Aluminum Conductor XLPE Insulated and Hffr Sheath Na2xh Power Cable
Aluminum Conductor XLPE Insulated and Hffr Sheath Na2xh Power Cable image
Get Latest Price Request a quote
- Overview
- Product Description
- Product Parameters
Basic Info.
Product Description
Power cable 0,6/1 kV with Al conductors, XLPE insulated and HFFR sheathed -NA2XH
Application:
In earth, ducts, on support brackets, in dry and wet conditions etc., where one does not expect mechanical damages and the cables are not exposed to the mechanical tensile strain. In urban networks, industrial plants, electric power plants and other electricity consumers and for connection of control devices in industry, traffic etc.
NA2XH CABLE CONSTRUCTION:
Conductors: Al, class 1 (RE/SE) or class 2 (RM/SM) according to EN 60228
Insulation: XLPE compound DIX 3
Bedding: Extruded elastomere or plastomere compound or plastic tape
Sheath: HFFR compound HM 4
Technical data:
CPR class: Eca
Test voltage: 4 kV
Rated voltage: 0,6/1,0 kV
Bending radius (min): single-core – 15D;
multicore – 12D
Min. laying temperature: -5°C
Max. conductor temperature: 90°C
Max. short-circuit temperature: 250°C
Industry: Building & Construction, Transmission, Distribution & Power Networks
Standard: IEC 60502-1, SI 1516-1
Type: Industrial Cable, LSZH Cable, Power Network & Local Distribution Cable
NA2XH CABLE DIMENSION:
SINGLE – CORE CABLES: | ||||||||
NOMINAL CROSS SECTION | CONDUCTOR CONSTRUCTION | NOM. THICKNESS OF INSUL. | OUTER DIAM. (APPROX.) | METAL WEIGHT | CABLE WEIGHT (APPROX.) | MAX. RESISTANCE AT 20°C | CURRENT CAPACITY IN AIR | CURRENT CAPACITY IN EARTH |
mm2 | mm | mm | kg/km | kg/km | ohm/km | A | A | |
1×16 | rm | 0,7 | 9,5 | 46,2 | 122 | 1,910 | – | – |
1×25 | rm | 0,9 | 11,9 | 72,5 | 175 | 1,200 | 106 | 114 |
1×35 | rm | 0,9 | 13,0 | 101,5 | 206 | 0,868 | 130 | 136 |
1×50 | rm | 1,0 | 14,9 | 145,0 | 267 | 0,641 | 161 | 162 |
1×70 | rm | 1,1 | 17,0 | 203,0 | 358 | 0,443 | 204 | 199 |
1×95 | rm | 1,1 | 18,9 | 275,5 | 451 | 0,320 | 252 | 238 |
1×120 | rm | 1,2 | 20,7 | 348,0 | 546 | 0,253 | 295 | 272 |
1×150 | rm | 1,4 | 22,7 | 435,0 | 655 | 0,206 | 339 | 305 |
1×185 | rm | 1,6 | 25,1 | 536,5 | 800 | 0,164 | 395 | 347 |
1×240 | rm | 1,7 | 27,6 | 696,0 | 987 | 0,125 | 472 | 404 |
1×300 | rm | 1,8 | 31,9 | 870,0 | 1324 | 0,100 | 547 | 457 |
1×400 | rm | 2,0 | 34,9 | 1160,0 | 1640 | 0,0778 | 643 | 525 |
1×500 | rm | 2,2 | 39,3 | 1450,0 | 2030 | 0,0605 | 754 | 601 |
1×630 | rm | 2,4 | 44,1 | 1827,0 | 2400 | 0,0469 | 882 | 687 |
1×800 | rm | 2,6 | 46,5 | 2320,0 | 2505 | 0,0367 | 1019 | 776 |
1×1000 | rm | 2,8 | 52,0 | 2900,0 | 3115 | 0,0291 | 1157 | 865 |
THREE – CORE CABLES: | ||||||||
NOMINAL CROSS SECTION | CONDUCTOR CONSTRUCTION | NOM. THICKNESS OF INSUL. | OUTER DIAM. (APPROX.) | METAL WEIGHT | CABLE WEIGHT (APPROX.) | MAX. RESISTANCE AT 20°C | CURRENT CAPACITY IN AIR | CURRENT CAPACITY IN EARTH |
mm2 | mm | mm | kg/km | kg/km | ohm/km | A | A | |
3×16 | rm | 0,7 | 16,5 | 139,2 | 397 | 1,910 | – | – |
3×25 | rm | 0,9 | 20,0 | 217,5 | 587 | 1,200 | 102 | 112 |
3×35 | rm/sm | 0,9 | 22,5 | 304,5 | 531 | 0,868 | 126 | 135 |
3×50 | rm | 1,0 | 27,6 | 435,0 | 1007 | 0,641 | 149 | 158 |
3×70 | rm | 1,1 | 30,6 | 609,0 | 1401 | 0,443 | 191 | 196 |
3×95 | rm | 1,1 | 33,8 | 826,5 | 1801 | 0,320 | 234 | 234 |
3×120 | rm | 1,2 | 37,5 | 1044,0 | 2226 | 0,253 | 273 | 268 |
3×50 | se/sm | 1,0 | 26,0 | 435,0 | 720 | 0,641 | 149 | 158 |
3×70 | se/sm | 1,1 | 29,7 | 609,0 | 963 | 0,443 | 191 | 196 |
3×95 | se/sm | 1,1 | 33,4 | 826,5 | 1246 | 0,320 | 234 | 234 |
3×120 | se/sm | 1,2 | 37,1 | 1044,0 | 1545 | 0,253 | 273 | 268 |
3×150 | se/sm | 1,4 | 41,2 | 1305,0 | 1916 | 0,206 | 311 | 300 |
3×185 | se/sm | 1,6 | 45,7 | 1609,5 | 2347 | 0,164 | 360 | 342 |
3×240 | se/sm | 1,7 | 51,6 | 2088,0 | 2987 | 0,125 | 427 | 398 |
3×300 | se/sm | 1,8 | 56,7 | 2160,0 | 3663 | 0,100 | 507 | 457 |
FOUR – CORE CABLES | ||||||||
NOMINAL CROSS SECTION | CONDUCTOR CONSTRUCTION | NOM. THICKNESS OF INSUL. | OUTER DIAM. (APPROX.) | METAL WEIGHT | CABLE WEIGHT (APPROX.) | MAX. RESISTANCE AT 20°C | CURRENT CAPACITY IN AIR | CURRENT CAPACITY IN EARTH |
mm2 | mm | mm | kg/km | kg/km | ohm/km | A | A | |
3×70+35 | sm/sm | 1,1/0,9 | 28,8 | 655,4 | 935 | 0,443/0,868 | 191 | 196 |
3×95+50 | sm/sm | 1,1/1,0 | 32,2 | 899,0 | 1120 | 0,320/0,641 | 234 | 234 |
3×120+70 | sm/sm | 1,2/1,1 | 34,6 | 1145,5 | 1430 | 0,253/0,443 | 273 | 268 |
3×150+70 | sm/sm | 1,4/1,1 | 38,5 | 1450,0 | 1950 | 0,206/0,443 | 311 | 300 |
3×185+95 | sm/sm | 1,6/1,1 | 42,4 | 1812,5 | 2345 | 0,164/0,320 | 360 | 342 |
3×240+120 | sm/sm | 1,7/1,2 | 47,2 | 2363,5 | 2980 | 0,125/0,253 | 427 | 398 |
4×35 | sm | 0,9 | 25,9 | 406,0 | 690 | 0,868 | 126 | 135 |
4×50 | se/sm | 1,0 | 28,4 | 580,0 | 832 | 0,641 | 149 | 158 |
4×70 | se/sm | 1,1 | 32,4 | 812,0 | 1234 | 0,443 | 191 | 196 |
4×95 | se/sm | 1,1 | 35,6 | 1102,0 | 1460 | 0,320 | 234 | 234 |
4×120 | se/sm | 1,2 | 40,6 | 1392,0 | 1861 | 0,253 | 273 | 268 |
4×150 | se/sm | 1,4 | 44,8 | 1740,0 | 2386 | 0,206 | 311 | 300 |
4×185 | se/sm | 1,6 | 49,2 | 2146,0 | 2866 | 0,164 | 360 | 342 |
4×240 | se/sm | 1,7 | 54,9 | 2784,0 | 3616 | 0,125 | 427 | 398 |
4×300 | se/sm | 1,8 | 58,8 | 3480,0 | 4500 | 0,100 | 507 | 457 |
FOUR – CORE CABLES WITH CONTROL CONDUCTOR | ||||||||
NOMINAL CROSS SECTION | CONDUCTOR CONSTRUCTION | NOM. THICKNESS OF INSUL. | OUTER DIAM. (APPROX.) | METAL WEIGHT | CABLE WEIGHT (APPROX.) | MAX. RESISTANCE AT 20°C | CURRENT CAPACITY IN AIR | CURRENT CAPACITY IN EARTH |
mm2 | mm | mm | kg/km | kg/km | ohm/km | A | A | |
4×16+1,5 | re/rm | 0,7 | 22,1 | 185,6 | 615 | 1,910 | – | – |
4×25+1,5 | re/rm | 0,9 | 26,2 | 290,0 | 870 | 1,200 | 102 | 112 |
4×35+1,5 | re/rm | 0,9 | 28,9 | 406,0 | 1074 | 0,868 | 126 | 135 |
4×35+1,5 | sm | 0,9 | 23,1 | 406,0 | 630 | 0,868 | 126 | 135 |
4×50+1,5 | se/sm | 1,0 | 26,0 | 580,0 | 847 | 0,641 | 149 | 158 |
4×70+1,5 | se/sm | 1,1 | 30,0 | 812,0 | 1135 | 0,443 | 191 | 196 |
4×95+1,5 | se/sm | 1,1 | 33,6 | 1102,0 | 1480 | 0,320 | 234 | 234 |
4×120+1,5 | se/sm | 1,2 | 37,3 | 1392,0 | 1826 | 0,253 | 273 | 268 |
4×150+1,5 | se/sm | 1,4 | 42,0 | 1740,0 | 2282 | 0,206 | 311 | 300 |
4×185+1,5 | se/sm | 1,6 | 46,3 | 2146,0 | 2766 | 0,164 | 360 | 342 |
4×240+1,5 | se/sm | 1,7 | 52,1 | 2784,0 | 3572 | 0,125 | 427 | 398 |
4×300+1,5 | se/sm | 1,8 | 56,8 | 3480,0 | 4374 | 0,100 | 507 | 457 |
SIGNAL CU WIRE: Nominal cross section: 1,5 mm² Max. resistance at 20°C :12,1 Ω/km Nom. thicknss of insul. :0,7mm Outer diameter :2,9mm
FIVE – CORE CABLES | ||||||||
NOMINAL CROSS SECTION | CONDUCTOR CONSTRUCTION | NOM. THICKNESS OF INSUL. | OUTER DIAM. (APPROX.) | METAL WEIGHT | CABLE WEIGHT (APPROX.) | MAX. RESISTANCE AT 20°C | CURRENT CAPACITY IN AIR | CURRENT CAPACITY IN EARTH |
mm2 | mm | mm | kg/km | kg/km | ohm/km | A | A | |
5×16 | rm | 0,7 | 23,4 | 232,0 | 625 | 1,910 | – | – |
5×25 | rm | 0,9 | 28,2 | 362,5 | 950 | 1,200 | 102 | 112 |
5×35 | rm | 0,9 | 31,0 | 507,5 | 1195 | 0,868 | 126 | 135 |
5×50 | rm | 1,0 | 36,8 | 725,0 | 1540 | 0,641 | 149 | 158 |
5×70 | rm | 1,1 | 42,8 | 1015,0 | 2240 | 0,443 | 191 | 196 |
5×95 | rm | 1,1 | 48,5 | 1377,5 | 3015 | 0,320 | 234 | 234 |
5×120 | rm | 1,2 | 53,6 | 1740,0 | 3580 | 0,253 | 273 | 268 |
NA2XH CABLE SELECTION:
In addition to our portfolio of European power cables we also supply British standard low voltage power cables including armoured cable with its LSZH outer sheathing. Our technical has a wealth of experience in providing support in the selection of the right cable for your application. Please call to discuss your specific application.
If you have another question, pls feel free to contact us below
We are China Aluminum Conductor XLPE Insulated and Hffr Sheath Na2xh Power Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Aluminum Conductor XLPE Insulated and Hffr Sheath Na2xh Power Cable Products
Popular Na2xh Cable Products
Na2xh 0.6/1 K Al Conductors XLPE Insulated and Hffr Sheathed Aluminum Cable
AC2xh Na2xh XLPE Insulated Halogen Free Power Cable
Popular Power Cable Products
1000V Nayy Nayy J Yjv VV Swa Sta Armoured VDE Standard Power Cable XLPE Cable
Ynky, Power Cable, 0.6/1 Kv, High Flame Retardant Cu/PVC/PVC (IEC 60502-1)
0.6/1kv PVC Insulated Armoured Electrical Cable with Aluminum or Copper Conductor Power Cable
4 Core 120mm Copper/Aluminum XLPE Insulated Armoured Power Cable
Popular zzhongdacable Products
Overhead Application and Stranded Conductor Type 2.5mm Electric Wire
35mm2 50mm2 70mm2 95mm2 120mm2 150mm2 Single Aluminum Core Cable
Aerial Insulated Cable Street Light Overhead Cable 2 X 2 + 1/0 AWG
XLPE Quadruplex Aluminum Aerial Bundle ABC Cable Barnacle 2*4+4AWG
PVC Insulated Non-Sheathed Electric Wire
600V Cathodic Protection Kynar PVDF / Hmwpe Cable Wire
Tags: Aluminum Conductor XLPE Insulated and Hffr Sheath Na2xh Power Cable, Na2xh Cable, Power Cable, zzhongdacable