AAC All Aluminum Conductor Overhead Power Transmission Aerial Bundled Cable
AAC All Aluminum Conductor Overhead Power Transmission Aerial Bundled Cable image
Get Latest Price Request a quote
Quick Details
Product Details
Product Description
AAC All Aluminum Conductor Aerial Bundle Cable
1. Specification
| JL All Aluminum Conductor Basic parameter | ||
| Specification | Outer Diameter of Cable | Approximate weight |
| 10 | 4.05 | 27.95 |
| 16 | 5.13 | 45.00 |
| 25 | 6.39 | 69.59 |
| 35 | 7.50 | 96.14 |
| 40 | 8.10 | 112.08 |
| 50 | 9.00 | 138.35 |
| 63 | 10.20 | 176.64 |
| 70 | 10.80 | 199.28 |
| 95 | 12.50 | 265.80 |
| 100 | 13.0 | 279.49 |
| 120 | 14.3 | 338.18 |
| 125 | 14.5 | 349.36 |
| 150 | 15.8 | 413.65 |
| 160 | 16.4 | 447.18 |
| 185 | 17.5 | 511.47 |
| 200 | 18.3 | 558.98 |
| 210 | 18.8 | 586.93 |
| 240 | 20.0 | 667.98 |
| 250 | 20.5 | 698.73 |
| 300 | 22.4 | 832.88 |
| 315 | 23.0 | 880.39 |
| 400 | 26.0 | 1117.96 |
| 450 | 27.6 | 1260.50 |
| 500 | 29.1 | 1405.84 |
| 560 | 30.7 | 1565.15 |
| 630 | 32.7 | 1763.58 |
| 710 | 34.7 | 1984.38 |
| 800 | 36.8 | 2238.72 |
| JL/G1A JL/G2A JL/G3A JL1/G1A JL1/G2A JL1/G3A JL2/G1A JL2/G2A JL2/G3A &JL3/G1A JL3/G2A JL3/G3A Aluminum Conductor Steel Reinforced Basic parameter |
|||||
| Specification | Outer Diameter of Cable | Approximate weight | Specification | Outer Diameter of Cable | Approximate weight |
| 10/2 | 4.50 | 43.68 | 240/30 | 21.6 | 932.18 |
| 16/3 | 5.55 | 66.23 | 240/40 | 21.7 | 975.04 |
| 25/4 | 6.90 | 102.35 | 240/55 | 22.4 | 1117.98 |
| 35/6 | 8.16 | 143.40 | 250/25 | 21.5 | 892.12 |
| 40/6 | 8.73 | 164.01 | 250/40 | 22.2 | 1020.00 |
| 50/8 | 9.60 | 198.46 | 300/15 | 23.0 | 950.86 |
| 50/30 | 11.6 | 375.35 | 300/20 | 23.1 | 995.25 |
| 65/10 | 11.0 | 259.24 | 300/25 | 23.8 | 1069.16 |
| 70/10 | 11.4 | 279.25 | 300/40 | 23.9 | 1145.53 |
| 70/40 | 13.6 | 516.07 | 300/50 | 24.3 | 1223.68 |
| 95/15 | 13.6 | 384.61 | 300/70 | 25.2 | 1415.26 |
| 95/20 | 13.9 | 414.19 | 315/22 | 23.9 | 1055.27 |
| 95/55 | 16.0 | 714.12 | 400/20 | 26.9 | 1299.71 |
| 100/17 | 13.8 | 411.31 | 400/25 | 26.6 | 1309.52 |
| 120/7 | 14.5 | 384.69 | 400/35 | 26.8 | 1364.35 |
| 120/20 | 15.1 | 472.61 | 400/50 | 27.6 | 1526.85 |
| 120/25 | 15.7 | 532.00 | 400/65 | 28.0 | 1629.04 |
| 120/70 | 18.0 | 903.79 | 400/95 | 29.1 | 1876.79 |
| 125/7 | 14.9 | 404.07 | 450/30 | 28.6 | 1503.20 |
| 125/20 | 15.6 | 588.54 | 450/60 | 29.3 | 1721.49 |
| 150/8 | 16.0 | 468.73 | 500/35 | 30.1 | 1670.57 |
| 150/20 | 16.7 | 556.46 | 500/45 | 30.0 | 1706.92 |
| 150/25 | 17.1 | 607.47 | 500/65 | 30.9 | 1905.37 |
| 150/35 | 17.5 | 682.39 | 560/40 | 31.8 | 1869.84 |
| 160/9 | 16.8 | 517.20 | 560/70 | 32.7 | 2122.01 |
| 185/10 | 18.0 | 591.98 | 630/45 | 33.8 | 2100.58 |
| 185/25 | 18.9 | 713.67 | 630/55 | 34.3 | 2233.15 |
| 185/30 | 18.9 | 739.53 | 630/80 | 34.7 | 2386.32 |
| 185/45 | 19.6 | 857.27 | 710/50 | 35.9 | 2369.95 |
| 200/11 | 18.8 | 646.60 | 710/90 | 36.8 | 2688.85 |
| 210/10 | 19.0 | 659.36 | 720/50 | 36.2 | 2421.77 |
| 210/25 | 20.0 | 798.05 | 800/55 | 38.4 | 2719.46 |
| 210/35 | 20.4 | 864.06 | 800/70 | 38.6 | 2821.09 |
| 210/50 | 20.9 | 969.34 | 800/100 | 39.1 | 3038.27 |
| All Aluminum Alloy Conductor Basic parameter | |||||
| JLHA1 JLHA2 | JLHA3 JLHA4 | ||||
| Specification | Outer Diameter of Cable | Approximate weight | Specification | Outer Diameter of Cable | Approximate weight |
| 16 | 5.13 | 45.11 | 25 | 6.39 | 69.77 |
| 20 | 5.49 | 51.56 | 35 | 7.50 | 96.39 |
| 25 | 6.39 | 69.77 | 40 | 8.10 | 112.37 |
| 30 | 6.87 | 80.70 | 50 | 9.00 | 138.71 |
| 35 | 7.56 | 97.79 | 70 | 10.8 | 199.79 |
| 45 | 8.67 | 128.62 | 95 | 12.5 | 266.48 |
| 50 | 9.06 | 140.39 | 100 | 13.0 | 280.21 |
| 70 | 10.7 | 196.43 | 120 | 14.3 | 339.06 |
| 75 | 10.9 | 202.87 | 125 | 14.5 | 350.27 |
| 95 | 12.5 | 266.48 | 150 | 15.8 | 414.72 |
| 120 | 13.9 | 322.25 | 185 | 17.5 | 512.79 |
| 145 | 15.5 | 400.71 | 200 | 18.3 | 560.43 |
| 150 | 15.9 | 420.32 | 210 | 18.8 | 588.45 |
| 185 | 17.6 | 515.59 | 240 | 20.0 | 669.71 |
| 210 | 18.8 | 588.45 | 250 | 20.5 | 700.54 |
| 230 | 19.7 | 644.49 | 275 | 21.6 | 773.39 |
| 240 | 20.1 | 672.51 | 280 | 21.7 | 781.80 |
| 300 | 22.5 | 837.84 | 300 | 22.4 | 835.04 |
| 360 | 24.7 | 1014.37 | 315 | 23.0 | 882.67 |
| 400 | 26.0 | 1120.86 | 335 | 23.8 | 941.52 |
| 465 | 27.9 | 1288.98 | 340 | 23.9 | 952.73 |
| 500 | 29.1 | 1401.07 | 400 | 26.0 | 1120.86 |
| 520 | 29.5 | 1451.51 | 425 | 26.8 | 1193.71 |
| 580 | 31.2 | 1611.23 | 450 | 27.6 | 1263.77 |
| 630 | 32.7 | 1768.15 | 500 | 29.1 | 1409.48 |
| 650 | 33.0 | 1807.38 | 530 | 30.0 | 1487.94 |
| 720 | 35.0 | 2031.55 | 560 | 30.7 | 1569.20 |
| 800 | 36.8 | 2244.51 | 630 | 32.7 | 1768.15 |
| 675 | 33.8 | 1888.64 | |||
| 710 | 34.7 | 1989.52 | |||
| 800 | 36.8 | 2244.51 | |||
| JL(JL1,JL2,JL3)/LHA1 Aluminum Conductor Alloy Reinforced Basic parameter |
||
| Specification | Outer Diameter of Cable | Approximate weight |
| 25/20 | 8.34 | 118.92 |
| 40/30 | 10.5 | 187.47 |
| 60/45 | 13.2 | 297.71 |
| 80/50 | 14.9 | 368.16 |
| 105/60 | 16.8 | 470.27 |
| 130/140 | 21.4 | 758.42 |
| 135/80 | 18.9 | 593.36 |
| 135/140 | 21.6 | 772.42 |
| 135/145 | 21.7 | 780.81 |
| 165/170 | 23.8 | 940.34 |
| 165/175 | 23.9 | 951.53 |
| 170/95 | 21.1 | 739.68 |
| 210/220 | 26.8 | 1192.21 |
| 210/230 | 27.6 | 1262.18 |
| 235/250 | 28.7 | 1368.52 |
| 260/275 | 30.2 | 1516.85 |
| 265/60 | 23.4 | 906.83 |
| 270/420 | 34.2 | 1937.11 |
| 307/470 | 36.3 | 2177.85 |
| 335/80 | 26.4 | 1155.14 |
| 345/530 | 38.5 | 2454.98 |
| 365/165 | 30.0 | 1485.29 |
| 375/85 | 27.9 | 1293.28 |
| 415/95 | 29.5 | 1441.20 |
| 455/205 | 33.5 | 1854.52 |
| 465/110 | 31.2 | 1616.24 |
| 465/210 | 33.8 | 1885.28 |
| 505/65 | 31.1 | 1594.69 |
| 515/230 | 35.6 | 2092.27 |
| 535/240 | 36.2 | 2159.39 |
| 570/390 | 40.3 | 2677.54 |
| 580/260 | 37.7 | 2352.41 |
| 630/430 | 42.5 | 2979.70 |
| 650/295 | 40.0 | 2640.52 |
| 665/300 | 40.5 | 2710.44 |
| 705/485 | 45.0 | 3343.43 |
| 745/335 | 42.8 | 3029.31 |
| 790/540 | 47.5 | 3732.32 |
| 800/550 | 47.9 | 3785.48 |
| JLHA3/G1A (G2A ,G3A)&JLHA4/G1A (G2A ,G3A) Aluminum Alloy Conductor Steel Reinforced Basic parameter |
|||||
| Specification | Outer Diameter of Cable | Approximate weight | Specification | Outer Diameter of Cable | Approximate weight |
| 10/2 | 4.50 | 43.75 | 240/40 | 21.7 | 976.77 |
| 16/3 | 5.55 | 66.35 | 240/55 | 22.4 | 1119.73 |
| 35/6 | 8.16 | 143.66 | 300/15 | 23.0 | 953.01 |
| 50/8 | 9.60 | 198.81 | 300/20 | 23.4 | 1014.02 |
| 50/30 | 11.6 | 375.72 | 300/25 | 23.8 | 1071.37 |
| 70/10 | 11.4 | 279.74 | 300/40 | 23.9 | 1147.70 |
| 70/40 | 13.6 | 516.58 | 300/50 | 24.3 | 1225.85 |
| 95/15 | 13.6 | 385.29 | 300/70 | 25.2 | 1417.47 |
| 95/20 | 13.9 | 414.88 | 400/20 | 26.9 | 1302.65 |
| 95/55 | 16.0 | 714.82 | 400/25 | 26.6 | 1312.36 |
| 120/7 | 14.5 | 385.63 | 400/35 | 26.8 | 1367.18 |
| 120/20 | 15.1 | 473.45 | 400/50 | 27.6 | 1529.74 |
| 120/25 | 15.7 | 532.89 | 400/65 | 28.0 | 1631.93 |
| 120/70 | 18.0 | 904.67 | 400/95 | 29.1 | 1879.75 |
| 150/8 | 16.0 | 469.77 | 460/60 | 29.8 | 1778.19 |
| 150/20 | 16.7 | 557.51 | 500/35 | 30.1 | 1674.19 |
| 150/25 | 17.1 | 608.54 | 500/45 | 30.0 | 1710.46 |
| 150/35 | 17.5 | 683.45 | 500/65 | 31.0 | 1920.55 |
| 185/10 | 18.0 | 593.31 | 630/45 | 33.8 | 2105.13 |
| 185/25 | 18.9 | 715.03 | 630/55 | 34.3 | 2237.78 |
| 185/30 | 18.9 | 740.84 | 630/80 | 34.5 | 2365.74 |
| 185/45 | 19.6 | 858.61 | 710/50 | 35.9 | 2375.08 |
| 210/10 | 19.0 | 660.83 | 710/90 | 36.8 | 2693.98 |
| 210/25 | 20.0 | 799.56 | 720/50 | 36.2 | 2427.02 |
| 210/35 | 20.4 | 865.59 | 800/55 | 38.2 | 2688.92 |
| 210/50 | 20.9 | 970.85 | 800/70 | 38.6 | 2826.94 |
| 240/30 | 21.6 | 933.95 | 800/100 | 39.1 | 3041.69 |
2. Our Factory
3. Our Honor
4. Contact Details
Jessica Wang | Taifeng Cable Co., Ltd.
Add.: Heda Center, No.177 Tailiu Road, Shibei District, Qingdao, China
Factory Add.: No.1 Taifeng Road, Dacaozhuang Administrative Zone, Xingtai City, Hebei Province, China
Tel: 0086 532 85611663
Phone: 0086 15192706553
Website: taifengcable.en.
We are China AAC All Aluminum Conductor Overhead Power Transmission Aerial Bundled Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Aerial Bundle Cable Products
XLPE Insulated Overhead ABC Cable
Quadruplex AL/PE Cable (Aerial Bundle Cable)
Overhead ABC Aerial Bundled Cable Size 2*16mm2
0.6/1kv Aluminiun Core Aerial Bundled Cable ABC Cable
AAAC All Aluminum Alloy Conductor Overhead Power Aerial Bundle Cable
Al/XLPE+ACSR 0.6/1kv Overhead ABC Cable
Popular taifengcable Products
LSZH Lsoh Ls0h Lsfh Ohls XLPE Insulated Sheathed Electric Power Cable
Copper Conductor Crane Control Cable with High Performance Assembly and Production Lines
Mv 240mm2 Steel Wire Armoured/Armored Cooper Electric Wire Cable
0.6/1kv Power Aluminum Conductor Innovative Concept XLPE Insulated Overhead Aerial Bundle ABC Cable
Aerial Bundled Cable ABC Cable Overhead Cable ASTM BS NFC IEC DIN Standard
Popular Triplex Cable Products
Overhead Insulated Cable XLPE Insulated Aluminum Duplex ABC Cable
Service Entrance Cable Triplex Arca 4/0 AWG AAC/XLPE/PE+2/0 AWG AAAC Naked
Aerial Service Cable 4X16 mm2, Alu - NFC 33 209
Low Voltage Aerial Bundled Cable Triplex ABC Cable for Overhead Transmission
Top Quality Aluminum Alloy Aerial Bundled Cable 2, 3, 4 Core
Popular Twisted Aluminum Cable Products
Overhead Insulated Wire Cable Aluminum Core Service Drop
XLPE Insulation 4*25 Overhead ABC Service Drop Cables
LV ABC Cable 600V Phase Conductor 90º C XLPE Insulated Cable
AAAC All Aluminum Alloy Conductor Overhead Power Aerial Bundle Cable
Overhead Aluminium Bare AAC Conductor for Transmission Line Use
Tags: Aerial Bundle Cable, taifengcable, Triplex Cable, Twisted Aluminum Cable