High Voltage Line Disconnecting Switch with Earthing Switch
High Voltage Line Disconnecting Switch with Earthing Switch image
Get Latest Price Request a quote
Quick Details
Product Details
1. V – 90 degrees, force equilibrium stability, cover an area of an area small
2. The conductive loop for the modular structure, flow stability, change the simple
Cancel the old product structure of bevel gear (3) base, to the universal connecting rod drive patent structure, convenient operation
4. Bearing seat is made from high strength steel, the height is adjustable
5. A variety of installation
Drawing
| Parameter Table | |||||
| No | Items | Technical parameter | |||
| 1 | Rated Voltage kV | 72.5 | 126 | ||
| 2 | Nominal system voltage kV | 66 | 110 | ||
| 3 | Rated current A | 630;1250;1600;2000;2500;3150;4000 | |||
| 4 | Rated Short Time withstand current and Time kA/s | 25~50/4 | |||
| 5 | Rated Peak withstand current kA | 63~125 | |||
| 6 | 1min power frequency withstand voltage (effective value) kV | To earth | 140 | 230 | |
| To phase | 140 | 2300 | |||
| Across Isolating DS | 180 | 230+70 | |||
| 7 | Lightning Impulse wishstand voltage(peak value) KV | To earth | 325 | 550 | |
| To phase | 325 | 500 | |||
| Across Isolating DS | 385 | 550+100 | |||
| 8 | Rated mechanical terminal load N | Level of lateral load | 750 | 1500 | |
| Level of vertical load | 500 | 1000 | |||
| Vertical | 750 | 1000 | |||
| 9 | The min distance of insulation against ground mm | 600 | 1000 | ||
| 10 | Max Man Operative Moment N. m | 200 | |||
| 11 | Motor Drive operating mechanism control voltage V | AC220,380; DC110,220 | |||
| 12 | Motor Drive operating mechanism motor voltage V | AC220,380; DC110,220 | |||
We are China High Voltage Line Disconnecting Switch with Earthing Switch manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular hzyddq Products
Power Distribution Equipment Mini 12V Surge Protection Device
Kema Surge Arresters Supplierssurge Arrester Lightning Protector
Housed Metal Oxide 132kv Porcelain Surge Arrester
Zinc Oxide Block/ZnO Varistor for Surge Arrester
10kv 11kv 15kv 20kv Disconnect Switch Load Isolation Switch (gw9)
Rated Voltage 110kv Mcov 86kv Porcelain Ceramic Housed Lightning Arrestor
Popular Substation Products
Zbm3-40.5 Combined Transformer Substation 40.5kv
Steel Composite Plate Series Box-Type Transformer Substation Enclosure
Seccionador Tripolar, Break Isolator, Substation
Zbw17 (YB) -10 Transformer Substation Power Substation Substation
Popular Transformer Products
S11-M-20/30~2500kVA Three Phase Double Winding 20kv Distribution Transformers Power Transformer
SFP10 220kv Hight Voltage Generator Power Transformer
Small Oil-Immersed Transformer Key Solution for Metro with UL
Popular V-Type Products
Gw5 V-Type High Voltage Line Disconnecting Switch with Earthing Switch
V-Type High Voltage Line Disconnecting Switch with Earthing Switch
Tags: hzyddq, Substation, Transformer, V-Type