High Voltage Substation Lightning Arresters Manufacturers of 66kV Surge Arrester
0.25kV~750kV Surge Arresters’ Characteristics:
1. The Core column applied winding structure, Polymer Housed core pillar molded on the core column, with almost no internal air gap, and outstanding sealing performance Simple in structure, small in size and light in weight.
2. Polymer Housed with silicone rubber, explosion-proof ZnO varistor as the core component is large
in flow capacity.
3. International standard IEC 60099-4 and ANSI 62.22, and with high reliability. With fully insulated tops, the product can be applied to the complete cabinet installation, which can reduce the designing size of cabinet.
4. Products with detachment device can provide signals for quitting operation when failure occurs,
avoiding arrester explosion, and it is maintenance-free.
5. Polymer housed products with a six CTI level, creepage distance meets the requirements of IV level in heavy pollution areas.
Surge Arresters’ Technical Parameters:
| Type | Y10W5-66/176 |
| Rated voltage———kV | 66 |
| MCOV —————-kV | 52.8 |
| Nominal Current——-kA | 10 |
| Residual voltage of steep impulse—-at 5kA(kV) | 221 |
| 8/20μS Residual voltage of lightning impulse current kV(Peak value)—–at 5kA(kV) | 178 |
| Residual voltage of switching impulse current kV (peak value)—-at 1kA (kV) | 137 |
| 1mA D.C reference voltage (kV) | 96 |
| Line discharge level | 1 |
| 2mS long duration impulse current A | 400 |
| 4/10μS High current impulse kA | 100 |
| Lightning impulse withstand kV | 325 |
| Power frequency voltage withstand(dry/wet)kV | 140 |
| 0.1S TOV————–kV | 79.2 |
| 1S TOV—————-kV | 75.9 |
| 10S TOV—————kV | 72.6 |
| 1200S TOV————-kV | 66 |
| Creepage distance —-mm | 2500 |
| Material employed in series non-linear resistor | Zinc Oxide |
| Working condition: | Environment temperature: -40–+40 degree | |||||||
| altitude:<1000m | ||||||||
| 48HZ<Rated frequency<62HZ | ||||||||
| Power frequency voltage should not be more than continuous running voltage | ||||||||
| Max wind speed should be less than 35m/s | ||||||||
| Earthquake intensity should be less than 7 degree | ||||||||
| If used in contamination area, should be noted in advance. | ||||||||
Lightning Arresters Production:
We are China Brown Surge Protector Arrester manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Arrester Products
Ruitian Network Silicone Rubber 10kv 350mm Lightning Arrester
Low Price Polymer 24kv Lightning Arrester
Yh5w-33 Composite Lighting Surge Arrester
Conwell Manufacturer 9kv Silicone 9kv Surge Arrester
Zinc Oxide Grey High Capacity Lightning Arrester
Durable Outdoor Compound 36kv Zinc-Oxide Surge Protector Lightening Arrester
Popular hzyddq Products
High Voltage Electrical Porcelain Surge Arrester with Cap
Hangzhou Substation Type Rated Voltage 3-36kv Composite Housed Surge Protectors
High Quality Chinese Surge Arresters
Included Disconnector Bracket Composite Arrestor 10ka, 36kv for Substation
OEM Lighting Arrester Protective Device 36kv Composite Lightning Arrestor
Active Lightning Arrester Surge Protection Device
Popular Surge Arrester Products
Rated Voltage 110kv Mcov 86kv Porcelain Ceramic Housed Lightning Arrestor
36kv Building Air Terminal Metal Oxide Composite Arrester
36kv High Voltage Lightning Protector Surge Arrester
Yh5w-36 Composite/Polymeric/Silicone Rubber Surge Arrester
Popular Surge Protector Products
Metal Oxide Surge Arrester Surge Arrester Lightning Protector
18kv Substation Surge Protector Composite Lightning Arrester for Power Station
Insulator SPD Surge Protector Arrester
Electrical Equipment 9kv/11kv Medium Voltage Metal Oxide ZnO Surge Arrester
Heavy Electrical Equipment Substation Polymeric Lightning Arrester Hoop
35~220kv Silicon Rubber Single Phase Lightening Arrester for Transmission Line
Tags: Arrester, hzyddq, Surge Arrester, Surge Protector