LV Stay Rod (M12mm) with Nut and Washer

China 
                        LV Stay Rod (M12mm) with Nut and Washer
                      manufacture and supplier

LV Stay Rod (M12mm) with Nut and Washer image

Get Latest Price Request a quote

Quick Details

LV Stay Rod (M12mm) with Nut and Washer

M12-2000

Pull-Line Fitting

Line Fittings

IEC BS

Cold Pressing

China Suizhou

7318159001

Product Details

Stay rod for LV

3.16.1 Standard
Any Standard which fits our design requirements is acceptable.
3.16.2. Material
* To protect corrosion stay rod shall be well hot dip-galvanized.
3.16.3. Guaranteed Value
The following values are guaranteed by the manufacturers as stipulated by the guaranteed characteristics table
* Each and every dimension according to the given drawing.
3.16.4 Testing
The following testing shall be carried out.
           a.   Visual inspection
           b. Size inspection.
           c.    Galvanizing test

3.1  Stay plate for MV
3.15.1 Standard
Any Standard which fits our design requirements is acceptable.
3.15.2. Material
* To protect corrosion stay plate shall be well hot dip-galvanized.
3.15.3. Guaranteed Value
The following values are guaranteed by the manufacturers as stipulated by the guaranteed characteristics table
* Each and every dimension according to the given drawing.
3.15.4 Testing
The following testing shall be carried out.
           a.   Visual inspection
           b. Size inspection.
           c.    Galvanizing test

3.1  Stay plate for LV
3.14.1 Standard
Any Standard which fits our design requirements is acceptable.
3.14.2. Material
* To protect corrosion stay plate shall be well hot dip-galvanized.
3.14.3 Guaranteed Value
The following values are guaranteed by the manufacturers as stipulated by the guaranteed characteristics table
* Each and every dimension according to the given drawing.
3.14.4 Testing
The following testing shall be carried out.
           a.   Visual inspection
           b. Size inspection.
           c.    Galvanizing test

     M16, 400mm long bolt nut and washer 
3.12.1. Standard
BS 4190 or equivalent is acceptable.
3.12.2. Design
Long bolt nominal diameter (d) 16 mm and lead 2.
Minor threaded diameter (dk) 14mm.
Thickness of head (k) as per BS standard
The nut shall fit long bolt threaded diameter.
Thickness of nut head (m) as per BS standard
Width of head across flats (s) as per BS standard.
Width of head across angle (e) as per BS standard
Washer diameter (d1) as per BS standard.
Thickness of washer as per BS standard.
Inside diameter of washer (h) as per  BS standard
To protect corrosion long bolt shall be well hot dip-galvanized.
3.12.3. Guaranteed Value
The following values are guaranteed by the manufacturers as stipulated by the guaranteed characteristics table
* Threads of long bolt shall be according to the design dimension.
* Each and every dimension according to the given drawing.
3.12.4 Testing
The following testing shall be carried out.
           a.   Visual inspection
           b. Size inspection
           c.    Galvanizing test

3.1   M16, 300mm long bolt nut and washer 
3.11.1 Standard
BS 4190 or equivalent is acceptable.
3.11.2 Design
Long bolt nominal diameter (d) 16 mm and lead 2.
Minor threaded diameter (dk) 14mm.
Thickness of head (k) as per BS standard
The nut shall fit long bolt threaded diameter.
Thickness of nut head (m) as per BS standard
Width of head across flats (s) as per BS standard.
Width of head across angle (e) as per BS standard
Washer diameter (d1) as per BS standard.
Thickness of washer as per BS standard.
Inside diameter of washer (h) as per  BS standard
To protect corrosion long bolt shall be well hot dip-galvanized.
3.11.3. Guaranteed Value
The following values are guaranteed by the manufacturers as stipulated by the guaranteed characteristics table
* Threads of long bolt shall be according to the design dimension.
* Each and every dimension according to the given drawing.
3.11.4 Testing
The following testing shall be carried out.
           a.   Visual inspection
           b. Size inspection
           c.    Galvanizing test

3.1 Earthing Rod with Clamp
Profiled earthing rods of hot dip galvanized steel with connecting lugs. Cross-section and length of profile shall be 50x50x3 mm and 3 m long, respectively. The earthing rod should also be in accordance with the corresponding drawing of this tender.
Earthing rod clamps suitable for stranded copper conductor of 25-35 mm2.
 
3.10.1 Guaranteed Value
 
The following values are guaranteed by the manufacturers as stipulated by the guaranteed characteristics table
* Each and every dimension according to the given drawing.
 
3.10.2. Testing
 
The following testing shall be carried out.
 
           a.   Visual inspection
           b. Size inspection
           c.    Galvanizing test

 Standard :BS or equivalent is acceptable.
 Design
– Small collar nominal diameter (d) 12 mm and lead 2.
– Minor threaded diameter (dk) 10mm.
– Thickness of head (k) as per BS standard
– The nut shall fit small collar threaded diameter.
– Thickness of nut head (m) as per BS standard
– Width of head across flats (s) as per BS standard.
– Width of head across angle (e) as per BS standard
– Washer diameter (d1) as per BS standard.
– Thickness of washer as per BS standard.
– Inside diameter of washer (h) as per  BS standard
To protect corrosion small collar shall be well hot dip-galvanized.
3.13.3 Guaranteed Value
The following values are guaranteed by the manufacturers as stipulated by the guaranteed characteristics table
* Threads of small collar shall be according to the design dimension.
* Each and every dimension according to the given drawing.
3.13.4. Testing
The following testing shall be carried out.
           a.   Visual inspection
           b. Size inspection
           c.   Galvanizing test
 Big collar, type 2
Standard

BS or equivalent is acceptable.
 Design
– Big collar nominal diameter (d) 16 mm and lead 2.
– Minor threaded diameter (dk) 14mm.
– Thickness of head (k) as per BS standard
– The nut shall fit big collar threaded diameter.
– Thickness of nut head (m) as per BS standard
– Width of head across flats (s) as per BS standard.
– Width of head across angle (e) as per BS standard
– Washer diameter (d1) as per BS standard.
– Thickness of washer as per BS standard.
– Inside diameter of washer (h) as per  BS standard
To protect corrosion big collar shall be well hot dip-galvanized.
. Guaranteed Value
The following values are guaranteed by the manufacturers as stipulated by the guaranteed characteristics table
* Threads of big collar shall be according to the design dimension.
* Each and every dimension according to the given drawing.
 Testing
The following testing shall be carried out.
 
           a.   Visual inspection
           b. Size inspection
           c.    Galvanizing test

Tie Strap
The strap shall have a cross section dimension of 50 x 5 mm
The strap shall have a cross section dimension of 50 x 5 mm.
The strap manufactured for suspension/intermediate assembly according to the given drawing (see the drawing)
Yield strength of tie strap must be 240N/mm2.
To protect tie strap from corrosion it shall be hot dip-galvanized.

Guaranteed Value
The following values are guaranteed by the manufacturers as stipulated by the guaranteed characteristics table
§ Each and every dimension
§ Material strength.
3.7.4. Testing
The following testing must be carried out.
a. Visual inspection
b. Size and dimension verification.
 U channel cross-arm for 33kV

Any standard equivalent to GB/T 707 1988, 80×43, 5/8 and 100×48, 5.3/8.5 is accepted.
For suspension, T-off, angle and dead end assembly shall have a cross section dimension of
80 x 43 x 5/8mm
For transformer base U-cross arms shall have a  dimension of 100x48x5.3/8.5
U-cross arms manufactured for suspension, T-off, angle, dead end and transformer base
assembly as per the drawing
To protect U-cross arms against corrosion U-cross arms shall be hot dip-galvanized
Yield strength of U-cross arm 240N/mm2

Test for ultimate tensile strength
 Test for yield stress
 Percentage elongation test
Bend test
 Chemical composition test
 Galvanization tests thickness of  Zn coating
 Weight of Zn Coating
 Uniformity of Zn coating
 Adhesion test of Zn coating
 Visual inspection
Weight verification
 

Dead end hook 382
Hook threaded nominal diameter (A) 16mm
Minor threaded diameter (W) 14
Thickness of nut (M), washer diameter and thickness as per BS standard
Yield strength of pin must be 240N/mm2
LV Hook from corrosion it shall be hot dip-galvanized
Visual inspection
Size inspection
 Galvanizing test
Strength test

Suspension hook M16-380
Hook threaded nominal diameter (A) 16mm
Minor threaded diameter (W) 14
Thickness of nut (M), washer diameter and thickness as per BS standard
Yield strength of pin must be 240N/mm2
To protect LV Hook from corrosion it shall be hot dip-galvanized
Testing
Visual inspection
Size inspection
Galvanizing test
Strength test

The following testing shall be carried out

Dead End Clamp ,Anchoring Clamp

The clamps should be designed to Anchor LV AB cable with insulated messenger. The clamp
should anchor/hold the neutral messenger without damaging the insulation.
The clamp should conform to the standard NFC 33041 and 33042 or equivalent. The clamp
body should be made of corrosion resistant Aluminium alloy, bail should be of stainless steel
and self adjusting wedges should be weather and UV resistant polymer.

Anchoring assemblies are used to firmly attach the messenger of ABC to a support and
transmit the mechanical tension at the end of a run or to the supporting structures at a major
change in direction.
 

neutral messenger should be fixed by an adjustable grip device.
The suspension clamp shall be manufactured from weather and UV light resistant reinforced

nylon and aluminum alloy. The clamp should provide an additional insulation between the
cable and the pole.
Clamps should be fixed with pole by eyehook/bracket. Breaking load should not be less than
15kN
Suspension Assembly is used for supporting an ABC by installation on the messenger at an

intermediate point of support such as a pole. It can accommodate small angles of deviation up
to 30o. The clamp should hold insulated messenger of diameter range from 6mm up to 12 mm.
Visual examination
Dimensional and material verification
Tensile strength
Dielectric voltage test
Climatic & corrosion ageing
Endurance test under mechanical and thermal stresses
Electrical ageing
 

TYPE:APG-C4
NAME:Parallel groove clamp APG-C4
Specification
 

Material
 
   
Material standard
 
   
Range of conductor cross-section
 
16…50/2.5…35
 
 
Range of conductor diameter, Al/Cu
 
mm2
 
 
Tensile strength
 
KN 5
Thickness of zinc coating,
 
mm
 
43
Test voltage at 50Hz for one minute in water
 
kV
 
6

  Al 35-300mm²     Size 105*65mm  Tri-bolts  Bolt M10*60  Weight 560g

We are China LV Stay Rod (M12mm) with Nut and Washer manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular Anchoring Clamp Products

Dead End Hook 430/Pigtail Hook

Full Tension Aerial Cable Clamp (DR1500) 35-70mm2

Tension Clamps (ODWAC-15/ODWAC-22)

Low Voltage ABC Suspension Clamp

High Tension Electric Wire Conductor Anchor Clamp

Strain Clamps (NLL series)

Popular Earth Rod Products

Copperweld Steel Earth Rod/Ground Rod

Earth Rod Er-16X1800

Power Fittings Copper Bonded Ground Rod Earth Rod Grounding Material

Copper Clad Earth Rod Ground Rod

Earthing Flexible Ground Rod Connector for 16*1.5

Copper Threaded Earth Rod

Popular jgtrade1 Products

Polymer Fuse Cutout, Drop out Fuses 6kv 100A

Nitrile Gloves, Safety Cuffnitrile Fully Coatedblue 7-11

Pcv Gloves with Long Sleeve Smooth/Sandy Finish Blue 60cm

D O Light Fuse Outcut

Composite Insulator 70kn - BS11- 24kv

High -Voltage Isolate Switch 24kv 630A

Popular Stay Rod Products

8FT X 3/4'' Hot DIP Galvanized Steel Stay Rod

Pole Line Hardware Galvanized Stay Rod M20

Power Fittings Hot-DIP Galvanized Stay Rod Stay Assembly Accessories

Terminal Strip, Yoke Plate, Connecting Plate

Insulation Piercing Clamp 25-75sqmm

Top Quality Stay Rod

Tags: , , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION