Innvoation Electrical Station Class Porcelain Surge Arrestors
Innvoation Electrical Station Class Porcelain Surge Arrestors image
Get Latest Price Request a quote
Quick Details
Product Details
0.28kV~500kV Surge Arresters’ Characteristics:
1. The Core column applied winding structure, Polymer Housed core pillar molded on the core column, with almost no internal air gap, and outstanding sealing performance Simple in structure, small in size and light in weight.
2. Polymer Housed with silicone rubber, explosion-proof ZnO varistor as the core component is large
in flow capacity.
3. International standard IEC 60099-4 and ANSI 62.22, and with high reliability. With fully insulated tops, the product can be applied to the complete cabinet installation, which can reduce the designing size of cabinet.
4. Products with detachment device can provide signals for quitting operation when failure occurs,
avoiding arrester explosion, and it is maintenance-free.
5. Polymer housed products with a six CTI level, creepage distance meets the requirements of IV level in heavy pollution areas.
Technical Parameters:
Type: |
Y5W5-108/259 |
||
Rated voltage———kV | 108 | 4/10µS High current impulse kA | 100 |
MCOV —————-kV | 86 | Lightning impulse withstand kV | 550 |
Nominal Current——-kA | 5 | Power frequency voltage withstand(dry/wet)kV | 230 |
Residual voltage of steep impulse—-at 5kA(kV) | 339 | 0.1S TOV————–kV | 129.6 |
8/20µS Residual voltage of lightning impulse current kV(Peak value)—–at 5kA(kV) | 281 | 1S TOV—————-kV | 124.2 |
Residual voltage of switching impulse current kV (peak value)—-at 1kA (kV) | 220 | 10S TOV—————kV | 118.8 |
1mA D.C reference voltage (kV) | 157 | 1200S TOV————-kV | 108 |
Line discharge level | 2 | Creepage distance —-mm | 3906 |
2mS long duration impulse current A | 600 | Material employed in series non-linear resistor | Zinc Oxide |
Working condition:
Environment temperature: -40–+40 degree | |||||||
altitude:<1000m | |||||||
48HZ<Rated frequency<62HZ | |||||||
Power frequency voltage should not be more than continuous running voltage | |||||||
Max wind speed should be less than 35m/s | |||||||
Earthquake intensity should be less than 7 degree | |||||||
If used in contamination area, should be noted in advance. |
Line discharge level from 1 to 5,
We are China Innvoation Electrical Station Class Porcelain Surge Arrestors manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular hzyddq Products
220kv Substation Porcelain Ceramic Housing Type ZnO Lightning Surge Arrester
Brown Surge Protection Device Arrester
Insulator Surge Protector Surge Arrester
Electric Three Phase Isolator Switch with Motor
Insulator Lightning Surge Arrester
110kv Metal Oxide Lightning Arrester
Popular Lightning Arrester Products
Maintenance Platform (220kV, 110kV)
12kv 100A 10ka Polymer Housed Gapless Surge Arrester
Hyy10W-30, 30kv 20ka Surge Arrester
Rated Voltage 132kv Rated Current 10ka Station Class Gapless Surge Diverter
420kv Power Station Type Electric Polymer Housing Surge Arrester
Popular Surge Arrester Products
Manufacturer 15kv Surge Protector Zinc Oxide Lightning Arrester for Transformers
Polymer Housed Metal Oxide Surge Arrester Without Gaps
Nominal System Voltage 110kv Line Composite Polymeric ZnO Arresters
220kv Station Polymer Surge Arrester/Composite Lightning Arrestor
Yh10W-100, 100kv 10ka Surge Arrester
Popular Surge Arresters Products
Power Transmission Type 110kv 10ka ZnO Surge Protector Moa Surge Diverters
12kv Polymeric Housed Metal-Oxide Lightning Surge Arrester Without Gaps
Polymeric Lightning Surge Metal-Oxide Arrester
10kv Composite Surge Protector Lightning Arrester
Kema Report Rated Voltage 18kv Moa Metal Oxide 3 Phase Lighting Arrester
Tags: hzyddq, Lightning Arrester, Surge Arrester, Surge Arresters