120kv Outdoor Disconnect Switch Three Phases 100ka
120kv Outdoor Disconnect Switch Three Phases 100ka image
Get Latest Price Request a quote
Basic Info.
Product Description
Single Pole Switch Isolator, 22kV, 800/630A
1.0 General
The single pole switch isolator are used for isolating feeders and lines.
2.0 Service Conditions
a. Ambient Temperature : 5°C – 50°C
b. Relative Humidity : 95% at 45°C (Tropicalised)
c. Environmental condition: Tropical climate with polluted atmosphere
3.0 System Parameters
The switch shall be used on a network having the following characteristics:-
a. Nominal voltage : 22 kV
b. Maximum voltage : 24 kV
c. Earthing Arrangement : Effectively earthed
d. Frequency : 50 Hz
4.0 Standards
The item conform to IEC 60129 or IEC62271-102 Ed.1.0 (2001)-Alternating current disconnectors & earthing switches or any other equivalent international standards.
It will be the responsibility of our to prove equivalency of his standard with one of these 2 standards mentioned above.
5.0 Technical requirements
a. Rated voltage : 24kV
b. Rated continuous current : 630A
c. Impulse Voltage Level (BIL) : 150kV
d. Rated Short time withstand current : 25kA/1 sec
e. Rated peak withstand current : 62kA
f. Creepage Distance : 600mm
6.0 Basic Features
The isolating switch have the following characteristics;
– Single pole type suitable for outdoor use
– Double insulator construction
– Fitted with appropriate latching device to prevent accidental opening due to faults, line vibration, wind or other environmental influences
– Operated by portable insulated hook stick
– Suitable for underslung or vertical mounting
– Fitted with Tin plated palms suitable for Copper and Aluminium compression lugs
– The palms are suitable to accommodate conductor AAAC 150mm2 to BSEN50183: 2000 or armoured cable XLPE insulated 300mm2 Copper or 240mm2 Aluminium to IEC 502
– Incoming and outgoing conductor/cable are connected on fixed parts and not on rocking parts
Information to be furnished with the offer
The following are furnished with the offer:
a) Type Test Reports conforming to the relevant IEC Standards
b) Catalogues, Technical literature and dimensional drawings of the item offered
c) Detailed list of components
d) Duly filled Schedule of guaranteed particulars (Annexure A).
e) ISO 9001:2000 Certificate including the requirements as defined by clause 7 of the ISO 9001:2000 Standard.
f) A list of the supplier’s orders for the last five years.
GUARANTEED PARTICULARS
Single pole switch isolator, 22kV , 800/630A
POV2568
Serial No. | Description | ||
1. | Manufacturer’s Reference name/code | OEIpower | |
2. | Drawing No. | IS-24 | |
3. | Country of Origin | ||
4. | Standard specifications to which the switch conform | IEC62271-102 | |
5. | Rated Voltage | kV | 24 |
6. | Rated frequency | Hz | 50 |
7. | Rated continuous current | A | 630 |
8. | Rated short time current duration |
kA sec |
25kA/1 sec |
9. | Impulse voltage withstand 1.2/50µ S |
kV |
150 |
10. | Total creepage distance | mm | 600 |
We are China 120kv Outdoor Disconnect Switch Three Phases 100ka manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular 120kv Outdoor Disconnect Switch Three Phases 100ka Products
Popular Disconnector Switch Products
High -Voltage Isolate Switch 12kv 200A
Outdoor Pole Mounted Load Break Switch
Popular jgtrade1 Products
Two-Way Clamps with Three Bolts
Self-Tightening Clamps for ACSR Conductor ‘ Sock’ Type
Low Voltage Cable Junction Box
Popular Switch Disconnector Products
Gw16 Outdoor High Voltage Semi-Pantography Disconnector
T-Connectors Type Tl, with Jump Clamp
High Voltage Switch Disconnector Series Gw9-15
Disconnect Switch 145 Kv, 40 Ka, 3150 a with Grounding Blades
Medium Voltage Disconnector Switch Switch Isolator Price Gw9
24kv 33kv High Voltage Dropout Fuse Cutout Switch
Tags: 120kv Outdoor Disconnect Switch Three Phases 100ka, Disconnector Switch, jgtrade1, Switch Disconnector