ASTM ACSR Conductor Used as Bare Overhead Transmission

China 
                        ASTM ACSR Conductor Used as Bare Overhead Transmission
                      manufacture and supplier

ASTM ACSR Conductor Used as Bare Overhead Transmission image

Get Latest Price Request a quote

Quick Details

ASTM ACSR Conductor Used as Bare Overhead Transmission

ACSR-Dayuan-062

Dayuan

ISO9001, CE, CCC

Overhead Transmision

Round Wire

XLPE

Non

Aluminum

Overhead

Stranded

Insulated

All Products Checked by Experienced QC

Welcome

Welcome

15days~35days After Order Confirmed

High Voltage

Circular Core or Compact Core

1.5-800 mm2

ASTM, IEC502, BS7870-5, GB12527-91

Under 330kv

Luoyang Dayuan

Use The Drum, We Can Make as Customer Requirement

IEC, ASTM, ICEA, BS, DIN

Luoyang, China

85444929

Product Details

ASTM ACSR Conductor Used as Bare Overhead Transmission

We have one big workshop to produce the raw material: aluminium wire rod, many company buy it from us to produce various cable so that our monthly turnover of it has up to 100 million!

So our price is very competitive and can gurantee the delivery time!

 xlpe insulation abc cable

 

Primarily used for 120 volt overhead service applications such as street lighting, outdoor lighting, and temporary service for construction. To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for cross-linked polyethylene (XLPE) insulated conductors.

 

 xlpe insulation abc cable 
 

service drop cable meets or exceeds the following ASTM specifications:

· B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.

· B-231 Aluminum Conductors, Concentric-Lay-Stranded.

· B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).

· B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.

· B-901 Compressed Round Stranded Aluminum Conductors Using Single Input Wire

 

xlpe insulation abc cable

Conductors are concentrically stranded, compressed 1350 H-19 aluminum. Insulated with either polyethylene or cross-linked polyethylene (XLPE). Neutral messengers are concentrically stranded 6201, AAC, or ACSR.

 

2x16mm2 abc cable information 1

 xlpe insulation abc cable specification

code Rated Voltage   Type ABC
AWG or kcmil Structure
Neutral Wire (ACSR) Phase Wire   Cable Cable
Steel Aluminium Conductor Aluminium Dia   Dia Dia kg/km
No. Dia No. Dia Dia No. Dia mm
Morochuca 3*6AWG+1*6AWG 1 1.68  6 1.68  5.04 1 4.11  4.11 1.14 6.40  14.62 221
Chola 3*6AWG+1*6AWG 1 1.68  6 1.68  5.04 7 1.55  4.66 1.14 6.95 15.62 227
Morgan 3*4AWG+1*4AWG 1 2.12  6 2.12  6.36 1 5.19  5.19 1.14 7.48 17.37 331
Hackney 3*4AWG+1*4AWG 1 2.12  6 2.12  6.36 7 1.96  5.88 1.14 8.17 18.62 338
Palomino 3*2AWG+1*2AWG 1 2.67  6 2.67  8.02 7 2.47  7.42 1.14 9.71 22.41 511
Costena 3*1/0AWG+1*1/0AWG 1 3.37  6 3.37  10.11 19 1.89  9.47 1.52 12.52 28.77 824
Grullo 3*2/0AWG+1*2/0AWG 1 3.78  6 3.78  11.35 19 2.13  10.63 1.52 13.68 31.61 1015
Suffolk 3*3/0AWG+1*3/0AWG 1 4.25  6 4.25  12.74 19 2.39  11.94 1.52 14.99 34.82 1254
Appaloosa 3*4/0AWG+1*4/0AWG 1 4.77  6 4.77  14.31 19 2.68  13.40  1.52 16.45 38.42 1554
Broneo 3*336.4+1*336.4 1 3.47  18 3.47  17.36 19 3.38  16.90  2.03 20.96 48.43 2321
Gelding 3*336.4+1*4/0AWG 1 4.77  6 4.77  14.31 19 3.38  16.90  2.03 20.96 46.59 2221

 

 

 

xlpe insulation abc cable workshop corner

 

xlpe insulation abc cable customer visit our factory

 

xlpe insulation abc cable packing 

 

xlpe insulation abc cable why you choose us

Our Principles

1. Quality first, customer first, safety first
2. Better service, faster delivery
3. Equal and mutual benefit
4. Honest and professional

Why choose us?
1. Swift and professional response
2. Patient and trusty
3. Severe quality control system
4. On-time delivery

xlpe insulation abc cable pls contact with us

Contact
Emily Wang

Department sale manager
International Trade Department
Luoyang Asian Sun Industrial Group Co., Ltd
=================================

Tel: +86-379-65170063                    
Mobile: + 86-18338892373
Web: http://dycable.en.
Alibaba Showroom: http://dycable.en.
=================================

We are China ASTM ACSR Conductor Used as Bare Overhead Transmission manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular Aerial Bundle Cable Products

0.6/1kv Standard Triplex Service Drop Overhead Cable

0.6/1kv Quadruplex ABC Aerial Bundle Cable for Overhead Transmission Line

ABC, Distribution System Overhead Cable (1000V)

1000V, Distribution System Overhead Cable (1000V) , 3X50+54.6+1X25mm2

Al/XLPE 0.6/1kv ABC Cable Quadruplex ABC Cable

Aluminum Conductors Steel Reinforced Aluminum Covered Line Wire ABC

Popular Aerial Bunduled Cable Products

LV IEC Standard 4X50mm2 Aerial Bundled Cable Aluminum ABC Cable

10kv ABC Cable/Aerial Bundled Cable/Aerial Bounded Cable

0.6/1kv 33kv PVC XLPE Service Drop Conductor Aerial Bundled Cable

PVC / XLPE / PE Insulated Service Drop Overhead Aerial Bundled Cable

Parallel Aerial Bunched Cable (1KV 4X50)

NFC 33-209 Low Voltage XLPE Insulated ABC Conductor Aerial Bundle Cable

Popular Aluminum Conductor Products

Flexible Cable and Aluminum Cable

50mm2 AAC ANT Bare Conductor BS 215-1 Aluminum stranded conductor for 11kV Distribution Line

Aerial Cable Aluminum Core Bare Conductor Power Line

XLPE Construction 5kv Urd Cable Medium Voltage Power Mv90, Mv105

Aluminum Wire

Round Wire China UL1072 Certificate XLPE Cable Medium Voltage Power Mv90, Mv105

Popular dycable Products

Professional Manufacturer Aluminum Conductor ACSR Rabbit Bare Conductor

BV Building Electrical Wires for Housing

Solid Copper Core PVC Insulated Wire 2.5mm

High Strength Aluminum Conductor ACSR for Overhead Power Transmission Lines

High Performance Aluminium Wire Rod 9.5mm Professional Manufacturer

ABC Conductors with XLPE Insulation Cable 3cx 95sqmm+1cx50sqmm

Tags: , , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION