Medium Voltage XLPE Insulated Unarmoured Power Cable
Medium Voltage XLPE Insulated Unarmoured Power Cable image
Get Latest Price Request a quote
Quick Details
Product Details
Application
Media Voltage XLPE Insulated power cable is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable.
Property
1.The highest allowed operating temperature of conductor for long-term working is 90 degrees.
2.In short circuit (Max long term is no more than 5 seconds). The highest temperature for conductor is no more than 250 degrees.
3.The cable is laid without horizontal drop limit. The environment temperature should be no lower than 0 when lay. Otherwise it should be preheated.
4.Excellent electrical performance, resistance to chemical corrosion.
5.They can stand advisable traction when laid.They can stand traction from Outside.Left low smoke halogen-free after burned.Retard the burning of the cable.
Workshop
Shipment
FAQ
1. How many years has Henan Jiapu Cable Group been in production?
Founded in October 1998 by Mr. Gu, our facility has three separate manufacturing workshops within its 100,000-sq.-ft. building. In 2012, we operates in a new 666,000 sq. foot state-of-the-art facility in Xiaodian Industry Park.,Xinxiang, Henan ,China
2. What kinds of products does Jiapu Cable manufacture?
1)Bare Conductor ,such as AAC,AAAC,ACSR,ACAR,AACSR,ACSR/AW and so on;
2)Aerial Bundled Cable (1kV-35kV ),such as Duplex,Triplex,Quadruplex Drop Wires and so on;
3)PVC Insulated (Flexible ) Wire ;
4) PVC Insulated and Sheathed (Armoured) Power Cable;
5)Low, Medium, High Voltage (1kV-220kV) XLPE Insulated (Armoured) Power Cable;
6)Welding Cable, Control Cable, Concentric Cable, Rubber Sheathed Cable and so on;
3. What kind of certifications do you have?
SABS, CE, ISO9001-2000, SGS
4.Which markets do you involve mainly in?
Our products have been exported mainly to Africa, Middle East, South-east Asia, South America,Central America,North America, Europe ,Australia, etc.
5. Which standards do you comply with when you produce the electrical wires and cables ?
We are able to produce electrical wires and cables based on GB, JB, IEC, BS, DIN, ASTM, JIS, NF, AS/NZS, CSA, etc. Meanwhile, we can design and manufacture the cables according to the samples and technical specification the customer supply.
6. What is the min.order quantity ?
It depends on the type and size of electrical wires and cables. For some small electrical wires, 100 meters can be accepted .But for the power cables with medium or high voltage, that should comply with the property of installed equipments. Anyhow,we will try our best to solve the problem and meet with the requirement If you have special request.
7. What is the production capacity per week or per month ?
For the bare conductor, we can finish 3000 tons within one month. For power cables, that depends on the type and size. The total output value per month is approx. USD3,000,000.00 for insulated aluminum cables and that is approx. USD8,000,000.00 for insulated copper cables.
8. Do you supply the customers with installation service in foreign country ?
We don’t have professional installation teams in foreign country.But if that is necessary, we will recommend our partners to cooperate with you.
Specifications:
| 1)3.6/6(7.2)kV,3.6/6.6(7.2)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable | |||||||||
| Normal Cross Section of Conductor | Normal Diameter of Conductor | Normal Thickness of Insulation | Normal Thickness of | Normal Thickness of Outer Sheath | Approx. | Approx. Net Weight | Max. D.C. Resistance of Conductor at 20 | ||
| Copper Tape | Overall Dia. | Al Conductor | Cu Conductor | Al Conductor | Cu Conductor | ||||
| mm 2 | mm | mm | mm | mm | mm | kg/m | kg/m | Ω/km | Ω/km |
| 25 | 6 | 2.5 | 0.12 | 1.5 | 17.6 | 0.34 | 0.49 | 1.2 | 0.727 |
| 35 | 7 | 2.5 | 0.12 | 1.5 | 18.5 | 0.39 | 0.6 | 0.868 | 0.524 |
| 50 | 8.3 | 2.5 | 0.12 | 1.6 | 20 | 0.46 | 0.74 | 0.641 | 0.387 |
| 70 | 9.7 | 2.5 | 0.12 | 1.6 | 21.5 | 0.55 | 0.96 | 0.443 | 0.268 |
| 95 | 11.3 | 2.5 | 0.12 | 1.7 | 23.3 | 0.66 | 1.23 | 0.32 | 0.193 |
| 120 | 13 | 2.5 | 0.12 | 1.7 | 24.8 | 0.77 | 1.48 | 0.253 | 0.153 |
| 150 | 14.6 | 2.5 | 0.12 | 1.8 | 26.4 | 0.87 | 1.77 | 0.206 | 0.124 |
| 185 | 15.9 | 2.5 | 0.12 | 1.8 | 28.1 | 1.01 | 2.13 | 0.164 | 0.0991 |
| 240 | 18.3 | 2.6 | 0.12 | 1.9 | 30.9 | 1.23 | 2.71 | 0.125 | 0.0754 |
| 300 | 20.4 | 2.8 | 0.12 | 2 | 33.6 | 1.48 | 3.32 | 0.1 | 0.0601 |
| 400 | 23.2 | 3 | 0.12 | 2.1 | 37 | 1.81 | 4.16 | 0.0778 | 0.047 |
| 500 | 26.4 | 3.2 | 0.12 | 2.2 | 41.1 | 2.24 | 5.27 | 0.0605 | 0.0366 |
| 630 | 30.1 | 3.2 | 0.12 | 2.3 | 45 | 2.73 | 6.62 | 0.0469 | 0.0283 |
| 2)6/10(12)kV,6.35/11(12)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable | |||||||||
| Normal Cross Section of Conductor | Normal Diameter of Conductor | Normal Thickness of Insulation | Normal Thickness of | Normal Thickness of Outer Sheath | Approx. | Approx. Net Weight | Max. D.C. Resistance of Conductor at 20 | ||
| Copper Tape | Overall Dia. | Al Conductor | Cu Conductor | Al Conductor | Cu Conductor | ||||
| mm 2 | mm | mm | mm | mm | mm | kg/m | kg/m | Ω/km | Ω/km |
| 25 | 6 | 3.4 | 0.12 | 1.5 | 19.4 | 0.4 | 0.55 | 1.2 | 0.727 |
| 35 | 6.9 | 3.4 | 0.12 | 1.6 | 20.5 | 0.45 | 0.66 | 0.868 | 0.524 |
| 50 | 8.2 | 3.4 | 0.12 | 1.6 | 21.8 | 0.52 | 0.8 | 0.641 | 0.387 |
| 70 | 9.7 | 3.4 | 0.12 | 1.7 | 23.5 | 0.62 | 1.03 | 0.443 | 0.268 |
| 95 | 11.3 | 3.4 | 0.12 | 1.7 | 25.1 | 0.73 | 1.3 | 0.32 | 0.193 |
| 120 | 12.8 | 3.4 | 0.12 | 1.8 | 26.8 | 0.85 | 1.56 | 0.253 | 0.153 |
| 150 | 14.2 | 3.4 | 0.12 | 1.8 | 28.2 | 0.95 | 1.85 | 0.206 | 0.124 |
| 185 | 15.9 | 3.4 | 0.12 | 1.9 | 30.1 | 1.1 | 2.22 | 0.164 | 0.0991 |
| 240 | 18.3 | 3.4 | 0.12 | 2 | 32.7 | 1.33 | 2.8 | 0.125 | 0.0754 |
| 300 | 20.4 | 3.4 | 0.12 | 2 | 34.8 | 1.54 | 3.39 | 0.1 | 0.0601 |
| 400 | 23.2 | 3.4 | 0.12 | 2.2 | 38 | 1.87 | 4.22 | 0.0778 | 0.047 |
| 500 | 26.4 | 3.4 | 0.12 | 2.2 | 41.5 | 2.26 | 5.29 | 0.0605 | 0.0366 |
| 630 | 30.1 | 3.4 | 0.12 | 2.4 | 45.6 | 2.78 | 6.67 | 0.0469 | 0.0283 |
| 3)8.7/10(15)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable | |||||||||
| Normal Cross Section of Conductor | Normal Diameter of Conductor | Normal Thickness of Insulation | Normal Thickness of | Normal Thickness of Outer Sheath | Approx. | Approx. Net Weight | Max. D.C. Resistance of Conductor at 20 | ||
| Copper Tape | Overall Dia. | Al Conductor | Cu Conductor | Al Conductor | Cu Conductor | ||||
| mm 2 | mm | mm | mm | mm | mm | kg/m | kg/m | Ω/km | Ω/km |
| 25 | 6 | 4.5 | 0.12 | 1.6 | 21.8 | 0.48 | 0.63 | 1.2 | 0.727 |
| 35 | 6.9 | 4.5 | 0.12 | 1.7 | 22.9 | 0.54 | 0.75 | 0.868 | 0.524 |
| 50 | 8.2 | 4.5 | 0.12 | 1.7 | 24.2 | 0.61 | 0.89 | 0.641 | 0.387 |
| 70 | 9.7 | 4.5 | 0.12 | 1.8 | 25.9 | 0.72 | 1.13 | 0.443 | 0.268 |
| 95 | 11.3 | 4.5 | 0.12 | 1.8 | 27.5 | 0.84 | 1.4 | 0.32 | 0.193 |
| 120 | 12.8 | 4.5 | 0.12 | 1.9 | 29.2 | 0.96 | 1.67 | 0.253 | 0.153 |
| 150 | 14.2 | 4.5 | 0.12 | 1.9 | 30.6 | 1.06 | 1.96 | 0.206 | 0.124 |
| 185 | 15.9 | 4.5 | 0.12 | 2 | 32.5 | 1.22 | 2.34 | 0.164 | 0.0991 |
| 240 | 18.3 | 4.5 | 0.12 | 2.1 | 35.1 | 1.46 | 2.93 | 0.125 | 0.0754 |
| 300 | 20.4 | 4.5 | 0.12 | 2.1 | 37.2 | 1.68 | 3.52 | 0.1 | 0.0601 |
| 400 | 23.2 | 4.5 | 0.12 | 2.2 | 40.2 | 2 | 4.35 | 0.0778 | 0.047 |
| 500 | 26.4 | 4.5 | 0.12 | 2.3 | 43.9 | 2.43 | 5.45 | 0.0605 | 0.0366 |
| 630 | 30.1 | 4.5 | 0.12 | 2.4 | 47.8 | 2.93 | 6.83 | 0.0469 | 0.0283 |
| 4)12/20(24)kV, 12.7/22(24)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable | |||||||||
| Normal Cross Section of Conductor | Normal Diameter of Conductor | Normal Thickness of Insulation | Normal Thickness of | Normal Thickness of Outer Sheath | Approx. | Approx. Net Weight | Max. D.C. Resistance of Conductor at 20 | ||
| Copper Tape | Overall Dia. | Al Conductor | Cu Conductor | Al Conductor | Cu Conductor | ||||
| mm 2 | mm | mm | mm | mm | mm | kg/m | kg/m | Ω/km | Ω/km |
| 25 | |||||||||
| 35 | 6.9 | 5.5 | 0.12 | 1.7 | 24.9 | 0.62 | 0.83 | 0.868 | 0.524 |
| 50 | 8.2 | 5.5 | 0.12 | 1.8 | 26.4 | 0.7 | 0.98 | 0.641 | 0.387 |
| 70 | 9.7 | 5.5 | 0.12 | 1.8 | 27.9 | 0.8 | 1.21 | 0.443 | 0.268 |
| 95 | 11.3 | 5.5 | 0.12 | 1.9 | 29.7 | 0.94 | 1.5 | 0.32 | 0.193 |
| 120 | 12.8 | 5.5 | 0.12 | 1.9 | 31.2 | 1.05 | 1.77 | 0.253 | 0.153 |
| 150 | 14.2 | 5.5 | 0.12 | 2 | 32.8 | 1.17 | 2.07 | 0.206 | 0.124 |
| 185 | 15.9 | 5.5 | 0.12 | 2 | 34.5 | 1.33 | 2.45 | 0.164 | 0.0991 |
| 240 | 18.3 | 5.5 | 0.12 | 2.1 | 37.1 | 1.57 | 3.04 | 0.125 | 0.0754 |
| 300 | 20.4 | 5.5 | 0.12 | 2.2 | 39.4 | 1.81 | 3.66 | 0.1 | 0.0601 |
| 400 | 23.2 | 5.5 | 0.12 | 2.3 | 42.4 | 2.14 | 4.49 | 0.0778 | 0.047 |
| 500 | 26.4 | 5.5 | 0.12 | 2.4 | 46.1 | 2.58 | 5.61 | 0.0605 | 0.0366 |
| 630 | 30.1 | 5.5 | 0.12 | 2.4 | 49.8 | 3.1 | 6.99 | 0.0469 | 0.0283 |
| 5)18/30(36)kV,19/33(36)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable | |||||||||
| Normal Cross Section of Conductor | Normal Diameter of Conductor | Normal Thickness of Insulation | Normal Thickness of | Normal Thickness of Outer Sheath | Approx. | Approx. Net Weight | Max. D.C. Resistance of Conductor at 20 | ||
| Copper Tape | Overall Dia. | Al Conductor | Cu Conductor | Al Conductor | Cu Conductor | ||||
| mm 2 | mm | mm | mm | mm | mm | kg/m | kg/m | Ω/km | Ω/km |
| 25 | |||||||||
| 35 | |||||||||
| 50 | 8.2 | 8 | 0.12 | 2 | 31.8 | 0.95 | 1.23 | 0.641 | 0.387 |
| 70 | 9.7 | 8 | 0.12 | 2 | 33.3 | 1.07 | 1.47 | 0.443 | 0.268 |
| 95 | 11.3 | 8 | 0.12 | 2.1 | 35.1 | 1.21 | 1.78 | 0.32 | 0.193 |
| 120 | 12.8 | 8 | 0.12 | 2.1 | 36.6 | 1.34 | 2.05 | 0.253 | 0.153 |
| 150 | 14.2 | 8 | 0.12 | 2.2 | 38.2 | 1.47 | 2.37 | 0.206 | 0.124 |
| 185 | 15.9 | 8 | 0.12 | 2.2 | 39.9 | 1.64 | 2.76 | 0.164 | 0.0991 |
| 240 | 18.3 | 8 | 0.12 | 2.3 | 42.5 | 1.9 | 3.37 | 0.125 | 0.0754 |
| 300 | 20.4 | 8 | 0.12 | 2.4 | 44.8 | 2.16 | 4.01 | 0.1 | 0.0601 |
| 400 | 23.2 | 8 | 0.12 | 2.4 | 47.6 | 2.52 | 4.87 | 0.0778 | 0.047 |
| 500 | 26.4 | 8 | 0.12 | 2.5 | 51.3 | 2.98 | 6.01 | 0.0605 | 0.0366 |
| 630 | 30.1 | 8 | 0.12 | 2.6 | 55.2 | 3.54 | 7.43 | 0.0469 | 0.0283 |
| 6)3.6/6(7.2)kV,3.6/6.6(7.2)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable | |||||||||
| Normal Cross Section of Conductor | Normal Diameter of Conductor | Normal Thickness of Insulation | Normal Thickness of | Normal Thickness of Outer Sheath | Approx. | Approx. Net Weight | Max. D.C. Resistance of Conductor at 20 | ||
| Copper Tape | Overall Dia. | Al Conductor | Cu Conductor | Al Conductor | Cu Conductor | ||||
| mm 2 | mm | mm | mm | mm | mm | kg/m | kg/m | Ω/km | Ω/km |
| 25 | 6 | 2.5 | 0.1 | 2 | 34.6 | 1.13 | 1.58 | 1.2 | 0.727 |
| 35 | 6.9 | 2.5 | 0.1 | 2.1 | 36.8 | 1.29 | 1.92 | 0.868 | 0.524 |
| 50 | 8.2 | 2.5 | 0.1 | 2.2 | 39.8 | 1.51 | 2.36 | 0.641 | 0.387 |
| 70 | 9.7 | 2.5 | 0.1 | 2.3 | 43.2 | 1.81 | 3.04 | 0.443 | 0.268 |
| 95 | 11.3 | 2.5 | 0.1 | 2.4 | 46.9 | 2.17 | 3.87 | 0.32 | 0.193 |
| 120 | 12.8 | 2.5 | 0.1 | 2.4 | 50.1 | 2.53 | 4.69 | 0.253 | 0.153 |
| 150 | 14.2 | 2.5 | 0.1 | 2.5 | 53.3 | 2.9 | 5.6 | 0.206 | 0.124 |
| 185 | 15.9 | 2.5 | 0.1 | 2.6 | 57.2 | 3.4 | 6.77 | 0.164 | 0.0991 |
| 240 | 18.3 | 2.6 | 0.1 | 2.8 | 63.2 | 4.12 | 8.55 | 0.125 | 0.0754 |
| 300 | 20.4 | 2.8 | 0.1 | 3 | 69 | 4.89 | 10.46 | 0.1 | 0.0601 |
| 400 | 23.2 | 3 | 0.1 | 3.4 | 76.7 | 6.1 | 13.18 | 0.0778 | 0.047 |
| 500 | 26.4 | 3.2 | 0.1 | 3.6 | 85.7 | 8.1 | 16.55 | 0.0605 | 0.0366 |
We are China Medium Voltage XLPE Insulated Unarmoured Power Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular jpcable99 Products
Hot Sale Al Conductor Armored Power Cable
Henan Jiapu Mv Electric 3 Core XLPE Armoured Power Cable
ABC Aerial Bundle Cable/Aluminum Conductor/ Service Drop Wire
22kv Medium Voltage Underground XLPE Power Cable
33kv Aluminium Core XLPE Insulated Unarmoured Power Cable
Popular Unarmoured Cable Products
3 Core Aluminum XLPE /PVC Insulated Unarmoured Power Cable
Low Voltage Multicore XLPE Insualted Unarmoured Power Cable with Ce Certificate
Medium Voltage XLPE Insulated Unarmoured Power Cable
IEC 60502-2 Kabel Xruhakxs 12/20kv Medium Voltage Unarmoured Cable
35 Kv Power Cable 1X500mm2 Cu/XLPE/PVC Unarmoured
Popular XLPE Cable Products
600V XLPE Insualted PVC Sheathed Copper Conductor 4 Core 25sqmm Cu/XLPE/PVC Cable
HDPE Insulated ACSR Conductor 1/0AWG 15kV Tree Wire for Distribution Lines
XLPE Cable Multicore Cable Wires (electrical power cable)
Medium Voltage Swa Armored Electric Power Cable 3.6/6kv-26/35kv
ASTM Standard Overhead Aerial Bundled Cable 4core 35mm2 50mm2 XLPE Aluminum ABC Cable
Flame Resistance Power Cable (ZR-YJV 0.6/1KV)
Popular XLPE Insulated Cable Products
11kv XLPE Insulated Aerial Bundle Cable
Top Quality LV Cable 0.6/1kv Cu/XLPE/Swa/PVC Power Cable
10kv 11kv Aluminum Alloy Conductor XLPE Insulated Aerial Bundle Service Drop Cable
35mm 50mm 70mm Overhead Aluminum Cable
Hot Seller Medium Voltage XLPE Insulated Unarmoured Power Cable
15kv Urd Cable Concentric Full Neutral
Tags: jpcable99, Unarmoured Cable, XLPE Cable, XLPE Insulated Cable