ACSR Dog 100mm2 Bare Conductor for 11kv Distribution Network
ACSR Dog 100mm2 Bare Conductor for 11kv Distribution Network image
Get Latest Price Request a quote
Quick Details
Product Details
Simple structure / Easy installation and maintenance / Low circuit cost / Large transmission capacity / Good conductive performance / Sufficient mechanical strength / High tensile strength
ACSR Cable Advantage:
1. Convenient for laying across special geographical conditions such as rivers and valleys
2.The tower distance can be enlarged
ACSR Cable Application:
Widely used in overhead power transmission lines of various voltage levels
AAAC Cable Applications
AAAC Aluminum Alloy Conductor is Used as bare overhead conductor for primary and secondary distribution. Designed utilizing a high-strength aluminum alloy to achieve a high strength-to-weight ratio; affords better sag characteristics. Aluminum alloy gives higher resistance to corrosion than ACSR.
Standard
BS EN50183,IEC 61089, ASTM B399,BS 3242, DIN 48204,GB/T1179-2008
Specification
Physical contents of aluminum alloy :-
1. Resistivity – 0.0326 Ohms mm2/m at 20°C
2. Density – 2.70 kgm/dm3 at 20°C
3. Coefficient of Linear Expansion – 23 x 10-6 / °C
4. Constant Mass Temperature Coefficient (a) – 0.00360/ °C
5. Material – Heat treated Al. Mg. Si. Alloy
– Approximately 0.5% Mg & 0.5% Si
ASTM B399
| Code Name | Area | Size & Stranding of ACSR with Equal Diameter | No. & Diameter of wires | Overall Diameter | Weight | Nominal Breaking Load | ||
| Nominal | Actual | |||||||
| MCM | mm2 | AWG or MCM | Al/Steel | mm | mm | kg/km | kN | |
| Akron | 30.58 | 15.48 | 6 | 6/1 | 7/1.68 | 5.04 | 42.7 | 4.92 |
| Alton | 48.69 | 24.71 | 4 | 6/1 | 7/2.12 | 6.35 | 68.0 | 7.84 |
| Ames | 77.47 | 39.22 | 2 | 6/1 | 7/2.67 | 8.02 | 108 | 12.45 |
| Azusa | 123.3 | 62.38 | 1/0 | 6/1 | 7/3.37 | 10.11 | 172 | 18.97 |
| Anaheim | 155.4 | 78.65 | 2/0 | 6/1 | 7/3.78 | 11.35 | 217 | 23.93 |
| Amherst | 195.7 | 99.22 | 3/0 | 6/1 | 7/4.25 | 12.75 | 273 | 30.18 |
| Alliance | 246.9 | 125.1 | 4/0 | 6/1 | 7/4.77 | 14.31 | 345 | 38.05 |
| Butte | 312.8 | 158.6 | 266.8 | 26/7 | 19/3.26 | 16.30 | 437 | 48.76 |
| Canton | 394.5 | 199.9 | 336.4 | 26/7 | 19/3.66 | 18.30 | 551 | 58.91 |
| Cairo | 465.4 | 235.8 | 397.5 | 26/7 | 19/3.98 | 19.88 | 650 | 69.48 |
| Darien | 559.5 | 283.5 | 477.0 | 26/7 | 19/4.36 | 21.79 | 781 | 83.52 |
| Elgin | 652.4 | 330.6 | 556.5 | 26/7 | 19/4.71 | 23.54 | 911 | 97.42 |
| Flint | 740.8 | 375.3 | 636.0 | 26/7 | 37/3.59 | 25.16 | 1035 | 108.21 |
| Greely | 927.2 | 469.8 | 795.0 | 26/7 | 37/4.02 | 28.14 | 1295 | 135.47 |
IEC 61089
| Code Number | A2 Conductor | A3 Conductor | Max.D.C. Resistance of Conductor at 20ºC | ||||||||
| Number of Wires | Diameter of Wires | Diameter of Conductor | Approx. Weight | Rated Strength | Number of Wires | Diameter of Wires | Diameter of Conductor | Approx. Weight | Rated Strength | ||
| mm² | – | mm | mm | kg/km | daN | – | mm | mm | kg/km | daN | Ω/km |
| 16 | 7 | 1.83 | 5.49 | 50.4 | 5.43 | 7 | 1.84 | 5.52 | 50.8 | 6.04 | 1.7896 |
| 25 | 7 | 2.29 | 6.87 | 78.7 | 8.49 | 7 | 2.30 | 6.9 | 79.5 | 9.44 | 1.1453 |
| 40 | 7 | 2.89 | 8.67 | 125.9 | 13.58 | 7 | 2.91 | 8.73 | 127.1 | 15.1 | 0.7158 |
| 63 | 7 | 3.63 | 10.8 | 198.3 | 21.39 | 7 | 3.65 | 10.95 | 200.2 | 23.06 | 0.4545 |
| 100 | 19 | 2.78 | 13.9 | 316.3 | 33.95 | 19 | 2.79 | 13.95 | 319.3 | 37.76 | 0.2877 |
| 125 | 19 | 3.10 | 15.5 | 395.4 | 42.44 | 19 | 3.12 | 15.6 | 399.2 | 47.20 | 0.2302 |
| 160 | 19 | 3.51 | 17.55 | 506.1 | 54.32 | 19 | 3.53 | 17.65 | 511.0 | 58.56 | 0.1798 |
| 200 | 19 | 3.93 | 19.65 | 623.7 | 67.91 | 19 | 3.95 | 19.75 | 638.7 | 73.20 | 0.1439 |
| 250 | 19 | 4.39 | 21.95 | 790.8 | 84.68 | 19 | 4.41 | 22.05 | 798.4 | 91.50 | 0.1151 |
| 315 | 37 | 3.53 | 24.71 | 998.9 | 106.95 | 37 | 3.55 | 24.85 | 1008.4 | 115.29 | 0.0916 |
| 400 | 37 | 3.98 | 27.86 | 1268.4 | 135.81 | 37 | 4.0 | 28 | 1280.5 | 146.4o | 0.0721 |
| 450 | 37 | 4.22 | 29.54 | 1426.9 | 152.79 | 37 | 4.24 | 29.68 | 1440.5 | 164.70 | 0.0641 |
| 500 | 37 | 4.45 | 31.15 | 1585.5 | 169.76 | 37 | 4.47 | 31.29 | 1600.6 | 183.oo | 0.0577 |
| 560 | 61 | 3.67 | 33.03 | 1778.4 | 190.14 | 61 | 3.69 | 33.21 | 1795.3 | 204.95 | 0.0516 |
| 630 | 61 | 3.89 | 35.01 | 2000.7 | 213.90 | 61 | 3.91 | 35.19 | 2019.8 | 230.58 | 0.0458 |
| 710 | 61 | 4.13 | 37.17 | 2254.8 | 241.07 | 61 | 4.15 | 37.35 | 2276.2 | 259.86 | 0.0407 |
| 800 | 61 | 4.38 | 39.42 | 2540.6 | 271.62 | 61 | 4.4 | 39.6 | 2564.8 | 282.80 | 0.0361 |
| 900 | 91 | 3.81 | 41.91 | 2861.1 | 305.58 | 91 | 3.83 | 42.13 | 2888.3 | 329.40 | 0.0321 |
| 1000 | 91 | 4.01 | 44.11 | 3179.0 | 339.53 | 91 | 4.03 | 44.33 | 3209.3 | 366.00 | 0.0289 |
| 1120 | 91 | 4.25 | 46.75 | 3560.5 | 380.27 | 91 | 4.27 | 46.97 | 3594.4 | 409.92 | 0 0258 |
| 1250 | 91 | 4.49 | 49.39 | 3973.7 | 424.41 | – | – | – | – | ||
BS EN50183
| Code Name | Calculated Cross Section |
No..Dia.of Wires | Overall Diameter | Weight | Rated Strength |
| mm² | No./mm | mm | kg/km | kN | |
| Box | 18.8 | 7/1.85 | 5.55 | 51.4 | 5.55 |
| Acacia | 23.8 | 7/2.08 | 6.24 | 64.9 | 7.02 |
| Almond | 30.1 | 7/2.34 | 7.02 | 82.2 | 8.88 |
| Cedar | 35.5 | 7/2.54 | 7.62 | 96.8 | 10.46 |
| Deodar | 42.2 | 7/2.77 | 8.31 | 115.2 | 12.44 |
| Fir | 47.8 | 7/2.95 | 8.85 | 130.6 | 14.11 |
| Hazel | 59.9 | 7/3.30 | 9.90 | 163.4 | 17.66 |
| Pine | 71.6 | 7/3.61 | 10.8 | 195.6 | 21.14 |
| Holly | 84.1 | 7/3.91 | 11.7 | 229.5 | 24.79 |
| Willow | 89.7 | 7/4.04 | 12.1 | 245,0 | 26.47 |
| Oak | 118.9 | 7/4.65 | 14.0 | 324.5 | 35.07 |
| Mulberry | 150.9 | 19/3.18 | 15.9 | 414.3 | 44.52 |
| Ash | 180.7 | 19/3.48 | 17.4 | 496.1 | 53.31 |
| Elm | 211.0 | 19/3.76 | 18.8 | 579.2 | 62.24 |
| Poplar | 239.4 | 37/2.87 | 20.1 | 659.4 | 70.61 |
| Sycamore | 303.2 | 37/3.23 | 22.6 | 835.2 | 89.40 |
| Upas | 362.1 | 37/3.53 | 24.7 | 997.5 | 106.82 |
| Yew | 479.0 | 37/4.06 | 28.4 | 1319.6 | 141.31 |
| Totara | 498.1 | 37/4.14 | 29.0 | 1372.1 | 146.93 |
| Rubus | 586.9 | 61/3.50 | 31.5 | 1622.0 | 173.13 |
| Sorbus | 659.4 | 61/3.71 | 33.4 | 1822.5 | 194.53 |
| Araucaria | 821.1 | 61/4.14 | 37.3 | 2269.4 | 242.24 |
| Redwood | 996.2 | 61/4.56 | 41.0 | 2753.2 | 293.88 |
Din 48201
| Code number | Calculated area | Number of wires | Diameter of wire | Overall diameter of conductor | Linear mass | Rated tensile strength | Max. DC resistance at 20ºC |
| mm2 | mm2 | mm | mm | kg/km | daN | Ω/km | |
| 16 | 15.89 | 7 | 1.70 | 5.1 | 43 | 444 | 2.0910 |
| 25 | 24.25 | 7 | 2.10 | 6.3 | 66 | 677 | 1.3703 |
| 35 | 34.36 | 7 | 2.50 | 7.5 | 94 | 960 | 0.9669 |
| 50 | 49.48 | 7 | 3.00 | 9.0 | 135 | 1382 | 0.6714 |
| 50 | 48.35 | 19 | 1.80 | 9.0 | 133 | 1350 | 0.6905 |
| 70 | 65.81 | 19 | 2.10 | 10.5 | 181 | 1838 | 0.5073 |
| 95 | 93.27 | 19 | 2.50 | 12.5 | 256 | 2605 | 0.3579 |
| 120 | 116.99 | 19 | 2.80 | 14.0 | 322 | 3268 | 0.2854 |
| 150 | 147.11 | 37 | 2.25 | 15.8 | 406 | 4109 | 0.2274 |
| 185 | 181.62 | 37 | 2.50 | 17.5 | 500 | 5073 | 0.1842 |
| 240 | 242.54 | 61 | 2.25 | 20.3 | 670 | 6774 | 0.1383 |
| 300 | 299.43 | 61 | 2.50 | 22.5 | 827 | 8363 | 0.1120 |
| 400 | 400.14 | 61 | 2.89 | 26.0 | 1104 | 11176 | 0.0838 |
| 500 | 499.63 | 61 | 3.23 | 29.1 | 1379 | 13960 | 0.06709 |
| 625 | 626.20 | 91 | 2.96 | 32.6 | 1732 | 17490 | 0.0540 |
| 800 | 802.09 | 91 | 3.35 | 36.9 | 2218 | 22402 | 0.0418 |
| 1000 | 999.71 | 91 | 3.74 | 41.1 | 2767 | 27922 | 0.0335 |
We are China ACSR Dog 100mm2 Bare Conductor for 11kv Distribution Network manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular ACSR Products
All Aluminum Alloy Conductor AAAC Oak 100mm2
ACSR with ASTM Standard for Overhead
Overhead ACSR Conductor for Power Line
All Aluminum Alloy Conductor 100AWG ASTM B399
High Voltage Overhead Stranded Bare Aluminium Conductor
Aluminum Conductor Steel Reinforced Ibis ACSR Astmb232 Al: 26/3.14mm, Steel: 7/2.44mm
Popular Aluminum Conductor Products
95mm2 All Aluminum Alloy Conductor AAAC Overhead Bare Conductor
3 Cores Aluminum Conductor Armoured XLPE Insulated PVC Sheathed Electric Power Cable
High Quality and Favourable Price Aluminum Overhead Power Bare AAAC Conductor for Hot Sale!
Overhead Conductor (ACSR, AAC, AAAC, ACSS, ACCC, AACSR, ACAR, OPGW) Bare Conductor
AAAC - ASTM - B All Aluminium Alloy Conductor Akron Alton Ames
Popular Conductor Products
ACSR Conductor House with BS ASTM B232 Standard Cable Electrical Power Cable
Overhead Transmission Line ACSR Conductor Aluminium Cables with Type Test Report
185sqmm DIN Standard Greased Twisted Conductor AAC Conductor
120mm2 DIN48201 Standard AAC Conductor
Bare Aluminum Conductor Steel Reinforced ACSR Conductor
Popular wuhancable Products
0.34mm2 2 Core FEP Flexible Wire Silicone Rubber Jacket Power Cable High Temp 22AWG Electrical Cable
Overhead Aluminium Cable Wire ACSR Bare Conductor
BV BVV BVVB RV Copper Conductor PVC Insulated Electrical/Electric Power Cable Wire
German Sizes DIN48201 All Aluminum Alloy Condcutor AAAC 400mm2
IEC61089 All Aluminum Alloy Condcutor AAAC 630
ACSR Tern Greased Conductor for 400kv Transmission Line
Tags: ACSR, Aluminum Conductor, Conductor, wuhancable