 | 62.38 | 1/0 | 6/1 | 7/3.37 | 10.11 | 172 | 18.97 |
| Anaheim | 155.4 | 78.65 | 2/0 | 6/1 | 7/3.78 | 11.35 | 217 | 23.93 |
| Amherst | 195.7 | 99.22 | 3/0 | 6/1 | 7/4.25 | 12.75 | 273 | 30.18 |
| Alliance | 246.9 | 125.1 | 4/0 | 6/1 | 7/4.77 | 14.31 | 345 | 38.05 |
| Butte | 312.8 | 158.6 | 266.8 | 26/7 | 19/3.26 | 16.30 | 437 | 48.76 |
| Canton | 394.5 | 199.9 | 336.4 | 26/7 | 19/3.66 | 18.30 | 551 | 58.91 |
| Cairo | 465.4 | 235.8 | 397.5 | 26/7 | 19/3.98 | 19.88 | 650 | 69.48 |
| Darien | 559.5 | 283.5 | 477.0 | 26/7 | 19/4.36 | 21.79 | 781 | 83.52 |
| Elgin | 652.4 | 330.6 | 556.5 | 26/7 | 19/4.71 | 23.54 | 911 | 97.42 |
| Flint | 740.8 | 375.3 | 636.0 | 26/7 | 37/3.59 | 25.16 | 1035 | 108.21 |
| Greely | 927.2 | 469.8 | 795.0 | 26/7 | 37/4.02 | 28.14 | 1295 | 135.47 |
IEC 61089
| Code Number | A2 Conductor | A3 Conductor | Max.D.C. Resistance of Conductor at 20ºC | ||||||||
| Number of Wires | Diameter of Wires | Diameter of Conductor | Approx. Weight | Rated Strength | Number of Wires | Diameter of Wires | Diameter of Conductor | Approx. Weight | Rated Strength | ||
| mm² | – | mm | mm | kg/km | daN | – | mm | mm | kg/km | daN | Ω/km |
| 16 | 7 | 1.83 | 5.49 | 50.4 | 5.43 | 7 | 1.84 | 5.52 | 50.8 | 6.04 | 1.7896 |
| 25 | 7 | 2.29 | 6.87 | 78.7 | 8.49 | 7 | 2.30 | 6.9 | 79.5 | 9.44 | 1.1453 |
| 40 | 7 | 2.89 | 8.67 | 125.9 | 13.58 | 7 | 2.91 | 8.73 | 127.1 | 15.1 | 0.7158 |
| 63 | 7 | 3.63 | 10.8 | 198.3 | 21.39 | 7 | 3.65 | 10.95 | 200.2 | 23.06 | 0.4545 |
| 100 | 19 | 2.78 | 13.9 | 316.3 | 33.95 | 19 | 2.79 | 13.95 | 319.3 | 37.76 | 0.2877 |
| 125 | 19 | 3.10 | 15.5 | 395.4 | 42.44 | 19 | 3.12 | 15.6 | 399.2 | 47.20 | 0.2302 |
| 160 | 19 | 3.51 | 17.55 | 506.1 | 54.32 | 19 | 3.53 | 17.65 | 511.0 | 58.56 | 0.1798 |
| 200 | 19 | 3.93 | 19.65 | 623.7 | 67.91 | 19 | 3.95 | 19.75 | 638.7 | 73.20 | 0.1439 |
| 250 | 19 | 4.39 | 21.95 | 790.8 | 84.68 | 19 | 4.41 | 22.05 | 798.4 | 91.50 | 0.1151 |
| 315 | 37 | 3.53 | 24.71 | 998.9 | 106.95 | 37 | 3.55 | 24.85 | 1008.4 | 115.29 | 0.0916 |
| 400 | 37 | 3.98 | 27.86 | 1268.4 | 135.81 | 37 | 4.0 | 28 | 1280.5 | 146.4o | 0.0721 |
| 450 | 37 | 4.22 | 29.54 | 1426.9 | 152.79 | 37 | 4.24 | 29.68 | 1440.5 | 164.70 | 0.0641 |
| 500 | 37 | 4.45 | 31.15 | 1585.5 | 169.76 | 37 | 4.47 | 31.29 | 1600.6 | 183.oo | 0.0577 |
| 560 | 61 | 3.67 | 33.03 | 1778.4 | 190.14 | 61 | 3.69 | 33.21 | 1795.3 | 204.95 | 0.0516 |
| 630 | 61 | 3.89 | 35.01 | 2000.7 | 213.90 | 61 | 3.91 | 35.19 | 2019.8 | 230.58 | 0.0458 |
| 710 | 61 | 4.13 | 37.17 | 2254.8 | 241.07 | 61 | 4.15 | 37.35 | 2276.2 | 259.86 | 0.0407 |
| 800 | 61 | 4.38 | 39.42 | 2540.6 | 271.62 | 61 | 4.4 | 39.6 | 2564.8 | 282.80 | 0.0361 |
| 900 | 91 | 3.81 | 41.91 | 2861.1 | 305.58 | 91 | 3.83 | 42.13 | 2888.3 | 329.40 | 0.0321 |
| 1000 | 91 | 4.01 | 44.11 | 3179.0 | 339.53 | 91 | 4.03 | 44.33 | 3209.3 | 366.00 | 0.0289 |
| 1120 | 91 | 4.25 | 46.75 | 3560.5 | 380.27 | 91 | 4.27 | 46.97 | 3594.4 | 409.92 | 0 0258 |
| 1250 | 91 | 4.49 | 49.39 | 3973.7 | 424.41 | – | – | – | – | ||
BS EN50183
| Code Name | Calculated Cross Section |
No..Dia.of Wires | Overall Diameter | Weight | Rated Strength |
| mm² | No./mm | mm | kg/km | kN | |
| Box | 18.8 | 7/1.85 | 5.55 | 51.4 | 5.55 |
| Acacia | 23.8 | 7/2.08 | 6.24 | 64.9 | 7.02 |
| Almond | 30.1 | 7/2.34 | 7.02 | 82.2 | 8.88 |
| Cedar | 35.5 | 7/2.54 | 7.62 | 96.8 | 10.46 |
| Deodar | 42.2 | 7/2.77 | 8.31 | 115.2 | 12.44 |
| Fir | 47.8 | 7/2.95 | 8.85 | 130.6 | 14.11 |
| Hazel | 59.9 | 7/3.30 | 9.90 | 163.4 | 17.66 |
| Pine | 71.6 | 7/3.61 | 10.8 | 195.6 | 21.14 |
| Holly | 84.1 | 7/3.91 | 11.7 | 229.5 | 24.79 |
| Willow | 89.7 | 7/4.04 | 12.1 | 245,0 | 26.47 |
| Oak | 118.9 | 7/4.65 | 14.0 | 324.5 | 35.07 |
| Mulberry | 150.9 | 19/3.18 | 15.9 | 414.3 | 44.52 |
| Ash | 180.7 | 19/3.48 | 17.4 | 496.1 | 53.31 |
| Elm | 211.0 | 19/3.76 | 18.8 | 579.2 | 62.24 |
| Poplar | 239.4 | 37/2.87 | 20.1 | 659.4 | 70.61 |
| Sycamore | 303.2 | 37/3.23 | 22.6 | 835.2 | 89.40 |
| Upas | 362.1 | 37/3.53 | 24.7 | 997.5 | 106.82 |
| Yew | 479.0 | 37/4.06 | 28.4 | 1319.6 | 141.31 |
| Totara | 498.1 | 37/4.14 | 29.0 | 1372.1 | 146.93 |
| Rubus | 586.9 | 61/3.50 | 31.5 | 1622.0 | 173.13 |
| Sorbus | 659.4 | 61/3.71 | 33.4 | 1822.5 | 194.53 |
| Araucaria | 821.1 | 61/4.14 | 37.3 | 2269.4 | 242.24 |
| Redwood | 996.2 | 61/4.56 | 41.0 | 2753.2 | 293.88 |
Din 48201
| Code number | Calculated area | Number of wires | Diameter of wire | Overall diameter of conductor | Linear mass | Rated tensile strength | Max. DC resistance at 20ºC |
| mm2 | mm2 | mm | mm | kg/km | daN | Ω/km | |
| 16 | 15.89 | 7 | 1.70 | 5.1 | 43 | 444 | 2.0910 |
| 25 | 24.25 | 7 | 2.10 | 6.3 | 66 | 677 | 1.3703 |
| 35 | 34.36 | 7 | 2.50 | 7.5 | 94 | 960 | 0.9669 |
| 50 | 49.48 | 7 | 3.00 | 9.0 | 135 | 1382 | 0.6714 |
| 50 | 48.35 | 19 | 1.80 | 9.0 | 133 | 1350 | 0.6905 |
| 70 | 65.81 | 19 | 2.10 | 10.5 | 181 | 1838 | 0.5073 |
| 95 | 93.27 | 19 | 2.50 | 12.5 | 256 | 2605 | 0.3579 |
| 120 | 116.99 | 19 | 2.80 | 14.0 | 322 | 3268 | 0.2854 |
| 150 | 147.11 | 37 | 2.25 | 15.8 | 406 | 4109 | 0.2274 |
| 185 | 181.62 | 37 | 2.50 | 17.5 | 500 | 5073 | 0.1842 |
| 240 | 242.54 | 61 | 2.25 | 20.3 | 670 | 6774 | 0.1383 |
| 300 | 299.43 | 61 | 2.50 | 22.5 | 827 | 8363 | 0.1120 |
| 400 | 400.14 | 61 | 2.89 | 26.0 | 1104 | 11176 | 0.0838 |
| 500 | 499.63 | 61 | 3.23 | 29.1 | 1379 | 13960 | 0.06709 |
| 625 | 626.20 | 91 | 2.96 | 32.6 | 1732 | 17490 | 0.0540 |
| 800 | 802.09 | 91 | 3.35 | 36.9 | 2218 | 22402 | 0.0418 |
| 1000 | 999.71 | 91 | 3.74 | 41.1 | 2767 | 27922 | 0.0335 |
We are China AAC AAAC Aluminum Bare Conductor for Overhead Transmission manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular AAAC Products
Al. Conductor Overhead Electric Transmission Cable
Bare AAAC Conductor with ASTM BS IEC
Overhead All Aluminum Alloy Conductor Cairo AAAC Bare Conductor
AAAC Conductor-All Aluminum Alloy Conductor
Overhead Electric Aluminum Wire Price AAAC Conductor with ISO Certificate
Bare Aluminum Conductor AAAC Conductor to ASTM BS DIN
Popular AAC Products
AAC All Aluminum Conductors/Overhead Conductor
All Aluminum Alloy Conductor 100AWG ASTM B399 AAAC Conductor with Grease
Overhead AAC/AAAC/ACSR/Acar Bare Conductor Electrical Conductor
AAC All Aluminum Conductor AAC Conductor Overhead Line
0.6/1kV 1X25+1X54,6mm2 Twisted ABC Aerial Bundled Overhead Cable NF C 33-209
Popular Bare Conductor Products
Flexible Solid Stranded Pure Bare Electric Copper Clad Aluminum Wire
Aluminium Conductor Steel Reinforced Conductor
ACSR Pelican Aluminium Conductor Steel Reinforced Bare Cable
Wholesale AAAC ACSR AAC All Aluminium or Alloy Overhead Bare Conductor
Bare Stranded Cable IEC 61089 / ASTM B 231 All Aluminum Conductor AAC AAAC
Popular wuhancable Products
USA Sizes ASTM B232 Overhead Conductor Steel Reinforced ACSR Raven
ABC Bunle Aerial XLPE Covered Aluminium Conductor Overhead ABC Cable
Low Voltage Aluminum Core XLPE Insulated Armored Electrical Power Cable
Hot Sale ACSR AAC AAAC Conductor Aluminum Cable for Overhead Power Transmission Line
British Sizes 3242 All Aluminum Alloy Condcutor AAAC Willow
Tags: AAAC, AAC, Bare Conductor, wuhancable