1. V – 90 degrees, force equilibrium stability, cover an area of an area small
2. The conductive loop for the modular structure, flow stability, change the simple
Cancel the old product structure of bevel gear (3) base, to the universal connecting rod drive patent structure, convenient operation
4. Bearing seat is made from high strength steel, the height is adjustable
5. A variety of installation
Drawing
| Parameter Table | |||||
| No | Items | Technical parameter | |||
| 1 | Rated Voltage kV | 72.5 | 126 | ||
| 2 | Nominal system voltage kV | 66 | 110 | ||
| 3 | Rated current A | 630;1250;1600;2000;2500;3150;4000 | |||
| 4 | Rated Short Time withstand current and Time kA/s | 25~50/4 | |||
| 5 | Rated Peak withstand current kA | 63~125 | |||
| 6 | 1min power frequency withstand voltage (effective value) kV | To earth | 140 | 230 | |
| To phase | 140 | 2300 | |||
| Across Isolating DS | 180 | 230+70 | |||
| 7 | Lightning Impulse wishstand voltage(peak value) KV | To earth | 325 | 550 | |
| To phase | 325 | 500 | |||
| Across Isolating DS | 385 | 550+100 | |||
| 8 | Rated mechanical terminal load N | Level of lateral load | 750 | 1500 | |
| Level of vertical load | 500 | 1000 | |||
| Vertical | 750 | 1000 | |||
| 9 | The min distance of insulation against ground mm | 600 | 1000 | ||
| 10 | Max Man Operative Moment N. m | 200 | |||
| 11 | Motor Drive operating mechanism control voltage V | AC220,380; DC110,220 | |||
| 12 | Motor Drive operating mechanism motor voltage V | AC220,380; DC110,220 | |||
We are China V-Type High Voltage Line Disconnecting Switch with Earthing Switch manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular hzyddq Products
Zinc Oxide Arrester/Substation Surge Arrestor
Power Transmission Line Equipment Mini Lower Voltage 12V Surge Protector
10ka/ 5ka Gapless Lighting Arrest 21kv Moa Surge Diverter
27kv 5ka Silicon Rubber Lightning Arrester for Substation
420kv Power Station Type Electric Polymer Housing Surge Arrester
Outdoor Class2 Hv Polymer Ceramic Porcelain Zinc Oxide Surge Arrester
Popular Substation Products
Substation Cabinet Substation Box/Enclosure
Tightening Clamp That Connects The Truss to The Pole
Zbw20 (JBW) -12 Series Fully-Sealed Impact Prefabricated Substation
Zbw17 (YB) -10 Transformer Substation Power Substation Substation
Popular Transformer Products
Environmental Friendly Oil-Immersed Transformer Key Solution for Metro
Lzzbj9-10 10kv Post Type Casting Insulation Current Transformer
Lzzbj9-7.2 Current Transfomer for Mv Switchgear, Voltage Transformer, Measurement Transformer
Environmental Friendly Wound Core Dry Type Transformer Key Solution for Metro with UL
Three-Phase Oil-Immersed Distribution /Earthing/ Grounding / Power Transformer
Energy-Saving Wound Core Oil-Immersed Auto Transformer Key Solution for Transportation
Popular V-Type Products
High Voltage Line Disconnecting Switch with Earthing Switch
Gw5 V-Type High Voltage Line Disconnecting Switch with Earthing Switch
Tags: hzyddq, Substation, Transformer, V-Type