33kv Sz11 Type on-Load Tap Changing Transformers
33kv Sz11 Type on-Load Tap Changing Transformers image
Get Latest Price Request a quote
Quick Details
Product Details
1. Low loss, therefore significantly energy-saving. The average no-load loss is 35% lower, and the load loss 10~20% lower, than
Prescribed by the present National standard GB/T 6451.
2. The core laminations are made up from imported high-quality cold-rolled grain-oriented silicon steel sheets with miter joints
And without punched holes, and are stacked without the upper yoke sheets in place. After stacking, the core is pressed
Integrally and finally glued together by epoxy resin on the cut edges, so that the three limbs and the upper and lower yokes are
Bonded together into a rigid, vertically straightened entity, together with the plate-type upper and lower frame.
3. Zigzag directed flow of oil are provided within the windings, so that all parts of the windings can be cooled more evenly, thus
Reducing the temperature rise of the windings as a whole as well as the hot-spot temperature rise, prolonging the service life
Of transformers.
4. The regulating winding is a separate winding, apart from the high voltage main winding. In this way, total ampere-turn balance
Between windings can be obtained irrespective of the tapping position; And the axial electrodynamic force during short circuit
Can be much reduced, thus upgrading the short circuit withstand capability of the transformer as a whole. All the windings are
Perfectly dried before assembly. The radial clearances between windings and between low voltage winding and core are filled
With pre-dried vertical spacers and insulating cylinders in such a way that the windings are tightly together radially with
Practically ‘zero’ allowance between them.
5. The windings of one phase are assembled into an integral phase block before placing onto the core. The low voltage winding is
Wound directly on strong thick paper cylinder. Vertical spacer strips are provided in spaces between windings and outside the
Outermost winding. The radial dimensions of all windings are kept within strict tolerance, so that a rigid winding phase block
Are obtained, capable of withstanding all the radial short-circuit forces encountered in service, and the possibility of buckling
Of the inner winding is obviated. Axially, the height of all windings is kept within close tolerance. Horizontal spacers between
Discs of a winding are pre-densified. The assembled winding phase black are pressed up and down by single support and
Pressure plates after careful adjustment of the heights of individual windings. Axial pressures are co-ordinated with the
Calculated short circuit force, so that the capability of the transformer to withstand axial short-circuit force is much increased.
6. The winding manufacture, winding assembly, and core and winding assembly work are all proceeded in totally closed clean
Rooms inside workshops. The cleanliness and temperature stability requirement of the area are the same as that required for
The manufacture of 500kV class transformers. The final vapor phase drying of the core and coil assembly is practically a further
Cleaning process.
7. Core frames in the form of a flat plate are used for clamping the core, and are joined together by side beams. The core and coil
Assembly is fixed in the tank, being positioned against the tank at six sides rigidly, such that there can be no displacement of
The assembly due to impacts during transport. Three-dimensional impact recorders are installed on transformers during
Transport to detect whether or not unacceptable impact force has been experienced and displacement of the core and coil
Assembly occurred during transportation. If not, lifting of the core and coil assembly out of the tank is not necessary. Flat cover
Permits the bushings to be mounted in a vertical positi
We are China 33kv Sz11 Type on-Load Tap Changing Transformers manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Amorphous Transformer Products
Single-Phase Pole Overhead Conventional Mounted Distribution Transformer
Three-Phase 33kv off-Circuit Tap Changing Power Transformers with Low-Loss and Low-Noise
Three Phase 33kv Tap Changer Power Transformers
11-24kv Dry-Type Transformer Dimensions with Protection Enclosure
11kv Step Voltage Regulator Voltage Stabilizer
11kv Sc (H) B11-630~2500kVA Distribution Transformers
Popular Oil Transformet Products
33kv Rectifier Special Transformer Power Transformer
33kv and Below Rectifier Special Distribution Transformer
Traction Transformer Tap Changing Oltc 33kv
Step Voltage Regulator Oil Immersed
Medium Voltage Dry Type Distribution Transformers 33kv
Micro Power Pole Mounted Distribution Transformer 100kVA
Popular Power Transformer Products
Oil Immersed Distribution Transformer 24kv IEC Standard
66kv and 69kv Rectifier Special Transformer Manufacture
11kv 250-2500kVA on-Load Tap-Changer Distribution Transformer
Three Phase Overhead Pole Mounted Distribution Transformer
DIN DT 1/1000A Completed Transformer Bushing Transformer Components
Popular silverstone-electric Products
33kv S11 Type off-Circuit Tap Changing Transformers
33kv Arc Furnace Transformer OEM Special Power Transformer
Manufacture 630~3150kVA 11kv Electronic Transformer
Pad Mount Three Phase Dead Front ANSI Type Transformer Enclosure
Dry Type Distribution Transformer 11kv
24kv Composite Insulator for Transformer Substation
Tags: Amorphous Transformer, Oil Transformet, Power Transformer, silverstone-electric