24kv Polymeric Housed Metal-Oxide Lightning Arrester Without Gaps
24kv Polymeric Housed Metal-Oxide Lightning Arrester Without Gaps image
Get Latest Price Request a quote
Basic Info.
Product Description
Surge Arrester Series
General
1. Ratings:0.22~500KV (porcelain),0.22~220KV(composite)
2. Application:for protection of power transmission & distribution system from over-voltage.
3. Features:
1)Silicone polymer housing composite metal oxide surge arrester and porcelain housing metal Oxide surge arresters are available.
2)Easy installation and maintenance.
3)Good sealing capability to ensure reliable operation.
4)Protection and reliability of the surge arrester have been greatly enhanced.
Working Condition
1. Ambient air temperature:-40ºC ~+40ºC ;
2. Altitude:<=2000m;
3. Frequency: 48Hz~62Hz;
4. Power frequency voltage applied between terminals of surge arrester must not exceed continuous operating voltage of surge arrerter;
5. Earthquake intensity is less than 8 degree;
6. Max. Wind speed is 35m/s.
Main Techical Parameter
1. Metal oxide Polymer Housing (Gapless) type Surge Arrester for A.C System(5kA series)
| Model | Rated voltage (kVr.m.s) | Continuous operating Voltage(KVr.m.s) | Lightening impulse residual voltage under nominal discharge current (<=KVp) | Line discharge class | Creepage distance(mm) | 2ms square wave impulse current withstands(A) | 4/10μhigh current impulse Withstands(KAp) |
| YH-5W-6 | 6 | 5.1 | 18 | 320 | 150 | 65 | |
| YH-5W-9 | 9 | 7.65 | 27 | 430 | 150 | 65 | |
| YH-5W-12 | 12 | 10.2 | 36 | 430 | 150 | 65 | |
| YH-5W-15 | 15 | 12.75 | 45 | 530 | 150 | 65 | |
| YH-5W-18 | 18 |
15.3 |
54 | 530 | 150 | 65 | |
| YH-5W-21 | 21 | 16.8 | 63 | 640 | 150 | 65 | |
| YH-5W-24 | 24 | 19.2 | 72 | 640 | 150 | 65 | |
| YH-5W-27 | 27 | 21.6 | 81 | 740 | 150 | 65 | |
| YH-5W-30 | 30 | 24 | 90 | 890 | 150 | 65 | |
| YH-5W-33 | 33 | 26.4 | 99 | 890 | 150 | 65 | |
| YH-5W-36 | 36 | 28.8 | 108 | 1115 | 150 | 65 |
2. Metal Oxide Polymer Housing (Gapless) type Surge Arrester for A.C. System (10KA series)
| Model | Rated voltage (kVr.m.s) | Continuous operating Voltage(KVr.m.s) | Lightening impulse residual voltage under nominal discharge current (<=KVp) | Line discharge class | Creepage distance(mm) | 2ms square wave impulse current withstands(A) | 4/10μhigh current impulse Withstands(KAp) |
| YH-10W-6 | 6 | 5.1 | 18 | 1 | 320 | 250 | 100 |
| YH-10W-9 | 9 | 7.65 | 27 | 1 | 430 | 250 | 100 |
| YH-10W-12 | 12 | 10.2 | 36 | 1 | 430 | 250 | 100 |
| YH-10W-15 | 15 | 12.75 | 45 | 1 | 530 | 250 | 100 |
| YH-10W-18 | 18 | 15.3 | 54 | 1 | 530 | 250 | 100 |
| YH-10W-21 | 21 | 16.8 | 63 | 1 | 640 | 250 | 100 |
| YH-10W-24 | 24 | 19.2 | 72 | 1 | 740 | 250 | 100 |
| YH-10W-27 | 27 | 21.6 | 81 | 1 | 740 | 250 | 100 |
| YH-10W-30 | 30 | 24 | 90 | 1 | 890 | 250 | 100 |
| YH-10W-33 | 33 | 26.4 | 99 | 1 | 890 | 250 | 100 |
| YH-10W-36 | 36 | 28.8 | 108 | 1 | 1115 | 250 | 100 |
| YH-10W-42 | 42 | 33.6 | 126 | 2 | 1260 | 400 | 100 |
| YH-10W-48 | 48 | 39 | 139 | 2 | 1260 | 400 | 100 |
| YH-10W-54 | 54 | 42 | 160 | 2 | 1260 | 400 | 100 |
| YH-10W-60 | 60 | 48 | 178 | 2 | 1465 | 400 | 100 |
| YH-10W-66 | 66 | 52.8 | 196 | 2 | 1465 | 400 | 100 |
| YH-10W-72 | 72 | 57 | 214 | 2 | 2255 | 400 | 100 |
| YH-10W-84 | 84 | 67.2 | 244 | 2 | 2255 | 400 | 100 |
| YH-10W-90 | 90 | 72.5 | 249 | 2 | 2255 | 400 | 100 |
| YH-10W-96 | 96 | 75 | 265 | 3 | 3555 | 800 | 100 |
| YH-10W-108 | 108 | 84 | 281 | 3 | 3555 | 800 | 100 |
| YH-10W-120 | 120 | 96 | 300 | 3 | 4153 | 800 | 100 |
| YH-10W-150 | 150 | 120 | 416 | 3 | 5040 | 800 | 100 |
| YH-10W-200 | 200 | 156 | 520 | 3 | 7110 | 800 | 100 |
3. Metal Oxide Polymer Housing (Gapless) type Surge Arrester for A.C. System (20KA series)
| Model | Rated voltage (kVr.m.s) | Continuous operating Voltage(KVr.m.s) | Lightening impulse residual voltage under nominal discharge current (<=KVp) | Line discharge class | Creepage distance(mm) | 2ms square wave impulse current withstands(A) | 4/10μhigh current impulse Withstands(KAp) |
| YH-20W-108 | 108 | 84 | 281 | 3 | 3555 | 800 | 100 |
| YH-20W-120 | 120 | 96 | 300 | 3 | 4153 | 800 | 100 |
| YH-20W-150 | 150 | 120 | 416 | 3 | 5040 | 800 | 100 |
| YH-20W-200 | 200 | 156 | 520 | 3 | 7110 | 800 | 100 |
4. Metal Oxide Porcelain Housing (Gapless) type Surge Arrester for A.C. System (5KA series)
| Model | Rated voltage (kVr.m.s) | Continuous operating Voltage(KVr.m.s) | Lightening impulse residual voltage under nominal discharge current (<=KVp) | Line discharge class | Creepage distance(mm) | 2ms square wave impulse current withstands(A) | 4/10μhigh current impulse Withstands(KAp) |
| Y5W-6 | 6 | 5.1 | 18 | 280 | 150 | 65 | |
| Y5W-9 | 9 | 7.65 | 27 | 320 | 150 | 65 | |
| Y5W-12 | 12 | 10.2 | 36 | 320 | 150 | 65 | |
| Y5W-15 | 15 | 12.75 | 45 | 450 | 150 | 65 | |
| Y5W-18 | 18 |
15.3 |
54 | 450 | 150 | 65 | |
| Y5W-21 | 21 | 16.8 | 63 | 450 | 150 | 65 | |
| Y5W-24 | 24 | 19.2 | 72 | 510 | 150 | 65 | |
| Y5W-27 | 27 | 21.6 | 81 | 510 | 150 | 65 | |
| Y5W-30 | 30 | 24 | 90 | 890 | 150 | 65 | |
| Y5W-33 | 33 | 26.4 | 99 | 890 | 150 | 65 | |
| Y5W-36 | 36 | 28.8 | 108 | 890 | 150 | 65 |
5. Metal Oxide Polymer Housing (Gapless) type Surge Arrester for A.C. System (10KA series)
| Model | Rated voltage (kVr.m.s) | Continuous operating Voltage(KVr.m.s) | Lightening impulse residual voltage under nominal discharge current (<=KVp) | Line discharge class | Creepage distance(mm) | 2ms square wave impulse current withstands(A) | 4/10μhigh current impulse Withstands(KAp) |
| Y10W-6 | 6 | 5.1 | 18 | 1 | 280 | 250 | 100 |
| Y10W-9 | 9 | 7.65 | 27 | 1 | 320 | 250 | 100 |
| Y10W-12 | 12 | 10.2 | 36 | 1 | 320 | 250 | 100 |
| Y10W-15 | 15 | 12.75 | 45 | 1 | 450 | 250 | 100 |
| Y10W-18 | 18 | 15.3 | 54 | 1 | 450 | 250 | 100 |
| Y10W-21 | 21 | 16.8 | 63 | 1 | 450 | 250 | 100 |
| Y10W-24 | 24 | 19.2 | 72 | 1 | 510 | 250 | 100 |
| Y10W-27 | 27 | 21.6 | 81 | 1 | 510 | 250 | 100 |
| Y10W-30 | 30 | 24 | 90 | 1 | 890 | 250 | 100 |
| Y10W-33 | 33 | 26.4 | 99 | 1 | 890 | 250 | 100 |
| Y10W-36 | 36 | 28.8 | 108 | 1 | 890 | 250 | 100 |
| Y10W-42 | 42 | 33.6 | 126 | 2 | 1256 | 400 | 100 |
| Y10W-48 | 48 | 39 | 139 | 2 | 1256 | 400 | 100 |
| Y10W-54 | 54 | 42 | 160 | 2 | 1256 | 400 | 100 |
| Y10W-60 | 60 | 48 | 178 | 2 | 1440 | 400 | 100 |
| Y10W-66 | 66 | 52.8 | 196 | 2 | 1440 | 400 | 100 |
| Y10W-72 | 72 | 57 | 214 | 2 | 1440 | 400 | 100 |
| Y10W-84 | 84 | 67.2 | 244 | 2 | 2200 | 400 | 100 |
| Y10W-90 | 90 | 72.5 | 249 | 2 | 2200 | 400 | 100 |
| Y10W-96 | 96 | 75 | 265 | 3 | 3350 | 800 | 100 |
| Y10W-108 | 108 | 84 | 281 | 3 | 3350 | 800 | 100 |
| Y10W-120 | 120 | 96 | 300 | 3 | 3948 | 800 | 100 |
| Y10W-150 | 150 | 120 | 416 | 3 | 4400 | 800 | 100 |
| Y10W-200 | 200 | 156 | 520 | 3 | 6700 | 800 | 100 |
6. Metal Oxide Polymer Housing (Gapless) type Surge Arrester for A.C. System (20KA series)
| Model | Rated voltage (kVr.m.s) | Continuous operating Voltage(KVr.m.s) | Lightening impulse residual voltage under nominal discharge current (<=KVp) | Line discharge class | Creepage distance(mm) | 2ms square wave impulse current withstands(A) | 4/10μhigh current impulse Withstands(KAp) |
| Y20W-108 | 108 | 84 | 281 | 3 | 3555 | 800 | 100 |
| Y20W-120 | 120 | 96 | 300 | 3 | 4106 | 800 | 100 |
| Y20W-150 | 150 | 120 | 416 | 3 | 4400 | 800 | 100 |
| Y20W-200 | 200 | 156 | 520 | 3 | 6700 | 800 | 100 |
| Y20W-444 | 444 | 324 | 1106 | 4 | 17052 | 2000 | 100 |
Note: For details, please refer to the catalogue.
Participate in the exhibition pictures
testing report
We are China 24kv Polymeric Housed Metal-Oxide Lightning Arrester Without Gaps manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Lightning Arrester Products
Yh10W-216.216kv 10ka Surge Arrester 01
Polymeric Housed Metal-Oxide Surge Arrester Without Gaps (YH5W-6)
Custom Available Power Station Equipment 110kv Porcelain Ceramic Arrester
Hangzhou Substation Type Rated Voltage 3-36kv Composite Housed Surge Protectors
Polymer Housed Metal Oxide Surge Arrestes Without Gaps
Popular metal oxide lightning arrester Products
21kv Silicone Polymer Housing Composite Metal Oxide Lightning Arrester
33kv Silicone Polymer Housing Composite Metal Oxide Lightning Arrester
Porcelain Housed Metal Oxide Lightning Arrester (Surge Arrester)
36kv Silicone Polymer Housing Composite Metal Oxide Lightning Arrester
Kema Silicone Housed Series Medium Voltage Zinc-Oxide Lightning Arrester (YH10W5-9)
12kv Silicone Polymer Housing Composite Metal Oxide Lightning Arrester
Popular people Products
High Quality Drop-out Fuse Cutout with Load Cutout
30kv High Quality Electrical Lightning Arrester for Transmission Line
42kv Polymer Housing Oxide Zinc Lightning Arrester on Transmission Line
12kv Outdoor Expulsion Drop-out Type Loadbreak Fuse Cutout
11kv Silicone Rubber Pin Composite Insulator
10kv-35kv Polymer/Composite/Polymeric Post Insulator/Silicone Rubber Insulator
Popular Polymeric Housed Lightning Arrester Products
21kv Polymeric Housed Metal-Oxide Lightning Arrester Without Gaps
9kv Polymeric Housed Metal-Oxide Lightning Arrester Without Gaps
12kv Polymeric Housed Metal-Oxide Lightning Arrester Without Gaps
30kv Polymeric Housed Metal-Oxide Lightning Arrester Without Gaps
36kv Polymeric Housed Metal-Oxide Lightning Arrester Without Gaps
33kv Polymeric Housed Metal-Oxide Lightning Arrester Without Gaps
Tags: Lightning Arrester, metal oxide lightning arrester, people, Polymeric Housed Lightning Arrester