AC2xh Na2xh XLPE Insulated Halogen Free Power Cable
AC2xh Na2xh XLPE Insulated Halogen Free Power Cable image
Get Latest Price Request a quote
- Overview
- Product Description
- Product Parameters
Basic Info.
Product Description
AC2XH NA2XH XLPE Insulated halogen free power cable
Application:
In earth, ducts, on support brackets, in dry and wet conditions etc., where one does not expect mechanical damages and the cables are not exposed to the mechanical tensile strain. In urban networks, industrial plants, electric power plants and other electricity consumers and for connection of control devices in industry, traffic etc.
NA2XH CABLE CONSTRUCTION:
Conductors: Al, class 1 (RE/SE) or class 2 (RM/SM) according to EN 60228
Insulation: XLPE compound DIX 3
Bedding: Extruded elastomere or plastomere compound or plastic tape
Sheath: HFFR compound HM 4
Technical data:
CPR class: Eca
Test voltage: 4 kV
Rated voltage: 0,6/1,0 kV
Bending radius (min): single-core – 15D;
multicore – 12D
Min. laying temperature: -5°C
Max. conductor temperature: 90°C
Max. short-circuit temperature: 250°C
Industry: Building & Construction, Transmission, Distribution & Power Networks
Standard: IEC 60502-1, SI 1516-1
Type: Industrial Cable, LSZH Cable, Power Network & Local Distribution Cable
NA2XH CABLE DIMENSION:
| SINGLE – CORE CABLES: | ||||||||
| NOMINAL CROSS SECTION | CONDUCTOR CONSTRUCTION | NOM. THICKNESS OF INSUL. | OUTER DIAM. (APPROX.) | METAL WEIGHT | CABLE WEIGHT (APPROX.) | MAX. RESISTANCE AT 20°C | CURRENT CAPACITY IN AIR | CURRENT CAPACITY IN EARTH |
| mm2 | mm | mm | kg/km | kg/km | ohm/km | A | A | |
| 1×16 | rm | 0,7 | 9,5 | 46,2 | 122 | 1,910 | – | – |
| 1×25 | rm | 0,9 | 11,9 | 72,5 | 175 | 1,200 | 106 | 114 |
| 1×35 | rm | 0,9 | 13,0 | 101,5 | 206 | 0,868 | 130 | 136 |
| 1×50 | rm | 1,0 | 14,9 | 145,0 | 267 | 0,641 | 161 | 162 |
| 1×70 | rm | 1,1 | 17,0 | 203,0 | 358 | 0,443 | 204 | 199 |
| 1×95 | rm | 1,1 | 18,9 | 275,5 | 451 | 0,320 | 252 | 238 |
| 1×120 | rm | 1,2 | 20,7 | 348,0 | 546 | 0,253 | 295 | 272 |
| 1×150 | rm | 1,4 | 22,7 | 435,0 | 655 | 0,206 | 339 | 305 |
| 1×185 | rm | 1,6 | 25,1 | 536,5 | 800 | 0,164 | 395 | 347 |
| 1×240 | rm | 1,7 | 27,6 | 696,0 | 987 | 0,125 | 472 | 404 |
| 1×300 | rm | 1,8 | 31,9 | 870,0 | 1324 | 0,100 | 547 | 457 |
| 1×400 | rm | 2,0 | 34,9 | 1160,0 | 1640 | 0,0778 | 643 | 525 |
| 1×500 | rm | 2,2 | 39,3 | 1450,0 | 2030 | 0,0605 | 754 | 601 |
| 1×630 | rm | 2,4 | 44,1 | 1827,0 | 2400 | 0,0469 | 882 | 687 |
| 1×800 | rm | 2,6 | 46,5 | 2320,0 | 2505 | 0,0367 | 1019 | 776 |
| 1×1000 | rm | 2,8 | 52,0 | 2900,0 | 3115 | 0,0291 | 1157 | 865 |
| THREE – CORE CABLES: | ||||||||
| NOMINAL CROSS SECTION | CONDUCTOR CONSTRUCTION | NOM. THICKNESS OF INSUL. | OUTER DIAM. (APPROX.) | METAL WEIGHT | CABLE WEIGHT (APPROX.) | MAX. RESISTANCE AT 20°C | CURRENT CAPACITY IN AIR | CURRENT CAPACITY IN EARTH |
| mm2 | mm | mm | kg/km | kg/km | ohm/km | A | A | |
| 3×16 | rm | 0,7 | 16,5 | 139,2 | 397 | 1,910 | – | – |
| 3×25 | rm | 0,9 | 20,0 | 217,5 | 587 | 1,200 | 102 | 112 |
| 3×35 | rm/sm | 0,9 | 22,5 | 304,5 | 531 | 0,868 | 126 | 135 |
| 3×50 | rm | 1,0 | 27,6 | 435,0 | 1007 | 0,641 | 149 | 158 |
| 3×70 | rm | 1,1 | 30,6 | 609,0 | 1401 | 0,443 | 191 | 196 |
| 3×95 | rm | 1,1 | 33,8 | 826,5 | 1801 | 0,320 | 234 | 234 |
| 3×120 | rm | 1,2 | 37,5 | 1044,0 | 2226 | 0,253 | 273 | 268 |
| 3×50 | se/sm | 1,0 | 26,0 | 435,0 | 720 | 0,641 | 149 | 158 |
| 3×70 | se/sm | 1,1 | 29,7 | 609,0 | 963 | 0,443 | 191 | 196 |
| 3×95 | se/sm | 1,1 | 33,4 | 826,5 | 1246 | 0,320 | 234 | 234 |
| 3×120 | se/sm | 1,2 | 37,1 | 1044,0 | 1545 | 0,253 | 273 | 268 |
| 3×150 | se/sm | 1,4 | 41,2 | 1305,0 | 1916 | 0,206 | 311 | 300 |
| 3×185 | se/sm | 1,6 | 45,7 | 1609,5 | 2347 | 0,164 | 360 | 342 |
| 3×240 | se/sm | 1,7 | 51,6 | 2088,0 | 2987 | 0,125 | 427 | 398 |
| 3×300 | se/sm | 1,8 | 56,7 | 2160,0 | 3663 | 0,100 | 507 | 457 |
| FOUR – CORE CABLES | ||||||||
| NOMINAL CROSS SECTION | CONDUCTOR CONSTRUCTION | NOM. THICKNESS OF INSUL. | OUTER DIAM. (APPROX.) | METAL WEIGHT | CABLE WEIGHT (APPROX.) | MAX. RESISTANCE AT 20°C | CURRENT CAPACITY IN AIR | CURRENT CAPACITY IN EARTH |
| mm2 | mm | mm | kg/km | kg/km | ohm/km | A | A | |
| 3×70+35 | sm/sm | 1,1/0,9 | 28,8 | 655,4 | 935 | 0,443/0,868 | 191 | 196 |
| 3×95+50 | sm/sm | 1,1/1,0 | 32,2 | 899,0 | 1120 | 0,320/0,641 | 234 | 234 |
| 3×120+70 | sm/sm | 1,2/1,1 | 34,6 | 1145,5 | 1430 | 0,253/0,443 | 273 | 268 |
| 3×150+70 | sm/sm | 1,4/1,1 | 38,5 | 1450,0 | 1950 | 0,206/0,443 | 311 | 300 |
| 3×185+95 | sm/sm | 1,6/1,1 | 42,4 | 1812,5 | 2345 | 0,164/0,320 | 360 | 342 |
| 3×240+120 | sm/sm | 1,7/1,2 | 47,2 | 2363,5 | 2980 | 0,125/0,253 | 427 | 398 |
| 4×35 | sm | 0,9 | 25,9 | 406,0 | 690 | 0,868 | 126 | 135 |
| 4×50 | se/sm | 1,0 | 28,4 | 580,0 | 832 | 0,641 | 149 | 158 |
| 4×70 | se/sm | 1,1 | 32,4 | 812,0 | 1234 | 0,443 | 191 | 196 |
| 4×95 | se/sm | 1,1 | 35,6 | 1102,0 | 1460 | 0,320 | 234 | 234 |
| 4×120 | se/sm | 1,2 | 40,6 | 1392,0 | 1861 | 0,253 | 273 | 268 |
| 4×150 | se/sm | 1,4 | 44,8 | 1740,0 | 2386 | 0,206 | 311 | 300 |
| 4×185 | se/sm | 1,6 | 49,2 | 2146,0 | 2866 | 0,164 | 360 | 342 |
| 4×240 | se/sm | 1,7 | 54,9 | 2784,0 | 3616 | 0,125 | 427 | 398 |
| 4×300 | se/sm | 1,8 | 58,8 | 3480,0 | 4500 | 0,100 | 507 | 457 |
| FOUR – CORE CABLES WITH CONTROL CONDUCTOR | ||||||||
| NOMINAL CROSS SECTION | CONDUCTOR CONSTRUCTION | NOM. THICKNESS OF INSUL. | OUTER DIAM. (APPROX.) | METAL WEIGHT | CABLE WEIGHT (APPROX.) | MAX. RESISTANCE AT 20°C | CURRENT CAPACITY IN AIR | CURRENT CAPACITY IN EARTH |
| mm2 | mm | mm | kg/km | kg/km | ohm/km | A | A | |
| 4×16+1,5 | re/rm | 0,7 | 22,1 | 185,6 | 615 | 1,910 | – | – |
| 4×25+1,5 | re/rm | 0,9 | 26,2 | 290,0 | 870 | 1,200 | 102 | 112 |
| 4×35+1,5 | re/rm | 0,9 | 28,9 | 406,0 | 1074 | 0,868 | 126 | 135 |
| 4×35+1,5 | sm | 0,9 | 23,1 | 406,0 | 630 | 0,868 | 126 | 135 |
| 4×50+1,5 | se/sm | 1,0 | 26,0 | 580,0 | 847 | 0,641 | 149 | 158 |
| 4×70+1,5 | se/sm | 1,1 | 30,0 | 812,0 | 1135 | 0,443 | 191 | 196 |
| 4×95+1,5 | se/sm | 1,1 | 33,6 | 1102,0 | 1480 | 0,320 | 234 | 234 |
| 4×120+1,5 | se/sm | 1,2 | 37,3 | 1392,0 | 1826 | 0,253 | 273 | 268 |
| 4×150+1,5 | se/sm | 1,4 | 42,0 | 1740,0 | 2282 | 0,206 | 311 | 300 |
| 4×185+1,5 | se/sm | 1,6 | 46,3 | 2146,0 | 2766 | 0,164 | 360 | 342 |
| 4×240+1,5 | se/sm | 1,7 | 52,1 | 2784,0 | 3572 | 0,125 | 427 | 398 |
| 4×300+1,5 | se/sm | 1,8 | 56,8 | 3480,0 | 4374 | 0,100 | 507 | 457 |
SIGNAL CU WIRE: Nominal cross section: 1,5 mm² Max. resistance at 20°C :12,1 Ω/km Nom. thicknss of insul. :0,7mm Outer diameter :2,9mm
| FIVE – CORE CABLES | ||||||||
| NOMINAL CROSS SECTION | CONDUCTOR CONSTRUCTION | NOM. THICKNESS OF INSUL. | OUTER DIAM. (APPROX.) | METAL WEIGHT | CABLE WEIGHT (APPROX.) | MAX. RESISTANCE AT 20°C | CURRENT CAPACITY IN AIR | CURRENT CAPACITY IN EARTH |
| mm2 | mm | mm | kg/km | kg/km | ohm/km | A | A | |
| 5×16 | rm | 0,7 | 23,4 | 232,0 | 625 | 1,910 | – | – |
| 5×25 | rm | 0,9 | 28,2 | 362,5 | 950 | 1,200 | 102 | 112 |
| 5×35 | rm | 0,9 | 31,0 | 507,5 | 1195 | 0,868 | 126 | 135 |
| 5×50 | rm | 1,0 | 36,8 | 725,0 | 1540 | 0,641 | 149 | 158 |
| 5×70 | rm | 1,1 | 42,8 | 1015,0 | 2240 | 0,443 | 191 | 196 |
| 5×95 | rm | 1,1 | 48,5 | 1377,5 | 3015 | 0,320 | 234 | 234 |
| 5×120 | rm | 1,2 | 53,6 | 1740,0 | 3580 | 0,253 | 273 | 268 |
NA2XH CABLE SELECTION:
In addition to our portfolio of European power cables we also supply British standard low voltage power cables including armoured cable with its LSZH outer sheathing. Our technical has a wealth of experience in providing support in the selection of the right cable for your application. Please call to discuss your specific application.
If you have another question, pls feel free to contact Vivian Yuan from Hongda Cable.
We are China AC2xh Na2xh XLPE Insulated Halogen Free Power Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular AC2xh Na2xh XLPE Insulated Halogen Free Power Cable Products
Popular Na2xh Cable Products
Aluminum Conductor XLPE Insulated and Hffr Sheath Na2xh Power Cable
Na2xh 0.6/1 K Al Conductors XLPE Insulated and Hffr Sheathed Aluminum Cable
Popular Power Cable Products
2X6mm2 Hard Drawn Copper Conductor XLPE Insulated Concentric Service Cable
ABC Cable Manufacturer XLPE Insulated ABC Cable
Copper XLPE Insulated Flame Retardant Armored Power Cable
Copper Conductor XLPE Insulated Armoured Power Cable
Popular zzhongdacable Products
50mm Cable 400mm2 Cable 300mm Single Core Cable
0.6/1kv XLPE Insulated PVC 1X240mm2 Single Core RV-K Yjvr Copper Flexible Electrical Wire Cable
4X240sqmm Cu/XLPE Insulated Steel Tape Armoured 600/1000V Electric Cable
15kv Urd 133% Insulation Ud Cable Tr-XLPE Cable
Underground Power Cable Conductor Aluminio Subterraneo 70mm2 120mm2 240mm2 25kv
Low Voltage PVC XLPE Industrial Control Cable
Tags: AC2xh Na2xh XLPE Insulated Halogen Free Power Cable, Na2xh Cable, Power Cable, zzhongdacable