Surge Protection Insulator SPD Arrester
Surge Protection Insulator SPD Arrester image
Get Latest Price Request a quote
Quick Details
Product Details
High Voltage Substation Lightning Arresters Manufacturers of 66kV Surge Arrester
0.25kV~750kV Surge Arresters’ Characteristics:
1. The Core column applied winding structure, Polymer Housed core pillar molded on the core column, with almost no internal air gap, and outstanding sealing performance Simple in structure, small in size and light in weight.
2. Polymer Housed with silicone rubber, explosion-proof ZnO varistor as the core component is large
in flow capacity.
3. International standard IEC 60099-4 and ANSI 62.22, and with high reliability. With fully insulated tops, the product can be applied to the complete cabinet installation, which can reduce the designing size of cabinet.
4. Products with detachment device can provide signals for quitting operation when failure occurs,
avoiding arrester explosion, and it is maintenance-free.
5. Polymer housed products with a six CTI level, creepage distance meets the requirements of IV level in heavy pollution areas.
Surge Arresters’ Technical Parameters:
Type | Y10W5-66/176 |
Rated voltage———kV | 66 |
MCOV —————-kV | 52.8 |
Nominal Current——-kA | 10 |
Residual voltage of steep impulse—-at 5kA(kV) | 221 |
8/20μS Residual voltage of lightning impulse current kV(Peak value)—–at 5kA(kV) | 178 |
Residual voltage of switching impulse current kV (peak value)—-at 1kA (kV) | 137 |
1mA D.C reference voltage (kV) | 96 |
Line discharge level | 1 |
2mS long duration impulse current A | 400 |
4/10μS High current impulse kA | 100 |
Lightning impulse withstand kV | 325 |
Power frequency voltage withstand(dry/wet)kV | 140 |
0.1S TOV————–kV | 79.2 |
1S TOV—————-kV | 75.9 |
10S TOV—————kV | 72.6 |
1200S TOV————-kV | 66 |
Creepage distance —-mm | 2500 |
Material employed in series non-linear resistor | Zinc Oxide |
Working condition: | Environment temperature: -40–+40 degree | |||||||
altitude:<1000m | ||||||||
48HZ<Rated frequency<62HZ | ||||||||
Power frequency voltage should not be more than continuous running voltage | ||||||||
Max wind speed should be less than 35m/s | ||||||||
Earthquake intensity should be less than 7 degree | ||||||||
If used in contamination area, should be noted in advance. |
Lightning Arresters Production:
We are China Surge Protection Insulator SPD Arrester manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Arrester Products
10ka Polymer Housed Lightning Arrester Yh10W-36kv
Rated Voltage 132kv 10ka Porcelain Housing Lighting Arrester
11kv Composite Polymeric Surge Arrester Lightning Protector
High Voltage 35kv Station Surge Arrester
SPD Surge Protector Device Arrester
Surge Protector Lightning Arrester Lightning Arrester
Popular hzyddq Products
Power Transmission Line Equipment 6 Kv Surge Arrestors
Lighting Arrester Class 1/5ka Nominal Current/China Professional Manufacture
Lightning Arrester Without Gaps Transmission Line Surge Protector
Professional Thunder Surge Arresters Manufacturer
Power Transmission Type 110kv 10ka ZnO Surge Protector Moa Surge Diverters
Pd4 (15-27kV) Chinese Mv Fuse Cutout
Popular Surge Arrester Products
Hy1.5W-0.28kv Zinc-Oxide Arrester
Electrical Equipments 110kv - 750kv Substation Porcelain Ceramic Gapless Surge Arrester
Lightning Arrester 10 Ka Type Metal Gapless Oxide 11kv
Electrical Equipment Supplies About Advanced German Tech Polymeric Arrestor
Sleeve; Alum Tube Service Ysu 2W 4W
Popular Surge Protector Products
Substation Surge Arrester 132kv 66kv 275kv
Gray Brown Surge Protector Arrester
Hv Porcelain Ceramic Gapless Zinc Oxide Lightning Surge Arresters
15kv Silicon Rubber Housed Metal Oxide Gapless Surge Arrestors
Lightning Protection Zinc Oxide Varistors Lightning Arrester with Porcelain Insulator
18kv Metal Oxide Surge Protector Arrester for Outdoor
Tags: Arrester, hzyddq, Surge Arrester, Surge Protector