AC2xh Na2xh XLPE Insulated Halogen Free Power Cable
AC2xh Na2xh XLPE Insulated Halogen Free Power Cable image
Get Latest Price Request a quote
- Overview
- Product Description
- Product Parameters
Basic Info.
Product Description
AC2XH NA2XH XLPE Insulated halogen free power cable
Application:
In earth, ducts, on support brackets, in dry and wet conditions etc., where one does not expect mechanical damages and the cables are not exposed to the mechanical tensile strain. In urban networks, industrial plants, electric power plants and other electricity consumers and for connection of control devices in industry, traffic etc.
NA2XH CABLE CONSTRUCTION:
Conductors: Al, class 1 (RE/SE) or class 2 (RM/SM) according to EN 60228
Insulation: XLPE compound DIX 3
Bedding: Extruded elastomere or plastomere compound or plastic tape
Sheath: HFFR compound HM 4
Technical data:
CPR class: Eca
Test voltage: 4 kV
Rated voltage: 0,6/1,0 kV
Bending radius (min): single-core – 15D;
multicore – 12D
Min. laying temperature: -5°C
Max. conductor temperature: 90°C
Max. short-circuit temperature: 250°C
Industry: Building & Construction, Transmission, Distribution & Power Networks
Standard: IEC 60502-1, SI 1516-1
Type: Industrial Cable, LSZH Cable, Power Network & Local Distribution Cable
NA2XH CABLE DIMENSION:
| SINGLE – CORE CABLES: | ||||||||
| NOMINAL CROSS SECTION | CONDUCTOR CONSTRUCTION | NOM. THICKNESS OF INSUL. | OUTER DIAM. (APPROX.) | METAL WEIGHT | CABLE WEIGHT (APPROX.) | MAX. RESISTANCE AT 20°C | CURRENT CAPACITY IN AIR | CURRENT CAPACITY IN EARTH |
| mm2 | mm | mm | kg/km | kg/km | ohm/km | A | A | |
| 1×16 | rm | 0,7 | 9,5 | 46,2 | 122 | 1,910 | – | – |
| 1×25 | rm | 0,9 | 11,9 | 72,5 | 175 | 1,200 | 106 | 114 |
| 1×35 | rm | 0,9 | 13,0 | 101,5 | 206 | 0,868 | 130 | 136 |
| 1×50 | rm | 1,0 | 14,9 | 145,0 | 267 | 0,641 | 161 | 162 |
| 1×70 | rm | 1,1 | 17,0 | 203,0 | 358 | 0,443 | 204 | 199 |
| 1×95 | rm | 1,1 | 18,9 | 275,5 | 451 | 0,320 | 252 | 238 |
| 1×120 | rm | 1,2 | 20,7 | 348,0 | 546 | 0,253 | 295 | 272 |
| 1×150 | rm | 1,4 | 22,7 | 435,0 | 655 | 0,206 | 339 | 305 |
| 1×185 | rm | 1,6 | 25,1 | 536,5 | 800 | 0,164 | 395 | 347 |
| 1×240 | rm | 1,7 | 27,6 | 696,0 | 987 | 0,125 | 472 | 404 |
| 1×300 | rm | 1,8 | 31,9 | 870,0 | 1324 | 0,100 | 547 | 457 |
| 1×400 | rm | 2,0 | 34,9 | 1160,0 | 1640 | 0,0778 | 643 | 525 |
| 1×500 | rm | 2,2 | 39,3 | 1450,0 | 2030 | 0,0605 | 754 | 601 |
| 1×630 | rm | 2,4 | 44,1 | 1827,0 | 2400 | 0,0469 | 882 | 687 |
| 1×800 | rm | 2,6 | 46,5 | 2320,0 | 2505 | 0,0367 | 1019 | 776 |
| 1×1000 | rm | 2,8 | 52,0 | 2900,0 | 3115 | 0,0291 | 1157 | 865 |
| THREE – CORE CABLES: | ||||||||
| NOMINAL CROSS SECTION | CONDUCTOR CONSTRUCTION | NOM. THICKNESS OF INSUL. | OUTER DIAM. (APPROX.) | METAL WEIGHT | CABLE WEIGHT (APPROX.) | MAX. RESISTANCE AT 20°C | CURRENT CAPACITY IN AIR | CURRENT CAPACITY IN EARTH |
| mm2 | mm | mm | kg/km | kg/km | ohm/km | A | A | |
| 3×16 | rm | 0,7 | 16,5 | 139,2 | 397 | 1,910 | – | – |
| 3×25 | rm | 0,9 | 20,0 | 217,5 | 587 | 1,200 | 102 | 112 |
| 3×35 | rm/sm | 0,9 | 22,5 | 304,5 | 531 | 0,868 | 126 | 135 |
| 3×50 | rm | 1,0 | 27,6 | 435,0 | 1007 | 0,641 | 149 | 158 |
| 3×70 | rm | 1,1 | 30,6 | 609,0 | 1401 | 0,443 | 191 | 196 |
| 3×95 | rm | 1,1 | 33,8 | 826,5 | 1801 | 0,320 | 234 | 234 |
| 3×120 | rm | 1,2 | 37,5 | 1044,0 | 2226 | 0,253 | 273 | 268 |
| 3×50 | se/sm | 1,0 | 26,0 | 435,0 | 720 | 0,641 | 149 | 158 |
| 3×70 | se/sm | 1,1 | 29,7 | 609,0 | 963 | 0,443 | 191 | 196 |
| 3×95 | se/sm | 1,1 | 33,4 | 826,5 | 1246 | 0,320 | 234 | 234 |
| 3×120 | se/sm | 1,2 | 37,1 | 1044,0 | 1545 | 0,253 | 273 | 268 |
| 3×150 | se/sm | 1,4 | 41,2 | 1305,0 | 1916 | 0,206 | 311 | 300 |
| 3×185 | se/sm | 1,6 | 45,7 | 1609,5 | 2347 | 0,164 | 360 | 342 |
| 3×240 | se/sm | 1,7 | 51,6 | 2088,0 | 2987 | 0,125 | 427 | 398 |
| 3×300 | se/sm | 1,8 | 56,7 | 2160,0 | 3663 | 0,100 | 507 | 457 |
| FOUR – CORE CABLES | ||||||||
| NOMINAL CROSS SECTION | CONDUCTOR CONSTRUCTION | NOM. THICKNESS OF INSUL. | OUTER DIAM. (APPROX.) | METAL WEIGHT | CABLE WEIGHT (APPROX.) | MAX. RESISTANCE AT 20°C | CURRENT CAPACITY IN AIR | CURRENT CAPACITY IN EARTH |
| mm2 | mm | mm | kg/km | kg/km | ohm/km | A | A | |
| 3×70+35 | sm/sm | 1,1/0,9 | 28,8 | 655,4 | 935 | 0,443/0,868 | 191 | 196 |
| 3×95+50 | sm/sm | 1,1/1,0 | 32,2 | 899,0 | 1120 | 0,320/0,641 | 234 | 234 |
| 3×120+70 | sm/sm | 1,2/1,1 | 34,6 | 1145,5 | 1430 | 0,253/0,443 | 273 | 268 |
| 3×150+70 | sm/sm | 1,4/1,1 | 38,5 | 1450,0 | 1950 | 0,206/0,443 | 311 | 300 |
| 3×185+95 | sm/sm | 1,6/1,1 | 42,4 | 1812,5 | 2345 | 0,164/0,320 | 360 | 342 |
| 3×240+120 | sm/sm | 1,7/1,2 | 47,2 | 2363,5 | 2980 | 0,125/0,253 | 427 | 398 |
| 4×35 | sm | 0,9 | 25,9 | 406,0 | 690 | 0,868 | 126 | 135 |
| 4×50 | se/sm | 1,0 | 28,4 | 580,0 | 832 | 0,641 | 149 | 158 |
| 4×70 | se/sm | 1,1 | 32,4 | 812,0 | 1234 | 0,443 | 191 | 196 |
| 4×95 | se/sm | 1,1 | 35,6 | 1102,0 | 1460 | 0,320 | 234 | 234 |
| 4×120 | se/sm | 1,2 | 40,6 | 1392,0 | 1861 | 0,253 | 273 | 268 |
| 4×150 | se/sm | 1,4 | 44,8 | 1740,0 | 2386 | 0,206 | 311 | 300 |
| 4×185 | se/sm | 1,6 | 49,2 | 2146,0 | 2866 | 0,164 | 360 | 342 |
| 4×240 | se/sm | 1,7 | 54,9 | 2784,0 | 3616 | 0,125 | 427 | 398 |
| 4×300 | se/sm | 1,8 | 58,8 | 3480,0 | 4500 | 0,100 | 507 | 457 |
| FOUR – CORE CABLES WITH CONTROL CONDUCTOR | ||||||||
| NOMINAL CROSS SECTION | CONDUCTOR CONSTRUCTION | NOM. THICKNESS OF INSUL. | OUTER DIAM. (APPROX.) | METAL WEIGHT | CABLE WEIGHT (APPROX.) | MAX. RESISTANCE AT 20°C | CURRENT CAPACITY IN AIR | CURRENT CAPACITY IN EARTH |
| mm2 | mm | mm | kg/km | kg/km | ohm/km | A | A | |
| 4×16+1,5 | re/rm | 0,7 | 22,1 | 185,6 | 615 | 1,910 | – | – |
| 4×25+1,5 | re/rm | 0,9 | 26,2 | 290,0 | 870 | 1,200 | 102 | 112 |
| 4×35+1,5 | re/rm | 0,9 | 28,9 | 406,0 | 1074 | 0,868 | 126 | 135 |
| 4×35+1,5 | sm | 0,9 | 23,1 | 406,0 | 630 | 0,868 | 126 | 135 |
| 4×50+1,5 | se/sm | 1,0 | 26,0 | 580,0 | 847 | 0,641 | 149 | 158 |
| 4×70+1,5 | se/sm | 1,1 | 30,0 | 812,0 | 1135 | 0,443 | 191 | 196 |
| 4×95+1,5 | se/sm | 1,1 | 33,6 | 1102,0 | 1480 | 0,320 | 234 | 234 |
| 4×120+1,5 | se/sm | 1,2 | 37,3 | 1392,0 | 1826 | 0,253 | 273 | 268 |
| 4×150+1,5 | se/sm | 1,4 | 42,0 | 1740,0 | 2282 | 0,206 | 311 | 300 |
| 4×185+1,5 | se/sm | 1,6 | 46,3 | 2146,0 | 2766 | 0,164 | 360 | 342 |
| 4×240+1,5 | se/sm | 1,7 | 52,1 | 2784,0 | 3572 | 0,125 | 427 | 398 |
| 4×300+1,5 | se/sm | 1,8 | 56,8 | 3480,0 | 4374 | 0,100 | 507 | 457 |
SIGNAL CU WIRE: Nominal cross section: 1,5 mm² Max. resistance at 20°C :12,1 Ω/km Nom. thicknss of insul. :0,7mm Outer diameter :2,9mm
| FIVE – CORE CABLES | ||||||||
| NOMINAL CROSS SECTION | CONDUCTOR CONSTRUCTION | NOM. THICKNESS OF INSUL. | OUTER DIAM. (APPROX.) | METAL WEIGHT | CABLE WEIGHT (APPROX.) | MAX. RESISTANCE AT 20°C | CURRENT CAPACITY IN AIR | CURRENT CAPACITY IN EARTH |
| mm2 | mm | mm | kg/km | kg/km | ohm/km | A | A | |
| 5×16 | rm | 0,7 | 23,4 | 232,0 | 625 | 1,910 | – | – |
| 5×25 | rm | 0,9 | 28,2 | 362,5 | 950 | 1,200 | 102 | 112 |
| 5×35 | rm | 0,9 | 31,0 | 507,5 | 1195 | 0,868 | 126 | 135 |
| 5×50 | rm | 1,0 | 36,8 | 725,0 | 1540 | 0,641 | 149 | 158 |
| 5×70 | rm | 1,1 | 42,8 | 1015,0 | 2240 | 0,443 | 191 | 196 |
| 5×95 | rm | 1,1 | 48,5 | 1377,5 | 3015 | 0,320 | 234 | 234 |
| 5×120 | rm | 1,2 | 53,6 | 1740,0 | 3580 | 0,253 | 273 | 268 |
NA2XH CABLE SELECTION:
In addition to our portfolio of European power cables we also supply British standard low voltage power cables including armoured cable with its LSZH outer sheathing. Our technical has a wealth of experience in providing support in the selection of the right cable for your application. Please call to discuss your specific application.
If you have another question, pls feel free to contact Vivian Yuan from Hongda Cable.
We are China AC2xh Na2xh XLPE Insulated Halogen Free Power Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular AC2xh Na2xh XLPE Insulated Halogen Free Power Cable Products
Popular Na2xh Cable Products
Na2xh 0.6/1 K Al Conductors XLPE Insulated and Hffr Sheathed Aluminum Cable
Aluminum Conductor XLPE Insulated and Hffr Sheath Na2xh Power Cable
Popular Power Cable Products
Copper Conductor Cables Wires PVC Insulation Electric Wire for Building or Constrction
Covered Aerial Tree Wire ACSR Conductor Overhead Power Cable
Aluminum Conductor Steel Reinforced-ACSR Cable
Cu/XLPE/Cts/PVC/Awa/PVC, Power Cable, 8.7/15 (17.5) Kv, 1/C (IEC 60502-2)
2X25mm2 Copper Conductor XLPE Insulated Anti Termite and Rodent PVC Sheahted Power Cable
Flexible 0.6/1kv Cu/XLPE/PVC Electrical Power Cable
Popular zzhongdacable Products
H07z-U H07z-R H07z-K Halogen Free Single Core Wire Lsoh PVC Flexible Cable
RS-485 Cable 2 Pair 1.5mm Swa Industrial Signal Communication Cable
H1z2z2-K Cable Tinned Copper Xlpo Insulated Xlpo Sheathed Solar Cable
4X70 Cable Aluminium XLPE Cable 4 Core Power Cable 70mm2 0.6/1kv
AAAC Bare Conductor XLPE Alambre Triplex 2/0 4/0 Service Drop Cable
Tags: AC2xh Na2xh XLPE Insulated Halogen Free Power Cable, Na2xh Cable, Power Cable, zzhongdacable