Aluminum Conductor XLPE Insulated and Hffr Sheath Na2xh Power Cable

China 
                Aluminum Conductor XLPE Insulated and Hffr Sheath Na2xh Power Cable
              manufacture and supplier

Aluminum Conductor XLPE Insulated and Hffr Sheath Na2xh Power Cable image

Get Latest Price Request a quote

  • Overview
  • Product Description
  • Product Parameters

Overview

Basic Info.

Model NO.
Na2xh cable

Wire Core Material
Bare Copper Wire

Certification
ISO, CCC, SGS

Model
N2xh

Brand
Hongda

Temperature Range
-5°c Till +90°c

Bending Radius
15-12 Diameter

Operating Temperature
250c

Test Voltage
4000 [V]AC

Nominal Voltage Uo/U
600 / 1000 Volt

Transport Package
Steel Wooden Drum

Specification
6mm2 to 300mm2

Trademark
Hongda

Origin
China

HS Code
8544492100

Production Capacity
500km/Month

Product Description

Product Description

 

Power cable 0,6/1 kV with Al conductors, XLPE insulated and HFFR sheathed -NA2XH

Application:
In earth, ducts, on support brackets, in dry and wet conditions etc., where one does not expect mechanical damages and the cables are not exposed to the mechanical tensile strain. In urban networks, industrial plants, electric power plants and other electricity consumers and for connection of control devices in industry, traffic etc.

NA2XH CABLE CONSTRUCTION:
Conductors: Al, class 1 (RE/SE) or class 2 (RM/SM) according to EN 60228
Insulation: XLPE compound DIX 3
Bedding: Extruded elastomere or plastomere compound or plastic tape
Sheath: HFFR compound HM 4

Technical data:
CPR class: Eca
Test voltage: 4 kV
Rated voltage: 0,6/1,0 kV
Bending radius (min): single-core – 15D;
multicore – 12D
Min. laying temperature: -5°C
Max. conductor temperature: 90°C
Max. short-circuit temperature: 250°C

Industry: Building & Construction, Transmission, Distribution & Power Networks
Standard: IEC 60502-1, SI 1516-1
Type: Industrial Cable, LSZH Cable, Power Network & Local Distribution Cable
 

Product Parameters

 

NA2XH CABLE DIMENSION:

SINGLE – CORE CABLES:
NOMINAL CROSS SECTION CONDUCTOR CONSTRUCTION NOM. THICKNESS OF INSUL. OUTER DIAM. (APPROX.) METAL WEIGHT CABLE WEIGHT (APPROX.) MAX. RESISTANCE AT 20°C CURRENT CAPACITY IN AIR CURRENT CAPACITY IN EARTH
mm2   mm mm kg/km kg/km ohm/km A A
1×16 rm 0,7 9,5 46,2 122 1,910
1×25 rm 0,9 11,9 72,5 175 1,200 106 114
1×35 rm 0,9 13,0 101,5 206 0,868 130 136
1×50 rm 1,0 14,9 145,0 267 0,641 161 162
1×70 rm 1,1 17,0 203,0 358 0,443 204 199
1×95 rm 1,1 18,9 275,5 451 0,320 252 238
1×120 rm 1,2 20,7 348,0 546 0,253 295 272
1×150 rm 1,4 22,7 435,0 655 0,206 339 305
1×185 rm 1,6 25,1 536,5 800 0,164 395 347
1×240 rm 1,7 27,6 696,0 987 0,125 472 404
1×300 rm 1,8 31,9 870,0 1324 0,100 547 457
1×400 rm 2,0 34,9 1160,0 1640 0,0778 643 525
1×500 rm 2,2 39,3 1450,0 2030 0,0605 754 601
1×630 rm 2,4 44,1 1827,0 2400 0,0469 882 687
1×800 rm 2,6 46,5 2320,0 2505 0,0367 1019 776
1×1000 rm 2,8 52,0 2900,0 3115 0,0291 1157 865
THREE – CORE CABLES:
NOMINAL CROSS SECTION CONDUCTOR CONSTRUCTION NOM. THICKNESS OF INSUL. OUTER DIAM. (APPROX.) METAL WEIGHT CABLE WEIGHT (APPROX.) MAX. RESISTANCE AT 20°C CURRENT CAPACITY IN AIR CURRENT CAPACITY IN EARTH
mm2   mm mm kg/km kg/km ohm/km A A
3×16 rm 0,7 16,5 139,2 397 1,910
3×25 rm 0,9 20,0 217,5 587 1,200 102 112
3×35 rm/sm 0,9 22,5 304,5 531 0,868 126 135
3×50 rm 1,0 27,6 435,0 1007 0,641 149 158
3×70 rm 1,1 30,6 609,0 1401 0,443 191 196
3×95 rm 1,1 33,8 826,5 1801 0,320 234 234
3×120 rm 1,2 37,5 1044,0 2226 0,253 273 268
3×50 se/sm 1,0 26,0 435,0 720 0,641 149 158
3×70 se/sm 1,1 29,7 609,0 963 0,443 191 196
3×95 se/sm 1,1 33,4 826,5 1246 0,320 234 234
3×120 se/sm 1,2 37,1 1044,0 1545 0,253 273 268
3×150 se/sm 1,4 41,2 1305,0 1916 0,206 311 300
3×185 se/sm 1,6 45,7 1609,5 2347 0,164 360 342
3×240 se/sm 1,7 51,6 2088,0 2987 0,125 427 398
3×300 se/sm 1,8 56,7 2160,0 3663 0,100 507 457

 

FOUR – CORE CABLES
NOMINAL CROSS SECTION CONDUCTOR CONSTRUCTION NOM. THICKNESS OF INSUL. OUTER DIAM. (APPROX.) METAL WEIGHT CABLE WEIGHT (APPROX.) MAX. RESISTANCE AT 20°C CURRENT CAPACITY IN AIR CURRENT CAPACITY IN EARTH
mm2   mm mm kg/km kg/km ohm/km A A
3×70+35 sm/sm 1,1/0,9 28,8 655,4 935 0,443/0,868 191 196
3×95+50 sm/sm 1,1/1,0 32,2 899,0 1120 0,320/0,641 234 234
3×120+70 sm/sm 1,2/1,1 34,6 1145,5 1430 0,253/0,443 273 268
3×150+70 sm/sm 1,4/1,1 38,5 1450,0 1950 0,206/0,443 311 300
3×185+95 sm/sm 1,6/1,1 42,4 1812,5 2345 0,164/0,320 360 342
3×240+120 sm/sm 1,7/1,2 47,2 2363,5 2980 0,125/0,253 427 398
4×35 sm 0,9 25,9 406,0 690 0,868 126 135
4×50 se/sm 1,0 28,4 580,0 832 0,641 149 158
4×70 se/sm 1,1 32,4 812,0 1234 0,443 191 196
4×95 se/sm 1,1 35,6 1102,0 1460 0,320 234 234
4×120 se/sm 1,2 40,6 1392,0 1861 0,253 273 268
4×150 se/sm 1,4 44,8 1740,0 2386 0,206 311 300
4×185 se/sm 1,6 49,2 2146,0 2866 0,164 360 342
4×240 se/sm 1,7 54,9 2784,0 3616 0,125 427 398
4×300 se/sm 1,8 58,8 3480,0 4500 0,100 507 457
FOUR – CORE CABLES WITH CONTROL CONDUCTOR
NOMINAL CROSS SECTION CONDUCTOR CONSTRUCTION NOM. THICKNESS OF INSUL. OUTER DIAM. (APPROX.) METAL WEIGHT CABLE WEIGHT (APPROX.) MAX. RESISTANCE AT 20°C CURRENT CAPACITY IN AIR CURRENT CAPACITY IN EARTH
mm2   mm mm kg/km kg/km ohm/km A A
4×16+1,5 re/rm 0,7 22,1 185,6 615 1,910
4×25+1,5 re/rm 0,9 26,2 290,0 870 1,200 102 112
4×35+1,5 re/rm 0,9 28,9 406,0 1074 0,868 126 135
4×35+1,5 sm 0,9 23,1 406,0 630 0,868 126 135
4×50+1,5 se/sm 1,0 26,0 580,0 847 0,641 149 158
4×70+1,5 se/sm 1,1 30,0 812,0 1135 0,443 191 196
4×95+1,5 se/sm 1,1 33,6 1102,0 1480 0,320 234 234
4×120+1,5 se/sm 1,2 37,3 1392,0 1826 0,253 273 268
4×150+1,5 se/sm 1,4 42,0 1740,0 2282 0,206 311 300
4×185+1,5 se/sm 1,6 46,3 2146,0 2766 0,164 360 342
4×240+1,5 se/sm 1,7 52,1 2784,0 3572 0,125 427 398
4×300+1,5 se/sm 1,8 56,8 3480,0 4374 0,100 507 457

SIGNAL CU WIRE: Nominal cross section: 1,5 mm² Max. resistance at 20°C :12,1 Ω/km Nom. thicknss of insul. :0,7mm Outer diameter :2,9mm
 

FIVE – CORE CABLES
NOMINAL CROSS SECTION CONDUCTOR CONSTRUCTION NOM. THICKNESS OF INSUL. OUTER DIAM. (APPROX.) METAL WEIGHT CABLE WEIGHT (APPROX.) MAX. RESISTANCE AT 20°C CURRENT CAPACITY IN AIR CURRENT CAPACITY IN EARTH
mm2   mm mm kg/km kg/km ohm/km A A
5×16 rm 0,7 23,4 232,0 625 1,910
5×25 rm 0,9 28,2 362,5 950 1,200 102 112
5×35 rm 0,9 31,0 507,5 1195 0,868 126 135
5×50 rm 1,0 36,8 725,0 1540 0,641 149 158
5×70 rm 1,1 42,8 1015,0 2240 0,443 191 196
5×95 rm 1,1 48,5 1377,5 3015 0,320 234 234
5×120 rm 1,2 53,6 1740,0 3580 0,253 273 268

NA2XH CABLE SELECTION:
In addition to our portfolio of European power cables we also supply British standard low voltage power cables including armoured cable with its LSZH outer sheathing. Our technical has a wealth of experience in providing support in the selection of the right cable for your application. Please call to discuss your specific application.

If you have another question, pls feel free to contact us below
 

We are China Aluminum Conductor XLPE Insulated and Hffr Sheath Na2xh Power Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular Aluminum Conductor XLPE Insulated and Hffr Sheath Na2xh Power Cable Products

  • No related articles
  • Popular Na2xh Cable Products

    AC2xh Na2xh XLPE Insulated Halogen Free Power Cable

    Na2xh 0.6/1 K Al Conductors XLPE Insulated and Hffr Sheathed Aluminum Cable

    Popular Power Cable Products

    Hot Sale PVC Insulated Flexible Electric Wire PVC Wire Coated

    Multi Core 4 Core 5 Core 25mm Underground Electric XLPE Insulation Power Cable

    12/20kv 1X50mm2 Unipolar Tipo N2xsy Power Cable

    High Performance PVC Insulated Power Cable

    0.6/1kv 4 Core 35mm2 PVC Insulated and Sheathed Electric Aluminum Conductor Cable

    0.6/1kv Cores XLPE Insulated PVC Sheathed Power Cable Yjv/Yjlv

    Popular zzhongdacable Products

    Price of Electrical Cable 16mm2 240mm2 Power Cable

    Low Voltage Na2xy Cables 4*95mm2 Al XLPE PVC 4 Cores 95sqmm Underground Aluminum Power Cable

    240mm XLPE 4 Core Armoured Cable

    Tw/Thw Electrical Wire 10AWG Stranded Copper Wire PVC Insulated Electrical Wire

    Polyvinyl Chloride Insulated Cables and Cords of Rated Voltages up to and Including 450/750V

    Low Voltage Yjv 1kv Copper Cable 240 mm2 Philippines XLPE Power Cable

    Tags: , , ,

    FAST AND RELIABLE SERVICE FOR YOUR PROJECT

    Contact our trained experts today to find your perfect power solution.

    ASK A QUESTION