0.6/1kv Copper Conductor XLPE Insulated PVC Sheathed Power Cable
0.6/1kv Copper Conductor XLPE Insulated PVC Sheathed Power Cable image
Get Latest Price Request a quote
Quick Details
Product Details
0.6/1kv Copper Conductor XLPE Insulated PVC Sheathed Power Cable
Standard:
IEC60502,and BS6346, VDE, AS/NZS, UL,etc or as customer’s request.
The Rated Voltage(kv):
1st class 0.6/1 1.8/3 3.6/6 6/10 8.7/15 12/20 18/30 21/35
2nd class 1/1 3/3 6/6 8.7/10 12/15 18/20 – 26/35
Application:
Power cable are most suitable for direct burial or for installation on trays or ducts, Where there is
a risk of mechanical damage, armoured cables should be used.
|
TYPE |
NAME |
Main Application |
|
|
CU core |
AL core |
|
|
|
YJV/YJY |
YJLV/YJLY |
XLPE insulated,PVC/PE sheathed power cable |
For laying indoor ,tunnel,canal and underground. |
|
YJV22/YJV23 |
YJLV22/YJLV23 |
XLPE insulated,steel tape armored, |
For laying indoor ,tunnel,canal and underground. |
|
YJV32/YJV33 |
YJLV32/YJLV33 |
XLPE insulated,thin steel wire armored, |
For laying in shaft,water underground will large difference of level. |
|
YJV42/YJV43 |
YJLV42/YJLV43 |
XLPE insulated,thick steel wire armored, |
For laying in water and seabed. |
Number of cores:
1core 2core 3core 3+1core 4core 4+1core 4+2core 5core and so on.
Nominal Section
Area(mm2) :1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 800
Features:
1). XLPE insulated power cable not only has excellent electric, mechanical properties, but also has powerful resistance against chemical erosion, heat-aging and environmental stress.
2) .Its structures are simple. The long term operating temperature is +90 degrees. It is convenient to use and can be laid with no restriction of different level.
3). Our XLPE cables can be produced according to our specification which is equivalent to IEC 502-1983, and its some indexes are superior to 502-1983.
4). We can design and manufacture special XLPE cable according to the other standards required by the customers.
5).Application: for laying indoor, tunnel, canal and underground.
| Nominal Cross Section |
Diameter of Conductor (Approx.) |
Nominal Insulation thickness |
Nominal Inner Covering thickness |
Nominal Alum Wire dia. |
Nominal Sheath thickness |
Overall Diameter (Approx.) |
| mm² | mm | mm | mm | mm | mm | mm |
| 1×4 | 2.3 | 0.7 | 1 | 0.8 | 1.8 | 10.9 |
| 1×6 | 2.8 | 0.7 | 1 | 0.8 | 1.8 | 11.4 |
| 1×10 | 3.6 | 0.7 | 1 | 0.8 | 1.8 | 12.2 |
| 1×16 | 4.5 | 0.7 | 1 | 0.8 | 1.8 | 13.1 |
| 1×25 | 5.6 | 0.9 | 1 | 0.8 | 1.8 | 14.6 |
| 1×35 | 6.7 | 0.9 | 1 | 1.25 | 1.8 | 16.6 |
| 1×50 | 8 | 1 | 1 | 1.25 | 1.8 | 18.1 |
| 1×70 | 9.4 | 1.1 | 1 | 1.25 | 1.8 | 19.7 |
| 1×95 | 11 | 1.1 | 1 | 1.6 | 1.8 | 22 |
| 1×120 | 12.4 | 1.2 | 1 | 1.6 | 1.8 | 23.6 |
| 1×150 | 13.8 | 1.4 | 1 | 1.6 | 1.8 | 25.4 |
| 1×185 | 15.3 | 1.6 | 1 | 1.6 | 1.8 | 27.4 |
| 1×240 | 17.5 | 1.7 | 1 | 1.6 | 1.9 | 29.9 |
| 1×300 | 19.5 | 1.8 | 1 | 2 | 2 | 33.1 |
| 1×400 | 22.6 | 2 | 1.2 | 2 | 2.2 | 37.3 |
| 1×500 | 25.2 | 2.2 | 1.2 | 2 | 2.3 | 40.5 |
| Nominal Cross Section |
Diameter of Conductor (Approx.) |
Nominal Insulation thickness |
Nominal Inner Covering thickness |
Nominal Steel Wire dia. |
Nominal Sheath thickness |
Overall Diameter (Approx.) |
| mm² | mm | mm | mm | mm | mm | mm |
| 2×1.5 | 1.4 | 0.7 | 1 | 0.8 | 1.8 | 12.8 |
| 2×2.5 | 1.8 | 0.7 | 1 | 0.8 | 1.8 | 13.6 |
| 2×4 | 2.3 | 0.7 | 1 | 0.8 | 1.8 | 14.6 |
| 2×6 | 2.8 | 0.7 | 1 | 1.25 | 1.8 | 16.5 |
| 2×10 | 3.6 | 0.7 | 1 | 1.25 | 1.8 | 18.1 |
| 2×16 | 4.5 | 0.7 | 1 | 1.25 | 1.8 | 19.9 |
| 2×25 | 5.6 | 0.9 | 1 | 1.6 | 1.8 | 23.6 |
| 2×35 | 6.7 | 0.9 | 1 | 1.6 | 1.8 | 25.8 |
| 2×50 | 8 | 1 | 1 | 1.6 | 1.9 | 29 |
| 2×70 | 9.4 | 1.1 | 1 | 2 | 2 .3 | 3.2 |
| 2×95 | 11 | 1.1 | 1.2 | 2.1 | 3 | 7.1 |
| 2×120 | 12.4 | 1.2 | 1.2 | 2 | 2.3 | 40.5 |
| 2×150 | 13.8 | 1.4 | 1.2 | 2.5 | 2.4 | 45.4 |
| 2×185 | 15.3 | 1.6 | 1.4 | 2.5 | 20.6 | 49.9 |
| 2×240 | 17.5 | 1.7 | 1.4 | 2.5 | 20.7 | 55.1 |
| 2×300 | 19.5 | 1.8 | 1.6 | 2.5 | 20.9 | 60.2 |
| 2×400 | 22.6 | 2 | 1.6 | 2.5 | 30.1 | 67.7 |
| Nominal Cross Section |
Diameter of Conductor (Approx.) |
Nominal Insulation thickness |
Nominal Inner Covering thickness |
Nominal Steel Wire dia. |
Nominal Sheath thickness |
Overall Diameter (Approx.) |
| mm² | mm | mm | mm | mm | mm | mm |
| 3×1.5 | 1.4 | 0.7 | 1 | 0.8 | 1.8 | 13.2 |
| 3×2.5 | 1.8 | 0.7 | 1 | 0.8 | 1.8 | 14.1 |
| 3×4 | 2.3 | 0.7 | 1 | 0.8 | 1.8 | 15.2 |
| 3×6 | 2.8 | 0.7 | 1 | 1.25 | 1.8 | 17.1 |
| 3×10 | 3.6 | 0.7 | 1 | 1.25 | 1.8 | 18.9 |
| 3×16 | 4.5 | 0.7 | 1 | 1.25 | 1.8 | 20.8 |
| 3×25 | 5.6 | 0.9 | 1 | 1.6 | 1.8 | 24.7 |
| 3×35 | 6.7 | 0.9 | 1 | 1.6 | 1.8 | 27.2 |
| 3×50 | 8 | 1 | 1 | 1.6 | 1.9 | 30.6 |
| 3×70 | 9.4 | 1.1 | 1 | 2 | 2.1 | 35.2 |
| 3×95 | 11 | 1.1 | 1.2 | 2 | 2.2 | 39.3 |
| 3×120 | 12.4 | 1.2 | 1.2 | 2 | 2.3 | 43 |
| 3×150 | 13.8 | 1.4 | 1.4 | 2.5 | 2.5 | 48.6 |
| 3×185 | 15.3 | 1.6 | 1.4 | 2.5 | 2.7 | 53 |
| 3×240 | 17.5 | 1.7 | 1.4 | 2.5 | 2.8 | 58.5 |
| 3×300 | 19.5 | 1.8 | 1.6 | 2.5 | 3 | 64 |
| 3×400 | 22.6 | 2 | 1.6 | 3.15 | 3.3 | 73.5 |
| Nominal Cross Section |
Diameter of Conductor (Approx.) |
Nominal Insulation thickness |
Nominal Inner Covering thickness |
Nominal Steel Wire dia. |
Nominal Sheath thickness |
Overall Diameter (Approx.) |
||
| mm² | mm | mm | mm | mm | mm | mm | mm | mm |
| 3x 16/10 | 4.5 | 3.6 | 0.7 | 0.7 | 1 | 1.6 | 1.8 | 22.7 |
| 3x 25/16 | 5.6 | 4.5 | 0.9 | 0.7 | 1 | 1.6 | 1.8 | 26.5 |
| 3x 35/16 | 6.7 | 4.5 | 0.9 | 0.7 | 1 | 1.6 | 1.9 | 29 |
| 3x 50/25 | 8 | 5.6 | 1 | 0.9 | 1 | 1.6 | 2.1 | 33 |
| 3x 70/35 | 9.4 | 6.7 | 1.1 | 0.9 | 1.2 | 2 | 2.2 | 38 |
| 3x 95/50 | 11 | 8 | 1.1 | 1 | 1.2 | 2 | 2.3 | 42.4 |
| 3×120/70 | 12.4 | 9.4 | 1.2 | 1.1 | 1.2 | 2 | 2.5 | 48 |
| 3×150/70 | 13.8 | 9.4 | 1.4 | 1.1 | 1.4 | 2.5 | 2.7 | 52 |
| 3×185/95 | 15.3 | 11 | 1.6 | 1.1 | 1.4 | 2.5 | 2.8 | 57.2 |
| 3×240/120 | 17.5 | 12.4 | 1.7 | 1.2 | 1.6 | 2.5 | 3.1 | 64 |
| 3×300/150 | 19.5 | 13.8 | 1.8 | 1.4 | 1.6 | 2.5 | 3.2 | 69.8 |
| Nominal Cross Section |
Diameter of Conductor (Approx.) |
Nominal Insulation thickness |
Nominal Inner Covering thickness |
Nominal Steel Wire dia. |
Nominal Sheath thickness |
Overall Diameter (Approx.) |
| mm² | mm | mm | mm | mm | mm | mm |
| 4×1.5 | 1.4 | 0.7 | 1 | 0.8 | 1.8 | 14 |
| 4×2.5 | 1.8 | 0.7 | 1 | 0.8 | 1.8 | 14.9 |
| 4×4 | 2.3 | 0.7 | 1 | 1.25 | 1.8 | 17 |
| 4×6 | 2.8 | 0.7 | 1 | 1.25 | 1.8 | 18.2 |
| 4×10 | 3.6 | 0.7 | 1 | 1.25 | 1.8 | 20.2 |
| 4×16 | 4.5 | 0.7 | 1 | 1.6 | 1.8 | 23 |
| 4×25 | 5.6 | 0.9 | 1 | 1.6 | 1.8 | 26.7 |
| 4×35 | 6.7 | 0.9 | 1 | 1.6 | 1.9 | 29.5 |
| 4×50 | 8 | 1 | 1 | 2 | 2.1 | 34.2 |
| 4×70 | 9.4 | 1.1 | 1.2 | 2 | 2.2 | 38.8 |
| 4×95 | 11 | 1.1 | 1.2 | 2 | 2.3 | 42.9 |
| 4×120 | 12.4 | 1.2 | 1.4 | 2.5 | 2.5 | 48.6 |
| 4×150 | 13.8 | 1.4 | 1.4 | 2.5 | 2.7 | 53.2 |
| 4×185 | 15.3 | 1.6 | 1.4 | 2.5 | 2.8 | 58.1 |
| 4×240 | 17.5 | 1.7 | 1.6 | 2.5 | 3.1 | 64.8 |
| 4×300 | 19.5 | 1.8 | 1.6 | 2.5 | 3.2 | 70.4 |
| 4×400 | 22.6 | 2 | 1.8 | 3.15 | 3.6 | 81.3 |
Packaging
Packing Details : Packing in wooden drum, iron-wooden drum or as customer’s requirement.
Delivery Details : 15-25 days after place an order.
We are China 0.6/1kv Copper Conductor XLPE Insulated PVC Sheathed Power Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular jytopcable Products
0.6-1kv XLPE Insulated Service Aerial Bundled Aluminum Overhead ABC Cable
All Aluminum Stranded Conductor AAC 70mm2
450/750V PVC Insulated (Non-sheathed) Cables to BS 6004
PVC Insulated and Sheathed Control Cable for Low Voltage
Manufacturer for 1kv PVC Insulated Control Cable to GB9330
0.6/1kv Multicore Electric Power Cable 5X35mm2
Popular Power Cable Products
Copper Conductor XLPE Insulated, Steel Tape Armored, PVC PE Sheathed Power Cable.
8.7/15kv Medium Voltage XLPE Insulated PVC Sheathed Armored Copper Power Cable
cUL Certificate 600V Copper or Aluminum RW90 Armoured Types AC90 Acwu90 Teck90 Cable
Factory Supplies High Quality Insulated PVC Sheath Power Cable (YJY) 0.6/1kv
PVC Insulation Armored Cable Fire Resistant Electrical Power Cable
240mm2 XLPE Insulated Steel Wire Armoured Power Cable
Popular PVC Sheathed Cable Products
N2xy-O/Na2xy-O Cu/PVC Power Cable to DIN/VDE 0276
N2X Ry-O/N2X Ry-J Cu/PVC Power Cable to DIN/VDE0276
Low Voltage XLPE Insulated PVC Sheathed Swa Copper Power Cable
3X50+2X25 mm2 3*120+1*70 Cable Yjv Cable XLPE Power Cable Swa PVC Armor Power Electric Cable
Low Smoke Halogen Free Mica XLPE Insulated Copper Cable for Hospital
Low Voltage XLPE Insulated PVC Sheathed Sta Copper Power Cable
Popular XLPE Insulated Cable Products
Yjv Yjlv 0.6/1kv Copper/Aluminum Core XLPE Insulated Steel Wire Armoured (SWA) Power Cable
Mv 3.6/6 (7.2) Kv XLPE Insulated Electric Wire Electric Cable Power Cable
ASTM Standard 1000V Duplex Triplex Quadruplex LV Service Entrance/Drop Cable
Power Cable with Copper Conductor and XLPE Insulated PVC Sheathed and Steel Tape Armored
0.6/1kv PVC Insulation Power Cable
Tags: jytopcable, Power Cable, PVC Sheathed Cable, XLPE Insulated Cable