Aerial Cable with Rated Voltage 10kv

China 
                        Aerial Cable with Rated Voltage 10kv
                      manufacture and supplier

Aerial Cable with Rated Voltage 10kv image

Get Latest Price Request a quote

Quick Details

Aerial Cable with Rated Voltage 10kv

JKYJ JKTRYJ JKLYJ etc.

Fixed Installation

Round Wire

XLPE

Copper

Overhead

Stranded

Insulated

GDYG

Wooden Reel, Steel Reel

0.5-630 mm2

Guangdong, China

Product Details


Construction Sketch 

 

1.Conductor
2.Conductor screen (no light type)
3.Weather-resistant XLPE(PE) insulation

Standards
It is manufactured in accordance with GB/T14049-2008, "Aerial cable with rated voltage 10kv" 

Size

Type  Number of cores Rated Voltage 
KV
10 35
Nominal Cross-section mm2
JKYJ 1 10-300 50-300
YKTRYJ
JKLYJ 3 25-300
JKLGYJ
JKY 1 10-300
JKTRY
JKLY
JKLYJ/Q
JKLGYJ/Q
JKLY/Q

Type and Application

Type  Name Application 
JKYJ Copper conductor XLPE insulated aerial cable  Used for fixed installation. For soft copper cable, it is used for the leading wires of transformer.
JKTRYJ Soft copper conductor XLPE insulated aerial cable 
JKLYJ Aluminum conductor XLPE insulated aerial cable   
JKLGYJ Steel core aluminum conductor XLPE insulated aerial cable  Cable should keep some distance from trees when it is being laid, and it can touch the trees frequently when it is on operation. 
JKY Copper conductor PE insulated aerial cable 
JKTRY Soft copper conductor PE insulated aerial cable 
JKLY Aluminum conductor PE insulated aerial cable  
JKLYJ/Q Aluminum conductor thin XLPE insulated light aerial cable Used for fixed installation. 
JKLGYJ/Q Steel core aluminum conductor XLPE insulated light aerial cable   
JKLY/Q Aluminum conductor thin PE insulated light aerial cable  Cable should keep some distance from trees when it is being laid, but it can touch the trees frequently when it is on operation. 

 

Features
1.The rated voltage (U/Um) is 10kv. These cables can be used in the system where the single phase earting fault duration is not more than 1 min, the maximum fault duration is not more than 8h each time and total fault duration are not more than 125h one year.
2.The installation temperature of cable shall be not lower -20ºC
3.The maximum short circuit (maximum duration is not more than 5s) temperature:
-XLPE insulated cable: 250ºC
-HDPE insulated cable: 150ºC
4.The minimum installated bended radius shall be not less than:
-Single core cable–20(D+d)
-Multicore cable–15(D+d)
(D–diameter of cable, mm; d–Nominal diameter of conductor)

Main Technical Parameter

Our company

Workshop

Certificates

We are China Aerial Cable with Rated Voltage 10kv manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular Aerial Cable Products

Overhead Aerial Bundle Cable ACSR Conductor for Power Transmission Line

0.6/1kv Low Voltage ABC Triplex Aerial Cable

Aluminum Cable Used for Aerial 3*25+25

ABC Overhead Aerial Bundled Cable with IEC60502 Standard

Bare Conductor/ AAAC Greeley Overhead Cable

10kv and 35kv Aerial Insulated Power Cable

Popular Electric Power Cable Products

Yjv/Yjlv, Yjv22, Yjlv22, 4 Aluminum/Copper Core XLPE Insulated Electrical Power Cable, Multiplex Core

China Manufacturer Low Price 100m/Roll House Copper Wire

Good Quality 70mm2 Copper Conductor XLPE Insulated Electrical Cable Price

IEC/En 60228 N2xs2y XLPE PE - 6/10 (12) Kv XLPE Insulation Stranded Copper Conductor Cable

IEC 60502 600/1000V 3 Phase 4 Core Low Voltage XLPE Cable PVC Insulated Armoured Flexible Electric Power Cable Suppliers

IEC 60228 DIN VDE 0293 PUR-Hf Trommel LV Reeling LSZH Cable

Popular Power Cables Products

N2xrh LSZH Armoured Power Hffr Cables

PE Insulated 2.5mm Electric Cable Home Use Copper Cable Electrical Power Wire

Power Cables for Aerial Power Transmission with XLPE Insulation

Electrical Control Cable PVC/XLPE Insulated Ce Approved

IEC 60502 600/1000V PVC / XLPE Insulated Power Cable

26/35kv XLPE Insulated Armored PVC Sheathed Electric Cable

Popular vangocable Products

Medium Voltage XLPE Power Cable PVC/ XLPE Insulated Electrical/ Electric Power Cable

ACSR Aluminum Conductor Steel Reinforced AAC/AAAC Standard BS IEC Standards Cable, Electrical Power Cable

AAC Aluminum Conductor Electrical Power Cable

XLPE Cable, Copper/Aluminium Core Cable. Cross Linked Polyethylene Insulated Power Cable with Sheath or Armored.

3.6/6kv~26/35kv Single Core or Multi-Core XLPE Insulated PVC PE Sheathed Power Cable.

Building Wire, PVC Cable, Power Cable, Flexible Cable, Instrument Cable, Electrical Cable, Electric Cable, Twin Earth Cable

Tags: , , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION