Triplex Service Drop Aluminium Cable
Triplex Service Drop Aluminium Cable image
Get Latest Price Request a quote
Quick Details
Product Details
Construction
Concentric strand or compressed 1350-H19 conductor, polyethylene or crosslinked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy neutral messenger.
Standards
ASTM B-230, B-231, B-232 and B-339 & ICEA S-76-474
NOTE:
If you want to know more details about this kind of products, please visit our website(homepage) because we have no ways to show so much information on this platform. Thank you.
| Code Name |
Phase Conductor | Bare Neutral Messenger | Weight Per 1000 ft(lbs) |
Ampacity (Amps) | |||||||
| Size AWG |
Stranding | Insulation thickness (mls) |
Size AWG |
Stranding | Breaking strength (lbs) |
XLP | POLY | XLP | POLY | ||
| 6201 ALLOY NEUTRAL-MESSENGER | |||||||||||
| Minex | 6 | solid | 45 | 6 | 7 | 1,110 | 106.6 | 102.9 | 85 | 70 | |
| Hippa | 6 | 7/w | 45 | 6 | 7 | 1,110 | 113.2 | 105.7 | 85 | 70 | |
| Prawn | 4 | solid | 45 | 4 | 7 | 1,760 | 158.4 | 154.1 | 115 | 90 | |
| Barnacles | 4 | 7/w | 45 | 4 | 7 | 1,760 | 168.3 | 158.2 | 115 | 90 | |
| Shrimp | 2 | 7/w | 45 | 2 | 7 | 2,800 | 253.7 | 239.7 | 150 | 120 | |
| Gammarus | 1/0 | 7/w | 60 | 1/0 | 7 | 4,460 | 411.7 | 386.0 | 205 | 160 | |
| Leda | 1/0 | 19/w | 60 | 1/0 | 7 | 4,460 | 402.7 | 386.0 | 205 | 160 | |
| Dungenese | 2/0 | 7/w | 60 | 2/0 | 7 | 5,390 | 506.8 | 476.3 | 235 | 185 | |
| Cyclops | 2/0 | 19/w | 60 | 2/0 | 7 | 5,390 | 495.3 | 476.3 | 235 | 185 | |
| Flustra | 3/0 | 19/w | 60 | 3/0 | 7 | 6,790 | 611.4 | 589.1 | 275 | 215 | |
| Lepas | 4/0 | 19/w | 60 | 4/0 | 7 | 8,560 | 757.1 | 730.5 | 315 | 245 | |
| 6201 ALLOY REDUCED NEUTRAL-MESSENGER | |||||||||||
| Artemia | 4 | solid | 45 | 6 | 7 | 1,110 | 141.4 | 137.1 | 115 | 90 | |
| Crab | 4 | 7/w | 45 | 6 | 7 | 1,110 | 151.3 | 141.2 | 115 | 90 | |
| Solaster | 2 | 7/w | 45 | 4 | 7 | 1,760 | 226.6 | 212.6 | 150 | 120 | |
| Sandcrab | 1/0 | 7/w | 60 | 2 | 7 | 2,800 | 368.8 | 343.1 | 205 | 160 | |
| Echinus | 1/0 | 19/w | 60 | 2 | 7 | 2,800 | 358.8 | 343.1 | 205 | 160 | |
| Crayfish | 2/0 | 7/w | 60 | 1 | 7 | 3,530 | 452.6 | 422.5 | 235 | 185 | |
| Sipho | 2/0 | 19/w | 60 | 1 | 7 | 3,530 | 441.0 | 422.5 | 235 | 185 | |
| Fulgar | 3/0 | 19/w | 60 | 1/0 | 7 | 4,460 | 543.4 | 521.1 | 275 | 215 | |
| Arca | 4/0 | 19/w | 60 | 2/0 | 7 | 5,390 | 671.2 | 644.6 | 315 | 245 | |
| Code Name |
Phase Conductors | Bare Neutral | Weight Per 1000 ft.(lbs) |
Ampacity(Amps) | |||||||
| Size AWG or MCM |
Stranding | Insulation thickness (mls) |
Size (AWG) |
*Stranding | Rated strength (lbs) |
XLP | Poly | XLP | Poly | ||
| AAC NEUTRAL-MESSENGER | |||||||||||
| Haiotis | 6 | solid | 45 | 6 | 7 | 563 | 102.5 | 98.8 | 85 | 70 | |
| Patella | 6 | 7/w | 45 | 6 | 7 | 563 | 109.1 | 101.6 | 85 | 70 | |
| Fusus | 4 | solid | 45 | 4 | 7 | 881 | 151.9 | 147.6 | 115 | 90 | |
| Oyster | 4 | 7/w | 45 | 4 | 7 | 881 | 161.8 | 151.7 | 115 | 90 | |
| Clam | 2 | 7/w | 45 | 2 | 7 | 1,350 | 243.2 | 229.2 | 150 | 120 | |
| Murex | 1/0 | 7/w | 60 | 1/0 | 7 | 1,990 | 395.1 | 369.4 | 205 | 160 | |
| Purpura | 1/0 | 19/w | 60 | 1/0 | 7 | 1,990 | 386.1 | 369.4 | 205 | 160 | |
| Nassa | 2/0 | 7/w | 60 | 2/0 | 7 | 2,510 | 485.8 | 455.3 | 235 | 185 | |
| Melita | 3/0 | 19/w | 60 | 3/0 | 19 | 3,310 | 585.2 | 562.9 | 275 | 215 | |
| Portunus | 4/0 | 19/w | 60 | 4/0 | 19 | 4,020 | 723.9 | 697.3 | 315 | 245 | |
| Nannynose | 336.4 | 19/w | 80 | 336.4 | 19 | 6,146 | 1160.4 | 1118.0 | 420 | 325 | |
| WITH FULL SIZE ACSR MESSENGER | |||||||||||
| Paludina | 6 | solid | 45 | 6 | 6/1 | 1,190 | 114 | 113 | 85 | 70 | |
| Voluta | 6 | 7/w | 45 | 6 | 6/1 | 1,190 | 120 | 113 | 85 | 70 | |
| Whelk | 4 | solid | 45 | 4 | 6/1 | 1,860 | 169 | 165 | 115 | 90 | |
| Periwinkle | 4 | 7/w | 45 | 4 | 6/1 | 1,860 | 176 | 172 | 115 | 90 | |
| Conch | 2 | 7/w | 45 | 2 | 6/1 | 2,850 | 267 | 261 | 150 | 120 | |
| Neritina | 1/0 | 7/w | 60 | 1/0 | 6/1 | 4,380 | 530 | 419 | 205 | 160 | |
| Cenia | 1/0 | 19/w | 60 | 1/0 | 6/1 | 4,380 | 426 | 416 | 205 | 160 | |
| Runcina | 2/0 | 7/w | 60 | 2/0 | 6/1 | 5,310 | 530 | 519 | 235 | 185 | |
| Triton | 2/0 | 19/w | 60 | 2/0 | 6/1 | 5,310 | 526 | 514 | 235 | 185 | |
| Cherrystone | 3/0 | 7/w | 60 | 3/0 | 6/1 | 6,620 | 656 | 643 | 250 | 200 | |
| Mursia | 3/0 | 19/w | 60 | 3/0 | 6/1 | 6,620 | 650 | 638 | 250 | 200 | |
| Razor | 4/0 | 7/w | 60 | 4/0 | 6/1 | 8,350 | 814 | 799 | 315 | 245 | |
| Zuzara | 4/0 | 19/w | 60 | 4/0 | 6/1 | 8,350 | 805 | 792 | 315 | 245 | |
| Limpet | 336.4 | 19/w | 80 | 336.4 | 18/1 | 8,680 | 1209 | 1167 | 420 | 325 | |
| Code Name |
Phase Conductors | Bare Neutral | Weight Per 1000 ft.(lbs) |
Ampacity(Amps) | |||||||
| SizeAWGor MCM | Stranding | Insulation thickness (mls) |
Size (AWG) |
Stranding | Rated strength (lbs) |
XLP | Poly | XLP | Poly | ||
| WITH ACSR REDUCED SIZE MESSENGER | |||||||||||
| Scallop | 4 | Solid | 45 | 6 | 6/1 | 1,190 | 148 | 144 | 115 | 90 | |
| Strombus | 4 | 7/w | 45 | 6 | 6/1 | 1,190 | 158 | 148 | 115 | 90 | |
| Cockle | 2 | 7/ w | 45 | 4 | 6/1 | 1,860 | 233 | 227 | 150 | 120 | |
| Janthina | 1/0 | 7/ w | 60 | 2 | 6/1 | 2,850 | 376 | 365 | 205 | 160 | |
| Ranella | 1/0 | 19/ w | 60 | 2 | 6/1 | 2,850 | 372 | 362 | 205 | 160 | |
| Cavolinia | 2/0 | 7/ w | 60 | 1 | 6/1 | 3,550 | 462 | 451 | 235 | 185 | |
| Clio | 2/0 | 19/ w | 60 | 1 | 6/1 | 3,550 | 458 | 446 | 235 | 185 | |
| Sanddollar | 3/0 | 7/ w | 60 | 1/0 | 6/1 | 4,380 | 570 | 557 | 275 | 215 | |
| Aega | 3/0 | 19/ w | 60 | 1/0 | 6/1 | 4,380 | 565 | 552 | 275 | 215 | |
| Cuttlefish | 4/0 | 7/ w | 60 | 2/0 | 6/1 | 5,310 | 706 | 691 | 315 | 245 | |
| Cerapus | 4/0 | 19/ w | 60 | 2/0 | 6/1 | 5,310 | 699 | 684 | 315 | 245 | |
| Cowry | 336.4 | 19/ w | 80 | 4/0 | 6/1 | 8,350 | 1135 | 1093 | 420 | 325 | |
We are China Triplex Service Drop Aluminium Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular ABC Cable Products
XLPE Insulated ABC Cable Aluminum Core Industrial Cable
Manufacture AAC AAAC Conductor XLPE Insulated 0.6/1kv ABC Cable
Overhead Conductor AAAC Without Insulation Material
Overhead Insulated Aerial Bundle Service Drop Triplex ABC Cable
Triplex XLPE 4/0AWG+4/0AWG Bare Aluminum Alloy Conductor
4 Cores 50 Sqmm Overhead ABC Aerial Bundled Cable
Popular jytopcable Products
Duplex Triplex Twisted Aluminum Conductor XLPE Insulated ABC Cable
RV-K Class 5 Flexible Copper Conductor XLPE Insulated PVC Cable
PVC Insulated Electric Wire for H05V-U
High Efficiency ACSR Bare Conductor (BS 215- PART2)
2.5mm Copper PVC Coated Electrical Housing Wire & Cable
1kv Nyfy Nyry Electrical Cable Low Voltage LV Nyry Nyfy Electric Cable 4X95sq. Mm
Popular Overhead Cable Products
Aluminum Conductor Shepherd XLPE Insulation Twisted Overhead Cable Duplex ABC Cable
0.6/1kv Overhead Cable Aerial Bundled Cables with Lighting Core
Twisted Cables 4X16mm Overhead Aerial Bundled Cable Electrical Cable
Overhead Transmission Aluminium Cable Duplex Service Drop ABC Cable
Overhead Power Transmission Steel Core Bare Cable Aluminum ACSR Conductor
Popular Triplex Cable Products
Triplex Service Drop Cable ABC
Service Entrance Cable Triplex Arca 4/0 AWG AAC/XLPE/PE+2/0 AWG AAAC Naked
Triplex Sevice Drop (ABC) Cable
2 AWG Aluminum Triplex Aluminum Triplex Service Drop Cable ABC Cable (ABC, JKLYJ, JKLV)
Top Quality Aerial Bundled Cable for Power Transmission with Multi-Size
2X16 mm² Aerial Connection Cable, Alu - NFC 33 209
Tags: ABC Cable, jytopcable, Overhead Cable, Triplex Cable