High Voltage Line Type ZnO Lightning Arrestors Yh10W-15
High Voltage Line Type ZnO Lightning Arrestors Yh10W-15 image
Get Latest Price Request a quote
Quick Details
Product Details
0.28kV~500kV Surge Arresters’ Characteristics:
1. The Core column applied winding structure, Polymer Housed core pillar molded on the core column, with almost no internal air gap, and outstanding sealing performance Simple in structure, small in size and light in weight.
2. Polymer Housed with silicone rubber, explosion-proof ZnO varistor as the core component is large
in flow capacity.
3. International standard IEC 60099-4 and ANSI 62.22, and with high reliability. With fully insulated tops, the product can be applied to the complete cabinet installation, which can reduce the designing size of cabinet.
4. Products with detachment device can provide signals for quitting operation when failure occurs,
avoiding arrester explosion, and it is maintenance-free.
5. Polymer housed products with a six CTI level, creepage distance meets the requirements of IV level in heavy pollution areas.
Technical Parameters:
| Type | YH10W5-15/41.2 | 4/10µS High current impulse kA | 100 |
| Rated voltage———kV | 15 | Lightning impulse withstand kV | 110 |
| MCOV —————-kV | 12.7 | Power frequency voltage withstand(dry/wet)kV | 28 |
| Nominal Current——-kA | 10 | 0.1S TOV————–kV | 18 |
| Residual voltage of steep impulse—-at 5kA(kV) | 44.5 | 1S TOV—————-kV | 17.25 |
| 8/20µS Residual voltage of lightning impulse current kV(Peak value)—–at 5kA(kV) | 41.2 | 10S TOV—————kV | 16.5 |
| Residual voltage of switching impulse current kV (peak value)—-at 1kA (kV) | 31.5 | 1200S TOV————-kV | 15 |
| 1mA D.C reference voltage (kV) | 21.2 | Creepage distance —-mm | 500 |
| Line discharge level | 1 | Material employed in series non-linear resistor | Zinc Oxide |
| 2mS long duration impulse current A | 400 | Material of housing | silicone rubber |
Working condition:
| Environment temperature: -40–+40 degree | |||||||
| altitude:<1000m | |||||||
| 48HZ<Rated frequency<62HZ | |||||||
| Power frequency voltage should not be more than continuous running voltage | |||||||
| Max wind speed should be less than 35m/s | |||||||
| Earthquake intensity should be less than 7 degree | |||||||
| If used in contamination area, should be noted in advance. |
Line discharge level from 1 to 5,
We are China High Voltage Line Type ZnO Lightning Arrestors Yh10W-15 manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular hzyddq Products
132kv Polymer Gray Red Surge Arrester
Lightning Protector SPD Lighting Arrester
Silicon Rubber High Voltage Insulator
Hpd 33-36kv Fuse Cutout for Power Transmission
Composite Suspension Lightning Arrester of Disconnector
Building Composite Housing Gapless Arrester Lightning in The Phillippines
Popular Lightning Arrester Products
27kv High Quality Oxide Zinc Lightning Arrester for Substation
36kv 10ka Polymer Housed Gapless Surge Arrester
3-36kv Polymeric Lightning Arresters/Surge Arrester with Gap &Gap-Less Polymer Housed
Loadbreak Cutout with Arc Chute Type Interrupter 35kv
Composite Surge Lighting Arrester Manufacturer
Popular Surge Arrester Products
220kv Silicon Type Surge Arrester CMA10WS-216/562
12kv Power Station Caremic Housing Lighting Arrester
Electric Porcelain Housed 120kv Surge Arrester Without Gap
Polymer Surge Arrester Pointed End Head
30kv High Voltage Surge Arrester for Distribution Line
Popular Surge Arresters Products
Outdoor Station Type 11kv-220kv Polymeric Lightning Arrester (type test)
Polymeric Housed Zinc Oxide Lightning Surge Arresters Series
5kv 10kv 10ka Composite Silicon Rubber Zinc Oxide Surge Arresters
(3-36KV) Polymeric Housed Zinc Oxide Lightning Arresters Without Gaps
33kv Polymeric Zinc Oxide Type Lightning Surge Arresters
L&R 15kv 10ka Surge Protector Lightning Arrester
Tags: hzyddq, Lightning Arrester, Surge Arrester, Surge Arresters