High Voltage Line Type ZnO Lightning Arrestors Yh10W-15
High Voltage Line Type ZnO Lightning Arrestors Yh10W-15 image
Get Latest Price Request a quote
Quick Details
Product Details
0.28kV~500kV Surge Arresters’ Characteristics:
1. The Core column applied winding structure, Polymer Housed core pillar molded on the core column, with almost no internal air gap, and outstanding sealing performance Simple in structure, small in size and light in weight.
2. Polymer Housed with silicone rubber, explosion-proof ZnO varistor as the core component is large
in flow capacity.
3. International standard IEC 60099-4 and ANSI 62.22, and with high reliability. With fully insulated tops, the product can be applied to the complete cabinet installation, which can reduce the designing size of cabinet.
4. Products with detachment device can provide signals for quitting operation when failure occurs,
avoiding arrester explosion, and it is maintenance-free.
5. Polymer housed products with a six CTI level, creepage distance meets the requirements of IV level in heavy pollution areas.
Technical Parameters:
Type | YH10W5-15/41.2 | 4/10µS High current impulse kA | 100 |
Rated voltage———kV | 15 | Lightning impulse withstand kV | 110 |
MCOV —————-kV | 12.7 | Power frequency voltage withstand(dry/wet)kV | 28 |
Nominal Current——-kA | 10 | 0.1S TOV————–kV | 18 |
Residual voltage of steep impulse—-at 5kA(kV) | 44.5 | 1S TOV—————-kV | 17.25 |
8/20µS Residual voltage of lightning impulse current kV(Peak value)—–at 5kA(kV) | 41.2 | 10S TOV—————kV | 16.5 |
Residual voltage of switching impulse current kV (peak value)—-at 1kA (kV) | 31.5 | 1200S TOV————-kV | 15 |
1mA D.C reference voltage (kV) | 21.2 | Creepage distance —-mm | 500 |
Line discharge level | 1 | Material employed in series non-linear resistor | Zinc Oxide |
2mS long duration impulse current A | 400 | Material of housing | silicone rubber |
Working condition:
Environment temperature: -40–+40 degree | |||||||
altitude:<1000m | |||||||
48HZ<Rated frequency<62HZ | |||||||
Power frequency voltage should not be more than continuous running voltage | |||||||
Max wind speed should be less than 35m/s | |||||||
Earthquake intensity should be less than 7 degree | |||||||
If used in contamination area, should be noted in advance. |
Line discharge level from 1 to 5,
We are China High Voltage Line Type ZnO Lightning Arrestors Yh10W-15 manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular hzyddq Products
Thunder Arrester Polymeric Housed Gapless Lightning Arrestor up to 550kv
High Voltage Electrical Porcelain Surge Arrester with Cap
145kv China Outdoor Semi Pantorgraph Disconnector Switch
Silicon Rubber Suspension Composite Insulator
132kv High Voltage Surge Protector
Hight-Voltage Gw4 10~252kv Disconnector Switch
Popular Lightning Arrester Products
Hot Sale Surge Lightning 24kv Arrester High Voltage Arrestor Arresters
Polymer Gapless Surge Arester Lightning Arrester
Lightning Arrester, Surge Arrester, Pararrayos, Parafoudre 3-132KV, 10KA
42kv Silicone Polymer Housing Composite Metal Oxide Lightning Arrester
Popular Surge Arrester Products
Supply Oxide Gapless Lightning 11kv Polymeric Surge Arrester
24kv 33kv Composite Znic-Oxide Arrester with Disconnector and Mounting Bracket
High Voltage Polymer Ceramic Porcelain ZnO Surge Arrester 120kv
MOV Metal-Oxide Lightning Arrester/ Surge Arrester (YH5W)
(YH10W-66) Polymeric Housed Metal-Oxide Surge Arrester
Popular Surge Arresters Products
11kv Composite Surge Protector Lightning Arrester
Station Class Ceramic Housed Gapless ZnO Arresters
220kv Substation Gapless Metal-Oxide Surge Arrestors with Disconnector 33kv
Power Transmission Type 110kv 10ka ZnO Surge Protector Moa Surge Diverters
24kv/10ka Polymeric Housed Zinc Oxide Surge Arrester
Kema Lighting Arrest Surge Lightning Arrester for Substation
Tags: hzyddq, Lightning Arrester, Surge Arrester, Surge Arresters