Aerial Power Electrical Cable 10kv Overhead Cable
Aerial Power Electrical Cable 10kv Overhead Cable image
Get Latest Price Request a quote
Quick Details
Product Details
Construction Sketch
Standards
It is manufactured in accordance with GB/T14049-2008, "Aerial cable with rated voltage 10kv"
Size
| Type | Number of cores | Rated Voltage KV |
|
| 10 | 35 | ||
| Nominal Cross-section mm2 | |||
| JKYJ | 1 | 10-300 | 50-300 |
| YKTRYJ | |||
| JKLYJ | 3 | 25-300 | – |
| JKLGYJ | |||
| JKY | 1 | 10-300 | – |
| JKTRY | |||
| JKLY | |||
| JKLYJ/Q | |||
| JKLGYJ/Q | |||
| JKLY/Q | |||
Type and Application
| Type | Name | Application |
| JKYJ | Copper conductor XLPE insulated aerial cable | Used for fixed installation. For soft copper cable, it is used for the leading wires of transformer. |
| JKTRYJ | Soft copper conductor XLPE insulated aerial cable | |
| JKLYJ | Aluminum conductor XLPE insulated aerial cable | |
| JKLGYJ | Steel core aluminum conductor XLPE insulated aerial cable | Cable should keep some distance from trees when it is being laid, and it can touch the trees frequently when it is on operation. |
| JKY | Copper conductor PE insulated aerial cable | |
| JKTRY | Soft copper conductor PE insulated aerial cable | |
| JKLY | Aluminum conductor PE insulated aerial cable | |
| JKLYJ/Q | Aluminum conductor thin XLPE insulated light aerial cable | Used for fixed installation. |
| JKLGYJ/Q | Steel core aluminum conductor XLPE insulated light aerial cable | |
| JKLY/Q | Aluminum conductor thin PE insulated light aerial cable | Cable should keep some distance from trees when it is being laid, but it can touch the trees frequently when it is on operation. |
Features
1.The rated voltage (U/Um) is 10kv. These cables can be used in the system where the single phase earting fault duration is not more than 1 min, the maximum fault duration is not more than 8h each time and total fault duration are not more than 125h one year.
2.The installation temperature of cable shall be not lower -20ºC
3.The maximum short circuit (maximum duration is not more than 5s) temperature:
-XLPE insulated cable: 250ºC
-HDPE insulated cable: 150ºC
4.The minimum installated bended radius shall be not less than:
-Single core cable–20(D+d)
-Multicore cable–15(D+d)
(D–diameter of cable, mm; d–Nominal diameter of conductor)
Main Technical Parameter
Our company
Workshop
Certificates
We are China Aerial Power Electrical Cable 10kv Overhead Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Overhead Cable Products
Aluminum Conductor PE Insulated Triplex Cable
ABC Cables, Overhead Insulated Cable, Aerial Bundled Cable
2/0AWG Quadplex Aerial Bundled Cable ABC Cable
0.6 / 1kv XLPE Insulated Overhead Electric Transmission Aerial Bundle Cable
All Aluminium Alloy Conductor 54.6 Sqmm
ASTM B399 Overhead /AAAC Conductor
Popular Power Cables Products
240mm XLPE 4 Copper/Aluminium Core Armoured Cable Electric Power Cable
Power Transmission Used ACSR Cable Bare Aluminum Conductor Rabbit Horse Zebra
Copper/Aluminium Conductor XLPE Insulated Power Cable Electric Cable
Underground Armoured Power Cable Swa XLPE PVC Size 4 Cores Armoured Electric Power Cable
0.6/1kv LV Copper Core XLPE Insulated Steel-Tape Armoured and PVC Sheathed Electrical Power Cable
Popular Power Electrical Cable Products
Medium Voltage Copper/Aluminium Aerial Cable XLPE PE Insulated Aerial Cable
10kv 35kv Aerial Insulated Cable, Aluminium/Copper Conductor Aerial Cable.
Aluminum Conductor XLPE Insulated Aerial Cable
Electrical Cable Wire Aerial Cable Aluminum/Copper Conductor& XLPE Insulated
Popular vangocable Products
AAC All Aluminum Conductor Overhead Bare Conductor
Factory Price Electric Wiring Cable Flexible Cable Building Wire
Low Voltage BV BVV RV Rvv Copper Conductor PVC Insulation Sheath Electrical Electric Wire
ACSR Conductor Overhead Conductor ACSR Factory
Tw Thw Electrical Copper Wire Building Wire PVC Sheath
Tags: Overhead Cable, Power Cables, Power Electrical Cable, vangocable